Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Determination of total chlorine and bromine in solid wastes by sintering and inductively coupled plasma-sector field mass spectrometry

A sample preparation method based on sintering, followed by analysis by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) for the simultaneous determination of chloride and bromide in diverse and mixed solid wastes, has been evaluated. Samples and reference materials of known composition were mixed with a sintering agent containing Na{sub 2}CO{sub 3} and ZnO and placed in an oven at 560 deg. C for 1 h. After cooling, the residues were leached with water prior to a cation-exchange assisted clean-up. Alternatively, a simple microwave-assisted digestion using only nitric acid was applied for comparison. Thereafter the samples were prepared for quantitative analysis by ICP-SFMS. The sintering method was evaluated by analysis of certified reference materials (CRMs) and by comparison with US EPA Method 5050 and ion chromatography with good agreement. Median RSDs for the sintering method were determined to 10% for both chlorine and bromine, and median recovery to 96% and 97%, respectively. Limits of detection (LODs) were 200 mg/kg for chlorine and 20 mg/kg for bromine. It was concluded that the sintering method is suitable for chlorine and bromine determination in several matrices like sewage sludge, plastics, and edible waste, as well as for waste mixtures. The sintering method was also applied for determination of other elements present in anionic forms, such as sulfur, arsenic, selenium and iodine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An investigation of the long-range and local structure of sub-stoichiometric zirconium carbide sintered at different temperatures

ZrC 1-x (sub-stoichiometric zirconium carbide), a group IV transition metal carbide, is being considered for various high temperature applications. Departure from stoichiometry changes the thermo-physical response of the material. Reported thermo-physical properties exhibit, in some cases, a degree of scatter with one likely contributor to this being the uncertainty in the C/Zr ratio of the samples produced. Conventional, methods for assigning C/Zr to samples are determined either by nominal stochiometric ratios or combustion carbon analysis. In this study, a range of stoichiometries of hot-pressed ZrC 1-x were examined by SEM, XRD, Raman spectroscopy and static 13 C NMR spectroscopy and used as a basis to correct the C/Zr. Graphite, amorphous, and ZrC 1-x carbon signatures are observed in the 13 C NMR spectra of samples and are determined to vary in intensity with sintering temperature and stoichiometry. In this study a method is outlined to quantify the stoichiometry of ZrC 1-x and free carbon phases, providing an improvement over the sole use and reliance of widely adopted bulk carbon combustion analysis. We report significantly lower C/Zr values determined by 13 C NMR analysis compared with carbon analyser and nominal methods. Furthermore, the location of carbon disassociated from the ZrC 1-x structure is analysed using SEM and Raman spectroscopy.

36 MATERIALS SCIENCE↗

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser. Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

You are not always what we think you eat. Selective assimilation across multiple whole-stream isotopic tracer studies

Analyses of 21 15 N stable isotope tracer experiments, designed to examine food web dynamics in streams around the world, indicated that the isotopic composition of food resources assimilated by primary consumers (mostly invertebrates) poorly reflected the presumed food sources. Modeling indicated that consumers assimilated only 33–50% of the N available in sampled food sources such as decomposing leaves, epilithon, and fine particulate detritus over feeding periods of weeks or more. Thus, common methods of sampling food sources consumed by animals in streams do not sufficiently reflect the pool of N they assimilate. Lastly, Isotope tracer studies, combined with modeling and food separation techniques, can improve estimation of N pools in food sources that are assimilated by consumers.

07 ISOTOPE AND RADIATION SOURCES↗

System and method for measuring particles in a sample stream of a flow cytometer using a low power laser source

A system and method for analyzing a particle in a sample stream of a flow cytometer or the like. The system has a light source, such as a laser pointer module, for generating a low powered light beam and a fluidics apparatus which is configured to transport particles in the sample stream at substantially low velocity through the light beam for interrogation. Detectors, such as photomultiplier tubes, are configured to detect optical signals generated in response to the light beam impinging the particles. Signal conditioning circuitry is connected to each of the detectors to condition each detector output into electronic signals for processing and is designed to have a limited frequency response to filter high frequency noise from the detector output signals.

47 OTHER INSTRUMENTATION↗

System and method for measuring particles in a sample stream of a flow cytometer using low-power laser source

A system and method for analyzing a particle in a sample stream of a flow cytometer or the like. The system has a light source, such as a laser pointer module, for generating a low powered light beam and a fluidics apparatus which is configured to transport particles in the sample stream at substantially low velocity through the light beam for interrogation. Detectors, such as photomultiplier tubes, are configured to detect optical signals generated in response to the light beam impinging the particles. Signal conditioning circuitry is connected to each of the detectors to condition each detector output into electronic signals for processing and is designed to have a limited frequency response to filter high frequency noise from the detector output signals.

47 OTHER INSTRUMENTATION↗

System and method for measuring particles in a sample stream of a flow cytometer using low-power laser source

A system and method for analyzing a particle in a sample stream of a flow cytometer or the like. The system has a light source, such as a laser pointer module, for generating a low powered light beam and a fluidics apparatus which is configured to transport particles in the sample stream at substantially low velocity through the light beam for interrogation. Detectors, such as photomultiplier tubes, are configured to detect optical signals generated in response to the light beam impinging the particles. Signal conditioning circuitry is connected to each of the detectors to condition each detector output into electronic signals for processing and is designed to have a limited frequency response to filter high frequency noise from the detector output signals.

Graves, Steven W.↗

Total Recoverable Aluminum: Not Totally Relevant for Water Quality Standards

Abstract A large water quality data set, representing more than 100 surface-water locations sampled from 2007 to 2017 in the Los Alamos area of New Mexico, USA's Pajarito Plateau, was assembled to evaluate Al concentrations in unfiltered and filtered samples. Aluminum concentrations often exceeded United States Environmental Protection Agency (USEPA) and New Mexico ambient water quality criteria (AWQC), regardless of filter size and sample location. However, AWQC are based on laboratory toxicity studies using soluble Al salts and do not reflect natural conditions in Pajarito Plateau surface waters. The plateau is predominately covered by glassy and recrystallized volcanic ashes (e.g., Bandelier Tuff) containing colloidal to sand-sized aluminosilicates. Samples from natural background drainages and areas downstream of developed regions exhibited similar Al concentrations, suggesting that AWQC exceedances are caused by naturally elevated Al concentrations. Solubility calculations indicated that most samples were oversaturated with respect to amorphous Al(OH)3(s). Therefore, AWQC exceedances are likely artifacts of the “total recoverable” sample preparation, which includes acidification and partial digestion, thereby liberating nonbioavailable Al from aluminosilicates. Accordingly, Al concentrations were strongly associated with suspended sediment concentrations (SSCs), implying that aluminosilicates in suspended sediment contributed to AWQC exceedances and Al oversaturation. Solid-phase particle characterization, using X-ray diffraction (XRD) and scanning electron microscopy with electron dispersive spectroscopy (SEM/EDS) did not identify potentially bioavailable amorphous Al(OH)3(s) in any sample tested. Thus, current sample collection and analysis protocols should not be used to evaluate attainment of Al AWQC on the Pajarito Plateau or locations where aluminosilicates are substantial contributors to total recoverable Al. A sample preparation method (e.g., pH 4 extraction) capable of differentiating nonbioavailable and bioavailable forms of Al is recommended. Otherwise, current New Mexico and USEPA sample preparation approaches will continue to generate artifactual AWQC exceedances in surface waters that contain aluminosilicates. Integr Environ Assess Manag 2019;00:1–14. © 2019 SETAC

Ryan, Adam C.↗

Substitutional effect of Ni on different properties of ZnO nanocrystals

Samples of pure and Ni doped ZnO nanocrystals with nominal compositions (x = 0.00, 0.03, 0.05) were successfully synthesized by Co-precipitation method. These samples were characterized by X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectrometer (FTIR). From XRD patterns it is confirmed that all samples have hexagonal (wurtzite) structure without formation any secondary phases. Atomic packing fraction (APF) and c/a ratio were calculated using XRD data. The lattice parameters of samples decrease with increasing Ni concentration. The average crystalline size was calculated by Scherrer’s formula and it is found that the average crystalline size is in the range 43-56 nm. The SEM micrographs of samples show the agglomeration of nanocrystals. Chemical species of the samples were detected using FTIR spectra. It confirms the formation of ZnO with the stretching vibrational mode around at 512 cm{sup −1}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tailored Fano resonance and localized electromagnetic field enhancement in Ag gratings

Metallic gratings can support Fano resonances when illuminated with EM radiation, and their characteristic reflectivity versus incident angle lineshape can be greatly affected by the surrounding dielectric environment and the grating geometry. By using conformal oblique incidence thin film deposition onto an optical grating substrate, it is possible to increase the grating amplitude due to shadowing effects, thereby enabling tailoring of the damping processes and electromagnetic field couplings of the Fano resonances, hence optimizing the associated localized electric field intensity. To investigate these effects we compare the optical reflectivity under resonance excitation in samples prepared by oblique angle deposition (OAD) and under normal deposition (ND) onto the same patterned surfaces. We observe that by applying OAD method, the sample exhibits a deeper and narrower reflectivity dip at resonance than that obtained under ND. This can be explained in terms of a lower damping of Fano resonance on obliquely deposited sample and leads to a stronger localized electric field. This approach opens a fabrication path for applications where tailoring the electromagnetic field induced by Fano resonance can improve the figure of merit of specific device characteristics, e.g. quantum efficiency (QE) in grating-based metallic photocathodes.

36 MATERIALS SCIENCE↗

Isopiestic Measurements of Water Adsorption on Uranium Bearing Solids - 1900w

The research focus was to investigate the stability of the multicomponent uranium-bearing precipitates mimicking those created in sediments as a result of alkaline ammonia gas treatment in the vadose zone. Gravimetric measurements of moisture uptake on uranium-bearing precipitates as a function of increasing relative humidity can provide reasonable estimates of the deliquescence point of solid phases or its components. Water moisture uptake by uranium-bearing precipitates as a function of increasing relative humidity was measured at 25 deg. C via the isopiestic method. The conditions for each isotherm were calculated by a division of the amount of adsorbed moisture by the amount of dry precipitate samples. This method can provide estimates of water quantity retained within precipitates conducted in the range of water activities. The desorption portion of the isotherm was obtained by progressively decreasing the water activity or relative pressure in the isopiestic chamber while monitoring the equilibrium amount of moisture sorbed at each relative pressure. The amount of water adsorbed by multicomponent precipitates at a{sub w} = 0.67 ranged between 0.63 and 0.77 g water/g precipitate. Higher water activities or relative humidity values eventually lead to the deliquescence of the solid or its components and the formation of a liquid phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SNAPSHOT METALLICITY ESTIMATE OF RESOLVED STELLAR SYSTEMS THROUGH LICK Fe5270 DIAGNOSTIC

We outline a new method to derive a 'snapshot' metallicity estimate of stellar systems (providing one resolves at least the brightest part of the color-magnitude diagram) on the basis of low-resolution (i.e., 6-8 A FWHM) spectroscopy of a small stellar sample. Our method relies on the Fe5270 Lick index measurements and takes advantage of the special behavior of this spectral feature that reaches its maximum strength among the ubiquitous component of K-type giants. This makes the Fe5270{sub max} estimate a robust and model-independent tracer of cluster [Fe/H], being particularly insensitive to the age of the stellar population. A comparison of the Fe5270{sub max} distribution derived from globular and open clusters, as well as from the field giant population in the Galaxy disk, confirms a tight correlation of the index maximum versus cluster [Fe/H] over the entire metallicity range for a stellar population with [Fe/H] approx>-2.0. Relying on a theoretical calibration of the feature, we trust to infer effectively cluster metallicity within a typical uncertainty of 0.1-0.2 dex, depending on red giant branch (RGB) luminosity sampling of the observations. A handful of stars (5-10 objects) is required for the method to be applied, with low-metallicity stellar populations more easily managed, being Fe5270{sub max} located within the few brightest RGB stars of the system. In any case, we show that even the observation of a coarse stellar set would allow us to place a confident lower limit on cluster metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

High-density grids for efficient data collection from multiple crystals

Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassette or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into the Blu-Ice / DCSS experimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of scat detection methods for a social ungulate, the wild pig, and experimental evaluation of factors affecting detection of scat

Collection of scat samples is common in wildlife research, particularly for genetic capture-mark-recapture applications. Due to high degradation rates of genetic material in scat, large numbers of samples must be collected to generate robust estimates. Optimization of sampling approaches to account for taxa-specific patterns of scat deposition is, therefore, necessary to ensure sufficient sample collection. While scat collection methods have been widely studied in carnivores, research to maximize scat collection and noninvasive sampling efficiency for social ungulates is lacking. Further, environmental factors or scat morphology may influence detection of scat by observers. We contrasted performance of novel radial search protocols with existing adaptive cluster sampling protocols to quantify differences in observed amounts of wild pig ( Sus scrofa ) scat. We also evaluated the effects of environmental (percentage of vegetative ground cover and occurrence of rain immediately prior to sampling) and scat characteristics (fecal pellet size and number) on the detectability of scat by observers. We found that 15- and 20-m radial search protocols resulted in greater numbers of scats encountered than the previously used adaptive cluster sampling approach across habitat types, and that fecal pellet size, number of fecal pellets, percent vegetative ground cover, and recent rain events were significant predictors of scat detection. Our results suggest that use of a fixed-width radial search protocol may increase the number of scats detected for wild pigs, or other social ungulates, allowing more robust estimation of population metrics using noninvasive genetic sampling methods. Further, as fecal pellet size affected scat detection, juvenile or smaller-sized animals may be less detectable than adult or large animals, which could introduce bias into abundance estimates. In conclusion, knowledge of relationships between environmental variables and scat detection may allow researchers to optimize sampling protocols to maximize utility of noninvasive sampling for wild pigs and other social ungulates.

59 BASIC BIOLOGICAL SCIENCES↗

A novel digitization scheme with FPGA-base TDC for beam loss monitors operating at cryogenic temperature

Recycling integrators are common current-to-frequency converting circuits for measurements of low current such as that produced by Fermilab's cryogenic ionization chambers. In typical digitization/readout schemes, a counter is utilized to accumulate the number of pulses generated by the recycling integrator to adequately digitize the total charge. In order to calculate current with reasonable resolution (e.g., 7-8 bits), hundreds of pulses must be accumulated which corresponds to a long sampling period, i.e., a very low sampling rate. In our new scheme, an FPGA-based Time-to-Digital Convertor (TDC) is utilized to measure the time intervals between the pulses output from the recycling integrator. Using this method, a sample point of the current can be made with good resolution (>10 bits) for each pulse. This effectively increases the sampling rates by hundreds of times for the same recycling integrator front-end electronics. This scheme provides a fast response to the beams loss and is potentially suitable for accelerator protection applications. Moreover, the method is also self-zero-suppressed, i.e., it produces more data when the beam loss is high while it produces significantly less data when the beam loss is low.

43 PARTICLE ACCELERATORS↗