Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Solar Array Mast Imagery Discussion for ISIW

SAW Mast inspection background: In 2012, NASA's Flight Safety Office requested the Micro Meteoroid and Orbital Debris (MMOD) office determine the probability of damage to the Solar Array Wing (SAW) mast based on the exposure over the life time of the ISS program. As part of the risk mitigation of the potential MMOD strikes. ISS Program office along with the Image Science and Analysis Group (ISAG) began developing methods for imaging the structural components of the Mast.

Kilgo, Gary↗

Systems and Methods for Advanced Rapid Imaging and Analysis for Earthquakes

Many embodiments provide a hybrid data processing system (HySDS) of an end-to-end geodetic imaging data system enabling near-real-time science, assessment, response, and rapid recovery. The HySDS may be an operation data processing system that integrates data from many different geodetic data sources and/or sensors, including interferometric synthetic aperture radar (InSAR), GPS, pixel tracking, seismology, and/or modeling, and processes the data to generate actionable high quality science data products. The HySDS may provide for an automated imaging and analysis capabilities that is able to handle the imminent increases in raw data from new and existing geodetic monitoring sensor systems.

Owen, Susan Ethel↗

Apparatus, method and system for imaging and utilization of SEM charged particles

A scanning electron microscope (SEM) system includes an SEM objective that emits an electron beam toward a sample, causing emission of charged particles including secondary electrons, Auger electrons, backscattered electrons, anions and cations. The SEM system includes electron optics elements that are configured to establish electric fields around the sample that accelerate charged particles toward a detector. A two-dimensional distribution of locations of incidence of the charged particles on the detector is indicative of energies of the charged particles and their emission angles from the sample. A three-dimensional spatial distribution of charged particles emitted from the sample is recovered by performing an Abel transform over the distribution on the detector. The energies and emission angles of the charged particles are then determined from the three-dimensional spatial distribution.

42 ENGINEERING↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗

System and method for adaptable lidar imaging

The present disclosure relates to an adaptive light detection and ranging (lidar) system. In one implementation the system may have a controller and lidar control software in communication with the controller. A focusing control subsystem may be included which is configured to control focusing and detection of a laser beam. An emitter/detector subsystem may be included which is responsive to commands from the focusing control subsystem to generate at least one laser beam which is used to implement a plurality of different focusing modes for imaging a scene.

Panas, Robert Matthew↗

THE SYSTEMATIC ERROR TEST FOR PSF CORRECTION IN WEAK GRAVITATIONAL LENSING SHEAR MEASUREMENT BY THE ERA METHOD BY IDEALIZING PSF

We improve the ellipticity of re-smeared artificial image (ERA) method of point-spread function (PSF) correction in a weak lensing shear analysis in order to treat the realistic shape of galaxies and the PSF. This is done by re-smearing the PSF and the observed galaxy image using a re-smearing function (RSF) and allows us to use a new PSF with a simple shape and to correct the PSF effect without any approximations or assumptions. We perform a numerical test to show that the method applied for galaxies and PSF with some complicated shapes can correct the PSF effect with a systematic error of less than 0.1%. We also apply the ERA method for real data of the Abell 1689 cluster to confirm that it is able to detect the systematic weak lensing shear pattern. The ERA method requires less than 0.1 or 1 s to correct the PSF for each object in a numerical test and a real data analysis, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

A Semi-Supervised Learning Method for the Identification of Bad Exposures in Large Imaging Surveys

As the data volume of astronomical imaging surveys rapidly increases, traditional methods for image anomaly detection, such as visual inspection by human experts, are becoming impractical. We introduce a machine-learning-based approach to detect poor-quality exposures in large imaging surveys, with a focus on the DECam Legacy Survey (DECaLS) in regions of low extinction (i.e., E ( B − V ) < 0.04 ). Our semi-supervised pipeline integrates a vision transformer (ViT), trained via self-supervised learning (SSL), with a k-Nearest Neighbor (kNN) classifier. We train and validate our pipeline using a small set of labeled exposures observed by surveys with the Dark Energy Camera (DECam). A clustering-space analysis of where our pipeline places images labeled in good and bad categories suggests that our approach can efficiently and accurately determine the quality of exposures. Applied to new imaging being reduced for DECaLS Data Release 11, our pipeline identifies 780 problematic exposures, which we subsequently verify through visual inspection. Being highly efficient and adaptable, our method offers a scalable solution for quality control in other large imaging surveys.

Luo, Yufeng (ORCID:0000000246230683)↗

X-ray Moiré deflectometry using synthetic reference images

Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, the method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-C-BRA-03: An Automated and Quick Contour Errordetection for Auto Segmentation in Online Adaptive Radiotherapy

Purpose: To develop a tool that can quickly and automatically assess contour quality generated from auto segmentation during online adaptive replanning. Methods: Due to the strict time requirement of online replanning and lack of ‘ground truth’ contours in daily images, our method starts with assessing image registration accuracy focusing on the surface of the organ in question. Several metrics tightly related to registration accuracy including Jacobian maps, contours shell deformation, and voxel-based root mean square (RMS) analysis were computed. To identify correct contours, additional metrics and an adaptive decision tree are introduced. To approve in principle, tests were performed with CT sets, planned and daily CTs acquired using a CT-on-rails during routine CT-guided RT delivery for 20 prostate cancer patients. The contours generated on daily CTs using an auto-segmentation tool (ADMIRE, Elekta, MIM) based on deformable image registration of the planning CT and daily CT were tested. Results: The deformed contours of 20 patients with total of 60 structures were manually checked as baselines. The incorrect rate of total contours is 49%. To evaluate the quality of local deformation, the Jacobian determinant (1.047±0.045) on contours has been analyzed. In an analysis of rectum contour shell deformed, the higher rate (0.41) of error contours detection was obtained compared to 0.32 with manual check. All automated detections took less than 5 seconds. Conclusion: The proposed method can effectively detect contour errors in micro and macro scope by evaluating multiple deformable registration metrics in a parallel computing process. Future work will focus on improving practicability and optimizing calculation algorithms and metric selection.

60 APPLIED LIFE SCIENCES↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated gauge reading and related systems, methods, and devices

Computing devices and methods for reading gauges are disclosed. A gauge reading method includes capturing image data corresponding to a captured image of one or more gauges, detecting one or more gauges in the captured image, cropping a detected gauge in the captured image to provide a use image including the detected gauge, and classifying the detected gauge to correlate the detected gauge with a template image. The gauge reading method also includes attempting to perform feature detection rectification on the use image to produce a rectified image of the detected gauge, performing template matching rectification on the use image to produce the rectified image responsive to a failure to perform the feature detection rectification, and estimating a gauge reading responsive to the rectified image. A computing device may implement at least a portion of a gauge reading method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Wavelength Guided Self-Supervised Feature Learning For Galaxy Cluster Richness Estimate

Most galaxies in the nearby Universe are gravitationally bound to a cluster or group of galaxies. Their optical contents, such as optical richness, are crucial for understanding the co-evolution of galaxies and large-scale structures in modern astronomy and cosmology. The determination of optical richness can be challenging. We propose a self-supervised approach for estimating optical richness from multi-band optical images. The method uses the data properties of the multi-band optical images for pre-training, which enables learning feature representations from a large but unlabeled dataset. We apply the proposed method to the Sloan Digital Sky Survey. The result shows our estimate of optical richness lowers the mean absolute error and intrinsic scatter by 11.84% and 20.78%, respectively, while reducing the need for labeled training data by up to 60%. We believe the proposed method will benefit astronomy and cosmology, where a large number of unlabeled multi-band images are available, but acquiring image labels is costly.

79 ASTRONOMY AND ASTROPHYSICS↗

Using Plane Pulsed Acoustic Waves in Devices with Phased Gratings for Ultrasonic Imaging in Layered Media

A new method of constructing ultrasonic images in layered media is proposed that is based on the radiation and reception of plane pulsed waves at various angles. Upon passage via a set of layers, plane pulsed waves do not change their shape and direction in the imaged region, which eliminates the need for detailed analysis of wave propagation in intermediate layers. It is shown that, in the absence of a priori information on the thicknesses and acoustical parameters of layers or the results of their measurement, the proposed method allows images to be obtained at a spatial resolution corresponding to the theoretical limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm.sup.2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 .mu.m resolution for an image of the field of view.

47 OTHER INSTRUMENTATION↗