Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

The implications of fast charge in lithium ion battery performance and life: cell vs. pack

This study investigates the effect of 50-kW (about 2C) direct current fast charging on a full-size battery electric vehicle's battery pack in comparison to a pack exclusively charged at 3.3?kW, which is the common alternating current Level 2 charging power level. Comparable scaled charging protocols are also independently applied to individual cells at three different temperatures, 20?°C, 30?°C, and 40?°C, to perform a comparative analysis with the packs. Dominant cell-level aging modes were identified through incremental capacity analysis and compared with full packs to gain a clear understanding of additional key factors that affect pack aging. While the cell-level study showed a minor impact on performance due to direct current fast charging, the packs showed a significantly higher rate of capacity fade under similar charging protocols. This indicates that pack-level aging cannot be directly extrapolated from cell evaluation. Delayed fast charging, completing shortly before discharge, was found to have less of an impact on battery degradation than conventional alternating current Level 2 charging.

25 ENERGY STORAGE↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗

First Annual Progress Report on Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

The objective of this project is to develop and demonstrate methods for transmission of information in nuclear facilities by acoustic means along existing in-place metal piping infrastructure. Pipes are omnipresent in a nuclear facility, and penetrate enclosures and partitions, such as the containment building wall. In the envisioned acoustic communication (AC) system, packets of information will be transmitted as guided acoustic waves along pipes. Performance of AC hardware and network protocols for efficient and secure communications under development in this project will be eventually evaluated in a representative nuclear power plant environment. Research efforts in the first year of this project have been focused on identification of appropriate transducers, and evaluation of their performance for information transmission along nuclear-grade metallic pipes. COMSOL computer simulations were performed to study acoustic wave generation, propagation, and attenuation on pipes. An experimental benchtop system was used to evaluate signal attenuation and spectral dispersion using piezo-electric transducers (PZTs) and electromagnetic acoustic transducers (EMATs). Communication protocols under evaluation consisted on-off keying (OOK) signal modulation, in particular amplitude shift keying (ASK) and phase shift keying (PSK). Tradeoffs between signal power and communication data rate were considered for ASK and PSK coding schemes.

42 ENGINEERING↗

PacWave Anchoring and Mooring Study

PacWave, with its location in some of the most energetic waters in the nation and a buildout to support grid-connected devices, is poised to become a leader in field testing of wave energy converters (WECs) at high technology readiness levels. As part of the device deployment and testing protocols at PacWave, the client is responsible for providing all mooring system components, since there are currently no mooring system components specified for PacWave. NREL and PNNL have been tasked with conducting a preliminary analysis of permanent or temporary mooring systems at the PacWave South site. Previous work for this task included a global trade study of mooring systems used for WECs, and a site characterization of PacWave South. This current report will use the results of the previous studies to inform the design of various mooring systems to be installed at PacWave, which will allow cost analyses to be performed to compare the costs of acquisition of these mooring systems and the costs of mooring systems designed specifically for clients' devices.

16 TIDAL AND WAVE POWER↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

Quantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126

Purpose: The purpose of this study was to quantify the frequency and clinical severity of quality deficiencies in intensity modulated radiation therapy (IMRT) planning in the Radiation Therapy Oncology Group 0126 protocol. Methods and Materials: A total of 219 IMRT patients from the high-dose arm (79.2 Gy) of RTOG 0126 were analyzed. To quantify plan quality, we used established knowledge-based methods for patient-specific dose-volume histogram (DVH) prediction of organs at risk and a Lyman-Kutcher-Burman (LKB) model for grade ≥2 rectal complications to convert DVHs into normal tissue complication probabilities (NTCPs). The LKB model was validated by fitting dose-response parameters relative to observed toxicities. The 90th percentile (22 of 219) of plans with the lowest excess risk (difference between clinical and model-predicted NTCP) were used to create a model for the presumed best practices in the protocol (pDVH{sub 0126,top10%}). Applying the resultant model to the entire sample enabled comparisons between DVHs that patients could have received to DVHs they actually received. Excess risk quantified the clinical impact of suboptimal planning. Accuracy of pDVH predictions was validated by replanning 30 of 219 patients (13.7%), including equal numbers of presumed “high-quality,” “low-quality,” and randomly sampled plans. NTCP-predicted toxicities were compared to adverse events on protocol. Results: Existing models showed that bladder-sparing variations were less prevalent than rectum quality variations and that increased rectal sparing was not correlated with target metrics (dose received by 98% and 2% of the PTV, respectively). Observed toxicities were consistent with current LKB parameters. Converting DVH and pDVH{sub 0126,top10%} to rectal NTCPs, we observed 94 of 219 patients (42.9%) with ≥5% excess risk, 20 of 219 patients (9.1%) with ≥10% excess risk, and 2 of 219 patients (0.9%) with ≥15% excess risk. Replanning demonstrated the predicted NTCP reductions while maintaining the volume of the PTV receiving prescription dose. An equivalent sample of high-quality plans showed fewer toxicities than low-quality plans, 6 of 73 versus 10 of 73 respectively, although these differences were not significant (P=.21) due to insufficient statistical power in this retrospective study. Conclusions: Plan quality deficiencies in RTOG 0126 exposed patients to substantial excess risk for rectal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

Protein-based forensic identification using genetically variant peptides in human bone

Bone tissue contains organic material that is useful for forensic investigations and may contain preserved endogenous protein that can persist in the environment for extended periods of time over a range of conditions. Single amino acid polymorphisms in these proteins reflect genetic information since they result from non-synonymous single nucleotide polymorphisms (SNPs) in DNA. Detection of genetically variant peptides (GVPs) — those peptides that contain amino acid polymorphisms — in digests of bone proteins allows for the corresponding SNP alleles to be inferred. Resulting genetic profiles can be used to calculate statistical measures of association between a bone sample and an individual. In this study proteomic analysis on rib cortical bone samples from 10 recently deceased individuals demonstrates this concept. A straight-forward acidic demineralization protocol yielded proteins that were digested with trypsin. Tryptic digests were analyzed by liquid chromatography mass spectrometry. A total of 1736 different proteins were identified across all resulting datasets. On average, individual samples contained 454 ± 121 ($\bar{x}$ ± σ) proteins. Thirty-five genetically variant peptides were identified from 15 observed proteins. Overall, 134 SNP inferences were made based on proteomically detected GVPs, which were confirmed by sequencing of subject DNA. Inferred individual SNP genetic profiles ranged in random match probability (RMP) from 1/6 to 1/42,472 when calculated with European population frequencies in the 1000 Genomes Project, Phase 3. Similarly, RMPs based on African population frequencies were calculated for each SNP genetic profile and likelihood ratios (LR) were obtained by dividing each European RMP by the corresponding African RMP. In conclusion, resulting LR values ranged from 1.4 to 825 with a median value of 16. GVP markers offer a basis for the identification of compromised skeletal remains independent of the presence of DNA template.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

Controlling Water Vapor in Gas-Cell Microscopy Experiments

There is an increasing interest in understanding the role of water vapor on the high-temperature degradation behavior of structural materials when subjected to aggressive environments [1]. For example, thermal barrier coatings are used to protect turbine blades from high-temperature degradation and the presence of water vapor can substantially decrease lifetime [2]. Our aim here, is to develop methods and protocols for introducing and quantifying water vapor in a MEMS-based closed-cell in situ reactor system (Protochips AtmosphereTM), for studies focused on the effects of environmental exposure in high-temperature structural materials.

Unocic, Kinga↗

Effect of quasiperiodic and random noise on many-body dynamical decoupling protocols

Symmetries (and their spontaneous rupturing) can be used to protect and engender novel quantum phases and lead to interesting collective phenomena. In the work of K. Agarwal and I. Martin, the authors described a general dynamical decoupling (polyfractal) protocol that can be used to engineer multiple discrete symmetries in many-body systems. This work expands on the former by studying the effect of quasiperiodic and random noise on such a dynamical scheme. We find generally that relaxation of engineered symmetry generators proceeds by (i) an initial relaxation on microscopic timescales to a prethermal plateau whose height is independent of noise, (ii) a linear relaxation regime with a noise-dependent rate, followed by (iii) a slow logarithmic relaxation regime that is only present for quasiperiodic noise. We glean the essential features of these regimes via scaling collapses and show that they can be generally explained by the spectral properties of the various noise waveforms considered. In particular, the quasiperiodic noise is characterized by highly time-dependent spectrum with a noise floor that mimics white noise, and peaks that grow sharper with time. We argue that both the noise floor and peaks contribute to the initial linear-in-time relaxation while the logarithmic regime is initiated when the peaks become sufficiently well resolved and cease to contribute to further relaxation. Here, we provide numerical evidence to justify these findings.

74 ATOMIC AND MOLECULAR PHYSICS↗

Skyrme pseudopotentials at next-to-next-to-leading order: Construction of local densities and first symmetry-breaking calculations

There is an ongoing quest to improve on the spectroscopic quality of nuclear energy density functionals (EDFs) of the Skyrme type through extensions of its traditional form. One direction for such activities is the inclusion of terms of higher order in gradients in the EDF. We report on exploratory symmetry-breaking calculations performed for an extension of the Skyrme EDF that includes central terms with four gradients at next-to-next-to-leading order (N2LO) and for which the high-quality parametrization SN2LO1 has been constructed recently. Up to now, the investigation of such functionals with higher-order terms was limited to infinite matter and spherically symmetric configurations of singly and doubly magic nuclei. We address here nuclei and phenomena that require us to consider axial and nonaxial deformation, both for reflection-symmetric and also reflection-asymmetric shapes, as well as the breaking of time-reversal invariance. Achieving these calculations demanded a number of formal developments. These all resulted from the formulation of the N2LO EDF requiring the introduction of new local densities with additional gradients that are not present in the EDF at NLO. Their choice is not unique, but can differ in the way the gradients are coupled. While designing a numerical implementation of N2LO EDFs in Cartesian three-dimensional coordinate-space representation, we have developed a novel definition and a new unifying notation for normal and pair densities that contain gradients at arbitrary order. Besides having mnemonic advantages, the new notation allows for the easy identification of redundancies and reducibilities in a given set of local densities, and the new definition makes it straightforward to construct densities that automatically adopt the symmetries of the many-body state they are constructed from. The resulting scheme resolves several issues with some of the choices that have been made for local densities in the past, in particular when breaking time-reversal symmetry. Guided by general practical considerations, we propose an alternative form of the N2LO contribution to the Skyrme EDF that is built from a different set of densities. It has exactly the same physics content, but is much more efficient to handle in formal discussions and, compared to the original formulation, leads to a substantial reduction of computational cost and memory requirements in deformed codes. As representative examples for the performance of SN2LO1, we have chosen the ground states of even-even Kr and Nd isotopes, the fission barrier of 240 Pu as well as the superdeformed rotational band of 194 Hg. Overall, for the nuclei and phenomena studied here, the SN2LO1 parametrization does not yet present a systematic improvement over standard NLO parametrizations. This finding calls for improved fit protocols that better discriminate between NLO and N2LO terms and better exploit the unique features of the additional degrees of freedom offered by the latter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-BRA-05: Toward Understanding the Robustness of Radiomics Features in CT

Purpose: To gauge the impact of inter-scanner variability on radiomics features in computed tomography (CT). Methods: We compared the radiomics features calculated for 17 scans of the specially designed Credence Cartridge Radiomics (CCR) phantom with those calculated for 20 scans of non–small cell lung cancer (NSCLC) tumors. The scans were acquired at four medical centers using General Electric, Philips, Siemens, and Toshiba CT scanners. Each center used its own routine thoracic imaging protocol. To produce a large dynamic range of radiomics feature values, the CCR phantom has 10 cartridges comprising different materials. The features studied were derived from the neighborhood gray-tone difference matrix or image intensity histogram. To quantify the significance of the inter-scanner variability, we introduced the metric “feature noise”, which compares the ratio of inter-scanner variability and inter-patient variability in decibels, positive values indicating substantial noise. We performed hierarchical clustering based to look for dependence of the features on the scan acquisition parameters. Results: For 5 of the 10 features studied, the inter-scanner variability was larger than the inter-patient variability. Of the 10 materials in the phantom, shredded rubber seemed to produce feature values most similar to those of the NSCLC tumors. The feature busyness had the greatest feature noise (14.3 dB), whereas texture strength had the least (−14.6 dB). Hierarchical clustering indicated that the features depended in part on the scanner manufacturer, image slice thickness, and pixel size. Conclusion: The variability in the values of radiomics features calculated for CT images of a radiomics phantom can be substantial relative to the variability in the values of these features calculated for CT images of NSCLC tumors. These inter-scanner differences and their effects should be carefully considered in future radiomics studies.

60 APPLIED LIFE SCIENCES↗

SU-E-I-67: Arachnoid Cysts: The Role of the BLADE Technique

Purpose: The purpose of this study is first to show the extent by which BLADE sequences can reduce all the image artifacts and second to verify that the usefulness of this technique in certain pathological conditions is significant. Methods: In this study, fourteen consecutive patients (5 females, 9 males), who routinely underwent MRI brain examination, between 2010–2014, were selected. The applied routine protocols for brain MR examination included the following sequences: 1) T2-W FLAIR axial; 2) T2-W TSE axial; 3) T2*-W axial, 4) T1-W TSE sagittal; 5) DWI-W axial; 6) T1-W TSE axial; 7) T1-W TSE axial+contrast. In cases of cystic tumors, the T2-W FLAIR BLADE sequence was added to the protocol. All the images were evaluated independently at two separate settings with 3 weeks interval by two radiologists. The radiologists also evaluated the presence of image artifacts (motion, flow, chemical shift, Gibbs ringing). To evaluate the size of the cyst, the two radiologists compared the two techniques (conventional and BLADE) by assessing the extent of the divergence in the measurements of the cysts. Results: Regarding the extent of the cyst size, BLADE measurements were found to be more reliable than the conventional ones with the differences being statistically significant (p<0.01). The qualitative measurements indicated that the T2 FLAIR BLADE sequences were superior to the conventional T2 FLAIR with statistically significant differences (p<0.001) in the following characteristics: 1) overall image quality, 2) CSF nulling; 3) contrast at the pathology and its surrounding; 4) limits of the pathology; 5) motion artifacts; 6) flow artifacts; 7) chemical shift artifacts and 8) Gibbs ringing artifacts. Conclusion: BLADE sequence was found to decrease both flow artifacts in the temporal lobes and motion artifacts from the orbits and it is proposed for clinical use.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-05: EUTEMPE-RX: Combining E-Learning and Face-To-Face Training to Build Expert Knowledge, Skills and Competences for Medical Physicists in Diagnostic and Interventional Radiology

Purpose: In 2013, the EURATOM authorities of the European Commission decided to support the Horizon2020 project submission ‘EUTEMPE-RX’ that aimed for a new set of course modules to train medical physicists in diagnostic and interventional radiology to expert level with small group deep learning. Each module would consist of 2 phases: an e-learning and a face-to-face phase, each phase requiring typically 40h of participant time. Methods: The European Federation (EFOMP) and 13 European partners, all of them selected for their excellent scientific and/or educational skills, led the 12 course modules. A quality manual ensured the quality of course content and organization. Educational workshops familiarized the teachers with e-learning techniques and methods for assessment. Content was set in accordance with the EC document RP174 that lists learning outcomes in terms of knowledge, skills and competences (KSCs) for different specialties and levels of medical physics. Surveys for stake holder satisfaction were prepared. Results: Today the course modules are being realized. The modules cover most of the KSCs in RP174 document. Teachers have challenged the participants with unique tasks: case studies in medical physics leadership, Monte Carlo simulation of a complete x-ray imaging chain, development of a task specific QA protocol, compilation of optimization plans, simulation tasks with anthropomorphic breast models, etc. Participants undertook practical sessions in modern hospitals and visited a synchrotron facility, a calibration lab, screening organizations, etc. Feedback form quality surveys was very positive and constructive. A sustainability plan has been worked out. Conclusion: The modules have enabled the participants to develop their KSCs and cope with challenges in medical physics. The sustainability plan will be implemented to continue the unique combined e-learning and face to face training at high level training in diagnostic and interventional radiology also beyond Europe. The EUTEMPE-RX project is funded by the Horizon2020 - EURATOM program of the European Commission.

60 APPLIED LIFE SCIENCES↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

Clifford orbits from cayley graph quotients

We describe the structure of the $n$-qubit Clifford group $\mathcal{C}_n$ via Cayley graphs, whose vertices represent group elements and edges represent generators. In order to obtain the action of Clifford gates on a given quantum state, we introduce a quotient procedure. Quotienting the Cayley graph by the stabilizer subgroup of a state gives a reduced graph which depicts the state's Clifford orbit. Using this protocol for $\mathcal{C}_2$, we reproduce and generalize the reachability graphs. Since the procedure is state-independent, we extend our study to non-stabilizer states, including the W and Dicke states. Furthermore, our new construction provides a more precise understanding of state evolution under Clifford circuit action.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hepatocellular Metabolic Profile: Understanding Post-Thawing Metabolic Shift in Primary Hepatocytes In Vitro

Primary human hepatocytes (PHHs) are widely used as in vitro models for liver function and drug metabolism studies, yet their metabolic stability post-thawing remains an open question. To better characterize early metabolic changes, we conducted a time-course experiment using liquid chromatography-tandem mass spectrometry (LC-MS/MS) to analyze metabolic shifts in PHHs cultured in suspension. Unexposed and exposed (acetaminophen-treated) samples were evaluated, and TITAN analysis was applied to determine the time point of maximal metabolic change at both individual metabolite and global metabolic profile levels. Our results indicate that the majority of metabolic shifts occur within the first five hours post-thawing. In the early culture time points, substantial metabolic overlap was observed between unexposed and exposed cells, suggesting a conserved biological response likely related to cellular recovery. However, at later time points, metabolite profiles diverged, with acetaminophen treatment-specific metabolic changes emerging, potentially reflecting differences in homeostatic restoration versus hepatotoxic responses. Our study highlights the importance of considering early post-thawing metabolic dynamics in experimental design and offers insights for optimizing hepatocyte culture protocols to better replicate in vivo physiological conditions.

59 BASIC BIOLOGICAL SCIENCES↗