Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Precision Time Protocol Performance Testing Over Optical Transport Network

The US Department of Energy Office of Electricity has partnered with Oak Ridge National Laboratory (ORNL) to find alternative precision timing solutions for the nation’s power grid. This effort is in response to the vulnerabilities identified in the Global Navigation Satellite System (GNSS), of which the US Global Positioning System (GPS) platform is a part. Additionally, Executive Order 139055 has highlighted the need for alternative or backup timing solutions. ORNL has established a Timing Lab and has been testing various technologies and timing devices as part of this effort. Precision Time Protocol (PTP), and the off-the-shelf timing devices and network connections that support it, are among the alternatives being tested. This work reports the accuracy of PTP over an Optical Transport Network (OTN) and is part of a series published by the Center for Alternative Synchronization and Timing (CAST).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutrino-Nucleus Interactions in the Precision Era

Current and future accelerator-based neutrino facilities, leveraging intense neutrino beams and advanced detectors, aim to precisely determine neutrino properties and probe signals of weakly interacting beyond the Standard Model physics. Achieving discovery-level precision and fully exploring the physics potential of these experiments critically depends on the accuracy of our understanding of fundamental underlying neutrino-nucleus interaction processes. This talk will focus on neutrino interactions spanning energies from tens of MeV to a few GeV a complex, multi-scale and multi-process domain spanning from low-energy nuclear physics to perturbative QCD, with no unified underlying framework currently known. In this talk, I will provide an overview of the field, discuss recent advancements, and share examples of ongoing cross-community efforts addressing these challenges.

Pandey, Vishvas [Fermilab] (ORCID:0000000230827987↗

Precision Electroweak Measurements and Constraints on the Standard Model

This note presents constraints on Standard Model parameters using published and preliminary precision electroweak results measured at the electron-positron colliders LEP and SLC. The results are compared with precise electroweak measurements from other experiments, notably CDF and D{\O}at the Tevatron. Constraints on the input parameters of the Standard Model are derived from the combined set of results obtained in high-$Q^2$ interactions, and used to predict results in low-$Q^2$ experiments, such as atomic parity violation, M{\o}ller scattering, and neutrino-nucleon scattering. The main changes with respect to the experimental results presented in 2008 are new combinations of results on the W-boson mass and the mass of the top quark.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

An Ultra-Precise System for Electrical Resistivity Tomography Measurements

The objective of this research was to determine the feasibility of building and operating an ERT system that will allow measurement precision that is an order of magnitude better than existing systems on the market today and in particular if this can be done without significantly greater manufacturing or operating costs than existing commercial systems. Under this proposal, we performed an estimation of measurement errors in galvanic resistivity data that arise as a consequence of the type of electrode material used to make the measurements. In our laboratory, measurement errors for both magnitude and induced polarization (IP) were estimated using the reciprocity of data from an array of electrodes as might be used for electrical resistance tomography using 14 different metals as well as one non-metal - carbon. In a second phase of this study, using archival data from two long-term ERT surveys, we examined long-term survivability of electrodes over periods of several years. The survey sites were: the Drift Scale Test at Yucca Mountain, Nevada (which was sponsored by the U. S. Department of Energy as part of the civilian radioactive waste management program), and a water infiltration test at a site adjacent to the New Mexico Institute of Mines and Technology in Socorro, New Mexico (sponsored by the Sandia/Tech vadose program). This enabled us to compare recent values with historical values and determine electrode performance over the long-term as well as the percentage of electrodes that have failed entirely. We have constructed a prototype receiver system, made modifications and revised the receiver design. The revised prototype uses a new 24 bit analog to digital converter from Linear Technologies with amplifier chips from Texas Instruments. The input impedance of the system will be increased from 107 Ohms to approximately 1010 Ohms. The input noise level of the system has been decreased to approximately 10 Nanovolts and system resolution to about 1 Nanovolt at the highest gain range of 125 to 1. The receiver also uses very high precision and high temperature stability components. The goal is to improve the accuracy to better than 0.1%. The system has more receiver channels, eight, to allow efficient data collection at lower base frequencies. We are also implementing a frequency-domain acquisition mode in addition to the time-domain acquisition mode used in the earlier systems. Initial field tests were started in the fall of 2008. We conducted tests on a number of types of cable commonly used for resistivity surveys. A series of different tests were designed to determine if the couplings were primarily resistive, capacitive, or inductive in nature and to ascertain that the response was due to the cable cross-talk and did not depend on the receiver electronics. The results show that the problem appears to be primarily capacitive in nature and does not appear to be due to problems in the receiver electronics. Thus a great deal of emphasis has been placed on finding appropriate cables as well as stable electrodes that have low contact impedance at the very low current flows observed at the receiver. One of the issues in survey design and data collection has been determining how long one must wait before using the same electrode as a transmitter and as a receiver. A series of tests was completed in the laboratory sand tank where four-electrode measurements were made using the same dipole transmitters and dipole receivers (the dipoles used adjacent electrodes). For each data series, a single set of normal measurements were collected with no reciprocals and electrodes were never reused as a receiver after being used as a transmitter. After waiting a specified length of time, the reciprocal measurements were collected using a schedule of measurements. The order of this second schedule was rearranged such that if this second set of measurements were performed without first using the normal schedule, no electrode would be used as a receiver after being used as a transmitter. For this study, we cannot conclude that increasing the wait time increased or decreased the reciprocal errors, only that there was not a dramatic change in results with different wait times. Another issue in ERT data collection is the potential for the transmitter as well as the receiver end of an ERT system to create problems with reciprocity readings. Existing ERT systems typically use a constant voltage source. For the transmitter dipole, a constant voltage source has low output impedance, whereas a constant current source has high output impedance. Therefore, we devised an experiment to determine if a constant current source transmitter might produce smaller errors than a constant voltage source. These preliminary results suggest there is little or no difference in either resistivity or chargeability reciprocal errors using a constant voltage or constant current dipole drive source.

47 OTHER INSTRUMENTATION↗

Precision Electroweak Measurements and Constraints on the Standard Model

This note presents constraints on Standard Model parameters using published and preliminary precision electroweak results measured at the electron-positron colliders LEP and SLC. The results are compared with precise electroweak measurements from other experiments, notably CDF and D0 at the Tevatron. Constraints on the input parameters of the Standard Model are derived from the combined set of results obtained in high-Q{sup 2} interactions, and used to predict results in low-Q{sup 2} experiments, such as atomic parity violation, Moeller scattering, and neutrino-nucleon scattering. The main changes with respect to the experimental results presented in 2008 are new combinations of results on the W-boson mass and the mass of the top quark.

43 PARTICLE ACCELERATORS↗

Precision Electroweak Measurements and Constraints on the Standard Model

This note presents constraints on Standard Model parameters using published and preliminary precision electroweak results measured at the electron-positron colliders LEP and SLC. The results are compared with precise electroweak measurements from other experiments, notably CDF and D0 at the Tevatron. Constraints on the input parameters of the Standard Model are derived from the combined set of results obtained in high-Q{sup 2} interactions, and used to predict results in low-Q{sup 2} experiments, such as atomic parity violation, Moeller scattering, and neutrino-nucleon scattering. The main changes with respect to the experimental results presented in 2008 are new combinations of results on the W-boson mass and the mass of the top quark.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Precision Measurement of the W Boson Mass with 1 Inverse Femtobarn of DZero Run IIa Data

This thesis is a detailed presentation of a precision measurement of the mass of the W boson. It has been obtained by analyzing W → ev decays. The data used for this analysis was collected from 2002 to 2006 with the D0 detector, during Run IIa of the Fermilab Tevatron collider. It corresponds to a total integrated luminosity of 1 fb -1 . With a sample of 499,830 W → ev candidate events, we obtain a mass measurement of M W = 80.401 ± 0.043 GeV. This is the most precise measurement from a single experiment to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision quantum algorithms for partial differential equations

Quantum computers can produce a quantum encoding of the solution of a system of differential equations exponentially faster than a classical algorithm can produce an explicit description. However, while high-precision quantum algorithms for linear ordinary differential equations are well established, the best previous quantum algorithms for linear partial differential equations (PDEs) have complexity poly(1/ϵ), where ϵ is the error tolerance. By developing quantum algorithms based on adaptive-order finite difference methods and spectral methods, we improve the complexity of quantum algorithms for linear PDEs to be poly(d,log(1/ϵ)), where d is the spatial dimension. Our algorithms apply high-precision quantum linear system algorithms to systems whose condition numbers and approximation errors we bound. We develop a finite difference algorithm for the Poisson equation and a spectral algorithm for more general second-order elliptic equations.

97 MATHEMATICS AND COMPUTING↗

Control of the Machining Precision in Thread Cutting

In research on thread cutting, the flaws inevitably arising in the first two and last two turns of the thread, when the process is unsteady, are analyzed. Specifically, insertion and removal of the tool from the workpiece are accompanied by abrupt change in thread diameter: abrupt decrease in the case of threads on shafts; and increase for threads in holes. That leads to the appearance of slots on assembly, thereby increasing the likelihood of accidents and other problems in thread operation. A method of eliminating such gaps is proposed and tested: control of the machining precision in the course of thread cutting. In particular, the thread diameter and pitch are controlled by compensation of the axial and radial elastic displacements of the tool, based on timely correction of the transverse and longitudinal supply during the unsteady stage of the process. Compensation of the machining errors improves the dimensional precision of the thread and decreases the systematic errors and spread in the thread dimensions.

42 ENGINEERING↗

Precision Polarized SIDIS Experiments in Hall-A at 12 GeV Jlab

Single (SSA) and double spin asymmetries (DSA) in semi-inclusive DIS reactions using polarized nucleon targets provide a powerful method to probe transverse momentum dependent parton distribution functions (TMDs). The Jefferson Lab 12 GeV upgrade will provide a unique opportunity to perform such precision measurements and to map out these multi-dimensional PDFs. Future plans for performing these measurements in Hall-A using the Solenoidal Large Intensity Device (SoLID) and polarized proton and 3He (neutron) targets are discussed. The high luminosities from these targets and the large acceptance of the SoLID spectrometer will allow for a 4-dimensional (x, Q^2, z, P_T ) mapping of SSA and DSA. The full azimuthal angular coverage is necessary to untangle various angular moments and thereby reduce the systematic uncertainties. These experiments will provide the most precise data to extract transversity (h1), Sivers (f_1T) and Worm-gear (g_1T and h_1L) distributions of u and d-quarks and provide comprehensive information on the correlation between quark angular momentum and the nucleon&#x27;s spin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards verifiable cancer digital twins: tissue level modeling protocol for precision medicine

Cancer exhibits substantial heterogeneity, manifesting as distinct morphological and molecular variations across tumors, which frequently undermines the efficacy of conventional oncological treatments. Developments in multiomics and sequencing technologies have paved the way for unraveling this heterogeneity. Nevertheless, the complexity of the data gathered from these methods cannot be fully interpreted through multimodal data analysis alone. Mathematical modeling plays a crucial role in delineating the underlying mechanisms to explain sources of heterogeneity using patient-specific data. Intra-tumoral diversity necessitates the development of precision oncology therapies utilizing multiphysics, multiscale mathematical models for cancer. This review discusses recent advancements in computational methodologies for precision oncology, highlighting the potential of cancer digital twins to enhance patient-specific decision-making in clinical settings. We review computational efforts in building patient-informed cellular and tissue-level models for cancer and propose a computational framework that utilizes agent-based modeling as an effective conduit to integrate cancer systems models that encode signaling at the cellular scale with digital twin models that predict tissue-level response in a tumor microenvironment customized to patient information. Furthermore, we discuss machine learning approaches to building surrogates for these complex mathematical models. These surrogates can potentially be used to conduct sensitivity analysis, verification, validation, and uncertainty quantification, which is especially important for tumor studies due to their dynamic nature.

60 APPLIED LIFE SCIENCES↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Comprehensive Assessments of RNA-seq by the SEQC Consortium: FDA-Led Efforts Advance Precision Medicine

Studies on gene expression in response to therapy have led to the discovery of pharmacogenomics biomarkers and advances in precision medicine. Whole transcriptome sequencing (RNA-seq) is an emerging tool for profiling gene expression and has received wide adoption in the biomedical research community. However, its value in regulatory decision making requires rigorous assessment and consensus between various stakeholders, including the research community, regulatory agencies, and industry. The FDA-led SEquencing Quality Control (SEQC) consortium has made considerable progress in this direction, and is the subject of this review. Specifically, three RNA-seq platforms (Illumina HiSeq, Life Technologies SOLiD, and Roche 454) were extensively evaluated at multiple sites to assess cross-site and cross-platform reproducibility. The results demonstrated that relative gene expression measurements were consistently comparable across labs and platforms, but not so for the measurement of absolute expression levels. As part of the quality evaluation several studies were included to evaluate the utility of RNA-seq in clinical settings and safety assessment. The neuroblastoma study profiled tumor samples from 498 pediatric neuroblastoma patients by both microarray and RNA-seq. RNA-seq offers more utilities than microarray in determining the transcriptomic characteristics of cancer. However, RNA-seq and microarray-based models were comparable in clinical endpoint prediction, even when including additional features unique to RNA-seq beyond gene expression. The toxicogenomics study compared microarray and RNA-seq profiles of the liver samples from rats exposed to 27 different chemicals representing multiple toxicity modes of action. Cross-platform concordance was dependent on chemical treatment and transcript abundance. Though both RNA-seq and microarray are suitable for developing gene expression based predictive models with comparable prediction performance, RNA-seq offers advantages over microarray in profiling genes with low expression. The rat BodyMap study provided a comprehensive rat transcriptomic body map by performing RNA-Seq on 320 samples from 11 organs in either sex of juvenile, adolescent, adult and aged Fischer 344 rats. Lastly, the transferability study demonstrated that signature genes of predictive models are reciprocally transferable between microarray and RNA-seq data for model development using a comprehensive approach with two large clinical data sets. This result suggests continued usefulness of legacy microarray data in the coming RNA-seq era. In conclusion, the SEQC project enhances our understanding of RNA-seq and provides valuable guidelines for RNA-seq based clinical application and safety evaluation to advance precision medicine.

59 BASIC BIOLOGICAL SCIENCES↗

Improving the Precision of First-Principles Calculation of Parton Physics from Lattice Quantum Chromodynamics

Large momentum effective theory (LaMET) provides a general framework for computing the multi-dimensional partonic structure of the proton from first principles using lattice quantum chromodynamics (QCD). In this effective field theory approach, LaMET predicts parton distributions through a power expansion and perturbative matching of a class of Euclidean observables—quasi-distributions—evaluated at large proton momenta. Recent advances in lattice renormalization, such as the hybrid scheme with leading renormalon resummation, together with improved matching kernel that incorporates higher-loop corrections and resummations, have enhanced both the perturbative and power accuracy of LaMET, enabling a reliable quantification of theoretical uncertainties. Moreover, the Coulomb-gauge correlator approach further simplifies lattice analyses and improves the precision of transverse-momentum-dependent structures, particularly in the non-perturbative region. State-of-the-art LaMET calculations have already yielded certain parton observables with important phenomenological impact. In addition, the recently proposed kinematically enhanced lattice interpolation operators promise access to unprecedented proton momenta with greatly improved signal-to-noise ratios, which will extend the range of LaMET prediction and further suppress the power corrections. The remaining challenges, such as controlling excited-state contamination in lattice matrix elements and extracting gluonic distributions, are expected to benefit from emerging lattice techniques for ground-state isolation and noise reduction. Thus, lattice QCD studies of parton physics have entered an exciting stage of precision control and systematic improvement, which will have a broader impact for nuclear and particle experiments.

Zhao, Yong [Argonne National Laboratory (ANL), Arg↗