Search NASA⌕ Search

SEARCH · Search NASA

Results for “methods - statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

Purpose: To accurately and efficiently reconstruct a continuous surface from noisy point clouds captured by a surface photogrammetry system (VisionRT). Methods: The authors have developed a level-set based surface reconstruction method on point clouds captured by a surface photogrammetry system (VisionRT). The proposed method reconstructs an implicit and continuous representation of the underlying patient surface by optimizing a regularized fitting energy, offering extra robustness to noise and missing measurements. By contrast to explicit/discrete meshing-type schemes, their continuous representation is particularly advantageous for subsequent surface registration and motion tracking by eliminating the need for maintaining explicit point correspondences as in discrete models. The authors solve the proposed method with an efficient narrowband evolving scheme. The authors evaluated the proposed method on both phantom and human subject data with two sets of complementary experiments. In the first set of experiment, the authors generated a series of surfaces each with different black patches placed on one chest phantom. The resulting VisionRT measurements from the patched area had different degree of noise and missing levels, since VisionRT has difficulties in detecting dark surfaces. The authors applied the proposed method to point clouds acquired under these different configurations, and quantitatively evaluated reconstructed surfaces by comparing against a high-quality reference surface with respect to root mean squared error (RMSE). In the second set of experiment, the authors applied their method to 100 clinical point clouds acquired from one human subject. In the absence of ground-truth, the authors qualitatively validated reconstructed surfaces by comparing the local geometry, specifically mean curvature distributions, against that of the surface extracted from a high-quality CT obtained from the same patient. Results: On phantom point clouds, their method achieved submillimeter reconstruction RMSE under different configurations, demonstrating quantitatively the faith of the proposed method in preserving local structural properties of the underlying surface in the presence of noise and missing measurements, and its robustness toward variations of such characteristics. On point clouds from the human subject, the proposed method successfully reconstructed all patient surfaces, filling regions where raw point coordinate readings were missing. Within two comparable regions of interest in the chest area, similar mean curvature distributions were acquired from both their reconstructed surface and CT surface, with mean and standard deviation of (μ{sub recon} = − 2.7 × 10{sup −3} mm{sup −1}, σ{sub recon} = 7.0 × 10{sup −3} mm{sup −1}) and (μ{sub CT} = − 2.5 × 10{sup −3} mm{sup −1}, σ{sub CT} = 5.3 × 10{sup −3} mm{sup −1}), respectively. The agreement of local geometry properties between the reconstructed surfaces and the CT surface demonstrated the ability of the proposed method in faithfully representing the underlying patient surface. Conclusions: The authors have integrated and developed an accurate level-set based continuous surface reconstruction method on point clouds acquired by a 3D surface photogrammetry system. The proposed method has generated a continuous representation of the underlying phantom and patient surfaces with good robustness against noise and missing measurements. It serves as an important first step for further development of motion tracking methods during radiotherapy.

60 APPLIED LIFE SCIENCES↗

Downwinding for preserving strong stability in explicit integrating factor Runge-Kutta methods

Here strong stability preserving (SSP) Runge-Kutta methods are desirable when evolving in time problems that have discontinuities or sharp gradients and require nonlinear non-inner-product stability properties to be satisfied. Unlike the case for L 2 linear stability, implicit methods do not significantly alleviate the time-step restriction when the SSP property is needed. For this reason, when handling problems with a linear component that is stiff and a nonlinear component that is not, SSP integrating factor Runge-Kutta methods may offer an attractive alternative to traditional time-stepping methods. The strong stability properties of integrating factor Runge-Kutta methods where the transformed problem is evolved with an explicit SSP Runge-Kutta method with non-decreasing abscissas was recently established. However, these methods typically have smaller SSP coefficients (and therefore a smaller allowable time-step) than the optimal SSP Runge-Kutta methods, which often have some decreasing abscissas. In this work, we consider the use of downwinded spatial operators to preserve the strong stability properties of integrating factor Runge-Kutta methods where the Runge-Kutta method has some decreasing abscissas. We present the SSP theory for this approach and present numerical evidence to show that such an approach is feasible and performs as expected. However, we also show that in some cases the integrating factor approach with explicit SSP Runge-Kutta methods with non-decreasing abscissas performs nearly as well, if not better, than with explicit SSP Runge-Kutta methods with downwinding. In conclusion, while the downwinding approach can be rigorously shown to guarantee the SSP property for a larger timestep, in practice using the integrating factor approach by including downwinding as needed with optimal explicit SSP Runge-Kutta methods does not necessarily provide significant benefit over using explicit SSP Runge-Kutta methods with non-decreasing abscissas.

97 MATHEMATICS AND COMPUTING↗

Demonstrating Computational Equivalence Between Continuous and Discrete Adjoint Methods by Calculating Time-Dependent Adjoint Solutions with Neutron Diffusion Models

The continuous adjoint method and the discrete adjoint method are two alternative approaches used to calculate adjoint solutions for adjoint systems. The continuous adjoint method derives adjoint equations analytically from continuous forward equations and then solves the adjoint equations either analytically or numerically in a discretized form whereas the discrete adjoint method calculates the adjoint solutions directly from the discretized forward equations. With regard to the methodology development and calculation procedure, distinct differences are well recognized between the two methods. For certain reasons, both methods are exclusively preferred and commonly used by different computational communities, but limited studies clarify the connections between the two adjoint methods from either of the communities. Herein, this paper demonstrates the computational equivalence between the continuous and discrete adjoint methods by investigating time-dependent adjoint solutions to the two-group neutron diffusion model in nuclear reactor analysis problems using both methods. Adjoint solutions can be used to estimate system parameters for reactor safety analysis. Appropriate final state conditions for the adjoint systems are specified in both of the methods, and the conditions are clarified with proper physical explanations. With the help of an event-based case study on neutron diffusion models, the accuracy of the time-dependent adjoint fluxes obtained from both methods is verified, and the pros and cons of both adjoint methods are examined. More importantly, the computational equivalence of both methods is demonstrated when they are applied to multigroup neutron diffusion systems. The advantage of calculating time-dependent adjoint fluxes by directly solving time-dependent adjoint systems rather than taking steady-state approximations as in common practice is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Partition-of-unity finite-element method for large scale quantum molecular dynamics on massively parallel computational platforms

Over the course of the past two decades, quantum mechanical calculations have emerged as a key component of modern materials research. However, the solution of the required quantum mechanical equations is a formidable task and this has severely limited the range of materials systems which can be investigated by such accurate, quantum mechanical means. The current state of the art for large-scale quantum simulations is the planewave (PW) method, as implemented in now ubiquitous VASP, ABINIT, and QBox codes, among many others. However, since the PW method uses a global Fourier basis, with strictly uniform resolution at all points in space, and in which every basis function overlaps every other at every point, it suffers from substantial inefficiencies in calculations involving atoms with localized states, such as first-row and transition-metal atoms, and requires substantial nonlocal communications in parallel implementations, placing critical limits on scalability. In recent years, real-space methods such as finite-differences (FD) and finite-elements (FE) have been developed to address these deficiencies by reformulating the required quantum mechanical equations in a strictly local representation. However, while addressing both resolution and parallel-communications problems, such local real-space approaches have been plagued by one key disadvantage relative to planewaves: excessive degrees of freedom (grid points, basis functions) needed to achieve the required accuracies. And so, despite critical limitations, the PW method remains the standard today. In this work, we show for the first time that this key remaining disadvantage of real-space methods can in fact be overcome: by building known atomic physics into the solution process using modern partition-of-unity (PU) techniques in finite element analysis. Indeed, our results show order-of-magnitude reductions in basis size relative to state-of-the-art planewave based methods. The method developed here is completely general, applicable to any crystal symmetry and to both metals and insulators alike. We have developed and implemented a full self-consistent Kohn-Sham method, including both total energies and forces for molecular dynamics, and developed a full MPI parallel implementation for large-scale calculations. We have applied the method to the gamut of physical systems, from simple insulating systems with light atoms to complex d- and f-electron systems, requiring large numbers of atomic-orbital enrichments. In every case, the new PU FE method attained the required accuracies with substantially fewer degrees of freedom, typically by an order of magnitude or more, than the current state-of-the-art PW method. Finally, our initial MPI implementation has shown excellent parallel scaling of the most time-critical parts of the code up to 1728 processors, with clear indications of what will be required to achieve comparable scaling for the rest. Having shown that the key remaining disadvantage of real-space methods can in fact be overcome, the work has attracted significant attention: with sixteen invited talks, both domestic and international, so far; two papers published and another in preparation; and three new university and/or national laboratory collaborations, securing external funding to pursue a number of related research directions. Having demonstrated the proof of principle, work now centers on the necessary extensions and optimizations required to bring the prototype method and code delivered here to production applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hierarchical Krylov and nested Krylov methods for extreme-scale computing

The solution of large, sparse linear systems is typically a dominant phase of computation for simulations based on partial differential equations, which are ubiquitous in scientific and engineering applications. While preconditioned Krylov methods are widely used and provide many advantages for solving sparse linear systems that do not have highly convergent, geometric multigrid solvers or specialized fast solvers, Krylov methods encounter well-known scaling difficulties for over 10,000 processor cores because each iteration requires at least one vector inner product, which in turn requires a global synchronization that scales poorly because of internode latency. To aid in overcoming these difficulties, we have developed hierarchical Krylov methods and nested Krylov methods in the PETSc library that reduce the number of global inner products required across the entire system (where they are expensive), though freely allow vector inner products across smaller subsets of the entire system (where they are inexpensive) or use inner iterations that do not invoke vector inner products at all. Nested Krylov methods are a generalization of inner-outer iterative methods with two or more layers. Hierarchical Krylov methods are a generalization of block Jacobi and overlapping additive Schwarz methods, where each block itself is solved by Krylov methods on smaller blocks. Conceptually, the hierarchy can continue recursively to an arbitrary number of levels of smaller and smaller blocks. As a specific case, we introduce the hierarchical FGMRES method, or h-FGMRES, and we demonstrate the impact of two-level h-FGMRES with a variable preconditioner on the PFLOTRAN subsurface flow application. We also demonstrate the impact of nested FGMRES, BiCGStab and Chebyshev methods. These hierarchical Krylov methods and nested Krylov methods significantly reduced overall PFLOTRAN simulation time on the Cray XK6 when using 10,000 through 224,000 cores through the combined effects of reduced global synchronization due to fewer global inner products and stronger inner hierarchical or nested preconditioners.

97 MATHEMATICS AND COMPUTING↗

Iso standardization of theoretical activity evaluation method for low and intermediate level activated waste generated at nuclear power plants

Disposal of low-and intermediate-level activated waste generated at nuclear power plants is being planned or carried out in many countries. The radioactivity concentrations and/or total quantities of long-lived, difficult-to-measure nuclides (DTM nuclides), such as C-14, Ni-63, Nb-94, α emitting nuclides etc., are often restricted by the safety case for a final repository as determined by each country's safety regulations, and these concentrations or amounts are required to be known and declared. With respect to waste contaminated by contact with process water, the Scaling Factor method (SF method), which is empirically based on sampling and analysis data, has been applied as an important method for determining concentrations of DTM nuclides. This method was standardized by the International Organization for Standardization (ISO) and published in 2007 as ISO21238 'Scaling factor method to determine the radioactivity of low and intermediate-level radioactive waste packages generated at nuclear power plants' [1]. However, for activated metal waste with comparatively high concentrations of radioactivity, such as may be found in reactor control rods and internal structures, direct sampling and radiochemical analysis methods to evaluate the DTM nuclides are limited by access to the material and potentially high personnel radiation exposure. In this case, theoretical calculation methods in combination with empirical methods based on remote radiation surveys need to be used to best advantage for determining the disposal inventory of DTM nuclides while minimizing exposure to radiation workers. Pursuant to this objective a standard for the theoretical evaluation of the radioactivity concentration of DTM nuclides in activated waste, is in process through ISO TC85/SC5 (ISO Technical Committee 85: Nuclear energy, nuclear technologies, and radiological protection; Subcommittee 5: Nuclear fuel cycle). The project team for this ISO standard was formed in 2011 and is composed of experts from 11 countries. The project team has been conducting technical discussions on theoretical methods for determining concentrations of radioactivity, and has developed the draft International Standard of ISO16966 'Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors' [2]. This paper describes the international standardization process developed by the ISO project team, and outlines the following two theoretical activity evaluation methods:? Point method? Range method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography

Purpose: An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. Methods: Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. Results: By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. Conclusions: The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity.

60 APPLIED LIFE SCIENCES↗

Investigation of finite-volume methods to capture shocks and turbulence spectra in compressible flows

The aim of the present paper is to provide a comparison between several finite-volume methods of different numerical accuracy: the second-order Godunov method with PPM interpolation and the high-order finite-volume WENO method. In this work, the results show that while on a smooth problem the high-order method performs better than the second-order one, when the solution contains a shock all the methods collapse to first-order accuracy. In the context of the decay of compressible homogeneous isotropic turbulence with shocklets, the actual overall order of accuracy of the methods reduces to second-order, despite the use of fifth-order reconstruction schemes at cell interfaces. Most important, results in terms of turbulent spectra are similar regardless of the numerical methods employed, except that the PPM method fails to provide an accurate representation in the high-frequency range of the spectra. It is found that this specific issue comes from the slope-limiting procedure and a novel hybrid PPM/WENO method is developed that has the ability to capture the turbulent spectra with the accuracy of a high-order method, but at the cost of the second-order Godunov method. Overall, it is shown that virtually the same physical solution can be obtained much faster by refining a simulation with the second-order method and carefully chosen numerical procedures, rather than running a coarse high-order simulation. Our results demonstrate the importance of evaluating the accuracy of a numerical method in terms of its actual spectral dissipation and dispersion properties on mixed smooth/shock cases, rather than by the theoretical formal order of convergence rate.

97 MATHEMATICS AND COMPUTING↗

A hybrid Monte Carlo and response matrix Monte Carlo method in criticality calculation

Full core calculations are very useful and important in reactor physics analysis, especially in computing the full core power distributions, optimizing the refueling strategies and analyzing the depletion of fuels. To reduce the computing time and accelerate the convergence, a method named Response Matrix Monte Carlo (RMMC) method based on analog Monte Carlo simulation was used to calculate the fixed source neutron transport problems in repeated structures. To make more accurate calculations, we put forward the RMMC method based on non-analog Monte Carlo simulation and investigate the way to use RMMC method in criticality calculations. Then a new hybrid RMMC and MC (RMMC+MC) method is put forward to solve the criticality problems with combined repeated and flexible geometries. This new RMMC+MC method, having the advantages of both MC method and RMMC method, can not only increase the efficiency of calculations, also simulate more complex geometries rather than repeated structures. Several 1-D numerical problems are constructed to test the new RMMC and RMMC+MC method. The results show that RMMC method and RMMC+MC method can efficiently reduce the computing time and variations in the calculations. Finally, the future research directions are mentioned and discussed at the end of this paper to make RMMC method and RMMC+MC method more powerful. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo Direct Simulation Method for Initiation Probability Problems

During the early period of a supercritical system, the growth of fission chains shows a significant stochastic feature. In multiplying medium, it is a probability issue of fail-pass type for a single neutron to sponsor a divergent fission chain, and the probability of success is named as single neutron initiation probability. Meanwhile, in the presence of a weak neutron source, the time at which fission burst occurs also exhibits a stochastic nature, which can be observed on experiments of pulsed reactors such as GODIVA I and GODIVA II. The initiation probability and burst waiting time reflect the dynamic feature of a supercritical system, which are very important for nuclear criticality safety concerns. It is desirable that a supercritical system has an initiation probability very close to zero and releases limited energy in case of criticality accidents. The stochastic process of neutron population evolution in early age in a multiplying system is governed by Bell's equation in the form of an adjoint neutron transport equation with a non-linear fission term. In order to solve this stochastic neutron transport equation, the deterministic method discretizing the phase space was proposed long ago and has been implemented in several SN codes such as Partisn, Ardra and PANDA. However, the deterministic method is of limited usage, due to its poor ability to precisely describe real-world 3D complex geometries and continuous energy neutron spectrum. Recently, Monte Carlo methods have gradually gained attention for solving Bell's equation. Greenman from LLNL proposed an analog Monte Carlo forward-transport method for calculating initiation probability in 2007. He implemented this method by introducing the maximum age parameter, the time sub-interval and the neutron progenitor tag into Mercury in time-dependent fixed-source simulation mode. This method is only suitable for initiation probability calculations, however not for analyzing the randomness of burst waiting time. Later, GANG in 2011 developed the GSMP (Generalized Semi-Markov Process method) Monte Carlo method according to Bell's equation. While the GSMP method, which can deal with both initiation probability and burst waiting time, is flexible and powerful for zero-dimensional problems, it is not favorable when extended to 3D and continuous energy problems due to severe lack of computational efficiency. In 2015, a direct Monte Carlo simulation method for stochastic systems problems was implemented in MCATK, yet this method has not been applied specifically to the burst waiting time. In this work, a new and efficient 3D Monte Carlo direct simulation method for calculating both the initiation probability and the burst waiting time is developed. By taking random factors during evolvement of fission chains into account in dynamic Monte Carlo simulation, this new method has the potential of simulating the whole process from source neutron injection to exponential growth of the neutron population, and finally to extinction of the neutron pulse. This capability is useful in criticality accidents evaluation and pulsed reactor experiments explanation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intervertebral anticollision constraints improve out-of-plane translation accuracy of a single-plane fluoroscopy-to-CT registration method for measuring spinal motion

Purpose: The study aimed to propose a new single-plane fluoroscopy-to-CT registration method integrated with intervertebral anticollision constraints for measuring three-dimensional (3D) intervertebral kinematics of the spine; and to evaluate the performance of the method without anticollision and with three variations of the anticollision constraints via an in vitro experiment. Methods: The proposed fluoroscopy-to-CT registration approach, called the weighted edge-matching with anticollision (WEMAC) method, was based on the integration of geometrical anticollision constraints for adjacent vertebrae and the weighted edge-matching score (WEMS) method that matched the digitally reconstructed radiographs of the CT models of the vertebrae and the measured single-plane fluoroscopy images. Three variations of the anticollision constraints, namely, T-DOF, R-DOF, and A-DOF methods, were proposed. An in vitro experiment using four porcine cervical spines in different postures was performed to evaluate the performance of the WEMS and the WEMAC methods. Results: The WEMS method gave high precision and small bias in all components for both vertebral pose and intervertebral pose measurements, except for relatively large errors for the out-of-plane translation component. The WEMAC method successfully reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five degrees of freedom (DOF) more or less unaltered. The means (standard deviations) of the out-of-plane translational errors were less than -0.5 (0.6) and -0.3 (0.8) mm for the T-DOF method and the R-DOF method, respectively. Conclusions: The proposed single-plane fluoroscopy-to-CT registration method reduced the out-of-plane translation errors for intervertebral kinematic measurements while keeping the measurement accuracies for the other five DOF more or less unaltered. With the submillimeter and subdegree accuracy, the WEMAC method was considered accurate for measuring 3D intervertebral kinematics during various functional activities for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

Quantifying the accuracy of the tumor motion and area as a function of acceleration factor for the simulation of the dynamic keyhole magnetic resonance imaging method

Purpose: The dynamic keyhole is a new MR image reconstruction method for thoracic and abdominal MR imaging. To date, this method has not been investigated with cancer patient magnetic resonance imaging (MRI) data. The goal of this study was to assess the dynamic keyhole method for the task of lung tumor localization using cine-MR images reconstructed in the presence of respiratory motion. Methods: The dynamic keyhole method utilizes a previously acquired a library of peripheral k-space datasets at similar displacement and phase (where phase is simply used to determine whether the breathing is inhale to exhale or exhale to inhale) respiratory bins in conjunction with central k-space datasets (keyhole) acquired. External respiratory signals drive the process of sorting, matching, and combining the two k-space streams for each respiratory bin, thereby achieving faster image acquisition without substantial motion artifacts. This study was the first that investigates the impact of k-space undersampling on lung tumor motion and area assessment across clinically available techniques (zero-filling and conventional keyhole). In this study, the dynamic keyhole, conventional keyhole and zero-filling methods were compared to full k-space dataset acquisition by quantifying (1) the keyhole size required for central k-space datasets for constant image quality across sixty four cine-MRI datasets from nine lung cancer patients, (2) the intensity difference between the original and reconstructed images in a constant keyhole size, and (3) the accuracy of tumor motion and area directly measured by tumor autocontouring. Results: For constant image quality, the dynamic keyhole method, conventional keyhole, and zero-filling methods required 22%, 34%, and 49% of the keyhole size (P < 0.0001), respectively, compared to the full k-space image acquisition method. Compared to the conventional keyhole and zero-filling reconstructed images with the keyhole size utilized in the dynamic keyhole method, an average intensity difference of the dynamic keyhole reconstructed images (P < 0.0001) was minimal, and resulted in the accuracy of tumor motion within 99.6% (P < 0.0001) and the accuracy of tumor area within 98.0% (P < 0.0001) for lung tumor monitoring applications. Conclusions: This study demonstrates that the dynamic keyhole method is a promising technique for clinical applications such as image-guided radiation therapy requiring the MR monitoring of thoracic tumors. Based on the results from this study, the dynamic keyhole method could increase the imaging frequency by up to a factor of five compared with full k-space methods for real-time lung tumor MRI.

60 APPLIED LIFE SCIENCES↗

Immersed Boundary Methods for High-Resolution Simulation of Atmospheric Boundary-Layer Flow Over Complex Terrain

Mesoscale models, such as the Weather Research and Forecasting (WRF) model, are increasingly used for high resolution simulations, particularly in complex terrain, but errors associated with terrain-following coordinates degrade the accuracy of the solution. Use of an alternative Cartesian gridding technique, known as an immersed boundary method (IBM), alleviates coordinate transformation errors and eliminates restrictions on terrain slope which currently limit mesoscale models to slowly varying terrain. In this dissertation, an immersed boundary method is developed for use in numerical weather prediction. Use of the method facilitates explicit resolution of complex terrain, even urban terrain, in the WRF mesoscale model. First, the errors that arise in the WRF model when complex terrain is present are presented. This is accomplished using a scalar advection test case, and comparing the numerical solution to the analytical solution. Results are presented for different orders of advection schemes, grid resolutions and aspect ratios, as well as various degrees of terrain slope. For comparison, results from the same simulation are presented using the IBM. Both two-dimensional and three-dimensional immersed boundary methods are then described, along with details that are specific to the implementation of IBM in the WRF code. Our IBM is capable of imposing both Dirichlet and Neumann boundary conditions. Additionally, a method for coupling atmospheric physics parameterizations at the immersed boundary is presented, making IB methods much more functional in the context of numerical weather prediction models. The two-dimensional IB method is verified through comparisons of solutions for gentle terrain slopes when using IBM and terrain-following grids. The canonical case of flow over a Witch of Agnesi hill provides validation of the basic no-slip and zero gradient boundary conditions. Specified diurnal heating in a valley, producing anabatic winds, is used to validate the use of flux (non-zero) boundary conditions. This anabatic flow set-up is further coupled to atmospheric physics parameterizations, which calculate surface fluxes, demonstrating that the IBM can be coupled to various land-surface parameterizations in atmospheric models. Additionally, the IB method is extended to three dimensions, using both trilinear and inverse distance weighted interpolations. Results are presented for geostrophic flow over a three-dimensional hill. It is found that while the IB method using trilinear interpolation works well for simple three-dimensional geometries, a more flexible and robust method is needed for extremely complex geometries, as found in three-dimensional urban environments. A second, more flexible, immersed boundary method is devised using inverse distance weighting, and results are compared to the first IBM approach. Additionally, the functionality to nest a domain with resolved complex geometry inside of a parent domain without resolved complex geometry is described. The new IBM approach is used to model urban terrain from Oklahoma City in a one-way nested configuration, where lateral boundary conditions are provided by the parent domain. Finally, the IB method is extended to include wall model parameterizations for rough surfaces. Two possible implementations are presented, one which uses the log law to reconstruct velocities exterior to the solid domain, and one which reconstructs shear stress at the immersed boundary, rather than velocity. These methods are tested on the three-dimensional canonical case of neutral atmospheric boundary layer flow over flat terrain.

17 WIND ENERGY↗

Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.

Pavlish, John↗

Method for Implementing Subsurface Solid Derived Concentration Guideline Levels (DCGL) - 12331

The U.S. Nuclear Regulatory Commission (NRC) and other federal agencies currently approve the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) as guidance for licensees who are conducting final radiological status surveys in support of decommissioning. MARSSIM provides a method to demonstrate compliance with the applicable regulation by comparing residual radioactivity in surface soils with derived concentration guideline levels (DCGLs), but specifically discounts its applicability to subsurface soils. Many sites and facilities undergoing decommissioning contain subsurface soils that are potentially impacted by radiological constituents. In the absence of specific guidance designed to address the derivation of subsurface soil DCGLs and compliance demonstration, decommissioning facilities have attempted to apply DCGLs and final status survey techniques designed specifically for surface soils to subsurface soils. The decision to apply surface soil limits and surface soil compliance metrics to subsurface soils typically results in significant over-excavation with associated cost escalation. MACTEC, Inc. has developed the overarching concepts and principles found in recent NRC decommissioning guidance in NUREG 1757 to establish a functional method to derive dose-based subsurface soil DCGLs. The subsurface soil method developed by MACTEC also establishes a rigorous set of criterion-based data evaluation metrics (with analogs to the MARSSIM methodology) that can be used to demonstrate compliance with the developed subsurface soil DCGLs. The method establishes a continuum of volume factors that relate the size and depth of a volume of subsurface soil having elevated concentrations of residual radioactivity with its ability to produce dose. The method integrates the subsurface soil sampling regime with the derivation of the subsurface soil DCGL such that a self-regulating optimization is naturally sought by both the responsible party and regulator. This paper describes the concepts and basis used by MACTEC to develop the dose-based subsurface soil DCGL method. The paper will show how MACTEC's method can be used to demonstrate that higher concentrations of residual radioactivity in subsurface soils (as compared with surface soils) can meet the NRC's dose-based regulations. MACTEC's method has been used successfully to obtain the NRC's radiological release at a site with known radiological impacts to subsurface soils exceeding the surface soil DCGL, saving both time and cost. Having considered the current NRC guidance for consideration of residual radioactivity in subsurface soils during decommissioning, MACTEC has developed a technically based approach to the derivation of and demonstration of compliance with subsurface soil DCGLs for radionuclides. In fact, the process uses the already accepted concepts and metrics approved for surface soils as the foundation for deriving scaling factors used to calculate subsurface soil DCGLs that are at least equally protective of the decommissioning annual dose standard. Each of the elements identified for consideration in the current NRC guidance is addressed in this proposed method. Additionally, there is considerable conservatism built into the assumptions and techniques used to arrive at subsurface soil scaling factors and DCGLs. The degree of conservatism embodied in the approach used is such that risk managers and decision makers approving and using subsurface soil DCGLs derived in accordance with this method can be confident that the future exposures will be well below permissible and safe levels. The technical basis for the method can be applied to a broad variety of sites with residual radioactivity in subsurface soils. Given the costly nature of soil surveys, excavation, and disposal of soils as low-level radioactive waste, MACTEC's method for deriving and demonstrating compliance with subsurface soil DCGLs offers the possibility of significant cost savings over the traditional approach of applying surface soil DCGLs to subsurface soils. Furthermore, while yet untested, MACTEC believes that the concepts and methods embodied in this approach could readily be applied to other types of contamination found in subsurface soils. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectral deferred correction methods for high-order accuracy in poroelastic problems

In this work, we investigate high-order accuracy in time integration by examining two operator splitting methods for poroelastic problems: the two-pass and the spectral deferred correction (SDC) methods. To enhance the order of accuracy, the two-pass method partitions a coupled operator symmetrically, whereas the SDC method corrects truncation errors by establishing an error equation. These high-order methods are applied to underlying solution strategies, i.e., monolithic, fixed-stress sequential, and undrained sequential methods. We observe that semi-discretized systems from spatial discretization have forms similar to those of index-1 differential algebraic equations (DAEs), causing order reduction against the two-pass method when it is used in conjunction with either the monolithic or sequential method. On the other hand, the SDC in conjunction with the monolithic method exhibits the desired second-order accuracy in poroelastic problems while increasing the order of accuracy for index-1 DAEs. However, the SDC in conjunction with either of the two sequential methods does not achieve the desired order of accuracy, and maintains first order because the flow equation for poroelasticity has an additional approximation associated with the volumetric strain rate term, which does not yield exactly the same forms as those of conventional DAEs. Thus, the monolithic SDC method can achieve higher-order accuracy, but may require higher computational costs because it involves solving matrix systems larger than those for the sequential methods.

02 PETROLEUM↗