Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Computed Tomography (CT) has advanced considerably since being responsible for such dramatic advances in diagnostics within the medical field. It has become a major tool in non destructive evaluation (NDE), and is used in many fields as diverse as coal-mining to metal solidification to examination of rock cores. A review of industrial applications has been written by Dennis. It is only recently that the technique has been seriously used to determine composition through precise measurement of density. While such applications are restricted to cases when there is no ambiguity in the relationship of composition to density. Thus alloy solid solutions lend themselves to compositional analysis provided there is a large change in density with composition. The technique is most useful when rapid non-destructive evaluation is needed. Such cases will occur with samples returning from the International Space Station (ISS) when knowledge of the results could affect future strategies for processing of on-board samples. Experiments from those Principal Investigators (PI) that are most likely to benefit from early CT scanning are discussed. With a dearth of samples, the major emphasis in the first part of this project has been on preparing suitable standards, optimizing the CT technique for these applications, and using the CT system to determine density variations with temperature. An interesting application of CT has been in the examination of meteorites, which can be classified as space-grown materials and will certainly have solidified in a low gravity environment.

Gillies, Donald C.↗

Magnesium Sulfate as a Key Mineral for the Detection of Organic Molecules on Mars Using Pyrolysis

Pyrolysis of soil or rock samples is the preferred preparation technique used on Mars to search for organic molecules up today. During pyrolysis, oxichlorines present in the soil of Mars release oxidant species that alter the organic molecules potentially contained in the samples collected by the space probes.This process can explain the difficulty experienced by in situ exploration probes to detect organic materials in Mars soil samples until recently. Within a few months, the Curiosity rover should reach and analyze for the first time soils rich in sulfates which could induce a different behavior of the organics during the pyrolysis compared with the types of soils analyzed up today. For this reason, we systematically studied the pyrolysis of organic molecules trapped in magnesium sulfate, in the presence or absence of calcium perchlorate. Our results show that organics trapped in magnesium sulfate can undergo some oxidation and sulfuration during the pyrolysis. But these sulfates are also shown to protect organics trapped inside the crystal lattice and/or present in fluid inclusions from the oxidation induced by the decomposition of calcium perchlorate and probably other oxychlorine phases currently detected on Mars. Trapped organics may also be protected from degradation processes induced by other minerals present in the sample, at least until these organics are released from the pyrolyzed sulfate mineral (700C in our experiment). Hence, we suggest magnesium sulfate as one of the minerals to target in priority for the search of organic molecules by the Curiosity and ExoMars 2018 rovers.

Francois, P.↗

An investigation of some mechanical and thermal properties of lunar simulant materials heated at 2.45 GHz

Lunar simulant material was fabricated to simulate Apollo 11, Apollo 15, and Apollo 16 soils. The approximate compositions which these soils simulate are given. Samples of each soil simulate were fabricated into right circular cylinders, placed into a microwave reaction cavity, and heated using 2.45 GHz radiation to a particular processing temperature at which it was held for a prescribed length of time. Examples are given of two microwave heating programs for these simulant samples. Upon completion of thermal processing, each sample had its top and bottom surfaces polished. A technique was employed which looks at hardness data to determine the fracture toughness of a material and then relates this to thermal shock resistance. Some advantages of this technique are its low cost for analysis and thermal shock resistance as a function of initial sample orientation in the microwave field can be determined. Samples were prepared for testing and results are expected. At the same time, other samples are currently being investigated using scanning electron microscopy to determine their microstructures.

Meek, T. T.↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Process air quality data

Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

Butler, C. M.↗

Evaluation of Seismic Artificial Intelligence with Uncertainty

Artificial intelligence has transformed the seismic community with deep learning models (DLMs) that are trained to complete specific tasks within workflows. However, there is still a lack of robust evaluation frameworks for evaluating and comparing DLMs. Here, we address this gap by designing an evaluation framework that jointly incorporates two crucial aspects: performance uncertainty and learning efficiency. To target these aspects, we meticulously construct the training, validation, and test splits using a clustering method tailored to seismic data and enact an expansive training design to segregate performance uncertainty arising from stochastic training processes and random data sampling. The framework’s ability to guard against misleading declarations of model superiority is demonstrated through the evaluation of PhaseNet (Zhu and Beroza, 2018), a popular seismic phase picking DLM, under three training approaches. Our framework helps practitioners choose the best model for their problem and set performance expectations by explicitly analyzing model performance with uncertainty at varying budgets of training data.

58 GEOSCIENCES↗

Detection of Part Porosity in Additive Manufacturing Using Machining

Monitoring of part porosity in additive manufacturing is critical for part qualification and process parameter development. This article describes the monitoring of porosity in additive manufacturing using machining. Grade 91 steel samples with different levels of porosity were additively manufactured using a laser blown-powder process. The samples were machined, and the tool position and cutting power were monitored using the machine controller and an external power transducer, respectively. Results show that the power transducer is sensitive to machining porosities. A novel approach using the standard deviation of cutting power was developed to determine the location of porosities along the length of the machining pass. Test cuts were completed at different machining process parameters. Results showed that the probability of detection was one for pore volume greater than 0.3 mm 3 at different machining parameters. In conclusion, although the detection of porosity using machining is a destructive method for evaluation, it offers a low-cost and fast approach for monitoring porosity in additive manufacturing.

36 MATERIALS SCIENCE↗

Assessing the Ability of Instantaneous Aircraft and Sonde Measurements to Characterize Climatological Means and Long-Term Trends in Tropospheric Composition

Over four decades of measurements exist that sample the 3-D composition of reactive trace gases in the troposphere from approximately weekly ozone sondes, instrumentation on civil aircraft, and individual comprehensive aircraft field campaigns. An obstacle to using these data to evaluate coupled chemistry-climate models (CCMs)the models used to project future changes in atmospheric composition and climateis that exact space-time matching between model fields and observations cannot be done, as CCMs generate their own meteorology. Evaluation typically involves averaging over large spatiotemporal regions, which may not reflect a true average due to limited or biased sampling. This averaging approach generally loses information regarding specific processes. Here we aim to identify where discrete sampling may be indicative of long-term mean conditions, using the GEOS-Chem global chemical-transport model (CTM) driven by the MERRA reanalysis to reflect historical meteorology from 2003 to 2012 at 2o by 2.5o resolution. The model has been sampled at the time and location of every ozone sonde profile available from the Would Ozone and Ultraviolet Radiation Data Centre (WOUDC), along the flight tracks of the IAGOSMOZAICCARABIC civil aircraft campaigns, as well as those from over 20 individual field campaigns performed by NASA, NOAA, DOE, NSF, NERC (UK), and DLR (Germany) during the simulation period. Focusing on ozone, carbon monoxide and reactive nitrogen species, we assess where aggregates of the in situ data are representative of the decadal mean vertical, spatial and temporal distributions that would be appropriate for evaluating CCMs. Next, we identically sample a series of parallel sensitivity simulations in which individual emission sources (e.g., lightning, biogenic VOCs, wildfires, US anthropogenic) have been removed one by one, to assess where and when the aggregated observations may offer constraints on these processes within CCMs. Lastly, we show results of an additional 31-year simulation from 1980-2010 of GEOS-Chem driven by the MACCity emissions inventory and MERRA reanalysis at 4o by 5o. We sample the model at every WOUDC sonde and flight track from MOZAIC and NASA field campaigns to evaluate which aggregate observations are statistically reflective of long-term trends over the period.

Atmospheric composition↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Machine learning models of intermittent operation of RO wellhead water treatment for salinity reduction and nitrate removal

Machine learning models were developed for intermittent multi-mode operation of a wellhead reverse osmosis water purification and desalination system to predict salt passage, nitrate passage, and permeate flux. The models, based on long short-term memory (LSTM) recurrent neural network (RNN) architecture, included an attention mechanism to increase model performance in proximity of the regulatory limit for nitrate. Training and testing of the models for the Startup, Production, Shutdown and Flushing operational modes were based on operational data (consisting of 22 process variables per data sample) acquired every 2–5 s over a six-month period. The significant sets of model input attributes for the different operational modes were assessed via Spearman ranking correlation, Self-Organizing Map (SOM) analysis and feed forward feature selection (FFFS). Although the variability of nitrate passage, salt passage and permeate flux was significant over the four operational modes, prediction performance for the three outcomes were with R2 and Average Absolute Relative Error (AARE) of 0.78–0.95 and 2.96–6.16 %, respectively. Model updates post membrane elements replacement demonstrated similar levels of prediction accuracy. The study results suggest that there is merit in exploring the utility of multi-mode models for sensor fault detection, data imputation, and for potential use in model-predictive control.

Intermittent RO operation↗

Polariton spectra under the collective coupling regime. II. 2D non-linear spectra

In our previous work [Mondal et al., J. Chem. Phys. 162, 014114 (2025)], we developed several efficient computational approaches to simulate exciton–polariton dynamics described by the Holstein–Tavis–Cummings (HTC) Hamiltonian under the collective coupling regime. Here, we incorporated these strategies into the previously developed Lindblad-partially linearized density matrix (⁠$\mathscr{L}$-PLDM) approach for simulating 2D electronic spectroscopy (2DES) of exciton–polariton under the collective coupling regime. In particular, we apply the efficient quantum dynamics propagation scheme developed in Paper I to both the forward and the backward propagations in the PLDM and develop an efficient importance sampling scheme and graphics processing unit vectorization scheme that allow us to reduce the computational costs from $\mathscr{O}$($\mathscr{K}$ 2 )$\mathscr{O}$(T 3 ) to $\mathscr{O}$($\mathscr{K}$)$\mathscr{O}$(T 0 ) for the 2DES simulation, where $\mathscr{K}$ is the number of states and T is the number of time steps of propagation. As a result, we further simulated the 2DES for an HTC Hamiltonian under the collective coupling regime and analyzed the signal from both rephasing and non-rephasing contributions of the ground state bleaching, excited state emission, and stimulated emission pathways.

2D non-linear spectra↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Sharp detection of low-dimensional structure in probability measures via dimensional logarithmic Sobolev inequalities

Identifying low-dimensional structure in high-dimensional probability measures is an essential pre-processing step for efficient sampling. To identify this structure, we approximate the target measure as a perturbation of an arbitrary reference measure along a few directions in $\mathbb{R}^{d}$. These directions are determined by minimizing an upper bound on the Kullback–Leibler (KL) divergence between the target and its approximation. Our contribution improves upon previous works by leveraging dimensional logarithmic Sobolev inequalities to refine the bound on the KL divergence. These inequalities lead to a uniformly tighter bound on the KL divergence, thereby enhancing the identification of the most significant perturbation directions. In particular, when the target and reference are both Gaussian, minimizing the resulting bound is equivalent to minimizing the KL divergence. We further demonstrate the applicability of this analysis to the squared Hellinger distance, where analogous reasoning shows that the dimensional Poincaré inequality offers improved bounds.

Bayesian inference↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗

Datum: A Scientific Metadata Catalog

The data catalog market is currently flooded with a myriad of different products, but none serve the scientific community well. There are cloud-native tools like Databricks, Snowflake,to on-premise solutions like Collibra and Datahub. The common failing of all these tools however, is their inability to serve the scientific data community directly. Most catalogs are targeted towards financial, health, or user data - not sensor or scientific domain data. They also prioritize integrations that often don’t exist or are just starting to be used in the scientific realm - all while ignoring common scientific tools and file types. Datum is a catalog which targets the scientific data directly, including the tools and networks in which those tools are used. We work with the producers and consumers of the data where they are, targeting cloud and on-premise with a focus on classified networks. Datum is an Erlang/Elixir application. Technical Features Note: The features listed below are still under development and may change, slightly, upon final delivery of the product. File Formats - Datum has the ability to read additional metadata and provides processing pipelines for the following file formats: Plain Text, PDF, LaTeX, HTML, Open Document Format (.odt), XML, CSV/TSV (and other standard delimiters), OpenDocument Database and Spreadsheets, Geo-Referenced TIFF, Common Data Format, HDF/HDF5, LabView TDMS, Excel, DeltaTables, Parquet, Apache Iceberg, Apache Hudi and many others. Metadata Collection - Scanners for the local and networked file systems and cloud storage providers. Network integration with common databases such as MSSQL and MySQL. User Plugin System - Users are able to provide either file processing, metadata extraction, or sampling plugins in the programming language of their choice. Authentication/Authorization -: OIDC integration, SCIM provisioning and EntraID integration out of the box. Full user and group management system with a “least privilege” operating mode. Governance - Customizable data governance platform; dictate and enforce required metadata, enforce data embargos, and enforce user agreements and NDAs before data access. Ability to create health checks on data, rejecting abandoned or poorly curated data and automatically removing it from the search index. Ability for users to submit corrections. Search - Semantic search is a first class citizen. No licenses to expensive, external software required. Integrated use of vectors and vector-based search allows for AI agent integration at all levels of operation. Metadata Model - Display and control data’s lineage and connections to other data and data directories. Data is modeled after a filesystem - an organization instantly recognizable and navigable by most any user. CLI and SDK - Ships with a Command Line Interface (CLI) tool and with a fully-featured Python SDK. This allows for rapid and programmatic use of Datum by every level of user. Minimal Infrastructure - Datum ships as a single executable file and can be run on any operating system and most CPU architectures. Datum has no reliance on external databases, search indexing tools, or other outside services - and it runs equally well on edge computing devices, cloud services, or in a clustered HPC environment.

darrington, john↗

Control System for RF OPM

SAND2025-01910O This software built in LabVIEW FPGA provides experimental control of the RF OPM prototype via a reconfigurable NI I/O card. It samples the analog input, processes it on the FPGA in real time, and generates control and feedback outputs to control and optimize the operation of the device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bainbridge, Jonathan↗

April 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the April 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The April 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

October 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the October 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). At 64 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The October 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the sample collection at SWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗