Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Effects of zonal flows on ion temperature gradient instability in the scrape-off layer of a field-reversed configuration

Gyrokinetic simulations of long wavelength ion temperature gradient (ITG) turbulence in the scrape-off layer (SOL) of a field-reversed configuration (FRC) find that zonal flows are nonlinearly generated and are the dominant mechanism for the nonlinear saturation of the ITG instability. After the ITG saturation, zonal flows remain undamped and gradually suppress the turbulent transport to a very low level. In the simulations with collisions, collisional damping gradually reduces zonal flow amplitude to a lower level, which allows finite ITG turbulence intensity and ion heat transport in the SOL. The steady state turbulence intensity and ion heat transport are found to be proportional to the collision frequency. Furthermore, this favorable scaling suggests that minimizing collisions (e.g. increasing temperature, reducing impurity content, etc) and preserving toroidal symmetry could improve plasma confinement in the FRC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How does humidity data impact land surface modeling of hydrothermal regimes at a permafrost site in Utqia$\mathrm{\dot{g}}$vik, Alaska?

Humidity is a basic and crucial meteorological indicator commonly measured in several forms, including specific humidity, relative humidity, and absolute humidity. These different forms can be inter-derived based on the saturation vapor pressure (SVP). In past decades, dozens of formulae have been developed to calculate the SVP with respect to, and in equilibrium with, liquid water and solid ice surfaces, but many prior studies use a single function for all temperature ranges, without considering the distinction between over the liquid water and ice surfaces. These different approaches can result in humidity estimates that may impact our understanding of surface-subsurface thermal-hydrological dynamics in cold regions. In this study, we compared the relative humidity (RH) downloaded and calculated from four data sources in Alaska based on five commonly used SVP formulas. These RHs, along with other meteorological indicators, were then used to drive physics-rich land surface models at a permafrost-affected site. Here, we found that higher values of RH (up to 40%) were obtained if the SVP was calculated with the over-ice formulation when air temperatures were below freezing, which could lead to a 30% maximum difference in snow depths. The choice of whether to separately calculate the SVP over an ice surface in winter also produced a significant range (up to 0.2 m) in simulated annual maximum thaw depths. The sensitivity of seasonal thaw depth to the formulation of SVP increases with the rainfall rate and the height of above-ground ponded water, while it diminishes with warmer air temperatures. These results show that RH variations based on the calculation of SVP with or without over-ice calculation meaningfully impact physically-based predictions of snow depth, sublimation, soil temperature, and active layer thickness. Under particular conditions, when severe flooding (inundation) and cool air temperatures are present, care should be taken to evaluate how humidity data is estimated for land surface and earth system modeling.

54 ENVIRONMENTAL SCIENCES↗

Exposing and Reducing Biases of Simulating Mixed-Phase Clouds in the Convection-Permitting E3SM Atmosphere Model: Lessons From an Arctic Cold-Air Outbreak

Mixed-phase clouds modulate the water and energy cycles of high-latitude regions, yet their liquid-ice phase partitioning has long been poorly simulated in climate models. Here, simulations of Arctic mixed-phase clouds by the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM) are assessed against large-eddy simulations, satellite data, and ground-based observations during the Cold-Air Outbreaks in the Marine Boundary Layer Experiment field campaign. SCREAM simulates nearly completely frozen clouds, which is attributed largely to the unreasonably strong Wegener–Bergeron–Findeisen (WBF) process that converts liquid to ice excessively and partly to the early over-abundant ice production at cold temperatures from a temperature-deterministic deposition ice nucleation scheme. Assuming no subgrid variation for the WBF process in the original formulation particularly conflicts with the instantaneous saturation adjustment assumption in the condensation scheme that assumes subgrid variability, leading to exaggerated WBF process rates. A proposed simple physically-based improvement on the treatment of subgrid cloud overlap substantially increases supercooled liquid water content and notably improves cloud-top phase partitioning, aligning better with observations. Improvement of supercooled liquid water content also converges with increasing horizontal resolution. The deposition ice nucleation scheme is found responsible for a falsely-produced ice cloud aloft that is not observed, biasing the simulated cloud radiative effects and top-of-atmosphere radiative fluxes. This study identifies key deficiencies in cloud parameterizations that continue to challenge convection-permitting models.

Geosciences↗

Regulation of Alfvén Eigenmodes by Microturbulence in Fusion Plasmas

Global gyrokinetic simulations of mesoscale reversed shear Alfven eigenmodes (RSAE) excited by energetic particles (EP) in fusion plasmas find that RSAE amplitude and EP transport are much higher than experimental levels at nonlinear saturation, but quickly diminish to very low levels after the saturation when background microturbulence is artificially suppressed. In contrast, in simulations coupling micro-meso scales, the RSAE amplitude and EP transport decrease drastically at the initial saturation but later increases to the experimental levels in the quasi-steady state with bursty dynamics due to regulation by thermal ion temperature gradient (ITG) microturbulence. The quasi-steady state EP transport is larger for a stronger microturbulence. Here, the RSAE amplitude in the quasi-steady state ITG-RSAE turbulence from gyrokinetic simulations, for the first time, agrees very well with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Volatile products in the corrosion of Cr, Mo, Ti and four superalloys exposed to O2 containing H2O and gaseous NaCl

Cooled target collection techniques were used to study the formation of volatile products when samples of Cr, Ti, IN-738, 713C, NASA-TRW VIA and B-1900 were exposed, at elevated temperatures, to oxidizing environments containing H2O(g) and NaCl(g). Samples were heated to 1050 C in one atmosphere of slowly flowing oxygen, saturated with water at 21 C, and containing about 50 ppm NaCl(g). Volatile products were detected for all materials except B-1900 and Ti. High pressure mass spectrometric sampling was used to directly identify volatile products emanating from samples of Cr and IN-738 subject to the above environments.

Fryburg, G. C.↗

The relative humidity of Mars' atmosphere

As a general rule, Mars' atmosphere contains as much water vapor as it can hold on a daily basis; it reaches saturation at night, and the vapor appears to be distributed throughout the lowest several kilometers. Interesting exceptions to this occur when there are temperature inversions in the arctic springtime and during dust-storm activity. As contrasted to the northern hemisphere there appears to be no local source of water in the southern temperate and arctic areas.

Davies, D. W.↗

Theory of droplet. Part 1: Renormalized laws of droplet vaporization in non-dilute sprays

The vaporization of a droplet, interacting with its neighbors in a non-dilute spray environment is examined as well as a vaporization scaling law established on the basis of a recently developed theory of renormalized droplet. The interacting droplet consists of a centrally located droplet and its vapor bubble which is surrounded by a cloud of droplets. The distribution of the droplets and the size of the cloud are characterized by a pair-distribution function. The vaporization of a droplet is retarded by the collective thermal quenching, the vapor concentration accumulated in the outer sphere, and by the limited percolative passages for mass, momentum and energy fluxes. The retardation is scaled by the local collective interaction parameters (group combustion number of renormalized droplet, droplet spacing, renormalization number and local ambient conditions). The numerical results of a selected case study reveal that the vaporization correction factor falls from unity monotonically as the group combustion number increases, and saturation is likely to occur when the group combustion number reaches 35 to 40 with interdroplet spacing of 7.5 diameters and an environment temperature of 500 K. The scaling law suggests that dense sprays can be classified into: (1) a diffusively dense cloud characterized by uniform thermal quenching in the cloud; (2) a stratified dense cloud characterized by a radial stratification in temperature by the differential thermal quenching of the cloud; or (3) a sharply dense cloud marked by fine structure in the quasi-droplet cloud and the corresponding variation in the correction factor due to the variation in the topological structure of the cloud characterized by a pair-distribution function of quasi-droplets.

Chiu, H. H.↗

The January 30, 1989 Arctic polar stratospheric clouds (PSC) event - Evidence for a mechanism of dehydration

In-situ particle measurements made aboard the NASA ER-2 in the Arctic on 890130 (YYMMDD) show Type 1 PSC particles over much of the flight, with instances of embedded Type 2 PSCs. The Type 2 particles were observed at temperatures warmer than the local frost-point temperature of water; extended up to the upper size cutoff of the instrument (about 24-micron diameter); and are shown to contain too large a volume to be primarily NAT. Based on measured vertical temperature profiles, it is concluded that the Type 2 particles observed on this day were formed above the aircraft in a region where saturation with respect to ice was achieved and were sufficiently large to have fallen into the path of the ER-2. Although the amount of material in the particles, expressed as water, is small by comparison to the total (vapor + aerosol) water concentration, the flux of water from the falling particles is of sufficient magnitude, if sustained, to lead to dehydration of the source region. These observations verify the mechanism for dehydration of polar vortex air masses by precipitation of ice particles.

Gandrud, B. W.↗

The effects of oxygen on the evolution of microbial membranes

One prokaryote, Methylococcus capsulatus, synthesizes both hopanoids and sterols and, thus, provides a unique opportunity to study the evolution of membrane function. When M. capsulatus was grown at different temperatures, lipid analysis of the whole cells showed that both sterol and unsaturated fatty acid levels decreased at higher growth temperatures; sterol concentrations were 0.116 micro mole/micro mole phospholipid at 30 C and 0.025 micro mole/mirco mole phospholipid at 45 C, while the saturated to unsaturated fatty acid ratio increased from 0.397 to 1.475. Hopane polyol levels were constant over this range; however, methylation of the A-ring decreased markedly in cells grown at 30 C. These results imply that sterol and hopane molecules are required for enhancement of some specific membrane function, potentially by modulating membrane fluidity.

Jahnke, L. L.↗

Modeling of the near-electrode regions of arcjets. I - Coupling of the flowfield to the non-equilibrium boundary layers

A model for arc attachment at an anode in contact with a flowing thermal plasma is described. Current limitations are identified which arise when the convective transport of ions into the electrical, thermal and hydrodynamic boundary layers is incapable of supplying the loss of ions through three-body recombination in the volume, and catalytic recombination on the electrode surface. It is shown that the anode current where this condition is achieved can be exceeded provided there is a significant Joule heating in the boundary layer. The saturation current (current density above which the anode must emit ions) is found to substantially increase with increasing free stream velocity and anode temperature.

Cappelli, Mark A.↗

Detailed Structure of the Tropical Upper Troposphere and Lower Stratosphere as Revealed by Balloon Sonde Observations of Water Vapor, Ozone, Temperature, and Winds During the NASA TCSP and TC4 Campaigns

We report on balloon sonde measurements of water vapor and ozone using the cryogenic frost point hygrometer and electrochemical concentration cell ozonesondes made at Alajuela, Costa Rica (10.0 N, 84.2 W) during two NASA airborne campaigns: the Tropical Convective Systems and Processes (TCSP) mission in July 2005 and the Tropical Composition, Clouds, and Climate Coupling Experiment (TC4), July - August 2007. In both campaigns we found an upper troposphere that was frequently supersaturated but no evidence that deep convection had reached the tropopause. The balloon sondes were complemented by campaigns of 4 times daily high-resolution radiosondes from mid-June through mid-August in both years. The radiosonde data reveal vertically propagating equatorial waves that caused a large increase in the variability of temperature in the tropical tropopause layer (TTL). These waves episodically produced cold point tropopauses (CPTs) above 18 km, yet in neither campaign was saturation observed above approx 380 K or 17 km. The averages of the water vapor minima below this level were 5.2 ppmv in TCSP and 4.8 ppmv in TC4, and the individual profile minima all lay at or above approx 360 K. The average minima in this 360 C380 K layer provide a better estimate of the effective stratospheric entry value than the average mixing ratio at the CPT. We refer to this upper portion of the TTL as the tropopause saturation layer and consider it to be the locus of the final dehydration of nascent stratospheric air. As such, it is the local equivalent to the tape head of the water vapor tape recorder.

Selkirk, Henry B.↗

Dehydration in the lower Antarctic stratosphere in late winter and spring

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met 0 and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arenas (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

Dehydration in the lower Antarctic stratosphere during late winter and early spring, 1987

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met O and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arens (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

Structural coupling and magnetic tuning in Mn 2– x Co x P magnetocalorics for thermomagnetic power generation

Promising materials for magnetic refrigeration and thermomagnetic power generation often display strong coupling between magnetism and structure. It has been previously proposed that MnCoP exhibits this strong coupling, contributing to its substantial magnetocaloric effect near T C = 578K. Here, we show from temperature-dependent synchrotron x-ray diffraction that MnCoP displays a discontinuity in the thermal expansion at T C , with spontaneous magnetostriction that is positive in the a direction and negative in the b direction, highlighting the anisotropic nature of the magnetostructural coupling. Varying the Mn:Co ratio of Mn 2– x Co x P within the range of 0.6 ≤ x ≤ 1.4 allows the magnetic properties to be tuned. T C decreases as the composition deviates from stoichiometric MnCoP, as does the saturation magnetization. The magnitude of the magnetocaloric effect, |Δ S M |, decreases as well, due to broadening of the magnetic transition. The large reversible change in magnetization Δ M accessible over a small temperature range under moderate magnetic fields makes these materials promising for thermomagnetic power generation from waste heat.

36 MATERIALS SCIENCE↗

Growth and Saturation of the Electron Drift Instability in a Crossed Field Plasma

The linear growth and nonlinear energy transfer of the electron drift instability (EDI) are experimentally measured in the plume of a low-temperature, Hall effect discharge. A frequency-based bispectral analysis technique applied to fast ion density fluctuation measurements shows a growth rate function that is qualitatively similar to predictions from the linear instability dispersion relation, but an order of magnitude smaller. Calculation of the nonlinear transfer function indicates multiple three-wave interactions between high-frequency resonances of the instability in addition to an inverse energy cascade toward lower-frequency modes. Furthermore, these results are discussed in the context of recent theoretical, numerical, and experimental efforts on the EDI in Hall effect discharges and how the EDI may impact anomalous cross field transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal Study 2022-2024: Sensor-Based Time Series of Surface Water Temperature, Specific Conductance, Total Dissolved Solids, Turbidity, Chlorophyll A, and Dissolved Oxygen from across Multiple Watersheds in the Yakima River Basin in Washington, USA

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides periodic (bi-weekly or monthly) in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata collected at six sites across the Yakima River Basin in Washington, USA. Sample and sensor data from previous years (2021-2022) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054, respectively. Related sample data from 2022-2024 are available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2562910. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions This dataset contains a folder of environmental context photographs and videos and (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) field protocols; (6) international generic sample number (IGSN) mapping file; (7) handheld sensor data; and (8) two sensor subfolders. Each sensor subfolder (BarotrollAtm and MantaRiverData) contains a subfolder containing sensor time series data and plots. The BarotrollAtm Data subfolder contains In Situ Rugged BaroTROLL sensor pressure and air temperature data. The MantaRiverData subfolder contains Eureka Manta+ 35B multisonde temperature, specific conductance, and chlorophyll A. All files are .csv, .pdf, .jpg, .jpeg, .mp4, .png, or .mov.

54 ENVIRONMENTAL SCIENCES↗

The role of microstructural evolution during spark plasma sintering on the soft magnetic and electronic properties of a CoFe–Al2O3 soft magnetic composite

Abstract For transformers and inductors to meet the world’s growing demand for electrical power, more efficient soft magnetic materials with high saturation magnetic polarization and high electrical resistivity are needed. This work aimed at the development of a soft magnetic composite synthesized via spark plasma sintering with both high saturation magnetic polarization and high electrical resistivity for efficient soft magnetic cores. CoFe powder particles coated with an insulating layer of Al 2 O 3 were used as feedstock material to improve the electrical resistivity while retaining high saturation magnetic polarization. By maintaining a continuous non-magnetic Al 2 O 3 phase throughout the material, both a high saturation magnetic polarization, above 1.5 T, and high electrical resistivity, above 100 μΩ·m, were achieved. Through microstructural characterization of samples consolidated at various temperatures, the role of microstructural evolution on the magnetic and electronic properties of the composite was elucidated. Upon consolidation at relatively high temperature, the CoFe was to found plastically deform and flow into the Al 2 O 3 phase at the particle boundaries and this phenomenon was attributed to low resistivity in the composite. In contrast, at lower consolidation temperatures, perforation of the Al 2 O 3 phase was not observed and a high electrical resistivity was achieved, while maintaining a high magnetic polarization, ideal for more efficient soft magnetic materials for transformers and inductors.

36 MATERIALS SCIENCE↗

Thermodynamic modeling of MDEA(aq)-NH 3 (aq)-K 2 CO 3 (aq)-CO 2 (aq) using the Extended UNIQUAC model

Here, the development of advanced processes for carbon dioxide capture requires reliable thermodynamic models to ensure accurate process design. This work presents an optimized parameter set of the Extended UNIQUAC model for advanced mixed solvent solutions containing CO 2 -MDEA-NH 3 -K 2 CO 3 in water. The model was parameterized using vapor–liquid equilibrium, pure component saturation pressure, excess enthalpy, heat of absorption, molar heat capacity, apparent molar heat capacity, and solid–liquid equilibrium. These thermal and equilibrium properties cover temperatures between 253.6 K to 600 K and pressures up to 75.6 bar. The current model represents an extension of previous versions that were suitable for modeling aqueous NH 3 and K 2 CO 3 solutions. This parametrization accounts for molecular interactions between MDEA and these two components, which allows for the design of advanced capture processes. This paper demonstrates that the new model parameters are valid within the range of operational conditions typically found in CO 2 capture processes.

42 ENGINEERING↗