Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Low-disturbance wind tunnels

During the past years, there was an extensive program under way at the Langley Research Center to upgrade the flow quality in several of the large wind tunnels. This effort has resulted in significant improvements in flow quality in these tunnels and has also increased the understanding of how and where changes in existing and new wind tunnels are most likely to yield the desired improvements. As part of this ongoing program, flow disturbance levels and spectra were measured in several Langley tunnels before and after modifications were made to reduce acoustic and vorticity fluctuations. A brief description of these disturbance control features is given for the Low-Turbulence Pressure Tunnel, the 4 x 7 Meter Tunnel, and the 8 Foot Transonic Pressure Tunnel. To illustrate typical reductions in disturbance levels obtained in these tunnels, data from hot-wire or acoustic sensors are presented. A concept for a subsonic quiet tunnel designed to study boundary layer stability and transition is also presented. Techniques developed at Langley in recent years to eliminate the high intensity and high-frequency acoustic disturbances present in all previous supersonic wind tunnels are described. In conclusion, the low-disturbance levels present in atmospheric flight can now be simulated in wind tunnels over the speed range from low subsonic through high supersonic.

Beckwith, I. E.↗

QA/QC-ed Groundwater Level Time Series in PLM-1 and PLM-6 Monitoring Wells, East River, Colorado (2016-2022)

This data set contains QA/QC-ed (Quality Assurance and Quality Control) water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location at the East River Watershed, Colorado, USA. These wells are used to monitor subsurface water and carbon inventories and fluxes, and to determine the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry (see related references) can be used to estimate rates of solute export from the hillslope to the floodplain and river. QA/QC analysis of measured groundwater levels in monitoring wells PLM-1 and PLM-6 included identification and flagging of duplicated values of timestamps, gap filling of missing timestamps and water levels, removal of abnormal/bad and outliers of measured water levels. The QA/QC analysis also tested the application of different QA/QC methods and the development of regular (5-minute, 1-hour, and 1-day) time series datasets, which can serve as a benchmark for testing other QA/QC techniques, and will be applicable for ecohydrological modeling. The package includes a Readme file, one R code file used to perform QA/QC, a series of 8 data csv files (six QA/QC-ed regular time series datasets of varying intervals (5-min, 1-hr, 1-day) and two files with QA/QC flagging of original data), and three files for the reporting format adoption of this dataset (InstallationMethods, file level metadata (flmd), and data dictionary (dd) files).QA/QC-ed data herein were derived from the original/raw data publication available at Williams et al., 2020 (DOI: 10.15485/1818367). For more information about running R code file (10.15485_1866836_QAQC_PLM1_PLM6.R) to reproduce QA/QC output files, see README (QAQC_PLM_readme.docx). This dataset replaces the previously published raw data time series, and is the final groundwater data product for the PLM wells in the East River. Complete metadata information on the PLM1 and PLM6 wells are available in a related dataset on ESS-DIVE: Varadharajan C, et al (2022). https://doi.org/10.15485/1660962. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales. 2022/09/09 Update: Converted data files using ESS-DIVE’s Hydrological Monitoring Reporting Format. With the adoption of this reporting format, the addition of three new files (v1_20220909_flmd.csv, V1_20220909_dd.csv, and InstallationMethods.csv) were added. The file-level metadata file (v1_20220909_flmd.csv) contains information specific to the files contained within the dataset. The data dictionary file (v1_20220909_dd.csv) contains definitions of column headers and other terms across the dataset. The installation methods file (InstallationMethods.csv) contains a description of methods associated with installation and deployment at PLM1 and PLM6 wells. Additionally, eight data files were re-formatted to follow the reporting format guidance (er_plm1_waterlevel_2016-2020.csv, er_plm1_waterlevel_1-hour_2016-2020.csv, er_plm1_waterlevel_daily_2016-2020.csv, QA_PLM1_Flagging.csv, er_plm6_waterlevel_2016-2020.csv, er_plm6_waterlevel_1-hour_2016-2020.csv, er_plm6_waterlevel_daily_2016-2020.csv, QA_PLM6_Flagging.csv). The major changes to the data files include the addition of header_rows above the data containing metadata about the particular well, units, and sensor description. 2023/01/18 Update: Dataset updated to include additional QA/QC-ed water level data up until 2022-10-12 for ER-PLM1 and 2022-10-13 for ER-PLM6. Reporting format specific files (v2_20230118_flmd.csv, v2_20230118_dd.csv, v2_20230118_InstallationMethods.csv) were updated to reflect the additional data. R code file (QAQC_PLM1_PLM6.R) was added to replace the previously uploaded HTML files to enable execution of the associated code. R code file (QAQC_PLM1_PLM6.R) and ReadMe file (QAQC_PLM_readme.docx) were revised to clarify where original data was retrieved from and to remove local file paths.

54 ENVIRONMENTAL SCIENCES↗

Development and Flight Testing of an Adaptive Vehicle Health-Monitoring Architecture

On going development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle, and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. The expert system is parameterized, which makes it adaptable to be trained to both a user's subject reasoning and existing quantitative analytic tools. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation and, data acquisition, storage and retrieval.

Woodard, Stanley E.↗

Development and Flight Testing of an Autonomous Landing Gear Health-Monitoring System

Development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation; and, data acquisition, storage and retrieval.

Woodard, Stanley E.↗

CMOS Active Pixel Sensors for Low Power, Highly Miniaturized Imaging Systems

The complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology has been developed over the past three years by NASA at the Jet Propulsion Laboratory, and has reached a level of performance comparable to CCDs with greatly increased functionality but at a very reduced power level.

CMOS complementary metal-oxide-semiconductor activ↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a formaldehyde biosensor with application to synthetic methylotrophy

Formaldehyde is a prevalent environmental toxin and a key intermediate in single carbon metabolism. The ability to monitor formaldehyde concentration is, therefore, of interest for both environmental monitoring and for metabolic engineering of native and synthetic methylotrophs, but current methods suffer from low sensitivity, complex workflows, or require expensive analytical equipment. Here we develop a formaldehyde biosensor based on the FrmR repressor protein and cognate promoter of Escherichia coli . Optimization of the native repressor binding site and regulatory architecture enabled detection at levels as low as 1 µM. We then used the sensor to benchmark the in vivo activity of several NAD‐dependent methanol dehydrogenase (Mdh) variants, the rate‐limiting enzyme that catalyzes the first step of methanol assimilation. In order to use this biosensor to distinguish individuals in a mixed population of Mdh variants, we developed a strategy to prevent cross‐talk by using glutathione as a formaldehyde sink to minimize intercellular formaldehyde diffusion. Finally, we applied this biosensor to balance expression of mdh and the formaldehyde assimilation enzymes hps and phi in an engineered E. coli strain to minimize formaldehyde build‐up while also reducing the burden of heterologous expression. This biosensor offers a quick and simple method for sensitively detecting formaldehyde, and has the potential to be used as the basis for directed evolution of Mdh and dynamic formaldehyde control strategies for establishing synthetic methylotrophy.

Woolston, Benjamin M.↗

Convergent use of phosphatidic acid for hepatitis C virus and SARS-CoV-2 replication organelle formation

Double membrane vesicles (DMVs) serve as replication organelles of plus-strand RNA viruses such as hepatitis C virus (HCV) and SARS-CoV-2. Viral DMVs are morphologically analogous to DMVs formed during autophagy, but lipids driving their biogenesis are largely unknown. Here we show that production of the lipid phosphatidic acid (PA) by acylglycerolphosphate acyltransferase (AGPAT) 1 and 2 in the ER is important for DMV biogenesis in viral replication and autophagy. Using DMVs in HCV-replicating cells as model, we found that AGPATs are recruited to and critically contribute to HCV and SARS-CoV-2 replication and proper DMV formation. An intracellular PA sensor accumulated at viral DMV formation sites, consistent with elevated levels of PA in fractions of purified DMVs analyzed by lipidomics. Apart from AGPATs, PA is generated by alternative pathways and their pharmacological inhibition also impaired HCV and SARS-CoV-2 replication as well as formation of autophagosome-like DMVs. These data identify PA as host cell lipid involved in proper replication organelle formation by HCV and SARS-CoV-2, two phylogenetically disparate viruses causing very different diseases, i.e. chronic liver disease and COVID-19, respectively. Host-targeting therapy aiming at PA synthesis pathways might be suitable to attenuate replication of these viruses.

60 APPLIED LIFE SCIENCES↗

Enabling FAIR data in Earth and environmental science with community-centric (meta)data reporting formats

Abstract Research can be more transparent and collaborative by using Findable, Accessible, Interoperable, and Reusable (FAIR) principles to publish Earth and environmental science data. Reporting formats—instructions, templates, and tools for consistently formatting data within a discipline—can help make data more accessible and reusable. However, the immense diversity of data types across Earth science disciplines makes development and adoption challenging. Here, we describe 11 community reporting formats for a diverse set of Earth science (meta)data including cross-domain metadata (dataset metadata, location metadata, sample metadata), file-formatting guidelines (file-level metadata, CSV files, terrestrial model data archiving), and domain-specific reporting formats for some biological, geochemical, and hydrological data (amplicon abundance tables, leaf-level gas exchange, soil respiration, water and sediment chemistry, sensor-based hydrologic measurements). More broadly, we provide guidelines that communities can use to create new (meta)data formats that integrate with their scientific workflows. Such reporting formats have the potential to accelerate scientific discovery and predictions by making it easier for data contributors to provide (meta)data that are more interoperable and reusable.

54 ENVIRONMENTAL SCIENCES↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

The applicability of frame imaging from a spinning spacecraft. Volume 1: Summary report

A detailed study was made of frame-type imaging systems for use on board a spin stabilized spacecraft for outer planets applications. All types of frame imagers capable of performing this mission were considered, regardless of the current state of the art. Detailed sensor models of these systems were developed at the component level and used in the subsequent analyses. An overall assessment was then made of the various systems based upon results of a worst-case performance analysis, foreseeable technology problems, and the relative reliability and radiation tolerance of the systems. Special attention was directed at restraints imposed by image motion and the limited data transmission and storage capability of the spacecraft. Based upon this overall assessment, the most promising systems were selected and then examined in detail for a specified Jupiter orbiter mission. The relative merits of each selected system were then analyzed, and the system design characteristics were demonstrated using preliminary configurations, block diagrams, and tables of estimated weights, volumes and power consumption.

Botticelli, R. A.↗

Evaluation of radiation interference in the Voyager Sun Sensor's cadmium sulfide detector

The simulation of radiation interference effects and the results of a radiation interference test on two Voyager Sun Sensor prototype detector assemblies are reported. The derivation of test levels and requirements are discussed and show that cobalt 60 gamma radiation is an effective and practical simulator of the ionization dose rate effects induced by high-energy electron flux incident on the spacecraft at a rate of 3.7 x 10 to the 8th e/sq cm-sec (10 rad(Si)/s) during closest approach to Jupiter. The test results provide information that is used to confirm an analytic correlation, and to predict satisfactory performance of a spacecraft sun sensing device having stringent angular resolution requirements. The measured detector response shows that at dose rates incident on the detector elements of 2 rad(Si)/sec, which is four times that expected during Jupiter encounter, the radiation-induced angle error is almost an order of magnitude less than that allowed by the acceptance criteria.

Clarke, T. C.↗

Optimally robust redundancy relations for failure detection in uncertain systems

All failure detection methods are based, either explicitly or implicitly, on the use of redundancy, i.e. on (possibly dynamic) relations among the measured variables. The robustness of the failure detection process consequently depends to a great degree on the reliability of the redundancy relations, which in turn is affected by the inevitable presence of model uncertainties. In this paper the problem of determining redundancy relations that are optimally robust is addressed in a sense that includes several major issues of importance in practical failure detection and that provides a significant amount of intuition concerning the geometry of robust failure detection. A procedure is given involving the construction of a single matrix and its singular value decomposition for the determination of a complete sequence of redundancy relations, ordered in terms of their level of robustness. This procedure also provides the basis for comparing levels of robustness in redundancy provided by different sets of sensors.

Lou, X.-C.↗

Parameter estimation in a structural acoustic system with fully nonlinear coupling conditions

A methodology for estimating physical parameters in a class of structural acoustic systems is presented. The general model under consideration consists of an interior cavity which is separated from an exterior noise source by an enclosing elastic structure. Piezoceramic patches are bonded to or embedded in the structure; these can be used both as actuators and sensors in applications ranging from the control of interior noise levels to the determination of structural flaws through nondestructive evaluation techniques. The presence and excitation of patches, however, changes the geometry and material properties of the structure as well as involves unknown patch parameters, thus necessitating the development of parameter estimation techniques which are applicable in this coupled setting. In developing a framework for approximation, parameter estimation and implementation, strong consideration is given to the fact that the input operator is unbonded due to the discrete nature of the patches. Moreover, the model is weakly nonlinear. As a result of the coupling mechanism between the structural vibrations and the interior acoustic dynamics. Within this context, an illustrating model is given, well-posedness and approximations results are discussed and an applicable parameter estimation methodology is presented. The scheme is then illustrated through several numerical examples with simulations modeling a variety of commonly used structural acoustic techniques for systems excitations and data collection.

Banks, H. T.↗

High-precision buffer circuit for suppression of regenerative oscillation

Precision analog signal conditioning electronics have been developed for wind tunnel model attitude inertial sensors. This application requires low-noise, stable, microvolt-level DC performance and a high-precision buffered output. Capacitive loading of the operational amplifier output stages due to the wind tunnel analog signal distribution facilities caused regenerative oscillation and consequent rectification bias errors. Oscillation suppression techniques commonly used in audio applications were inadequate to maintain the performance requirements for the measurement of attitude for wind tunnel models. Feedback control theory is applied to develop a suppression technique based on a known compensation (snubber) circuit, which provides superior oscillation suppression with high output isolation and preserves the low-noise low-offset performance of the signal conditioning electronics. A practical design technique is developed to select the parameters for the compensation circuit to suppress regenerative oscillation occurring when typical shielded cable loads are driven.

Tripp, John S.↗