Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Amplitude and phase-shaping effects in beamwaveguides

Results are presented of an investigation on improvements in a geometrical optics (GO) design of a beam-waveguide antenna for operation at multiple frequency bands. Improvements might be possible by changing the design of the lower-frequency input pattern to the beam waveguide. The effects of amplitude and phase shaping the input pattern have been studied with an aperture diffraction model. Accurate vector near-field computations were made rapidly with a spherical wave expansion of the input and scattered fields. Numerical results indicate that for aperture sizes of less than 30 wavelengths, there is insufficient control on defocusing due to amplitude and phase shaping. Design tradeoffs on spillover loss and defocusing are possible by changing the amplitude and phase distribution of the input wavefront for larger size apertures.

Rengarajan, Sembiam R.↗

Supersonic helium beam diagnostic for fluctuation measurements of electron temperature and density at the Tokamak TEXTOR

A supersonic helium beam diagnostic, based on the line-ratio technique for high resolution electron density and temperature measurements in the plasma edge (r/a > 0.9) was designed, built, and optimised at TEXTOR (Torus Experiment for Technology Oriented Research). The supersonic injection system, based on the Campargue skimmer-nozzle concept, was developed and optimised in order to provide both a high neutral helium beam density of n{sub 0}= 1.5 Multiplication-Sign 10{sup 18} m{sup -3} and a low beam divergence of {+-}1 Degree-Sign simultaneously, achieving a poloidal resolution of {Delta}{sub poloidal}= 9 mm. The setup utilises a newly developed dead volume free piezo valve for operation in a high magnetic field environment of up to 2 T with a maximum repetition rate of 80 Hz. Gas injections are realised for a duration of 120 ms at a repetition rate of 2 Hz (duty cycle 1/3). In combination with a high sensitivity detection system, consisting of three 32 multi-channel photomultipliers (PMTs), measurements of edge electron temperature and density with a radial resolution of {Delta}{sub radial}= 2 mm and a maximum temporal resolution of {Delta}t Asymptotically-Equal-To 2 {mu}s (470 kHz) are possible for the first time. The diagnostic setup at TEXTOR is presented. The newly developed injection system and its theoretical bases are discussed. The applicability of the stationary collisional-radiative model as basis of the line-ratio technique is shown. Finally, an example of a fluctuation analysis demonstrating the unique high temporal and spatial resolution capabilities of this new diagnostic is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Abelian Bremsstrahlung and Azimuthal Asymmetries in High Energy p+A Reactions

Here we apply the GLV reaction operator solution to the Vitev-Gunion-Bertsch (VGB) boundary conditions to compute the all-order in nuclear opacity non-abelian gluon bremsstrahlung of event- by-event uctuating beam jets in nuclear collisions. We evaluate analytically azimuthal Fourier moments of single gluon, v$M\atop{n}$ {1}, and even number 2ℓ gluon, v$M\atop{n}$ {2ℓ} inclusive distributions in high energy p+A reactions as a function of harmonic $n$, target recoil cluster number, $M$, and gluon number, 2ℓ, at RHIC and LHC. Multiple resolved clusters of recoiling target beam jets together with the projectile beam jet form Color Scintillation Antenna (CSA) arrays that lead to character- istic boost non-invariant trapezoidal rapidity distributions in asymmetric B+A nuclear collisions. The scaling of intrinsically azimuthally anisotropic and long range in η nature of the non-Abelian bremsstrahlung leads to v n moments that are similar to results from hydrodynamic models, but due entirely to non-Abelian wave interference phenomena sourced by the fluctuating CSA. Our analytic non-flow solutions are similar to recent numerical saturation model predictions but differ by predicting a simple power-law hierarchy of both even and odd v n without invoking k T factorization. A test of CSA mechanism is the predicted nearly linear η rapidity dependence of the v n (k T η). Non- Abelian beam jet bremsstrahlung may thus provide a simple analytic solution to Beam Energy Scan (BES) puzzle of the near $\sqrt{s}$ independence of v n (pT) moments observed down to 10 AGeV where large-x valence quark beam jets dominate inelastic dynamics. Recoil bremsstrahlung from multiple independent CSA clusters could also provide a partial explanation for the unexpected similarity of v n in p(D) + A and non-central A + A at same dN=dη multiplicity as observed at RHIC and LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A parallel variable population multi-objective optimizer for accelerator beam dynamics optimization

The simultaneous optimization of multiple objective functions is needed in many particle accelerator applications. In this paper, we present a parallel evolution based multi-objective optimizer that uses a variable population from generation to generation and an external storage to save good solutions. Two heuristic optimization methods, one uses the unified differential evolution and the other uses the real-coded genetic algorithm, are included in the optimizer to generate next generation candidate solutions, and are compared in the test examples. Finally, as an application, we applied this optimizer to the beam dynamics design optimization of a photoinjector and attained the optimal front solutions after 200 generations with the unified differential evolution offspring production scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics

LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months’ commissioning, some outstanding results have been achieved, such as 1.97 emA of O{sup 6+}, 1.7 emA of Ar{sup 8+}, 1.07 emA of Ar{sup 9+}, and 118 euA of Bi{sup 28+}. The source has also successfully delivered O{sup 5+} and Ar{sup 8+} ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of primary ion provider for relativistic heavy ion collider electron beam ion source

Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

MM-wave emission by magnetized plasma during sub-relativistic electron beam relaxation

There are described electromagnetic spectra of radiation emitted by magnetized plasma during sub-relativistic electron beam in a double plasma frequency band. Experimental studies were performed at the multiple-mirror trap GOL-3. The electron beam had the following parameters: 70–110 keV for the electron energy, 1–10 MW for the beam power and 30–300 μs for its duration. The spectrum was measured in 75–230 GHz frequency band. The frequency of the emission follows variations in electron plasma density and magnetic field strength. The specific emission power on the length of the plasma column is estimated on the level 0.75 kW/cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of primary ion provider for RHIC-EBIS

Brookhaven National Laboratory (BNL) has developed the new pre-injector system, Electron Beam Ion Source (EBIS) for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

Monte Carlo calculation of the average neutron depolarization for the NPDGamma experiment

The NPDGamma experiment measures the asymmetry in γ-ray emission in the capture of polarized neutrons on liquid parahydrogen. The beam polarization is measured using 3 He spin analysis, but this measurement does not account for the contribution of depolarization from spin–flip scattering primarily due to orthohydrogen in the bulk liquid. This is a systematic effect that dilutes the experimental asymmetry and is modeled using Monte Carlo. Finally, methods for tracking neutron spin in MCNPX were developed in order to calculate the average neutron polarization upon capture for use as a multiplicative correction to the measured beam polarization for the NPDGamma experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localized Dose Enhancement to Tumor Blood Vessel Endothelial Cells via Megavoltage X-rays and Targeted Gold Nanoparticles: New Potential for External Beam Radiotherapy

Purpose: Tumor endothelial cell damage during radiation therapy may contribute significantly to tumor eradication and treatment efficacy. Gold nanoparticles (AuNPs) delivered preferentially to the walls of tumor blood vessels produce low-energy, short-range photoelectrons during external beam radiotherapy, boosting dose to the tumor microvasculature. In this study dosimetry at the single-cell level is used to estimate the anticipated AuNP-mediated dose enhancement to tumor endothelial cells during 6-MV X-ray irradiation. Methods and Materials: Endothelial cells are modeled as thin slabs with 100-nm-diameter AuNPs attached within the blood vessel. The number of photoelectrons emitted per AuNP per gray of X-rays is computed at multiple points along the external beam central axis by use of a Monte Carlo-generated energy fluence spectrum. The energy deposited from AuNP emissions to the endothelium is calculated based on an analytic method incorporating the energy-loss formula of Cole. The endothelial dose enhancement factor (EDEF) is the ratio of the overall (externally plus internally generated) dose to endothelial cells in the presence of AuNPs to the dose without AuNPs (from the external beam only). Results: At 20-cm depth, the EDEF is 1.7 (70% dose increase) for an intravascular AuNP concentration of 30 mg/g. Most of this dose enhancement arises from the low-energy (approximately 100 keV) portion of the linear accelerator X-ray spectrum. Furthermore, for AuNP concentrations ranging from 7 to 140 mg/g, EDEF values of 1.2 to 4.4 (20-340% dose increase) are calculated. Conclusions: In contrast to calculations assuming that AuNPs distributed homogeneously throughout the target volume (macrodosimetry), our cellular microdosimetry calculations predict a major dose enhancement to tumor microvasculature from conventional linear accelerator X-rays. This effect may enable the delivery of ablative therapeutic doses to these sensitive microstructures while maintaining established dose constraints for the organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strain-Layer-Superlattice Light Modulator

Conceptual device combines resonant reflection and photovoltaic action to enable one light beam to impose spatial and temporal modulation on another light beam. Such spatial light modulator, with high speed and multiplicity of parallel signal channels, used in image processing or similar computation requiring high data-throughput rates. Microstructures of GaAs and InAs with multiple quantum wells and compositional superlattices grown by molecular-beam epitaxy. Enhanced electro-optical properties of arrangement of alternating layers enables writing light beam to modulate reading light beam.

Maserjian, Joseph↗

Multiplicity and net-electric charge fluctuations in central Ar+Sc interactions at 13 A , 19 A , 30 A , 40 A , 75 A , and 150 A GeV/c beam momenta measured by NA61/SHINE at the CERN SPS

This paper presents results on multiplicity fluctuations of positively and negatively charged hadrons as well as net-electric charge fluctuations measured in central Ar+Sc interactions at beam momenta 13 A , 19 A , 30 A , 40 A , 75 A , and 150 A GeV/c. The fluctuation analysis is one of the tools to search for the predicted critical point of strongly interacting matter. Results are corrected for the experimental biases and quantified using cumulant ratios. In most instances, multiplicity and net-charge distributions appear narrower than the corresponding Poisson or Skellam distributions. Cumulant ratios are compared with the EPOS1.99 model predictions, which provide a qualitative description that aligns with observations for positively and negatively charged particles. The obtained results are also compared to earlier NA61/SHINE results from inelastic p+p interactions in the same analysis acceptance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements and modeling of Alfven eigenmode induced fast ion transport and loss in DIII-D and ASDEX Upgrade

Neutral beam injection into reversed magnetic shear DIII-D and ASDEX Upgrade plasmas produces a variety of Alfvenic activity including toroidicity-induced Alfven eigenmodes and reversed shear Alfven eigenmodes (RSAEs). These modes are studied during the discharge current ramp phase when incomplete current penetration results in a high central safety factor and increased drive due to multiple higher order resonances. Scans of injected 80 keV neutral beam power on DIII-D showed a transition from classical to AE dominated fast ion transport and, as previously found, discharges with strong AE activity exhibit a deficit in neutron emission relative to classical predictions. By keeping beam power constant and delaying injection during the current ramp, AE activity was reduced or eliminated and a significant improvement in fast ion confinement observed. Similarly, experiments in ASDEX Upgrade using early 60 keV neutral beam injection drove multiple unstable RSAEs. Periods of strong RSAE activity are accompanied by a large (peak {delta}S{sub n}/S{sub n{approx_equal}}60%) neutron deficit. Losses of beam ions modulated at AE frequencies were observed using large bandwidth energy and pitch resolving fast ion loss scintillator detectors and clearly identify their role in the process. Modeling of DIII-D loss measurements using guiding center following codes to track particles in the presence of ideal magnetohydrodynamic (MHD) calculated AE structures (validated by comparison to experiment) is able to reproduce the dominant energy, pitch, and temporal evolution of these losses. While loss of both co and counter current fast ions occurs, simulations show that the dominant loss mechanism observed is the mode induced transition of counter-passing fast ions to lost trapped orbits. Modeling also reproduces a coherent signature of AE induced losses and it was found that these coherent losses scale proportionally with the amplitude; an additional incoherent contribution scales quadratically with the mode amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production of fine structures in type III solar radio bursts due to turbulent density profiles

Magnetic reconnection events in the corona release energetic electron beams along open field lines, and the beams generate radio emission at multiples of the electron plasma frequency f{sub p} to produce type III solar radio bursts. Type III bursts often exhibit irregularities in the form of flux modulations with frequency and/or local temporal advances and delays, and a type IIIb burst represents the extreme case where a type III burst is fragmented into a chain of narrowband features called striae. Remote and in situ spacecraft measurements have shown that density turbulence is ubiquitous in the corona and solar wind, and often exhibits a Kolmogorov power spectrum. In this work, we numerically investigate the effects of one-dimensional macroscopic density turbulence (along the beam direction) on the behavior of type III bursts, and find that this turbulence produces stria-like fine structures in the dynamic spectra of both f{sub p} and 2 f{sub p} radiation. Spectral and temporal fine structures in the predicted type III emission are produced by variations in the scattering path lengths and group speeds of radio emission, and in the locations and sizes of emitting volumes. Moderate turbulence levels yield flux enhancements with much broader half-power bandwidths in f{sub p} than 2 f{sub p} emission, possibly explaining the often observed type IIIb-III harmonic pairs as being where intensifications in 2 f{sub p} radiation are not resolved observationally. Larger turbulence levels producing trough-peak regions in the plasma density profile may lead to broader, resolvable intensifications in 2 f{sub p} radiation, which may account for the type IIIb-IIIb pairs that are sometimes observed.

79 ASTRONOMY AND ASTROPHYSICS↗

A protocol for satellite access via use of spot-beams

In this paper, we develop a new protocol for multiple access to a GEO-satellite that utilizes an electronically-switched spot-beam. The emphasis is on an integrated voice/data protocol which takes advantage of the propagation latency and which offers centralized control with excellent delay and throughput characteristics. The protocol also allows full exploitation of the advantages of a hopping beam satellite, such as smaller earth stations and frequency re-use.

Ramseier, Stefan↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Fabrication of GeSn-multiple quantum wells by overgrowth of Sn on Ge by using molecular beam epitaxy

We report on the fabrication and structural characterization of epitaxially grown ultra-thin layers of Sn on Ge virtual substrates (Si buffer layer overgrown by a 50 nm thick Ge epilayer followed by an annealing step). Samples with 1 to 5 monolayers of Sn on Ge virtual substrates were grown using solid source molecular beam epitaxy and characterized by atomic force microscopy. We determined the critical thickness at which the transition from two-dimensional to three-dimensional growth occurs. This transition is due to the large lattice mismatch between Ge and Sn (≈14.7%). By depositing Ge on top of Sn layers, which have thicknesses at or just below the critical thickness, we were able to fabricate ultra-narrow GeSn multi-quantum-well structures that are fully embedded in Ge. We report results on samples with one and ten GeSn wells separated by 5 and 10 nm thick Ge spacer layers that were characterized by high resolution transmission electron microscopy and X-ray diffraction. We discuss the structure and material intermixing observed in the samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gold-gold luminosity increase in RHIC for a beam energy scan with colliding beam energies extending below the nominal injection energy

The Beam Energy Scan phase II (BES-II), performed in the Relativistic Heavy Ion Collider (RHIC) from 2019 to 2021, explored the phase transition between quark-gluon plasma and hadronic gas. BES-II exceeded the goal of a fourfold increase in the average luminosity over that achieved during Beam Energy Scan phase I (BES-I), at five gold beam energies: 9.8, 7.3, 5.75, 4.59, and 3.85 GeV / nucleon. This was accomplished by addressing several beam dynamics effects, including intrabeam scattering, beam-beam, space charge, beam instability, and field errors induced by superconducting magnet persistent currents. Some of these effects are especially detrimental at low energies. BES-II achievements are presented, and the measures taken to improve RHIC performance are described. These measures span the whole RHIC complex, including ion beam sources, injectors, beam lifetime improvements in RHIC, and operation with the world’s first bunched beam Low Energy RHIC electron Cooler (LEReC).

43 PARTICLE ACCELERATORS↗