Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

IXO/XMS Detector Trade-Off Study

This document presents the outcome of the detector trade-off for the XMS instrument on IXO. This trade-off is part of the Cryogenic instrument Phase-A study as proposed to ESA in the Declaration of Interest SRONXMS-PL-2009-003 dated June 6, 2009. The detector consists of two components: a core array for the highest spectral resolution and an outer array to increase the field of view substantially with modest increase in the number of read-out channels. Degraded resolution of the outer array in comparison with the core array is accepted in order to make this scheme possible. The two detector components may be a single unit or separate units. These arrays comprise pixels and the components that allow them to be arrayed. Each pixel comprises a thermometer, an absorber, and the thermal links between them and to the rest of the array. These links may be interfaces or distinct components. The array infrastructure comprises the mechanical structure of the array, the arrangement of the leads, and features added to improve the integrated thermal properties of the array in the focal-plane assembly.

Kilbourne, Caroline Anne↗

Pseudoslit Spectrometer

The pseudoslit spectrometer is a conceptual optoelectronic instrument that would offer some of the advantages, without the disadvantages, of prior linear-variable etalon (LVE) spectrometers and prior slit spectrometers. The pseudoslit spectrometer is so named because it would not include a slit, but the combined effects of its optical components would include a spatial filtering effect approximately equivalent to that of a slit. Like a prior LVE spectrometer, the pseudoslit spectrometer would include an LVE (essentially, a wedge-like narrowband- pass filter, the pass wavelength of which varies linearly with position in one dimension) in a focal plane covering an imaging planar array of photodetectors. However, the pseudoslit spectrometer would be more efficient because unlike a prior LVE spectrometer, the pseudoslit spectrometer would not have to be scanned across an entire field of view to obtain the spectrum of an object of interest that may occupy only a small portion of the field of view. Like a prior slit spectrometer, the pseudoslit spectrometer could acquire the entire spectrum of such a small object without need for scanning. However, the pseudoslit spectrometer would be optically and mechanically simpler: it would have fewer components and, hence, would pose less of a problem of alignment of components and would be less vulnerable to misalignment.

Reuter, Dennis C.↗

High Speed Inlet Distortion Test for the X 59 Low Boom Flight Demonstrator in the NASA Glenn 8-by 6-Foot Supersonic Wind Tunnel

The Low Boom Flight Demonstrator (LBFD) High Speed Inlet Distortion Test (HSIDT) was completed in the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel (8x6 SWT) using a 9.5 percent-scale propulsion model of the X–59 to evaluate the compatibility and operability of the inlet and engine integration, focusing on the inlet dynamic effects at the engine face. The model was instrumented with steady-state and high-response total pressure probes in the conventional 40-point, equal-area array at the aerodynamic interface plane (AIP). The HSIDT successfully collected high response distortion data points for the X–59 from Mach = 0 to 1.55 for a wide range of angle-of-attack, angle-of-sideslip, and inlet flow. Analyses showed that inlet dynamic distortion and inlet planar wave (or inlet buzz) were within engine limits through most of the flight envelope. The test data showed that inlet planar wave was present at Mach 1.35 and above, at airflows between idle and maximum engine airflow. Engine throttle back will need to be limited when decelerating from supersonic flight Mach to avoid these regions of inlet planar wave. The HSIDT data was also used to compare the metric SUM40, computed from the 40 high-response AIP total pressure probes, with the metric SUM4, computed from four high-response inlet static pressure probes. The data showed that SUM4 can be used as a surrogate for SUM40 during the X–59 flight test to detect inlet planar wave.

X-59↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Image-plane processing of visual information

Shannon's theory of information is used to optimize the optical design of sensor-array imaging systems which use neighborhood image-plane signal processing for enhancing edges and compressing dynamic range during image formation. The resultant edge-enhancement, or band-pass-filter, response is found to be very similar to that of human vision. Comparisons of traits in human vision with results from information theory suggest that: (1) Image-plane processing, like preprocessing in human vision, can improve visual information acquisition for pattern recognition when resolving power, sensitivity, and dynamic range are constrained. Improvements include reduced sensitivity to changes in lighter levels, reduced signal dynamic range, reduced data transmission and processing, and reduced aliasing and photosensor noise degradation. (2) Information content can be an appropriate figure of merit for optimizing the optical design of imaging systems when visual information is acquired for pattern recognition. The design trade-offs involve spatial response, sensitivity, and sampling interval.

Huck, F. O.↗

Millimeter-wave diode-grid frequency doubler

Monolithic diode grids were fabricated on 2-cm square gallium-arsenide wafers in a proof-of-principle test of a quasi-optical varactor millimeter-wave frequency multiplier array concept. An equivalent circuit model based on a transmission-line analysis of plane wave illumination was applied to predict the array performance. The doubler experiments were performed under far-field illumination conditions. A second-harmonic conversion efficiency of 9.5 percent and output powers of 0.5 W were achieved at 66 GHz when the diode grid was pumped with a pulsed source at 33 GHz. This grid had 760 Schottky-barrier varactor diodes. The average series resistance was 27 ohms, the minimum capacitance was 18 fF at a reverse breakdown voltage of -3 V. The measurements indicate that the diode grid is a feasible device for generating watt-level powers at millimeter frequencies and that substantial improvement is possible by improving the diode breakdown voltage.

Jou, Christina F.↗

Systems and methods that generate height map models for efficient three dimensional reconstruction from depth information

Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.

42 ENGINEERING↗

On the Mutual Coupling between Circular Resonant Slots

For near- and far-field microwave imaging purposes, array of circular resonant slots can be utilized to sample the electric field at a given reference plane. In general, the sensitivity of such an array is impaired by the existing mutual coupling between the radiating elements or in this case circular slots. The mutual coupling problem imposes a design tradeoff between the resolution of the array and the overall system sensitivity and dynamic range. In this paper, the mutual coupling between circular resonant slots in conducting ground plane is investigated both numerically and experimentally. In particular, the mutual coupling in the E- and H-plane configurations of two identical slots is studied.

Abou-Khousa, M. A.↗

In-plane plasmon coupling in topological insulator Bi 2 Se 3 thin films

The surface states of the 3D topological insulator (TI), Bi 2 Se 3 , are known to host two-dimensional Dirac plasmon polaritons (DPPs) in the terahertz spectral range. In TI thin films, the DPPs excited on the top and bottom surfaces couple, leading to an acoustic mode and an optical plasmon mode. Vertical coupling in these materials is, therefore, reasonably well-understood, but in-plane coupling among localized TI DPPs has yet to be investigated. In this paper, we demonstrate in-plane DPP coupling in TI stripe arrays and show that they exhibit dipole–dipole type coupling. Here, the coupling becomes negligible when the lattice constant is greater than approximately 2.8 times the stripe width, which is comparable to results for in-plane coupling of localized plasmons excited on metallic nanoparticles or graphene plasmon polaritons. This understanding could be leveraged for the creation of TI-based metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Array feeds for reflector surface distortion compensation - Concepts and implementation

The development of a compensation algorithm based on the use of array feeds and a focal-plane conjugate field approach is discussed. Results of numerical simuations performed to verify the accuracy of the computer programs are examined, and an experimental study is described. Both the numerical and experimental results show that the array will compensate for the slowly varying surface distortion. In particular, for some typical, slowly varying thermal or gravitational surface distortions, a 19-element array feed can improve the reflector performance considerably. Additionally, it is demonstrated that it will be possible to compensate for the surface distortion without actual knowledge of the distortion itself.

Rahmat-Samii, Yahya↗

Multispectral linear array multiband selection device

An apparatus for detecting multiple spectral bands, individually or concurrently, using linear detector arrays is described. The system employs a beamsplitter to divide the optical source into two or more optical beams which are directed at the linear detector arrays. Filter trays are positioned in the focal planes of the optical beams so that the beams pass through the filter trays prior to impinging upon the detector arrays. Multiple filters are placed on the filter trays. Linear actuators positioned adjacent the filter trays translate the trays across the focal planes of the optical beams so that individual filters are positioned in the path of beams such that those frequencies of the beams that fall within the spectral ranges of the individual bandpass filter through which it passes may be detected by the detector arrays for further examination and analysis.

Richard, H. L.↗

SU-F-T-430: Validation of IBEAM Evo Couch Top for Different Relative Electron Density (RED) Combination During Photon Beam Dose Calculation in Monaco− Treatment Planning System

Purpose: Validation of iBEAM™ evo couch-top for different relative electron density (RED) combination during photon beam dose calculation in Monaco− TPS. Methods: The iBEAM™ evo couch-top has two layers:outer carbon fiber (CF) and inner foam core (FC). To study the beam intensity attenuation of couch-top, measured doses were compared with doses calculated for different REDs. Measurements were performed in solid water phantom with PTW-0.125cc ion-chamber positioned at center of the phantom with 5.3cm thickness slabs placed above and below the chamber. Similarly, in TPS, iBEAM™ evo couch-top was simulated and doses were calculated for different RED combinations (0.2CF-0.2FC, 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC) by using Monte Carlo dose calculation algorithm in Monaco TPS (V5.1). Doses were measured for every 10 degree gantry angle separation, 10×10cm{sup 2} field size and 6MV photons. Then, attenuation is defined as the ratio of output at posterior gantry angle to output of its opposed anterior gantry angle (e.g.225°/45°). output fluctuation with different gantry angle was within ±0.21%. To confirm above results, dose-planes were measured for five pelvic VMAT plans (360°arc) in PTW two-dimensional array and compared with different calculated dose-planes of above-mentioned couch REDs. Gamma pass rates<1.00) were analyzed for 3%/2mm criteria. Results: Measured and calculated attenuation was in good agreement for the RED combination of 0.2CF-0.2FC and difference was within ±0.515%. However, other density combination showed difference of ±0.9841%, ±1.667%, ±2.9241% and ±2.8832% for 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC, respectively. Maximum couch-top attenuation was observed at 110°–120° and 240°–250° and decreases linearly as the gantry angle approaches 180°. Moreover, gamma pass rate confirmed the above results and showed maximum pass rate of 96.23% for 0.2CF-0.2FC, whereas others were 95.72%, 95.12%, 94.31% and 93.24%. Conclusion: RED value of 0.2CF-0.2FC was found to be suitable for accurate couch-top modeling for 6MV photon beam Monte Carlo calculations in Monaco TPS.

07 ISOTOPE AND RADIATION SOURCES↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

Discrete mechanism damping effects in the solar array flight experiment

Accelerometer data were collected during on-orbit structural dynamic testing of the Solar Array Flight Experiment aboard the Space Shuttle, and were analyzed at Lockheed Missile and Space Co. to determine the amount of damping present in the structure. The results of this analysis indicated that the damping present in the fundamental in-plane mode of the structure substantially exceeded that of the fundamental out-of-plane mode. In an effort to determine the source of the higher in-plane damping, a test was performed involving a small device known as a constant-force spring motor or constant-torque mechanism. Results from this test indicate that this discrete device is at least partially responsible for the increased in-plane modal damping of the Solar Array Flight Experiment structure.

Pinson, E. D.↗

A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom

Purpose: The Australian Clinical Dosimetry Service (ACDS) has implemented a new method of a nonreference condition Level II type dosimetric audit of radiotherapy services to increase measurement accuracy and patient safety within Australia. The aim of this work is to describe the methodology, tolerances, and outcomes from the new audit. Methods: The ACDS Level II audit measures the dose delivered in 2D planes using an ionization chamber based array positioned at multiple depths. Measurements are made in rectilinear homogeneous and inhomogeneous phantoms composed of slabs of solid water and lung. Computer generated computed tomography data sets of the rectilinear phantoms are supplied to the facility prior to audit for planning of a range of cases including reference fields, asymmetric fields, and wedged fields. The audit assesses 3D planning with 6 MV photons with a static (zero degree) gantry. Scoring is performed using local dose differences between the planned and measured dose within 80% of the field width. The overall audit result is determined by the maximum dose difference over all scoring points, cases, and planes. Pass (Optimal Level) is defined as maximum dose difference ≤3.3%, Pass (Action Level) is ≤5.0%, and Fail (Out of Tolerance) is >5.0%. Results: At close of 2013, the ACDS had performed 24 Level II audits. 63% of the audits passed, 33% failed, and the remaining audit was not assessable. Of the 15 audits that passed, 3 were at Pass (Action Level). The high fail rate is largely due to a systemic issue with modeling asymmetric 60° wedges which caused a delivered overdose of 5%–8%. Conclusions: The ACDS has implemented a nonreference condition Level II type audit, based on ion chamber 2D array measurements in an inhomogeneous slab phantom. The powerful diagnostic ability of this audit has allowed the ACDS to rigorously test the treatment planning systems implemented in Australian radiotherapy facilities. Recommendations from audits have led to facilities modifying clinical practice and changing planning protocols.

60 APPLIED LIFE SCIENCES↗

Multispectral linear array

The Multispectral Linear Array (MLA) is a solid-state earth imagery radiometer operating in the 'push-broom' mode and using a focal plane containing multiple spectral band linear detector arrays. The MLA sensor offers the capability for increased spatial and spectral resolution with multiple selectable bands and in-orbit operation flexibility. Both free-flyer (satellite) and Shuttle-attached instrument designs have been studied. Four Shuttle-attached MLA instrument design studies were initiated in 1982, and the concepts resulting from these studies are described.

Richard, H. L.↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗