Assessment of Air Cooling for Use with Automotive Power Electronics
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided
The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.
High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.
A dual energy electron storage ring configuration is initially proposed as an electron cooler to cool the ion beam in a collider. It consists of two energy loops, the electron beam in the high energy loop undergoes the synchrotron radiation damping to obtain the desired beam property and the beam in the low energy loop is for cooling of the ion beam. The two different energy loops are connected by an energy recovery linac. A lattice design of such a dual energy storage ring has been completed and beam stability conditions are established. We performed numerical simulations to demonstrate the beam qualities and evaluated the cooling performance. In this paper, we present the study results and discuss possible applications of such a concept in many physics research and medical fields.
Hot tail runaway electron generation is caused by incomplete thermalization of the electron velocity distribution during rapid plasma cooling. It is an important runaway electron mechanism in tokamak disruptions if the thermal quench phase is sufficiently fast. Analytical estimates of the density of produced runaway electrons are derived for cases of exponential-like temperature decay with a cooling rate lower than the collision frequency. Numerical simulations, aided by the analytical results, are used to compare the strength of the hot tail runaway generation with the Dreicer mechanism for different disruption parameters (cooling rate, post-thermal quench temperature, and electron density) assuming that no losses of runaway electrons occur. It is seen that the hot tail runaway production is going to be the dominant of these two primary runaway mechanisms in ITER [R. Aymar et al., Plasma Phys. Controlled Fusion 44, 519 (2002)].
The presentation was developed for the U.S. Department of Energy (DOE) Vehicle Technologies Program 2020 Annual Merit Review and Peer Evaluation Meeting. It reports on progress and accomplishments of DOE funded Integrated Traction Drive Thermal Management project. Highlighted are NREL's research accomplishments during FY 2020. Challenges associated with thermal management of integrated traction drives for electric vehicles arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. For this project at NREL, research focuses on enabling thermal management technologies to support a modular, compact, self-contained integrated electric drive unit with motor and power electronics. Integration approaches, based on packaging location and coolant options for power electronics integrated with candidate motor technologies to reduce cables and connectors, are reviewed and compared using finite element analysis (FEA) tools. Automatic transmission fluid (ATF) jet impingement cooling characterization is carried out experimentally (measuring heat transfer coefficients) and using computational fluid dynamics (CFD) modeling.
Highlights: • Water cooling improves tensile properties of friction stir welded 7055 Al alloy. • Water cooling results in smaller grains and second phase in nugget zone. • Water cooling results in finer second phase in thermos-mechanically affected zone. • Water cooling results in finer second phase in heat affected zone. • Fracture surface is flat for air-cooled joint but zig-zag for water-cooled one. - Abstract: The microstructure and mechanical properties of friction stir welded 7055 aluminium alloy under air cooling and water cooling were investigated by means of hardness and tensile testing, optical microscopy and transmission electron microscopy. Water cooling results in reduced softening in the weld zone and therefore higher tensile strength compared to air cooling. Fracture generally occurs within the thermo-mechanically affected zone (TMAZ) and heat affected zone (HAZ) on the retreating side in joints welded under air cooling but shifts towards the TMAZ and nugget zone (NZ) in the joints welded under water cooling. The fracture surfaces are generally flat for the air-cooled joint, but exhibits a zig-zag feature for the water-cooled joint. The mechanical behaviour of the weld has been discussed in light of the change in grain structure and precipitation in the NZ, TMAZ and HAZ caused by cooling conditions.
Minority relativistic electron populations can occur in a range of complex plasmas. Of specific interest is when runaway electrons form among the presence of high-atomic-number ion species in a tokamak plasma discharge. It has been recently demonstrated that ion charge state distributions and radiation losses at low bulk electron temperatures can be dominated by relativistic electrons, even though their density is orders of magnitude lower. Furthermore, this was attributed to the relativistic enhancement of electron impact inelastic cross sections. In this work, we provide a closer inspection of the atomic physics underpinning this effect. We also demonstrate the consequences of runaway enhanced scattering on post-disruption tokamak fusion discharges with neon and argon impurities present. Effects on charge state distributions, radiation and spectral characteristics, and reduced-order modeling considerations are discussed.
Internal emission of photoelectrons from metal films and nanoparticles (nanowires and nanospheres) into a semiconductor matrix is studied theoretically by taking into account the jump of the effective electron mass at the metal – semiconductor interface and the cooling effect of hot electrons due to electron – electron collisions in the metal. The internal quantum efficiency of photoemission for the film and nanoparticles of two types (nanospheres and nanowires) is calculated. It is shown that the reduction of the effective mass of the electron during its transition from metal to semiconductor may lead to a significant (orders of magnitude and higher) decrease in the internal quantum efficiency of bulk photoemission. (nanostructures)
The Recycler Electron Cooler (REC) was the first cooler working at a relativistic energy (gamma = 9.5). It was successfully developed in 1995-2004 and was in operation at Fermilab in 2005-2011, providing cooling of antiprotons in the Recycler ring. After introducing the physics of electron cooling and the REC system, this paper describes measurements carried out to tune the electron beam and optimize its cooling properties. In particular, we discuss the cooling strategy adopted for maximizing the collider integrated luminosity.
In this Thesis, the cooling of the electronics of the Mu2e calorimeter has been discussed. The analysed technical solutions for the cooling of the front-end boards, the waveform digitizers boards and the interface boards have been presented. The project of the crate has been showed in detail. It is placed in the outer surface of the calorimeter disk and it is a mechanical support for the boards and also part of the thermal circuit. The distributing system of the refrigerant fluid for the whole calorimeter has been analysed too. Then the manufacturing solutions of the crates and the components for the thermal path have been developed. At the end, the main experimental tests have been presented. They are going to be realized in the next months.
Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.
The goal of the project was to investigate the possibility of building a very high intensity polarized electron gun for the Electron-Ion Collider. This development is crucial for the eRHIC project. The gun implements a large area cathode, ring-shaped laser beam and active cathode cooling. A polarized electron gun chamber with a large area cathode and active cathode cooling has been built and tested. A preparation chamber for cathode activation has been built and initial tests have been performed. Major parts for a load-lock chamber, where cathodes are loaded into the vacuum system, have been manufactured.
High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.