Search NASA⌕ Search

SEARCH · Search NASA

Results for “fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Structural considerations for fabrication and mounting of the AXAF HRMA optics

A methodology is described which minimizes optics distortion in the fabrication, metrology, and launch configuration phases. The significance of finite element modeling and breadboard testing is described with respect to performance analyses of support structures and material effects in NASA's AXAF X-ray optics. The paper outlines the requirements for AXAF performance, optical fabrication, metrology, and glass support fixtures, as well as the specifications for mirror sensitivity and the high-resolution mirror assembly. Analytical modeling of the tools is shown to coincide with grinding and polishing experiments, and is useful for designing large-area polishing and grinding tools. Metrological subcomponents that have undergone initial testing show evidence of meeting force requirements.

Cohen, Lester M.↗

Seal testing of large diameter rocket motors

This investigative program examines leakage testing of elastomeric O-ring seals for a solid rocket casing and provides direction towards an improved nondestructive postassembly test. It also details test equipment for the Space Shuttle systems solid rocket boosters (SRB). The results are useful to designers of hardware for pressure containment vessels which use O-ring seals. Using several subscale seal and groove configuration test fixtures equipped with either two or three O-ring seals in series, seal integrity is investigated with both a pressure decay and flowmeter methods. Both types of test equipment adequately detect the practical range of expected seal leak rates of 1 to 0.0001 sccs. The flowmeter leak test equipment appears to reduce testing time substantially. Limited seal leakage testing is performed on full-sized rocket motor segment seals, a pre-Challenger short stack, providing comparison of bore seals to test specimen bore and face seals. The conclusions are that seal reliability, verified via a performance pressure test, can be affected by temperature, quantity of grease, test pressure, and seal pressure load direction. Potential seal failure scenarios including contamination, seal damage, and sealing surface damage are discussed. Recommendations are made for an improved test procedure.

Moore, N. B.↗

Laboratory simulation of cratering on small bodies

A new technique using external pressure was developed to simulate the lithostatic pressure due to self-gravity of small bodies. A 13-in. diameter cylindrical test chamber with L/D of 1 was fabricated to accommodate firing explosive charges with gas overpressures of up to 6000 psi. The chamber was hydrotested to 9000 psi. The method allows much larger scale factors that can be obtained with existing centrifuges and has the correct spherical geometry of self gravity. A simulant for jointed rock to be used in this fixture was developed using weakly cemented basalt. Various strength/pressure scaling theories can now be examined and tested.

Schmidt, Robert M.↗

Evaluation of an innovative high temperature ceramic wafer seal for hypersonic engine applications

A critical mechanical system in advanced hypersonic engines is the panel-edge seal system that seals gaps between the articulating engine panels and the adjacent engine splitter walls. Significant advancements in seal technology are required to meet the extreme demands placed on the seals, including the simultaneous requirements of low leakage, conformable, high temperature, high pressure, sliding operation. In this investigation, the design, development, analytical and experimental evaluation of a new ceramic wafer seal that shows promise of meeting these demands will be addressed. A high temperature seal test fixture was designed and fabricated to measure static seal leakage performance under engine simulated conditions. Ceramic wafer seal leakage rates are presented for engine-simulated air pressure differentials (up to 100 psi), and temperature (up to 1350 F), sealing both flat and distorted wall conditions, where distortions can be as large as 0.15 inches in only an 18 inch span. Seal leakage rates are low, meeting an industry-established tentative leakage limit for all combinations of temperature, pressure and wall conditions considered. A seal leakage model developed from externally-pressurized gas film bearing theory is also presented. Predicted leakage rates agree favorably with the measured data for nearly all conditions of temperature and pressure. Discrepancies noted at high engine pressure and temperature are attributed to thermally-induced, non-uniform changes in the size and shape of the leakage gap condition. The challenging thermal environment the seal must operate in places considerable demands on the seal concept and material selection. Of the many high temperature materials considered in the design, ceramics were the only materials that met the many challenging seal material design requirements. Of the aluminum oxide, silicon carbide, and silicon nitride ceramics considered in the material ranking scheme developed herein, the silicon nitride class of ceramics ranked the highest because of their high temperature strength; resistance to the intense heating rates; resistance to hydrogen damage; and good structural properties. Baseline seal feasibility has been established through the research conducted in this investigation. Recommendations for future work are also discussed.

Steinetz, Bruce M.↗

Ceramic susceptor for induction bonding of metals, ceramics, and plastics

A thin (.005) flexible ceramic susceptor (carbon) was discovered. It was developed to join ceramics, plastics, metals, and combinations of these materials using a unique induction heating process. Bonding times for laboratory specimens comparing state of the art technology to induction bonding were cut by a factor of 10 to 100 times. This novel type of carbon susceptor allows for applying heat directly and only to the bondline without heating the entire structure, supports, and fixtures of a bonding assembly. The ceramic (carbon film) susceptor produces molten adhesive or matrix material at the bond interface. This molten material flows through the perforated susceptor producing a fusion between the two parts to be joined, which in many instances has proven to be stronger than the parent material. Bonding can be accomplished in 2 minutes on areas submitted to the inductive heating. Because a carbon susceptor is used in bonding carbon fiber reinforced plastics and ceramics, there is no radar signature or return making it an ideal process for joining advanced aerospace composite structures.

Fox, Robert L.↗

Analysis, design, and experimental results for lightweight space heat receiver canisters, phase 1

Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).

Schneider, Michael G.↗

Ramp Technology and Intelligent Processing in Small Manufacturing

To address the issues of excessive inventories and increasing procurement lead times, the Navy is actively pursuing flexible computer integrated manufacturing (FCIM) technologies, integrated by communication networks to respond rapidly to its requirements for parts. The Rapid Acquisition of Manufactured Parts (RAMP) program, initiated in 1986, is an integral part of this effort. The RAMP program's goal is to reduce the current average production lead times experienced by the Navy's inventory control points by a factor of 90 percent. The manufacturing engineering component of the RAMP architecture utilizes an intelligent processing technology built around a knowledge-based shell provided by ICAD, Inc. Rules and data bases in the software simulate an expert manufacturing planner's knowledge of shop processes and equipment. This expert system can use Product Data Exchange using STEP (PDES) data to determine what features the required part has, what material is required to manufacture it, what machines and tools are needed, and how the part should be held (fixtured) for machining, among other factors. The program's rule base then indicates, for example, how to make each feature, in what order to make it, and to which machines on the shop floor the part should be routed for processing. This information becomes part of the shop work order. The process planning function under RAMP greatly reduces the time and effort required to complete a process plan. Since the PDES file that drives the intelligent processing is 100 percent complete and accurate to start with, the potential for costly errors is greatly diminished.

Rentz, Richard E.↗

LDEF mechanical systems

Following LDEF retrieval, a number of studies were made of mechanical hardware and structure flown on the LDEF. The primary objectives are to determine the effects of long term space exposure on (1) mechanisms either used on LDEF or as part of individual experiments; (2) LDEF structural components; and (3) fasteners. Results from examination and testing of LDEF structure, fasteners, LDEF end support beam, environment exposure control canisters, experiment tray clamps, LDEF grapple fixtures, and viscous damper are presented. The most significant finding is the absence of space exposure related cold welding. The instances of seizure or removal difficulties initially attributed to cold welding were shown to have resulted from installation galling damage or improper removal techniques. Widespread difficulties encountered with removal of stainless steel fasteners underscore the need for effective thread lubrication schemes to ensure successful application of proposed orbital replacement units onboard Space Station Freedom.

W Steve Spear↗

Neutron, gamma ray, and temperature effects on the electrical characteristics of thyristors

Experimental data showing the effects of neutrons, gamma rays, and temperature on the electrical and switching characteristics of phase-control and inverter-type SCR's are presented. The special test fixture built for mounting, heating, and instrumenting the test devices is described. Four SCR's were neutron irradiated at 300 K and four at 365 K for fluences up to 3.2 x 10 exp 13 n/sq. cm, and eight were gamma irradiated at 300 K only for gamma doses up to 5.1 Mrads. The electrical measurements were made during irradiation and the switching measurements were made only before and after irradiation. Radiation induced crystal defects, resulting primarily from fast neutrons, caused the reduction of minority carrier lifetime through the generation of R-G centers. The reduction in lifetime caused increases in the on-state voltage drop and in the reverse and forward leakage currents, and decreases in the turn-off time.

Frasca, A. J.↗

Performance of fuselage pressure structure

There are currently more than 1,000 Boeing airplanes around the world over 20 years old. That number is expected to double by the year 1995. With these statistics comes the reality that structural airworthiness will be in the forefront of aviation issues well into the next century. The results of previous and recent test programs Boeing has implemented to study the structural performance of older airplanes relative to pressurized fuselage sections are described. Included in testing were flat panels with multiple site damage (MSD), a full-scale 737 and 2 747s as well as panels representing a 737 and 777, and a generic aircraft in large pressure-test fixtures. Because damage is a normal part of aging, focus is on the degree to which structural integrity is maintained after failure or partial failure of any structural element, including multiple site damage (MSD), and multiple element damage (MED).

Aging Aircraft↗

Mechanical properties of brittle materials

Brittle materials are difficult to tensile test because of gripping problems. They either crack in conventional grips or they are crushed. Furthermore, they may be difficult to make into tensile specimens having, for example, threated ends or donut shapes. To overcome the problem, simple rectangular shapes can be used in bending (i.e., a simple beam) in order to obtain the modulus of rupture and the elastic modulus. The equipment necessary consists of a fixture for supporting the specimens horizontally at two points, these points contact points being rollers which are free to rotate. The force necessary to bend the specimen is produced by a tup attached to the crosshead of an Instron machine. Here, the experimental procedure is explained.

Cornwell, L. R.↗

Numerical analysis of the Iosipescu specimen for composite materials

A finite element analysis of the Iosipescu shear tests for unidirectional and cross-ply composites is presented. It is shown that an iterative analysis procedure must be used to model the fixture-specimen kinematics. The correction factors which are needed to compensate for the nonuniformity of stress distribution in calculating shear modulus are shown to be dependent on the material orthotropic ratio and the finite element loading models. Test section strain distributions representative of typical graphite-epoxy specimens are also presented.

Ho, H.↗

Composite material shear property measurement using the Iosipescu specimen

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Finite element analysis and moire interferometry are used to assess the uniformity of the shear stress field in the test section of unidirectional and cross-ply graphite-epoxy composites. The nonuniformity of the strain field and the sensitivity of some fiber orientations to the specimen/fixture contact mechanics are discussed. The shear responses obtained for unidirectional and cross-ply graphite-epoxy composites are discussed and problems associated with anomalous behavior are addressed. An experimental determination of the shear response of a range of material systems using strain gage instrumentation and moire interferometry is performed.

Ho, Henjen↗

A comparison of three popular test methods for determining the shear modulus of composite materials

Three popular shear tests (the 10 degree off-axis, the plus or minus 45 degree tensile, and the Iosipescu specimen tested in the modified Wyoming fixture) for shear modulus measurement are evaluated for a graphite-epoxy composite material system. A comparison of the shear stress-strain response for each test method is made using conventional strain gage instrumentation and moire interferometry. The uniformity and purity of the strain fields in the test sections of the specimens are discussed, and the shear responses obtained from each test technique are presented and compared. For accurate measurement of shear modulus, the 90 degree Iosipescu specimen is recommended.

Ho, Henjen↗

An assessment on the validity of toughness as a balloon film discriminator

Uniaxial and ball burst toughness for eight commercial polyethylene balloon films have been investigated and compared. Uniaxial toughness was measured in both machine and transverse directions using a rectangular sample 25.4 mm wide by 50.8 mm gage length with an average nominal thickness of 20.32 microns (0.8 mils). Ball burst toughness was measured using a ball burst test fixture with 127 mm hole diameter and 50.8 mm ball diameter resulting in a 0.4 ball to hole diameter ratio. Both the size and shape of the deformed area were observed and the ball burst toughness was calculated based on the deformed area of the film instead of the full area. Specimens were tested at 23 C and -80 C and cross head speed was maintained at 508 mm per minute. The uniaxial toughness were in general, higher than the ball burst toughness. The toughness of the films varied from 12 to 365 MPa when measured uniaxially and from 24 to 73 MPa when measured in the ball burst test. Further investigation showed an apparent correlation between film performance in flight as measured by its stress index and its toughness.

Said, Magdi A.↗

High-performance packaging for monolithic microwave and millimeter-wave integrated circuits

Packaging schemes are developed that provide low-loss, hermetic enclosure for enhanced monolithic microwave and millimeter-wave integrated circuits. These package schemes are based on a fused quartz substrate material offering improved RF performance through 44 GHz. The small size and weight of the packages make them useful for a number of applications, including phased array antenna systems. As part of the packaging effort, a test fixture was developed to interface the single chip packages to conventional laboratory instrumentation for characterization of the packaged devices.

Shalkhauser, K. A.↗

A comparison of three shear test methods for composite materials

A graphite-epoxy composite material system is used to evaluate the performance of three popular shear tests - the 10-deg off-axis, the +/-45-deg tension, and the Iosipescu specimen tested in the modified Wyoming fixture. A comparison of the shear stress-strain response for each test method is made using a conventional strain gage instrument and moire interferometry. The uniformity and purity of the strain fields in the test sections of the specimens are discussed, and the shear responses obtained from each test are presented and compared. It is shown that the shear stress-strain responses obtained by instrumenting only one face of the 90-deg Iosipescu specimen could give erroneous results. The +/-45-deg tensile and 0-deg Iosipescu specimens were not affected by front-to-back face shear strain variations. Correction factors could be applied to bring all responses together, within the limits of the material uniformity, which was itself documented in the moire fringe patterns.

Ho, H.↗

An evaluation of the Iosipescu specimen for composite materials shear property measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. A linear finite element model of the specimen is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon strain gage measurements used for the determination of composite shear moduli. Based upon test results from graphite-epoxy laminates, the proximity of the load introduction point to the test section and the material orthotropy greatly influence the individual gage readings, however, shear modulus determination is not significantly affected by the lack of pure shear. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors are determined for the region occupied by the strain gage rosette. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and spurious shear stress-strain curves. The discovery of specimen twisting explains the apparently inconsistent shear property data found in the literature. Recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed.

Morton, J.↗