Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Process Development and Optimization of a Direct Cast U-6Nb 250 mm Hemispherical Component

Direct Casting is the process of casting a near-net shape part of U-6wt%Nb in a multi-zone VIM furnace for subsequent heat treatment and machining in to a final component. This report describes work to further develop a sound technical basis and best practices for mold design and process parameters for the Direct Casting of U-6Nb components with a hemispherical geometry. Specifically, process parameters and mold design are examined in detail for producing a 250 mm diameter hemisphere component. The goal is to efficiently produce a sound casting with a minimum of microporosity and uniform niobium composition. Prior work had tried unsuccessfully to cast this shape in a large single-coil vacuum induction melting (VIM) furnace. These castings had unacceptable levels microporosity and niobium segregation. In this work, this same part was cast in a multi-zone VIM and a sound casting was obtained. Beyond simply casting a sound part, this work aimed to optimize the hot-top design, metal pouring temperature, and mold pole temperature. Sound castings where produced using both a tapered and step hot-top designs. There were slightly lower porosity levels and about 5% better metal usage with the step hot-top so that design slightly better. With the current mold design, which uses a funnel and filter arrangement, there a large amount of superheat loss in the funnel/filter during mold filling. This temperature loss, and the apparent variability in the filling behavior, lead to casting defects in the pole region of several of the castings. The variability and defects were overcome by moving to a higher mold pole temperature (850°C) and a higher metal pour temperature (1500°C). For future work it is believed that a no-funnel design, with the filter integral to the crucible, will be a better and more robust strategy.

42 ENGINEERING↗

Optimization of a gas discharge plasma source for extreme ultraviolet interference lithography at a wavelength of 11 nm

In this work, we report about the optimization of the spectral emission characteristic of a gas discharge plasma source for high-resolution extreme ultraviolet (EUV) interference lithography based on achromatic Talbot self-imaging. The working parameters of the source are optimized to achieve a required narrowband emission spectrum and to fulfill the necessary coherence and intensity requirements. The intense 4f-4d transitions around 11 nm in a highly ionized (Xe{sup 8+}-Xe{sup 12+}) xenon plasma are chosen to provide the working wavelength. This allows us to increase the available radiation intensity in comparison with an in-band EUV xenon emission at 13.5 nm and opens up the possibility to strongly suppress the influence of the 5p-4d transitions at wavelengths between 12 and 16 nm utilizing a significant difference in conditions for optical thickness between 4f-4d and 5p-4d transitions. The effect is achieved by using the admixture of argon to the pinch plasma, which allows keeping the plasma parameters approximately constant while, at the same time, reducing the density of xenon emitters. It is demonstrated that with this approach it is possible to achieve a high intensity 11 nm EUV radiation with a bandwidth of 3%-4% without the use of multilayer mirrors or other additional spectral filters in the vicinity of the working wavelength. The achieved radiation parameters are sufficient for high-performance interference lithography based on the achromatic Talbot effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deblending galaxies with variational autoencoders: A joint multiband, multi-instrument approach

ABSTRACT Blending of galaxies has a major contribution in the systematic error budget of weak-lensing studies, affecting photometric and shape measurements, particularly for ground-based, deep, photometric galaxy surveys, such as the Rubin Observatory Legacy Survey of Space and Time (LSST). Existing deblenders mostly rely on analytic modelling of galaxy profiles and suffer from the lack of flexible yet accurate models. We propose to use generative models based on deep neural networks, namely variational autoencoders (VAE), to learn probabilistic models directly from data. We train a VAE on images of centred, isolated galaxies, which we reuse, as a prior, in a second VAE-like neural network in charge of deblending galaxies. We train our networks on simulated images including six LSST bandpass filters and the visible and near-infrared bands of the Euclid satellite, as our method naturally generalizes to multiple bands and can incorporate data from multiple instruments. We obtain median reconstruction errors on ellipticities and r-band magnitude between ±0.01 and ±0.05, respectively, in most cases, and ellipticity multiplicative bias of 1.6 per cent for blended objects in the optimal configuration. We also study the impact of decentring and prove the method to be robust. This method only requires the approximate centre of each target galaxy, but no assumptions about the number of surrounding objects, pointing to an iterative detection/deblending procedure we leave for future work. Finally, we discuss future challenges about training on real data and obtain encouraging results when applying transfer learning.

Arcelin, Bastien↗

Testing of a 3-D Sonar for Future Deployment to Image Solids on the Floor of Hanford, HLW Conditioning Tanks - 15646

Florida International University (FIU) has tested the capability of 2-D and 3-D sonar systems to image solids settled on the floor of tanks, on the bottom of streams and small rivers, and in 55 gallon drums. FIU developed and successfully tested the Solid-Liquid Interface Monitor (SLIM) for mapping the interface between supernatant and settled solids in several test tanks. SLIM is comprised of: a sonar, a mechanical system for deploying the system into large high-level radioactive waste (HLW) tanks, and imaging programs and algorithms developed at and by FIU faculty and staff. Early testing had the objective to demonstrate the ability of SLIM to image and quantify the height and volume of settled solids on the floor of 1-million-gallon, HLW tanks at Hanford. Testing showed that SLIM: (1) functions accurately in liquid radioactive HLW tank conditions [i.e., caustic (pH>14), warm (up to 45 degrees Centigrade), and highly radioactive]; (2) provides accurate imaging of solids surfaces (1-2% relative error in the height of interfaces); and (3) provides an excellent volume estimation of the solids, thereby allowing engineers to fill tanks closer to the maximum allowed level and optimize solids retrieval; and (4) enables better placement of pumps inside tanks during retrieval to minimize the potential for plugging. The New Hanford technology need is for rapid imaging (even during vigorous mixing) of solids on the floor of conditioning (mixing) tanks. Results of recent successful testing show imaging times under 1 minute, solids volume estimates with <5% error and effective filtering and visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Feasibility of DEIM for retrieving the initial field via dimensionality reduction

When parameter estimation is solved in a high-dimensional space, the dimensionality reduction strategy becomes the primary consideration for alleviating the tremendous computational cost. Here, the discrete empirical interpolation method (DEIM) is explored to retrieve the initial condition (IC) by combining the polynomial chaos (PC) based ensemble Kalman filter (i.e. PC-EnKF), where a non-intrusive PC expansion is considered as a surrogate model in place of the forward model in the prediction step of the ensemble Kalman filter, resulting in fewer forward model integrations but with a comparable accuracy as Monte Carlo-based approaches. The DEIM acts as a hyper-reduction tool to provide the low-dimensional input for the high-dimensional initial field, which can be reconstructed using the information on the sparse interpolation grid points that is adaptively obtained through PC-EnKF data assimilation method. Thus an innovative framework to reconstruct the IC is developed. The detailed procedure at each assimilation iteration includes: the determination of the spatial interpolation points, the estimation of the initial values on the interpolation locations using the optimal observations, and the reconstruction of IC in the full space. The current study uses the reconstruction field of initial conditions of the Navier-Stokes equations as an example to illustrate the efficacy of our method. The experimental results demonstrate the proposed algorithm achieves a satisfactory reconstruction for the initial field. The proposed method helps to extend the applicable area of DEIM in solving inverse problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE HUBBLE SPACE TELESCOPE UV LEGACY SURVEY OF GALACTIC GLOBULAR CLUSTERS. VIII. PRELIMINARY PUBLIC CATALOG RELEASE

The Hubble Space Telescope (HST) UV Legacy Survey of Galactic Globular Clusters (GO-13297) has been specifically designed to complement the existing F606W and F814W observations of the Advanced Camera for Surveys (ACS) Globular Cluster Survey (GO-10775) by observing the most accessible 47 of the previous survey’s 65 clusters in three WFC3/UVIS filters F275W, F336W, and F438W. The new survey also adds super-solar metallicity open cluster NGC 6791 to increase the metallicity diversity. The combined survey provides a homogeneous 5-band data set that can be used to pursue a broad range of scientific investigations. In particular, the chosen UV filters allow the identification of multiple stellar populations by targeting the regions of the spectrum that are sensitive to abundance variations in C, N, and O. In order to provide the community with uniform preliminary catalogs, we have devised an automated procedure that performs high-quality photometry on the new UV observations (along with similar observations of seven other programs in the archive). This procedure finds and measures the potential sources on each individual exposure using library point-spread functions and cross-correlates these observations with the original ACS-Survey catalog. The catalog of 57 clusters we publish here will be useful to identify stars in the different stellar populations, in particular for spectroscopic follow-up. Eventually, we will construct a more sophisticated catalog and artificial-star tests based on an optimal reduction of the UV survey data, but the catalogs presented here give the community the chance to make early use of this HST Treasury survey.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-18C-02: Increasing Amorphous Selenium Thickness in Direct Conversion Flat-Panel Imagers for Contrast-Enhanced Dual-Energy Breast Imaging

Purpose: Contrast-enhanced (CE) breast imaging using iodinated contrast agents requires imaging with x-ray spectra at energies greater than those used in mammography. Optimizing amorphous selenium (a-Se) flat panel imagers (FPI) for this higher energy range may increase lesion conspicuity. Methods: We compare imaging performance of a conventional FPI with 200 μm a-Se conversion layer to a prototype FPI with 300 μm a-Se layer. Both detectors are evaluated in a Siemens MAMMOMAT Inspiration prototype digital breast tomosynthesis (DBT) system using low-energy (W/Rh 28 kVp) and high-energy (W/Cu 49 kVp) x-ray spectra. Detectability of iodinated lesions in dual-energy images is evaluated using an iodine contrast phantom. Effects of beam obliquity are investigated in projection and reconstructed images using different reconstruction methods. The ideal observer signal-to-noise ratio is used as a figure-of-merit to predict the optimal a-Se thickness for CE lesion detectability without compromising conventional full-field digital mammography (FFDM) and DBT performance. Results: Increasing a-Se thickness from 200 μm to 300 μm preserves imaging performance at typical mammographic energies (e.g. W/Rh 28 kVp), and improves the detective quantum efficiency (DQE) for high energy (W/Cu 49 kVp) by 30%. While the more penetrating high-energy x-ray photons increase geometric blur due to beam obliquity in the FPI with thicker a-Se layer, the effect on lesion detectability in FBP reconstructions is negligible due to the reconstruction filters employed. Ideal observer SNR for CE objects shows improvements in in-plane detectability with increasing a-Se thicknesses, though small lesion detectability begins to degrade in oblique projections for a-Se thickness above 500 μm. Conclusion: Increasing a-Se thickness in direct conversion FPI from 200 μm to 300 μm improves lesion detectability in CE breast imaging with virtually no cost to conventional FFDM and DBT. This work was partially supported by a research grant from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron irradiation capability in existing thermal test reactors

In today’s nuclear industry, momentum towards the design, licensing, and construction of advanced nuclear demonstration plants, including fast reactors, is at a remarkably high level. However, there are currently no dedicated fast spectrum irradiation test facilities in the United States to support the development of fast spectrum technologies. As a result, a unique situation is developing where most of these plants will likely be designed by leveraging historic nuclear material technologies, but where the further optimization and advancement is impeded by the lack of fast neutron irradiation test facilities. While these circumstances present a challenge, there are some near-term opportunities that, if seized, can still help develop advanced fast reactor materials to a meaningful level of readiness to support future commercial fast reactors. Here, in this paper, we assess the feasibility of using thermal neutron filtering materials in existing experiment positions in the Advanced Test Reactor (ATR) at Idaho National Laboratory and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory to simulate fast reactor test environments for nonfuel test specimens. Items investigated include the incident neutron flux (both fast and thermal), the total neutron fluence and cumulative atom displacements, helium production rate due to thermal neutron capture in nickel, and the potential impact that the thermal neutron filter material has on the cycle length of a given reactor. It is concluded that while HFIR provides the highest fast flux of all the options investigated, it is limited in the amount of thermal neutron filtering material that can be introduced into an experiment position without significantly affecting the operation of the reactor. Irradiation in Outboard-A positions in the ATR was found to be the most realistic near-term experiment avenue due to having ample space for several capsules in a moderately fast flux.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum capacities of transducers

Abstract High-performance quantum transducers, which faithfully convert quantum information between disparate physical carriers, are essential in quantum science and technology. Different figures of merit, including efficiency, bandwidth, and added noise, are typically used to characterize the transducers’ ability to transfer quantum information. Here we utilize quantum capacity, the highest achievable qubit communication rate through a channel, to define a single metric that unifies various criteria of a desirable transducer. Using the continuous-time quantum capacities of bosonic pure-loss channels as benchmarks, we investigate the optimal designs of generic quantum transduction schemes implemented by transmitting external signals through a coupled bosonic chain. With physical constraints on the maximal coupling rate $${g}_{\max }$$ g max , the highest continuous-time quantum capacity $${Q}^{\max }\approx 31.4{g}_{\max }$$ Q max ≈ 31.4 g max is achieved by transducers with a maximally flat conversion frequency response, analogous to Butterworth electric filters. We further investigate the effect of thermal noise on the performance of transducers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stacked, filtered multi-channel X-ray diode array

There are many types of X-ray diodes used for X-ray flux or spectroscopic measurements and for estimating the spectral shape of the VUV to soft X-ray spectrum. However, a need exists for a low-cost, robust X-ray diode to use for experiments in hostile environments on multiple platforms, and for experiments that utilize forces that may destroy the diode(s). Since the typical proposed use required a small size with a minimal single line-of-sight, a parallel array could not be used. So, a stacked, filtered multi-channel X-ray diode array was developed, called the MiniXRD. To achieve significant cost savings while maintaining robustness and ease of field setup, repair, and replacement, we designed the system to be modular. The filters were manufactured in-house and cover the range from 450 eV to 5000 eV. To achieve the line-of-sight accuracy needed, we developed mounts and laser alignment techniques. We modeled and tested elements of the diode design at NSTec Livermore Operations (NSTec / LO) to determine temporal response and dynamic range, leading to diode shape and circuitry changes to optimize impedance and charge storage. The authors fielded individual and stacked systems at several national facilities as ancillary "ride-along" diagnostics to test and improve the design usability. This paper presents the MiniXRD system performance, which supports consideration as a viable low-costalternative for multiple-channel low-energy X-ray measurements. This diode array is currently at Technical Readiness Level (TRL) 6.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Coded Source Neutron Imaging at the North Carolina State University PULSTAR Reactor

A neutron imaging facility is located on beam-tube #5of the 1-MWth PULSTAR reactor at the North Carolina StateUniversity. An investigation has been initiated to explore theapplication of coded imaging techniques at the facility. Codedimaging uses a mosaic of pinholes to encode an aperture, thusgenerating an encoded image of the object at the detector. Toreconstruct the image recorded by the detector, correspondingdecoding patterns are used. The optimized design of coded masksis critical for the performance of this technique and will dependon the characteristics of the imaging beam. In this work, MonteCarlo (MCNP) simulations were utilized to explore the neededmodifications to the PULSTAR thermal neutron beam to supportcoded imaging techniques. In addition, an assessment of codedmask design has been performed. The simulations indicated thata 12 inch single crystal sapphire filter is suited for such anapplication at the PULSTAR beam in terms of maximizing fluxwith good neutron-to-gamma ratio. Computational simulationsdemonstrate the feasibility of correlation reconstruction methodson neutron transmission imaging. A gadolinium aperture withthickness of 500 m was used to construct the mask using a 38 ×34 URA pattern. A test experiment using such a URA design hasbeen conducted and the point spread function of the system hasbeen measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗

An orbital angular momentum radio communication system optimized by intensity controlled masks effectively: Theoretical design and experimental verification

A system of generating and receiving orbital angular momentum (OAM) radio beams, which are collectively formed by two circular array antennas (CAAs) and effectively optimized by two intensity controlled masks, is proposed and experimentally investigated. The scheme is effective in blocking of the unwanted OAM modes and enhancing the power of received radio signals, which results in the capacity gain of system and extended transmission distance of the OAM radio beams. The operation principle of the intensity controlled masks, which can be regarded as both collimator and filter, is feasible and simple to realize. Numerical simulations of intensity and phase distributions at each key cross-sectional plane of the radio beams demonstrate the collimated results. The experimental results match well with the theoretical analysis and the receive distance of the OAM radio beam at radio frequency (RF) 20 GHz is extended up to 200 times of the wavelength of the RF signals, the measured distance is 5 times of the original measured distance. The presented proof-of-concept experiment demonstrates the feasibility of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms

Purpose: Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. Methods: A 35 Multiplication-Sign 26 cm{sup 2} torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was -15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. Results: The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The Pearson's product-moment correlation coefficients were 0.986 [95% confidence interval (CI): 0.958-0.996] for FBP and 0.985 (95% CI: 0.863-0.998) for IR. Bland-Altman plots showed excellent agreement for all dose levels and lesions sizes with a mean absolute difference of 1.0%{+-} 1.1% for FBP and 2.1%{+-} 3.3% for IR. Conclusions: Human observer performance on a 2AFC lesion detection task in CT with a uniform background can be accurately predicted by a CHO model observer at different radiation dose levels and for both FBP and IR methods.

60 APPLIED LIFE SCIENCES↗

SU-E-I-77: A Noise Reduction Technique for Energy-Resolved Photon-Counting Detectors

Purpose: Finding the optimal energy threshold setting for an energy-resolved photon-counting detector has an important impact on the maximization of contrast-to-noise-ratio (CNR). We introduce a noise reduction method to enhance CNR by reducing the noise in each energy bin without altering the average gray levels in the projection and image domains. Methods: We simulated a four bin energy-resolved photon-counting detector based on Si with a 10 mm depth of interaction. TASMIP algorithm was used to simulate a spectrum of 65 kVp with 2.7 mm Al filter. A 13 mm PMMA phantom with hydroxyapatite and iodine at different concentrations (100, 200 and 300 mg/ml for HA, and 2, 4, and 8 mg/ml for Iodine) was used. Projection-based and Image-based energy weighting methods were used to generate weighted images. A reference low noise image was used for noise reduction purposes. A Gaussian-like weighting function which computes the similarity between pixels of interest was calculated from the reference image and implemented on a pixel by pixel basis for the noisy images. Results: CNR improvement compared to different methods (Charge-Integrated, Photon-Counting and Energy-Weighting) and after noise reduction was highly task-dependent. The CNR improvement with respect to the Charge-Integrated CNR for hydroxyapatite and iodine were 1.8 and 1.5, respectively. In each of the energy bins, the noise was reduced by approximately factor of two without altering their respective average gray levels. Conclusion: The proposed noise reduction technique for energy-resolved photon-counting detectors can significantly reduce image noise. This technique can be used as a compliment to the current energy-weighting methods in CNR optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Multifunctional Thin Film Based X-Ray Intensity Filters for Space-Based Payloads

We report the development, thorough characterizations and space worthiness studies of multifunctional aluminized film as x-ray intensity filter for space-based payloads, suitably designed to place in Sun–Earth Lagrangian (L1) point. The L1 point is the ideal location for uninterrupted observation of Sun to study the solar flares in hard x-rays. For our specific purpose, we make use of two different types of x-ray detectors (e.g., CdTe and CZT) which are generally used for hard x-ray studies in the energy band of 5 to 200 keV. Further, these aforesaid two detectors require specified thermal control characteristic for optimal performance. Aluminization of Kapton films is proposed which would satisfy the thermo-optical and x-ray transmission requirements of the proposed payload. The developed aluminized films are thoroughly studied by field emission scanning electron microscopy and atomic force microscopy techniques for micro-structural characteristic, x-ray diffraction for phase purity, nanoindentation for mechanical integrity at micro-structural length scale and spectrophotometer for thermo-optical properties. X-ray transmission test is carried out with two radioactive sources, namely {sup 55}Fe and {sup 241}Am, with various aluminized Kapton layer combinations. Finally, space worthiness of the aluminized Kapton films is examined by accelerated environments, e.g. humidity, thermal cycling and thermo-vacuum tests.

36 MATERIALS SCIENCE↗