Automated correction of phase errors in the Advanced Photon Source linac.

Maintaining stable phasing in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this method is not useful for correcting energy spread in a system with many possible phase errors. While energy spread can be corrected by looking at beam size at a dispersive location, this typically involves a beam-intercepting diagnostic and is not compatible with top-up operation. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source (APS) particle accumulator ring or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors, as well as their use in feedback to automatically correct linac phase errors during top-up operation.

43 PARTICLE ACCELERATORS↗

SU-E-T-390: Characterization of the PTW Synthetic Diamond Detector for Radiation Therapy Measurements

Purpose: To investigate the dosimetric properties of new commercially available synthetic single crystal diamond detector under irradiation with therapeutic photon beams from linear accelerators. Methods: A single crystal diamond detector was tested using 6MV photon beam. The detector performance was evaluated for reproducibility, linearity with dose, dose rate dependence, angular dependence, collection efficiency, and measurement of output factors. Lateral field profiles, and percentage depth dose profiles were measured and compared against commercially available detectors. Results: Reproducibility of the detector measurement has a standard deviation of 0.1%. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.03% in the dose range from 0.1 to 5Gy. In addition, the detector response is dose rate independent, with deviations below 0.1% in the investigated dose rate range from 1 to 10Gy per min. Charge collection efficiency deviations were within 0.07% from 1 to 10Gy. No angular dependence along the radial direction while up to 1.3% angular dependence was observed in the axial direction. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical photon beam dosimetry. The agreement with reference dosimeters show that the detector is suitable for measurements for large fields as well as small fields as the ones used for stereotactic radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-379: Dosimetric Impacts of Topical Agents and Dressings On Skin in Radiotherapy

Purpose: This study investigated the superficial dose enhancement in the application of topical agents, clinical materials (thermal mask and bolus) and dressings in megavoltage photon beam radiotherapy. Different topical skin agents, clinical materials and dressings were evaluated and compared for their skin dosimetric impacts on the patients during radiation treatment. Methods: Superficial dose enhancements, or percentage doses with and without the studying materials, were measured using the 6 MV (Field size = 10×10 cm{sup 2}) photon beams produced by a Varian TrueBeam linear accelerator. Twelve topical agents, five dressings (dry and wet conditions) and three clinical materials were studied. A solid water phantom was used with a MOSFET dose detector (TN-1002RD, Thomson and Nielsen Electronic, Ottawa, Ontario, Canada) located under a 1-mm PMMA slab to measure the skin dose. The distance between the radiation source and phantom surface was set to 100 cm in all measurements. The topical agents were distributed evenly with 1.5 mm thickness using our specific sample holder on the phantom surface. Extrapolations were made of 0.5 mm thickness for the agents to provide meaningful clinical value. Results: By comparing surface doses without studying materials, it is found that no topical agents had superficial dose enhancement higher than the clinical materials namely, thermoplastic mask (128%), 5-mm Superflab™ bolus (158%) and 10-mm Superflab™ bolus (171%) regarding the same thickness. Superficial dose enhancement of dry dressing did not exceed 110.5%, while wet dressings produced higher dose enhancements (133% for wet Mepilex lite and 141% for wet Mepilex Ag transfer). Conclusion: It is concluded that the evaluated topical agents and dry dressings did not increase the superficial dose to a concerning level, even using excessive thickness in every fraction of radiation treatment. Wet dressings were found producing the bolus effect, but was still substantially less than applying a thin 5-mm bolus.

43 PARTICLE ACCELERATORS↗

Basis to demonstrate compliance with the National Emission Standards for Hazardous Air Pollutants for the Stand-off Experiments Range

The purpose of this report is to provide the basis and the documentation to demonstrate general compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPS) 40 CFR 61 Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities,” (the Standard) for outdoor linear accelerator operations at the Idaho National Laboratory (INL) Stand-off Experiments Range (SOX). The intent of this report is to inform and gain acceptance of this methodology from the governmental bodies regulating the INL.

43 PARTICLE ACCELERATORS↗

A Search for Neutrinoless Tau Decays to Three Leptons

Using approximately 350 million τ + τ - pair events recorded with the BaBar detector at the Stanford Linear Accelerator Center between 1999 and 2006, a search has been made for neutrinoless, lepton-flavor violating tau decays to three lighter leptons. All six decay modes consistent with conservation of electric charge and energy have been considered. With signal selection efficiencies of 5-12%, we obtain 90% confidence level upper limits on the branching fraction β}(τ → ℓℓℓ) in the range (4-8) x 10 -8 .

43 PARTICLE ACCELERATORS↗

Scientific Challenges for Understanding the Quantum Universe

A workshop titled "Scientific Challenges for Understanding the Quantum Universe" was held December 9-11, 2008, at the Kavli Institute for Particle Astrophysics and Cosmology at the Stanford Linear Accelerator Center-National Accelerator Laboratory. The primary purpose of the meeting was to examine how computing at the extreme scale can contribute to meeting forefront scientific challenges in particle physics, particle astrophysics and cosmology. The workshop was organized around five research areas with associated panels. Three of these, "High Energy Theoretical Physics," "Accelerator Simulation," and "Experimental Particle Physics," addressed research of the Office of High Energy Physics’ Energy and Intensity Frontiers, while the"Cosmology and Astrophysics Simulation" and "Astrophysics Data Handling, Archiving, and Mining" panels were associated with the Cosmic Frontier.

43 PARTICLE ACCELERATORS↗

LANSCE Drift Tube Linac Water Control System Refurbishment

There are several refurbishment projects underway at the Los Alamos National Laboratory LANSCE linear accelerator. Systems involved are: RF, water cooling, networks, diagnostics, timing, controls, etc. The Drift Tube Linac (DTL) portion of the accelerator consists of four DTL tanks, each with three independent water control systems. The systems are about 40 years old, use outdated and non-replaceable equipment and NIM bin control modules, are beyond their design life and provide unstable temperature control. Insufficient instrumentation and documentation further complicate efforts at maintaining system performance. Detailed design of the replacement cooling systems is currently in progress. Previous design experience on the SNS accelerator water cooling systems will be leveraged, see the SNS DTL FDR. Plans call for replacement of water piping, manifolds, pumps, valves, mix tanks, instrumentation (flow, pressure and temperature) and control system hardware and software. This presentation will focus on the control system design with specific attention on planned use of the National Instruments Compact RIO platform with the Experimental Physics and Industrial Control system (EPICS) software toolkit.

Accelerator Design, Technology, and Operations↗

Stripping of H- beams by residual gas in the linac at the Los Alamos neutron science center

The linear accelerator at the Los Alamos Neutron Science Center (LANSCE) accelerates both protons and H{sup -} ions using Cockroft-Walton-type injectors, a drift-tube linac and a coupled-cavity linac. The vacuum is maintained in the range of 10{sup -6} to 10{sup -7} Torr; the residual gas in the vacuum system results in some stripping of the electrons from the H{sup -} ions resulting in beam spill and the potential for unwanted proton beams delivered to experiments. We have measured the amount of fully-stripped H{sup -} beam (protons) that end up at approximately 800 MeV in the beam switchyard at LANSCE using image plates as very sensitive detectors. We present here the motivation for the measurement, the measurement technique and results.

43 PARTICLE ACCELERATORS↗

Search for lepton flavor violating decays tau to l \omega (l = e, mu)

A search for lepton flavor violating decays of a {tau} to a lighter-mass charged lepton and an {omega} vector meson is performed using 384.1 fb{sup -1} of e{sup +}e{sup -} annihilation data collected with the BABAR detector at the Stanford Linear Accelerator Center PEP-II storage ring. No signal is found, and the upper limits on the branching ratios are determined to be {beta}({tau}{sup {+-}} {yields} e{sup {+-}}{omega}) < 1.1 x 10{sup -7} and {beta}({tau}{sup {+-}} {yields} {mu}{sup {+-}}{omega}) < 1.0 x 10{sup -7} at 90% confidence level.

43 PARTICLE ACCELERATORS↗

Branching Fractions and CP-Violating Asymmetries in Radiative B Decays to eta K gamma

The authors present measurements of the CP-violation parameters S and C for the radiative decay B{sup 0} {yields} {eta}K{sub S}{sup 0}{gamma}; for B {yields} {eta}K{gamma} they also measure the branching fractions and for B{sup +} {yields} {eta}K{sup +}{gamma} the time-integrated charge asymmetry {Alpha}{sub ch}. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 465 x 10{sup 6} B{bar B} pairs produced in e{sup +}e{sup -} annihilation. The results are S = -0.18{sub -0.46}{sup +0.49} {+-} 0.12, C = -0.32{sub -0.39}{sup +0.40} {+-} 0.07, {Beta}(B{sup 0} {yields} {eta}K{sup 0}{gamma}) = (7.1{sub -2.0}{sup +2.1} {+-} 0.4) x 10{sup -6}, {Beta}(B{sup +} {yields} {eta}K{sup +}{gamma}) = (7.7 {+-} 1.0 {+-} 0.4) x 10{sup -6}, and {Alpha}{sub ch} = (-9.0{sub -9.8}{sup +10.4} {+-} 1.4) x 10{sup -2}. The first error quoted is statistical and the second systematic.

43 PARTICLE ACCELERATORS↗

CP Violation in Hadronic Penguins at BABAR

The authors present preliminary measurements of time-dependent CP-violation parameters in the decay B{sup 0} {yields} {omega}K{sub S}{sup 0}, B{sup 0} {yields} {eta}{prime}K{sup 0}, B{sup 0} {yields} {pi}{sup 0}K{sub S}{sup 0}, B{sup 0} {yields} {phi}K{sub S}{sup 0}{pi}{sup 0}, and B{sup 0} {yields} K{sup +}K{sup -}K{sub S}{sup 0}, which includes the resonant final states {phi}K{sub S}{sup 0} and f{sub 0}(980)K{sub S}{sup 0}. The data sample corresponds to the full BABAR dataset of 467 x 10{sup 6} B{bar B} pairs produced at the PEP-II asymmetric-energy E{sup +}e{sup -} collider at the Stanford Linear Accelerator Center.

43 PARTICLE ACCELERATORS↗

Monte Carlo Simulations of the Response of Shielded SNM to a Pulsed Neutron Source

Active interrogation (AI) has been used as a technique for the detection and identification of Special Nuclear Material (SNM) for both proposed and field-tested systems. Idaho National Laboratory (INL) has been studying this technique for systems ranging from small systems employing portable electronic neutron generators (ENGs) 1 to larger systems employing linear accelerators as high-energy photon sources for assessment of vehicles and cargo2. In order to assess the feasibility of new systems, INL has undertaken a campaign of Monte Carlo simulations of the response of a variety of masses of SNM in multiple shielding configurations to a pulsed neutron source using the MCNPX3 code, with emphasis on the neutron and photon response of the system as a function of time after the initial neutron pulse. We present here some preliminary results from these calculations. 1. D.L. Chichester and E.H. Seabury, “ Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Nuclear Material,” IEEE Transactions on Nuclear Science 56 (2009) pp 441-447. 2. J.L. Jones et al., “Photonuclear-based, nuclear material detection system for cargo containers,” Nuclear Instruments and Methods in Physics Research B 241 (2005) pp 770-776. 3. D.B. Pelowitz, “MCNPXTM User’s Manual version 2.6.0,” Los Alamos National Laboratory Report LA-CP-07-1473 (2008).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

The NSCL electron beam ion trap for the reacceleration of rare isotopes coming to life: First extraction tests with a high-current electron gun

NSCL is currently constructing the ReA3 reaccelerator, which will accelerate rare isotopes obtained from gas stopping of fast-fragment beams to energies of up to 3 MeV/u for uranium and higher for lighter ions. A high-current charge breeder, based on an electron beam ion trap (EBIT), has been chosen as the first step in the acceleration process, as it has the potential to efficiently produce highly charged ions in a single charge state. These ions are fed into a compact linear accelerator consisting of a radio frequency quadrupole structure and superconducting cavities. The NSCL EBIT has been fully designed with most of the parts constructed. The design concept of the EBIT and results from initial commissioning tests of the electron gun and collector with a temporary 0.4 T magnet are presented.

43 PARTICLE ACCELERATORS↗

Materials for Accelerator Technologies Beyond the Niobium Family

Three niobium-based materials make up the entire present portfolio of superconducting technology for accelerators: Nb-Ti and Nb{sub 3}Sn magnet wires and pure niobium for RF cavities. Because these materials are at a high level of maturity, limits imposed by the boundaries of their superconductivity constrain the energy reach of accelerators to several TeV. We sketch here a plan for targeted development of emerging higher field and higher temperature superconductors that could enable accelerators at significantly higher energies. Niobium-based superconductors are the crucial enablers of present accelerators. The Nb-Ti LHC dipole and quadrupole wires, with transition temperature T{sub c} of 9 K and upper critical field H{sub c2} of 15 T, represent the highest form of superconductor strand art: massive, quarter-ton conductor billets are drawn from 300 mm diameter to {approx}1 mm as a single, multi-kilometer-long piece, while retaining uniformity of the several thousand Nb-Ti filaments to within 5% at the scale of a few micrometers. Strands are twisted into fully transposed cables with virtually no loss, preserving a carefully tuned nanostructure that generates the high flux-pinning forces and high current densities to enable high magnetic fields. Nb{sub 3}Sn, with twice the T{sub c} and H{sub c2}, is now approaching this level of conductor art, where over the last 5 years the LHC Accelerator Research Program (LARP) and the Next European Dipole (NED) program have demonstrated that Nb{sub 3}Sn can be made into 4 meter long quadrupoles with 12 T fields and 250 T/m gradients. Linear accelerators at TJNAF, ORNL (SNS), and under construction for the European XFEL exploit niobium superconducting radio-frequency (SRF) technology, with gradients at {approx}20 MV/m. Tremendous research and development is underway to realize high-power goals for Project X at FNAL and for a possible ILC at 35 MV/m gradients. Despite these impressive achievements, the very maturity of these niobium-based technologies makes them incapable of additional leaps from the several-TeV scale. Nb-Ti is already nearly perfect and operates at the limit of the superconducting phase. Further perfection of Nb cavities and Nb{sub 3}Sn magnets might provide 50 % growth in energy, based on proof-of-principle demonstrations that approach theoretical limits, e.g. 52 MV/m gradient in re-entrant Nb cavities and 18 T dipoles made from Nb3Sn strand. However, operation close to superconducting margins is risky, and cost tradeoffs to execute such a high degrees of perfection are likely to be negative.

43 PARTICLE ACCELERATORS↗

Electron Linacs for High Energy Physics

The purpose of this article is to introduce some of the basic physical principles underlying the operation of electron linear accelerators (electron linacs). Electron linacs have applications ranging from linacs with an energy of a few MeV, such that the electrons are approximately relativistic, to future electron-positron linear colliders having a collision energy in the several-TeV energy range. For the most part, only the main accelerating linac is treated in this article.

43 PARTICLE ACCELERATORS↗

3D treatment planning systems

Three-dimensional (3D) treatment planning systems have evolved and become crucial components of modern radiation therapy. The systems are computer-aided designing or planning softwares that speed up the treatment planning processes to arrive at the best dose plans for the patients undergoing radiation therapy. Furthermore, the systems provide new technology to solve problems that would not have been considered without the use of computers such as conformal radiation therapy (CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). The 3D treatment planning systems vary amongst the vendors and also the dose delivery systems they are designed to support. As such these systems have different planning tools to generate the treatment plans and convert the treatment plans into executable instructions that can be implemented by the dose delivery systems. The rapid advancements in computer technology and accelerators have facilitated constant upgrades and the introduction of different and unique dose delivery systems than the traditional C-arm type medical linear accelerators. The focus of this special issue is to gather relevant 3D treatment planning systems for the radiation oncology community to keep abreast of technology advancement by assess the planning tools available as well as those unique ''tricks or tips'' used to support the different dose delivery systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Electron Clouds in Large Accelerators by Microwave Dispersion

Clouds of low energy electrons in the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation at high currents. Furthermore, it is difficult to probe their density over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave transmitted over a section of the accelerator and used it to measure the average electron cloud density over a 50 m section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center.

43 PARTICLE ACCELERATORS↗