Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Identification and characterization of DNAzymes targeting DNA methyltransferase I for suppressing bladder cancer proliferation

Epigenetic inactivation of genes plays a critical role in many important human diseases, especially in cancer. A core mechanism for epigenetic inactivation of the genes is methylation of CpG islands in genome DNA, which is catalyzed by DNA methyltransferases (DNMTs). The inhibition of DNMTs may lead to demethylation and expression of the silenced tumor suppressor genes. Although DNMT inhibitors are currently being developed as potential anticancer agents, only limited success is achieved due to substantial toxicity. Here, we utilized a multiplex selection system to generate efficient RNA-cleaving DNAzymes targeting DNMT1. The lead molecule from the selection was shown to possess efficient kinetic profiles and high efficiency in inhibiting the enzyme activity. Transfection of the DNAzyme caused significant down-regulation of DNMT1 expression and reactivation of p16 gene, resulting in reduced cell proliferation of bladder cancers. This study provides an alternative for targeting DNMTs for potential cancer therapy. - Highlights: • Identified DNMT1-targeted DNAzymes by multiplex selection system. • Biochemically characterized a lead DNAzyme with high kinetic efficiency. • Validated DNMT1-targeted DNAzyme in its enzymatic and cellular activities.

60 APPLIED LIFE SCIENCES↗

NK cell and IFN signatures are positive prognostic biomarkers for resectable pancreatic cancer

Highlights: • Integrative immunomonitoring was undertaken in resected pancreatic cancer patients. • Immunomonitoring employed flow cytometry, multiplex-bead assays and RMA-Seq. • Higher NK cell % in peripheral blood are associated with better prognosis. • Type I and II IFN signatures in the tumor are associated with better prognosis. • Epithelial mesenchymal transition is associated with early recurrence. To establish prognostic biomarkers and to identify potential novel therapeutic targets, we performed integrative immunomonitoring of blood and tumor in patients with resectable pancreatic cancer. Flow cytometry (FC) was employed for phenotyping immune cells, multiplex bead assays for plasma cytokine and chemokine determination, and RNA-Seq for the analysis of gene expression in the tumor. Nineteen pancreatic cancer patients were stratified into those with longer or shorter than median recurrence-free survival after surgery (median, 426 days). There were no significant differences between the two groups for clinical parameters including age, sex, surgical procedure, stage, or postoperative adjuvant therapy. However, we found that the percentages of NK cells as assessed by FC in peripheral blood mononuclear cells were higher in patients with late recurrence (P = .037). RNA-Seq data indicated no differences in the amount of immune cells or stromal cells between the two groups, although NK cells in the tumor did tend to be higher in patients with late recurrence (P = .058). Type I and II IFN signatures were enriched in late-recurring tumors (FDR q-value <0.001), while genes related to KRAS signaling and the epithelial mesenchymal transition (EMT) were enriched in early recurrence. We conclude that tumor-intrinsic properties of metastasis and recurrence influence prognosis, whereas NK cells that might contribute to prevent metastasis are associated with longer recurrence-free survival. Therefore, enhancement of NK cell activity and inhibition of the EMT and KRAS signaling might represent appropriate therapeutic targets following surgical resection of pancreatic cancer.

60 APPLIED LIFE SCIENCES↗

The need for non- or minimally-invasive biomonitoring strategies and the development of pharmacokinetic/pharmacodynamic models for quantification

Advancements in Exposure Science involving the development and deployment of biomarkers of exposure and biological response are anticipated to significantly (and positively) influence health outcomes associated with occupational, environmental and clinical exposure to chemicals/drugs. To achieve this vision, innovative strategies are needed to develop multiplex sensor platforms capable of quantifying individual and mixed exposures (i.e. systemic dose) by measuring biomarkers of dose and biological response in readily obtainable (non-invasive) biofluids. Secondly, the use of saliva (alternative to blood) for biomonitoring coupled with the ability to rapidly analyze multiple samples in real-time offers an innovative opportunity to revolutionize biomonitoring assessments. In this regard, the timing and number of samples taken for biomonitoring will not be limited as is currently the case. In addition, real-time analysis will facilitate identification of work practices or conditions that are contributing to increased exposures and will make possible a more rapid and successful intervention strategy. The initial development and application of computational models for evaluation of saliva/blood analyte concentration at anticipated exposure levels represents an important opportunity to establish the limits of quantification and robustness of multiplex sensor systems by exploiting a unique computational modeling framework. The use of these pharmacokinetic models will also enable prediction of an exposure dose based on the saliva/blood measurement. This novel strategy will result in a more accurate prediction of exposures and, once validated, can be employed to assess dosimetry to a broad range of chemicals in support of biomonitoring and epidemiology studies.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative analysis of various CO 2 configurations in supermarket refrigeration systems

Our paper presents an analysis of various CO 2 transcritical and cascade/secondary loop refrigeration systems that are becoming popular in supermarket applications with the objective of optimizing the operating parameters of these systems. In addition, the performance of selected CO 2 -based refrigeration systems is compared to the baseline R404A multiplex direct expansion system using bin analyses in the eight climate zones of the United States. Moreover, for the refrigeration systems investigated, it was found that the Transcritical Booster System with Bypass Compressor (TBS-BC) had the lowest energy consumption for ambient temperatures (T amb ) less than 8 °C, and for higher ambient temperatures the R404A direct expansion system was found to have the lowest energy consumption. Finally, the TBS-BC performs equivalent to or better than the R404A direct expansion system in the northern two-thirds of the US. For the southern portion of the US, the R404A multiplex DX system performs better than CO 2 systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

A landing pad system for multicopy gene integration in Issatchenkia orientalis

The robust nature of the non-conventional yeast Issatchenkia orientalis allows it to grow under highly acidic conditions and therefore, has gained increasing interest in producing organic acids using a variety of carbon sources. Recently, the development of a genetic toolbox for I. orientalis, including an episomal plasmid, characterization of multiple promoters and terminators, and CRISPR-Cas9 tools, has eased the metabolic engineering efforts in I. orientalis. However, multiplex engineering is still hampered by the lack of efficient multicopy integration tools. To facilitate the construction of large, complex metabolic pathways by multiplex CRISPR-Cas9-mediated genome editing, we developed a bioinformatics pipeline to identify and prioritize genome-wide intergenic loci and characterized 47 gRNAs located in 21 intergenic regions. These loci are screened for guide RNA cutting efficiency, integration efficiency of a gene cassette, the resulting cellular fitness, and GFP expression level. We further developed a landing pad system using components from these well-characterized loci, which can aid in the integration of multiple genes using single guide RNA and multiple repair templates of the user’s choice. We have demonstrated the use of the landing pad for simultaneous integrations of 2, 3, 4, or 5 genes to the target loci with efficiencies greater than 80%. As a proof of concept, we showed how the production of 5-aminolevulinic acid can be improved by integrating five copies of genes at multiple sites in one step. We have further demonstrated the efficiency of this tool by constructing a metabolic pathway for succinic acid production by integrating five gene expression cassettes using a single guide RNA along with five different repair templates, leading to the production of 9 g/L of succinic acid in batch fermentations. Furthermore, this study demonstrates the effectiveness of a single gRNA-mediated CRISPR platform to build complex metabolic pathways in a non-conventional yeast. This landing pad system will be a valuable tool for the metabolic engineering of I. orientalis.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Long-gradient separations coupled to tandem MS were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional LC-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in LOQ for target proteins in human female serum. Based on at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in non-depleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or sub-ng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and ELISA measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM offers at least 3 times higher multiplexing capacity than conventional LC-SRM due to ~3-fold increase in average peak widths for a 300-min gradient compared to a 45-min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Shi, Tujin↗

Development of a Universal Second-Tier Newborn Screening LC–MS/MS Method for Amino Acids, Lysophosphatidylcholines, and Organic Acids

First-tier MS-based newborn screening by flow injection analysis can have high presumptive positive rates, often due to isomeric/isobaric compounds or poor biomarker specificity. These presumptive positive samples can be analyzed by second-tier screening assays employing separations such as liquid chromatography–mass spectrometry (LC–MS/MS), which increases test specificity and drastically reduces false positive referrals. The ability to screen for multiple disorders in a single multiplexed test simplifies workflows and maximizes public health laboratories’ resources. In this study, we developed and validated a highly multiplexed second-tier method for dried blood spots using a hydrophilic interaction liquid chromatography (HILIC) column coupled to an MS/MS system. The LC–MS/MS method was capable of simultaneously detecting second-tier biomarkers for maple syrup urine disease, homocystinuria, methylmalonic acidemia, propionic acidemia, glutaric acidemia type 1, glutaric acidemia type 2, guanidinoacetate methyltransferase deficiency, short-chain acyl-CoA dehydrogenase deficiency, adrenoleukodystrophy, and Pompe disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colorimetric-Luminance Readout for Quantitative Analysis of Fluorescence Signals with a Smartphone CMOS Sensor

Smartphones have shown promise as an enabling technology for portable and distributed point-of-care diagnostic tests. The CMOS camera sensor can be used for detecting optical signals, including fluorescence for applications such as isothermal nucleic acid amplification tests. However, such analysis is typically limited mostly to end point detection of single targets. In this paper, we present a smartphone-based image analysis pipeline that utilizes the CIE xyY (chromaticity-luminance) color space to measure the luminance (in lieu of RGB intensities) of fluorescent signals arising from nucleic acid amplification targets, with a discrimination sensitivity (ratio between the positive to negative signals), which is an order of magnitude more than traditional RGB intensity based analysis. Furthermore, the chromaticity part of the analysis enables reliable multiplexed detection of different targets labeled with spectrally separated fluorophores. We apply this chromaticity-luminance formulation to simultaneously detect Zika and chikungunya viral RNA via end point RT-LAMP (Reverse transcription Loop-Mediated isothermal amplification). We also show real time LAMP detection of Neisseria gonorrhoeae samples down to a copy number of 3.5 copies per 10 μL of reaction volume in our smartphone-operated portable LAMP box. Finally, our chromaticity-luminance analysis is readily adaptable to other types of multiplexed fluorescence measurements using a smartphone camera.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carrier-Assisted Single-Tube Processing Approach for Targeted Proteomics Analysis of Low Numbers of Mammalian Cells

Heterogeneity in composition is inherent in all cell populations, even those containing a single cell type. Single-cell proteomics characterization of cell heterogeneity is currently achieved by antibody-based technologies, which are limited by the availability of highquality antibodies. In this paper we report a simple, easily implemented, mass spectrometry (MS)- based targeted proteomics approach, termed cLC-SRM (carrier-assisted liquid chromatography coupled to selected reaction monitoring), for reliable multiplexed quantification of proteins in low numbers of mammalian cells. We combine a new single-tube digestion protocol to process low numbers of cells with minimal loss together with sensitive LC-SRM for protein quantification. This single-tube protocol builds upon trifluoroethanol digestion and further minimizes sample losses by tube pretreatment and the addition of carrier proteins. We also optimized the denaturing temperature and trypsin concentration to significantly improve digestion efficiency. cLC-SRM was demonstrated to have sufficient sensitivity for reproducible detection of most epidermal growth factor receptor (EGFR) pathway proteins expressed at levels =30 000 and =3000 copies per cell for 10 and 100 mammalian cells, respectively. Thus, cLC-SRM enables reliable quantification of low to moderately abundant proteins in less than 100 cells and could be broadly useful for multiplexed quantification of important proteins in small subpopulations of cells or in size-limited clinical samples. Further improvements of this method could eventually enable targeted single-cell proteomics when combined with either SRM or other emerging ultrasensitive MS detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Boosting to Amplify Signal with Isobaric Labeling (BASIL) Strategy for Comprehensive Quantitative Phosphoproteomic Characterization of Small Populations of Cells

Comprehensive phosphoproteomic analysis of small populations of cells remains a daunting task due primarily to the insufficient MS signal intensity from low concentrations of enriched phosphopeptides. Isobaric labeling has a unique multiplexing feature where the “total” peptide signal from all channels (or samples) triggers MS/MS fragmentation for peptide identification while the reporter ions provide quantitative information. In light of this feature, we tested the concept of using a “boosting” sample (e.g., a biological sample mimicking the study samples but available in much larger quantity) in multiplexed analysis to enable sensitive and comprehensive quantitative phosphoproteomic measurements with <100,000 cells. This simple Boosting to Amplify Signal with Isobaric Labeling (BASIL) strategy increased the overall number of quantifiable phosphorylation sites more than 4-fold. Good reproducibility in quantification was demonstrated with a median CV of 15.3% and Pearson correlation coefficient of 0.95 from biological replicates. A proof-of-concept experiment demonstrated the ability of BASIL to distinguish acute myeloid leukemia cells based on the phosphoproteome data. Moreover, in a pilot application, this strategy enabled quantitative analysis of over 20,000 phosphorylation sites from human pancreatic islets treated with interleukin-1ß and interferon-gamma. Together, this signal boosting strategy provides an attractive solution to comprehensive and quantitative phosphoproteome profiling of relatively small populations of cells where traditional phosphoproteomic workflows provide insufficient sensitivity.

phosphorylation, phosphoproteomics, pancreatic isl↗

New Insights into Low-Temperature Oxidation of Propane from Synchrotron Photoionization Mass Spectrometry and Multiscale Informatics Modeling

We investigated the low-temperature oxidation of propane at 4 Torr and temperatures of 530, 600, and 670 K. The oxidation is initiated by pulsed laser photolysis of oxalyl chloride, (COCl)2, at 248 nm, which rapidly generates a ~1:1 mixture of 1-propyl (n-propyl) and 2-propyl (i-propyl) radicals via the fast Cl + propane reaction. Reactants, intermediates and products are probed with isomeric selectivity by time-resolved multiplexed photoionization mass spectrometry (MPIMS) with tunable synchrotron vacuum UV radiation as the ionization source. At all three temperatures, the major stable product species is propene, formed in the C3H7 + O2 reactions by direct HO2-elimination from both n- and i-propyl peroxy radicals. The experimentally derived propene yields relative to the initial concentration of Cl atoms are (20 ± 4)% at 530 K, (55 ± 11)% at 600 K, and (86 ± 17)% at 670 K at a reaction time of 20 ms. The lower yield of propene at low temperature reflects substantial formation of propyl peroxy radicals, which do not completely decompose on the experimental time scale. In addition, we detect the C3H6O isomers methyloxirane, oxetane, acetone and propanal as minor products. Our measured yields of oxetane and methyloxirane, which are co-products of OH radicals, suggest a revision of the OH formation pathways in models of low-temperature propane oxidation. The experimental results are modeled and interpreted using a multi-scale informatics approach that is presented in detail in a separate publication (Burke, M. P.; Goldsmith, C. F.; Klippenstein, S. J.; Welz, O.; Huang H.; Antonov I. O.; Savee J. D.; Osborn D. L.; Zádor, J.; Taatjes, C. A.; Sheps, L., Multi-Scale Informatics for Low-Temperature Propane Oxidation: Further Complexities in Studies of Complex Rections, submitted, 2015). The model predicts the time profiles and yields of the experimentally observed primary products well, and shows satisfactory agreement for products formed mostly via secondary radical-radical reactions.

Combustion↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Engineering an efficient and bright split Corynactis californica green fluorescent protein

Split green fluorescent protein (GFP) has been used in a panoply of cellular biology applications to study protein translocation, monitor protein solubility and aggregation, detect protein–protein interactions, enhance protein crystallization, and even map neuron contacts. Recent work shows the utility of split fluorescent proteins for large scale labeling of proteins in cells using CRISPR, but sets of efficient split fluorescent proteins that do not cross-react are needed for multiplexing experiments. We present a new monomeric split green fluorescent protein (ccGFP) engineered from a tetrameric GFP found in Corynactis californica, a bright red colonial anthozoan similar to sea anemones and scleractinian stony corals. Split ccGFP from C. californica complements up to threefold faster compared to the original Aequorea victoria split GFP and enable multiplexed labeling with existing A. victoria split YFP and CFP.

59 BASIC BIOLOGICAL SCIENCES↗

Multivariate chemogenomic screening prioritizes new macrofilaricidal leads

Development of direct acting macrofilaricides for the treatment of human filariases is hampered by limitations in screening throughput imposed by the parasite life cycle. In vitro adult screens typically assess single phenotypes without prior enrichment for chemicals with antifilarial potential. We developed a multivariate screen that identified dozens of compounds with submicromolar macrofilaricidal activity, achieving a hit rate of >50% by leveraging abundantly accessible microfilariae. Adult assays were multiplexed to thoroughly characterize compound activity across relevant parasite fitness traits, including neuromuscular control, fecundity, metabolism, and viability. Seventeen compounds from a diverse chemogenomic library elicited strong effects on at least one adult trait, with differential potency against microfilariae and adults. Our screen identified five compounds with high potency against adults but low potency or slow-acting microfilaricidal effects, at least one of which acts through a novel mechanism. We show that the use of microfilariae in a primary screen outperforms model nematode developmental assays and virtual screening of protein structures inferred with deep learning. These data provide new leads for drug development, and the high-content and multiplex assays set a new foundation for antifilarial discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Fiber optic computing using distributed feedback

Abstract The widespread adoption of machine learning and other matrix intensive computing algorithms has renewed interest in analog optical computing, which has the potential to perform large-scale matrix multiplications with superior energy scaling and lower latency than digital electronics. However, most optical techniques rely on spatial multiplexing, requiring a large number of modulators and detectors, and are typically restricted to performing a single kernel convolution operation per layer. Here, we introduce a fiber-optic computing architecture based on temporal multiplexing and distributed feedback that performs multiple convolutions on the input data in a single layer. Using Rayleigh backscattering in standard single mode fiber, we show that this technique can efficiently apply a series of random nonlinear projections to the input data, facilitating a variety of computing tasks. The approach enables efficient energy scaling with orders of magnitude lower power consumption than GPUs, while maintaining low latency and high data-throughput.

97 MATHEMATICS AND COMPUTING↗

2-20 ns interframe time 2-frame 6.151 keV x-ray imaging on the recently upgraded Z Accelerator: A progress report

When used for the production of an x-ray imaging backlighter source on Sandia National Laboratories' recently upgraded 26 MA Z Accelerator, the terawatt-class, multikilojoule, 526.57 nm Z-Beamlet laser (ZBL) [P. K. Rambo et al., Appl. Opt. 44, 2421 (2005)], in conjunction with the 6.151 keV (1s{sup 2}-1s2p triplet line of He-like Mn) curved-crystal imager [D. B. Sinars et al., Rev. Sci. Instrum. 75, 3672 (2004); G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)], is capable of providing a high quality x radiograph per Z shot for inertial confinement fusion (ICF), complex hydrodynamics, and other high-energy-density physics experiments. For example, this diagnostic has recently afforded microgram-scale mass perturbation measurements on an imploding ignition-scale 1 mg ICF capsule [G. R. Bennett et al., Phys. Rev. Lett. 99, 205003 (2007)], where the perturbation was initiated by a surrogate deuterium-tritium (DT) fuel fill tube. Using an angle-time multiplexing technique, ZBL now has the capability to provide two spatially and temporally separated foci in the Z chamber, allowing 'two-frame' imaging to be performed, with an interframe time range of 2-20 ns. This multiplexing technique allows the full area of the four-pass amplifiers to be used for the two pulses, rather than split the amplifiers effectively into two rectangular sections, with one leg delayed with respect to the other, which would otherwise double the power imposed onto the various optics thereby halving the damage threshold, for the same irradiance on target. The 6.151 keV two frame technique has recently been used to image imploding wire arrays, using a 7.3 ns interframe time. The diagnostic will soon be converted to operate with p-rather than s-polarized laser light for enhanced laser absorption in the Mn foil, plus other changes (e.g., operation at the possibly brighter 6.181 keV Mn 1s{sup 2}-1s2p singlet line), to increase x-ray yields. Also, a highly sensitive inline multiframe ultrafast (1 ns gate time) digital x-ray camera is being developed [G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)] to extend the system to 'four-frame' and markedly improve the signal-to-noise ratio. [At present, time-integrating Fuji BAS-TR2025 image plate (scanned with a Fuji BAS-5000 device) forms the time-integrated image-plane detector.].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗