Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Sputtered p-Type Cu x Zn 1– x S Back Contact to CdTe Solar Cells

As thin-film cadmium telluride (CdTe) solar cells gain prominence, one particular challenge is optimizing contacts and their interfaces to transfer charge without losses in efficiency. Back contact recombination is still significant and will prevent CdTe solar technology from reaching its full potential in device efficiency, and transparent back contacts have not been developed for bifacial solar technology or multijunction solar cells. To address these challenges, here we investigate sputtered Cu x Zn 1– x S as a p-type semi-transparent back contact material to thin-film polycrystalline CdTe solar cells at Cu concentrations x = 0.30, 0.45, and 0.60. This material is selected for its high hole conductivity (160–2120 S cm –1 ), wide optical band gap (2.25–2.75 eV), and variable ionization potential (approximately 6–7 eV) that can be aligned to that of CdTe. We report that without device optimization, CdTe solar cells with these Cu x Zn 1– x S back contacts perform as well as control cells with standard ZnTe:Cu back contacts. We observe no reduction in external quantum efficiency, low contact barrier heights of approximately 0.3 eV, and carrier lifetimes on par with those of baseline CdTe. These cells are relatively stable over one year in air, with V OC and efficiency of the x = 0.30 cell decreasing by only 1 and 3%, respectively. Using scanning electron microscopy and scanning transmission electron microscopy to investigate the Cu x Zn 1– x S/CdTe interface, we demonstrate that the Cu x Zn 1– x S layer segregates into a bilayer of Cu-Te-S and Zn-Cd-S, and thermodynamic reaction calculations support these findings. Despite its bilayer formation, the back contact still functions well. This investigation explains some of the physical mechanisms governing the device stack, inspires future work to understand interfacial chemistry and charge transfer, and elicits optimization to achieve higher-efficiency CdTe cells.

14 SOLAR ENERGY↗

Fueling Studies on the Lithium Tokamak Experiment

Lithium plasma facing components reduce the flux of "recycled" particles en- tering the plasma edge from the plasma facing components. This results in increased external fueling requirements and provides the opportunity to control the magnitude and distribution of the incoming particle flux. It has been pre- dicted that the plasma density profile will then be determined by the deposition profile of the external fueling, rather than dominated by the recycled particle flux. A series of experiments on the Lithium Tokamak Experiment demonstrate that lithium wall coatings facilitate control of the neutral and plasma particle in- ventories. With fresh lithium coatings and careful gas injection programming, over 90% of the injected particle inventory can be absorbed in the lithium wall during a discharge. Furthermore, dramatic changes in the fueling requirements and plasma parameters were observed when lithium coatings were applied. This is largely due to the elimination of water as an impurity on the plasma facing components. A Molecular Cluster Injector (MCI) was developed for the fueling of LTX plas- mas. The MCI uses a supersonic nozzle, cooled to liquid nitrogen temperatures, to create the conditions necessary for molecular cluster formation. It has been predicted that molecular clusters will penetrate deeper into plasmas than gas- phase molecules via a reduced ionization cross-section and by improving the collimation of the neutral jet. Using an electron beam diagnostic, the densities of the cryogenic MCI are measured to be an order of magnitude higher than in the room-temperature jets formed with the same valve pressure. This indi- cates increased collimation relative to what would be expected from ideal gas dynamics alone. A systematic study of the fueling efficiencies achieved with the LTX fueling systems is presented. The fueling efficiency of the Supersonic Gas Injector (SGI) is demonstrated to be strongly dependent on the distance between the nozzle and plasma edge. The fueling efficiency of the gas puffer was improved by the addition of a guide tube to keep the gas flow collimated and directed towards the plasma edge. Contrary to results reported on other devices, the MCI yields fueling efficiencies that are at best equal to the SGI. This suggests that any enhanced penetration from cluster formation is nullified by the reduced velocity of the cryogenic gas. Furthermore, at very high neutral fluxes, the fueling efficiency of the MCI dropped off dramatically, suggesting that the build-up of pressure in the scrape-off-layer is producing a self-shielding effect. All of these results are consistent with the idea that the best gas-based fueling source is one that brings highly directed neutrals to the plasma edge, without being scattered or ionized in the scrape-off-layer. The density profiles of LTX plasmas are measured during external fueling with the gas puffer, SGI, and cryogenic MCI. While the density profile amplitude increases with higher fueling rates, the shape of the profile remains constant. This suggests that particle transport is such that differences in the neutral deposition cannot be discerned. The density profiles are consistently hollow, suggesting a region of reduced particle transport in the core of LTX plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-199: Comparison Between Acuros XB and AAA in Homogeneous Phantoms for Volumetric Modulated Arc Therapy Plans

Purpose: To investigate the differences among Acuros XB (AXB) with dose-to-water report mode (AXBw), AXB with dose-to-medium report mode (AXBm) and Anisotropic Analytical Algorithm (AAA), in homogeneous phantoms and for volumetric modulated arc therapy (VMAT) plans. Methods: Nineteen clinically applied VMAT plans were transplanted to a Delta4 phantom and an I’mRT phantom to generate phantom plans, respectively. Each plan was calculated using AXBw, AXBm and AAA, respectively, utilizing the distributed calculation framework (DCF), and the calculation times were recorded. Each plan was delivered by the TrueBeam linear accelerator and measured using the Delta4 phantom and ionization chamber, respectively. The 3D gamma pass rates and point dose deviations were compared among AXBw, AXBm and AAA. Results: In terms of the gamma pass rates with both the criteria of 3 mm/3% (3 mm distance-to-agreement, 3% dose difference) and 2 mm/2%, AXBm demonstrated the significantly worst results, and no significant difference was found between AXBw and AAA. In terms of the point dose, AXBw was slightly closer to the measured dose compared with AAA, and AXBm demonstrated the maximum dose deviation from the measured dose. Moreover, AXB calculation consumed comparable time when the DCF was not busy, and consumed significantly less time when the DCF was busy. Conclusion: In the homogeneous phantoms and for the VMAT plans, AXBw has the best dose accuracy, and AAA is comparable to or slightly worse than AXBw, wheras AXBm has the worst dose accuracy. Furthermore, AXB has higher calculation efficiency than AAA.

60 APPLIED LIFE SCIENCES↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Local Electronic Structure Changes in Polycrystalline CdTe with CdCl 2 Treatment and Air Exposure

Postdeposition CdCl 2 treatment of polycrystalline CdTe is known to increase the photovoltaic device efficiency. However, the precise chemical, structural, and electronic changes that underpin this improvement are still debated. In this work, spectroscopic photoemission electron microscopy was used to spatially map the vacuum level and ionization energy of CdTe films, enabling the identification of electronic structure variations between grains and grain boundaries (GBs). In vacuo preparation and inert transfer of oxide-free CdTe surfaces isolated the separate effects of CdCl 2 treatment and ambient oxygen exposure. Qualitatively, grain boundaries displayed lower work function and downward band bending relative to grain interiors, but only after air exposure of CdCl 2 -treated CdTe. Analysis of numerous space charge regions at grain boundaries showed an average depletion width of 290 nm and an average band bending magnitude of 70 meV, corresponding to a GB trap density of 10 11 cm –2 and a net carrier density of 10 15 cm –3 . Finally, these results suggest that both CdCl 2 treatment and oxygen exposure may be independently tuned to enhance the CdTe photovoltaic performance by engineering the interface and bulk electronic structure.

36 MATERIALS SCIENCE↗

Efficient calculation of carrier scattering rates from first principles

Abstract The electronic transport behaviour of materials determines their suitability for technological applications. We develop a computationally efficient method for calculating carrier scattering rates of solid-state semiconductors and insulators from first principles inputs. The present method extends existing polar and non-polar electron-phonon coupling, ionized impurity, and piezoelectric scattering mechanisms formulated for isotropic band structures to support highly anisotropic materials. We test the formalism by calculating the electronic transport properties of 23 semiconductors, including the large 48 atom CH 3 NH 3 PbI 3 hybrid perovskite, and comparing the results against experimental measurements and more detailed scattering simulations. The Spearman rank coefficient of mobility against experiment ( r s = 0.93) improves significantly on results obtained using a constant relaxation time approximation ( r s = 0.52). We find our approach offers similar accuracy to state-of-the art methods at approximately 1/500th the computational cost, thus enabling its use in high-throughput computational workflows for the accurate screening of carrier mobilities, lifetimes, and thermoelectric power.

97 MATHEMATICS AND COMPUTING↗

Anomalous spectral dependence of optical polarization and its impact on spin detection in InGaAs/GaAs quantum dots

We show that circularly polarized emission light from InGaAs/GaAs quantum dot (QD) ensembles under optical spin injection from an adjacent GaAs layer can switch its helicity depending on emission wavelengths and optical excitation density. We attribute this anomalous behavior to simultaneous contributions from both positive and negative trions and a lower number of photo-excited holes than electrons being injected into the QDs due to trapping of holes at ionized acceptors and a lower hole mobility. Our results call for caution in reading out electron spin polarization by optical polarization of the QD ensembles and also provide a guideline in improving efficiency of spin light emitting devices that utilize QDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Macroscopic scaling of high-order harmonics generated by two-color optimized waveforms in a hollow waveguide

We present the macroscopic scaling of high harmonics generated by two-color laser pulses interacting with Ne gas in a hollow waveguide. We demonstrate that the divergence of harmonics is inversely proportional to the waveguide radius and harmonic yields are proportional to the square of the waveguide radius when the gas pressure and waveguide length are chosen to meet the phase-matching condition. We also show that harmonic yields are inversely proportional to the ionization level of the optimized two-color waveform with proper gas pressure if waveguide radius and length are fixed. These scaling relations would help experimentalists find phase-matching conditions to efficiently generate tabletop high-flux coherent soft x rays for applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commercial Buck Converters and Custom Coil Development for the ATLAS Inner Detector Upgrade

A new generation of higher gain commercial buck converters built using advanced short channel CMOS processes has the potential to operate in the Atlas Inner Detector at the Super Large Hadron Collider (sLHC). This approach would inherently be more efficient than the existing practice of locating the power conversion external to the detector. The converters must operate in a large magnetic field and be able to survive both high doses of ionizing radiation and large neutron fluences. The presence of a large magnetic field necessitates the use of an air core inductor which is developed and discussed here. Noise measurements will be made to investigate the effect of the high frequency switching of the buck converter on the sensitive front end electronics. Radiation hardness of selected buck converters and mosfets will also be reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

DOE Plasma Science Center - Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems (Final Report DE-SC0001939)

Low temperature plasmas (LTPs) are the plasmas of electron-volt (eV) physics and eV technologies. LTPs have characteristic electron temperatures of a few eV and fractional ionizations that are typically small. Since LTPs have electron temperatures commensurate with the threshold energies of excited states in neutral atoms and molecules, power transfer from electrons to these atoms and molecules efficiently produces activated species (e.g., radicals, excited states, photons). Acceleration of ions in the sheaths of LTPs to energies of tens to hundreds of eV enable activation of surface modifying processes – sputtering, etching, deposition. With such properties, LTPs are often and beneficially used in technological devices, ranging from etching and deposition in microelectronics and solar cell fabrication, to hardening of surgical instruments. LTPs harbor fundamental science issues that are intellectually challenging and rewarding. At the same time, there are enormous societal benefits that are enabled by LTPs. The entire present-day and future information technology infrastructure owes its very existence to LTPs. Renewable energy sources, such as solar cell arrays, could not be economically produced in the absence of deposition and etching by LTPs. In acknowledgment of the importance of LTPs, the DOE Office of Fusion Energy Sciences supported the Plasma Science Center for Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems from August 2009 to July 2021, consisting of an initial 5-year grant, 3 funded extensions and 2 no-cost extensions. This is the final report of the Center in which the productivity of the Center is discussed in terms of publications, impact and personnel. High-lights of the research performed in the Center are provided.

36 MATERIALS SCIENCE↗

Start-to-end simulation of a Smith-Purcell free electron laser

Terahertz (THz) radiation has generated much recent interest due to its ability to penetrate deep into many organic materials without the damage associated with ionizing radiations. Smith-Purcell free-electron lasers (SPFELs) offer a viable path toward generating copious amounts of narrow-band THz radiation. In this paper we present numerical simulations, performed with the conformal finite-difference time-domain electromagnetic solver VORPAL of a SPFEL operating in the superradiant regime. We first explore the standard (single grating) configuration and investigate the impact of incoming beamparameters. We also present a new concept based a double grating configuration to efficiently bunch the electron beam, followed by a single grating to produce super-radiant SP radiation.

43 PARTICLE ACCELERATORS↗

Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements

Purpose: PTW’s Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results. In this study, (1) 1000 SRS collection efficiencies were measured as a function of pulse frequency and pulse dose, (2) two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: To obtain collection efficiencies, the OCTAVIUS 1000 SRS was used to measure open fields of varying pulse frequency, pulse dose, and beam energy with results normalized to air-filled chamber measurements. Changes in ratios of 1000 SRS to chamber measured dose were attributed to changing collection efficiencies, which were then correlated to pulse parameters using regression analysis. The usefulness of the derived corrections was then evaluated using 6 MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam (Varian Medical Systems) linear accelerator equipped with a high definition multileaf collimator. For the first correction, MATLAB software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency, and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction the MU/min in the daily 1000 SRS calibration was chosen to match the average MU/min of the volumetric modulated arc therapy plan. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: Collection efficiencies correlated linearly to pulse dose, while correlations with pulse frequency were less defined, generally increasing as pulse frequency decreased. After complex MATLAB corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6 MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6 MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex MATLAB corrections. Conclusions: OCTAVIUS 1000 SRS ion recombination effects have little effect on 6 MV measurements. However, the effect could potentially be clinically significant for higher pulse dose unflattened beams when using tighter gamma tolerances, especially when small aperture sizes are used, as is common for SRS/SBRT. In addition, ion recombination effects are strongly correlated to changing MU/min, therefore MU/min used in daily 1000 SRS calibrations should be matched to the expected average MU/min of the IMRT plan.

60 APPLIED LIFE SCIENCES↗

IMRT Quality Assurance Using a Second Treatment Planning System

We used a second treatment planning system (TPS) for independent verification of the dose calculated by our primary TPS in the context of patient-specific quality assurance (QA) for intensity-modulated radiation therapy (IMRT). QA plans for 24 patients treated with inverse planned dynamic IMRT were generated using the Nomos Corvus TPS. The plans were calculated on a computed tomography scan of our QA phantom that consists of three Solid Water slabs sandwiching radiochromic films, and an ion chamber that is inserted into the center slab of the phantom. For the independent verification, the dose was recalculated using the Varian Eclipse TPS using the multileaf collimator files and beam geometry from the original plan. The data was then compared in terms of absolute dose to the ion chamber volume as well as relative dose on isodoses calculated at the film plane. The calculation results were also compared with measurements performed for each case. When comparing ion chamber doses, the mean ratio was 0.999 (SD 0.010) for Eclipse vs. Corvus, 0.988 (SD 0.020) for the ionization chamber measurements vs. Corvus, and 0.989 (SD 0.017) for the ionization chamber measurements vs. Eclipse. For 2D doses with gamma histogram, the mean value of the percentage of pixels passing the criteria of 3%, 3 mm was 94.4 (SD 5.3) for Eclipse vs. Corvus, 85.1 (SD 10.6) for Corvus vs. film, and 93.7 (SD 4.1) for Eclipse vs. film; and for the criteria of 5%, 3 mm, 98.7 (SD 1.5) for Eclipse vs. Corvus, 93.0 (SD 7.8) for Corvus vs. film, and 98.0 (SD 1.9) for Eclipse vs. film. We feel that the use of the Eclipse TPS as an independent, accurate, robust, and time-efficient method for patient-specific IMRT QA is feasible in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗

AGN ACTIVITY AND THE MISALIGNED HOT ISM IN THE COMPACT RADIO ELLIPTICAL NGC 4278

The analysis of a deep (579 ks) Chandra ACIS pointing of the elliptical galaxy NGC 4278, which hosts a low-luminosity active galactic nucleus (AGN) and compact radio emission, allowed us to detect extended emission from hot gas out to a radius of {approx}5 kpc, with 0.5-8 keV luminosity of 2.4 Multiplication-Sign 10{sup 39} erg s{sup -1}. The emission is elongated in the NE-SW direction, misaligned with respect to the stellar body, and aligned with the ionized gas and with the Spitzer IRAC 8 {mu}m non-stellar emission. The nuclear X-ray luminosity decreased by a factor of {approx}18 since the first Chandra observation in 2005, a dimming that enabled the detection of hot gas even at the position of the nucleus. The gas shows a significantly larger temperature (kT = 0.75 keV) in both the projected and deprojected profiles in the inner {approx}300 pc than in the surrounding region, where it stays at {approx}0.3 keV, a value lower than expected from standard gas heating assumptions. The nuclear X-ray emission is consistent with that of a low radiative efficiency accretion flow, accreting mass at a rate close to the Bondi rate; estimates of the power of the nuclear jets require that the accretion rate is not largely reduced with respect to the Bondi rate. Among possible origins for the central large hot gas temperature, such as gravitational heating from the central massive black hole and a recent AGN outburst, interaction with the nuclear jets seems more likely, especially if the latter remain confined, and heat the nuclear region frequently. The unusual hot gas distribution on the galactic scale could be due to the accreting cold gas triggering the cooling of the hot phase, a process also contributing to the observed line emission from ionized gas, and to the hot gas temperature being lower than expected; alternatively, the latter could be due to the efficiency of the Type Ia supernova heating that is lower than usually adopted.

79 ASTRONOMY AND ASTROPHYSICS↗

Time dependent Schroedinger equation on arbitrary structured grids: Application to photoionization

A systematic technique for conservatively discretizing the time dependent Schroedinger equation on an arbitrary structured grid is given. Spatial differencing is carried out by finite volumes, and temporal differencing is carried out semi-implicitly. It is shown that the resulting algorithm conserves probability to within a round-off error regardless of the grid geometry. The algorithm is efficient for both serial and parallel computation. The conservative nature of the algorithm, and its phase accuracy, are demonstrated for a bound state, and for a free state in an electromagnetic field. The ionization rate for a hydrogen atom in a strong electromagnetic field is computed, and compared with the rate from tunneling theory. The regime of validity of tunneling theory is clarified.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low energy, high power hydrogen neutral beam for plasma heating

A high power, relatively low energy neutral beam injector was developed to upgrade of the neutral beam system of the gas dynamic trap device and C2-U experiment. The ion source of the injector produces a proton beam with the particle energy of 15 keV, current of up to 175 A, and pulse duration of a few milliseconds. The plasma emitter of the ion source is produced by superimposing highly ionized plasma jets from an array of four arc-discharge plasma generators. A multipole magnetic field produced with permanent magnets at the periphery of the plasma box is used to increase the efficiency and improve the uniformity of the plasma emitter. Multi-slit grids with 48% transparency are fabricated from bronze plates, which are spherically shaped to provide geometrical beam focusing. The focal length of the Ion Optical System (IOS) is 3.5 m and the initial beam diameter is 34 cm. The IOS geometry and grid potentials were optimized numerically to ensure accurate beam formation. The measured angular divergences of the beam are ±0.01 rad parallel to the slits and ±0.03 rad in the transverse direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A UNIVERSAL LUMINOSITY FUNCTION FOR RADIO SUPERNOVA REMNANTS

We compile radio supernova remnant (SNR) samples from the literature for 19 nearby galaxies ranging from the SMC to Arp 220, and use this data to constrain the SNR luminosity function (LF) at 20 cm. We find that radio SNR populations are strikingly similar across galaxies. The LF can be described as a power law with constant index and scaling proportional to a galaxy's star formation rate (SFR). Unlike previous authors, we do not find any dependence of SNR luminosity on a galaxy's global interstellar medium density. The observed correlation between the luminosity of a galaxy's brightest SNR and a galaxy's SFR can be completely explained by statistical effects, wherein galaxies with higher SFR more thoroughly sample the high-luminosity end of the SNR LF. The LF is well fitted by a model of SNR synchrotron emission which includes diffusive shock acceleration and magnetic field amplification, if we assume that all remnants are undergoing adiabatic expansion, the densities of star-forming regions are similar across galaxies, and the efficiency of cosmic ray production is constant.

79 ASTRONOMY AND ASTROPHYSICS↗