Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Assessment of Gamma-Ray-Spectra Analysis Method Utilizing the Fireworks Algorithm for Various Error Measures

The analysis of measured data plays a significant role in enhancing nuclear nonproliferation mainly by inferring the presence of patterns associated with special nuclear materials. Among various types of measurements, gamma-ray spectra is the widest utilized type of data in nonproliferation applications. In this paper, a method that employs the fireworks algorithm (FWA) for analyzing gamma-ray spectra aiming at detecting gamma signatures is presented. In particular, FWA is utilized to fit a set of known signatures to a measured spectrum by optimizing an objective function, where non-zero coefficients express the detected signatures. FWA is tested on a set of experimentally obtained measurements optimizing various objective functions—MSE, RMSE, Theil-2, MAE, MAPE, MAP—with results exhibiting its potential in providing highly accurate and precise signature detection. Finally and furthermore, FWA is benchmarked against genetic algorithms and multiple linear regression, showing its superiority over those algorithms regarding precision with respect to MAE, MAPE, and MAP measures.

97 MATHEMATICS AND COMPUTING↗

Elucidation of Peptide-Directed Palladium Surface Structure for Biologically Tunable Nanocatalysts

Peptide-enabled synthesis of inorganic nanostructures represents an avenue to access catalytic materials with tunable and optimized properties. This is achieved via peptide complexity and programmability that is missing in traditional ligands for catalytic nanomaterials. Unfortunately, there is limited information available to correlate peptide sequence to particle structure and catalytic activity to date. As such, the application of peptide-enabled nanocatalysts remains limited to trial and error approaches. In this paper, a hybrid experimental and computational approach is introduced to systematically elucidate biomolecule-dependent structure/function relationships for peptide-capped Pd nanocatalysts. Synchrotron X-ray techniques were used to uncover substantial particle surface structural disorder, which was dependent upon the amino acid sequence of the peptide capping ligand. Nanocatalyst configurations were then determined directly from experimental data using reverse Monte Carlo methods and further refined using molecular dynamics simulation, obtaining thermodynamically stable peptide-Pd nanoparticle configurations. Sequence-dependent catalytic property differences for C-C coupling and olefin hydrogenation were then eluddated by identification of the catalytic active sites at the atomic level and quantitative prediction of relative reaction rates. This hybrid methodology provides a clear route to determine peptide-dependent structure/function relationships, enabling the generation of guidelines for catalyst design through rational tailoring of peptide sequences

atomic pair distribution function↗

Automatic parameter selection for electron ptychography via Bayesian optimization

Abstract Electron ptychography provides new opportunities to resolve atomic structures with deep sub-angstrom spatial resolution and to study electron-beam sensitive materials with high dose efficiency. In practice, obtaining accurate ptychography images requires simultaneously optimizing multiple parameters that are often selected based on trial-and-error, resulting in low-throughput experiments and preventing wider adoption. Here, we develop an automatic parameter selection framework to circumvent this problem using Bayesian optimization with Gaussian processes. With minimal prior knowledge, the workflow efficiently produces ptychographic reconstructions that are superior to those processed by experienced experts. The method also facilitates better experimental designs by exploring optimized experimental parameters from simulated data.

42 ENGINEERING↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Patterson function as auto-hologram and graph enables the direct solution to the phase problem for coherently illuminated atomistic structures

Abstract The coherent Patterson function, derived from the coherent scattering intensities from N atoms, can be described as an auto-holographic image, i.e., the superposition of N -holographic images in which each atom serves as the source of a different reference wave, and as a mathematical graph of the unknown structure. These insights indicate that the unknown structure is significantly over-determined by the inherent information content in a Patterson function by a factor of ( N − 1)/2 (for non-degenerate structures), independent of dimensionality. However, we also show that the ability to resolve the distinct features in the Patterson function depends strongly on details of the experimental design (data range, sampling frequency, and dimensionality). This re-interpretation suggests that the coherent Patterson function provides a natural context for describing the information content in coherent scattering, reveals that there is no inherent phase problem for coherently illuminated pointwise structures, and enables the design of an algorithm which retrieves the structure directly from the Patterson function, without using error metric minimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unsupervised Deep Learning Can Identify Physical Parameters

Parametrizing a problem is one of the biggest obstacles toward the application of physical methods to novel systems. In this research, we show that deep learning methods can be used to accelerate this parametrization process. We use an unsupervised learning algorithm, a variational autoencoder, to extract meaningful physical parameters from unlabeled time-series generated from classical physical systems. For example, given time series data of projectile motion and the instruction to represent the data in a small number of unspecified parameters, the model can discover, without further direction, the concepts of velocity and gravity. Using this method, one can uncover information about the physics of a system, even when the relevant physical parameters are unknown to the experimenter. This has obvious applications to novel systems in which parameters are not known a priori. Moreover, errors in the reconstruction of the parameters can be used to reveal meaningful info rmation about state transitions, which can be conceptualized as a generalization of similar unsupervised learning methods used to detect phase transitions in the thermodynamics of particle systems to systems that evolve in the time domain. While our proof-of-concept applications are modest, this method shows potential for making progress in a wide array of problems both in physics and outside of the field.

Veillette, John↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Experimental assessment of unvalidated assumptions in classical plasticity theory.

This report investigates the validity of several key assumptions in classical plasticity theory regarding material response to changes in the loading direction. Three metals, two rock types, and one ceramic were subjected to non-standard loading directions, and the resulting strain response increments were displayed in Gudehus diagrams to illustrate the approximation error of classical plasticity theories. A rigorous mathematical framework for fitting classical theories to the data, thus quantifying the error, is provided. Further data analysis techniques are presented that allow testing for the effect of changes in loading direction without having to use a new sample and for inferring the yield normal and flow directions without having to measure the yield surface. Though the data are inconclusive, there is indication that classical, incrementally linear, plasticity theory may be inadequate over a certain range of loading directions. This range of loading directions also coincides with loading directions that are known to produce a physically inadmissible instability for any nonassociative plasticity model.

36 MATERIALS SCIENCE↗

Data-driven multi-element substitution of TiFe alloys for tunable thermodynamics and enhanced activation behaviour for hydrogen storage

Due to their high volumetric hydrogen storage capacity under moderate storage conditions, TiFe alloys have been widely investigated as candidates for practical solid-state hydrogen storage. Partially substituting Ti or Fe sites can improve the key characteristics of TiFe alloys, such as the first hydrogen absorption step (activation) and the equilibrium hydrogen pressure (thermodynamic properties). However, the selection of substitution elements has heavily relied on intuition and trial-and-error. Also, conventional substitution strategies have mainly focused on single-element substitution within the TiFe alloy, limiting the design space and tunability for target applications. Here, to address this limitation, we report a multi-element substitution strategy motivated by an efficient, data-driven machine learning (ML) approach combined with corroborating density functional theory (DFT) calculations. Our models successfully predict experimentally measured hydride stability in five selected alloys using only compositional descriptors. Most importantly, the multi-element substitution leads to enhanced activation properties compared to pure TiFe, achieving near room-temperature activation behaviour. This work provides a method for on-demand tuning of hydrogen storage and activation properties, which may have broad implications for data-driven discovery of energy storage materials.

Cho, YongJun [Korea Advanced Institute Science and↗

Neutral and charged excitations in carbon fullerenes from first-principles many-body theories

We use first-principles many-body theories to investigate the low energy excitations of the carbon fullerenes C_20, C_24, C_50, C_60, C_70, and C_80. Properties are calculated via the GW-Bethe-Salpeter Equation (GW-BSE) and diffusion Quantum Monte Carlo (QMC) methods. At a lower level of theoretical complexity, we also calculate these properties using static and time-dependent density-functional theory. We critically compare these theories and assess their accuracy against available experimental data. The first ionization potentials are consistently well reproduced and are similar for all the fullerenes and methods studied. The electron affinities and first triplet excitation energies show substantial method and geometry dependence. Compared to available experiment, GW-BSE underestimates excitation energies by approximately 0.3 eV while QMC overestimates them by approximately 0.5 eV. We show the GW-BSE errors result primarily from a systematic overestimation of the electron affinities, while the QMC errors likely result from nodal error in both ground and excited state calculations.

36 MATERIALS SCIENCE↗

Quantum and quasi-classical dynamics of the OH + CO → H + CO{sub 2} reaction on a new permutationally invariant neural network potential energy surface

A permutationally invariant global potential energy surface for the HOCO system is reported by fitting a larger number of high-level ab initio points using the newly proposed permutation invariant polynomial-neural network method. The small fitting error (∼5 meV) indicates a faithful representation of the potential energy surface over a large configuration space. Full-dimensional quantum and quasi-classical trajectory studies of the title reaction were performed on this potential energy surface. While the results suggest that the differences between this and an earlier neural network fits are small, discrepancies with state-to-state experimental data remain significant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

Nonlinear interference noise in 100-Gbit s{sup -1} communication lines with the DP-QPSK modulation format

The nonlinear interference noise power was measured experimentally as a function of the signal power and the length of the fibre coherent 100-Gbit s{sup -1} communication line, in which chromatic dispersion is not optically compensated. An expression was derived for the optimal signal power corresponding to a maximal excess of the measured optical signal-to-noise ratio (OSNR) over the OSNR required for conditionally error-free operation. The dependence of signal optimal power measured experimentally well agrees with the theoretical formula derived. (optical information transmission)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗