Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Assessment of shuttle payloads gaseous environment contamination and its control

A prediction is given of the in-orbit gaseous environment and the contamination it could produce on cryogenic and room temperature surfaces of payloads in the shuttle bay. The time varying environment was obtained by the superposition of the calculated shuttle environment for a discrete time and payload induced environments measured in large space chambers. Representative contaminant surface accretions were calculated for flights 1 week and 1 month long for payloads having the largest source of outgassing and an orbit of 200 km. A number of calculations were based on the magnitude of the sources, the molecular natures, the decay rate with time, the sticking coefficients, the view factors, and the temperatures of the surfaces being contaminated. Significant results are reported.

Scialdone, J. J.↗

Chemical-Biological Cyclic Process for Hexavalent Chromium Reduction to Trivalent Chromium in Aqueous Medium - 20224

Conventional treatment of chromium contamination focuses on immobilization of the highly toxic and water-soluble form Cr(VI), by reducing it to the relatively less toxic and less mobile trivalent form, Cr(III), using reducing compounds like ferrous sulfate or ferrous iron, Fe(II). The Cr(VI) also respond to biodegradation and subsequent reduction. During the reduction reaction, Fe(II) is oxidized to ferric, Fe(III), which, being at the highest oxidation state, has no ability to reduce Cr(VI), and therefore remediation process terminates. The good news is that metal-reducing bacteria, S. oneidensis MR-1, can regenerate Fe(II) from Fe(III) with the help of an organic electron donor in an appropriate bacterial media. Thus, in the Cr(VI) chemical remediation process, Fe(II) to Fe(III) conversion is reversed by the biological process, regenerating Fe(II) and the Cr(VI) chemical reduction process continues in a cyclic fashion. This study presents the results of regeneration of Fe(II) from fresh Fe(III) as well as from the reaction products of Cr(VI) and Fe(II). Both fresh Fe(III) and reaction product Fe(III) exhibited the same reduction behavior. Fe(II) production increased with the increase of initial concentration of Fe(III), resulting in 87.5% Fe(II) regeneration. The extent of Fe(III) reduction (Fe(II)t/Fe(III)0.hour) was 21 times higher than the extent of Cr(VI) reduction (Cr(VI)t/Cr(VI)0.hour) by S. oneidensis MR-1. In a cyclic process of sequential Cr(VI) addition, the amount of Fe(II) regeneration decreased with the increase in cycle number, a fixed quantity of starting S. oneidensis MR-1 could regenerate Fe(II) at least five times in a ten-hour period. More importantly, regenerated Fe(II) instantly reduced Cr(VI) to Cr(III). So, Fe(II) regeneration with metal-reducing bacteria has a good potential for application in groundwater and wastewater remediation in reducing Cr(VI) to Cr(III). As a comparison of chemical to biological transformation, chemical transformation of Cr(VI) by Fe(II) was almost 600 times greater than that of biological transformation. Therefore a chemical-biological cyclic process offers potential applications for remediation of groundwater and hexavalent chromium contaminated waste sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of substrate pretreatments on the atomic layer deposited Al{sub 2}O{sub 3} passivation quality

The authors show here that the passivation quality of Al{sub 2}O{sub 3} is highly sensitive to the surface condition prior to the atomic layer deposition, affecting especially the thermal stability of the film. Pretreatments like diluted HCl bath or preheating at 200 °C both improved significantly the passivation quality and thermal stability of the films. In addition, the authors observed that a thin chemical SiO{sub 2} layer resulting from diluted HCl solves the blistering problem often encountered in H{sub 2}O based atomic layer deposited process. Finally, the authors show that the chemical oxide protects the surface from contaminants, enabling long storage times in a dirty ambient between the cleaning and the film deposition.

36 MATERIALS SCIENCE↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Engine Plume Interaction Calculations for Prototypical Prometheus 1

Prometheus 1 is a conceptual mission to demonstrate the use of atomic energy for distant space missions. The hypothetical spacecraft design considered in this paper calls for multiple ion thrusters, each with considerably higher beam energy and beam current than have previously flown in space. The engineering challenges posed by such powerful thrusters relate not only to the thrusters themselves, but also to designing the spacecraft to avoid potentially deleterious effects of the thruster plumes. Accommodation of these thrusters requires good prediction of the highest angle portions of the main beam, as well as knowledge of clastically scattered and charge exchange ions, predictions for grid erosion and contamination of surfaces by eroded grid material, and effects of the plasma plume on radio transmissions. Nonlinear interactions of multiple thrusters are also of concern. In this paper we describe two- and three-dimensional calculations for plume structure and effects of conceptual Prometheus 1 ion engines. Many of the techniques used have been validated by application to ground test data for the NSTAR and NEXT ion engines. Predictions for plume structure and possible sputtering and contamination effects will be presented.

Mandell, Myron J.↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emerging Contaminants: Identification, Life Cycle, and Key Challenges - 20415

The term 'emerging contaminants' and its multiple variants has come to refer to previously overlooked compounds discovered in the environment which represent a potential threat to human and ecological receptors. These compounds may be discovered in the environment as new analytical techniques are developed and/or as new monitoring programs for drinking water and groundwater are implemented, while the threat to receptors may be realized through advances in understanding of toxicology and pathways to receptors. Emerging contaminants present unique and considerable challenges as demands to address them can outpace the understanding of their toxicity, their need for regulation, their occurrence, and techniques for treating the environmental media they affect. With these challenges in mind, this paper serves as a primer for understanding emerging contaminants. The paper will lay a foundation for understanding emerging contaminants through three key topics: 1. Who identifies emerging contaminants? An overview of the various stakeholder groups around the world working on identifying potential emerging contaminants and developing systems for screening potential candidates, prioritizing, and ultimately generating regulations will be provided. 2. How Chemicals Rise into Awareness as Emerging Contaminants. The process by which contaminants emerge through a cycle of awareness, characterization, management and regulation will be discussed. Current emerging contaminants will be discussed in the context of the life cycle: emerging contaminants where impacts to drinking water supplies are driving public awareness (e.g. per and polyfuoroalkyl substances (PFASs) and 1,4-dioxane), emerging contaminants impacted by changing regulatory standards or development and debate on toxicity (e.g., hexavalent chromium, 1,2,3-trichloropropane, trichloroethylene in vapor intrusion), and those with evolving understanding of impacts and usage (e.g., microplastics). 3. Key Challenges. Unique challenges associated with emerging contaminants, including visibility and public sensitivity, uncertainty and vulnerability, will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Elucidating the Dynamic Nature of Fuel Cell Electrodes as a Function of Conditioning: An ex Situ Material Characterization and in Situ Electrochemical Diagnostic Study

To increase the commercialization of fuel cell electric vehicles, it is imperative to improve the activity and performance of electrocatalysts through combined efforts focused on material characterization and device-level integration. Obtaining fundamental insights into the ongoing structural and compositional changes of electrocatalysts is crucial for not only transitioning an electrode from its as-prepared to functional state, also known as 'conditioning', but also for establishing intrinsic electrochemical performances. Here, we investigated several oxygen reduction reaction (ORR) electrocatalysts via in situ and ex situ characterization techniques to provide fundamental insights into the interfacial phenomena that enable peak ORR mass activity and high current density performance. A mechanistic understanding of a fuel cell conditioning procedure is described, which encompasses voltage cycling and subsequent voltage recovery (VR) steps at low potential. In particular, ex situ membrane electrode assembly characterization using transmission electron microscopy and ultra-small angle X-ray scattering were performed to determine changes in carbon and Pt particle size and morphology, while in situ electrochemical diagnostics were performed either during or after specific points in the testing protocol to determine the electrochemical and interfacial changes occurring on the catalyst surface responsible for oxygen transport resistances through ionomer films. The results demonstrate that the voltage cycling (break-in) step aids in the removal of sulfate and fluoride and concomitantly reduces non-Fickian oxygen transport resistances, especially for catalysts where Pt is located within the pores of the carbon support. Subsequent low voltage holds at low temperature and oversaturated conditions, i.e., VR cycles, serve to improve mass activities by a factor of two to three, through a combined removal of contaminants, surface-blocking species (e.g., oxides), and rearrangement of the catalyst atomic structure (e.g., Pt-Pt and Pt-Co coordination).

30 DIRECT ENERGY CONVERSION↗

Removal of Historic Low-Level Radioactive Waste from the Highland Drive South and Alexander Street Ravines - 19155

In Port Hope, the Highland Drive South Ravine (HDSR) is the discharge area for groundwater originating from the closed Highland Drive Landfill site. The presence of low-level radioactive waste (LLRW) in the HDSR is the result of a contaminated groundwater plume flowing from the landfill site. The contaminant plume contains elevated concentrations of uranium and arsenic and extends from the landfill south to discharge groundwater to shallow soils in a wet discharge area within the ravine. The groundwater discharges to Hunt's Ponds and Highland Drive South Creek, which are immediately downstream of the wet discharge area and will be included in the remediation design. Remediation and environmental management plans for HDSR have been developed within the framework of the Port Hope Project. Recent subsurface investigations have identified LLRW at greater depths than previously anticipated. Other investigations of surrounding properties have identified LLRW that is primarily from filling activities in backyards. The steep topography of the site and the presence of the creek and seepage face present remediation challenges. Also in Port Hope, the LLRW in the Alexander Street Ravine Area is the result of end dumping, filling of private backyards and stack deposition from the former refinery. The original site extent was focused on the deeper contamination due to end dumping and included a portion of Alexander Creek. However, recent investigations have confirmed other fill areas and the extent of stack deposition that are generally contiguous with the end dumping area. Restricted access to the site will result in all remediation in this area taking place via a single access point along the narrow existing Hayward Street. While both of these sites are ravines in Port Hope containing LLRW, the origins of contamination and remediation approaches are very different. This paper will compare these two challenging remediation sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicting the impact of land management decisions on overland flow generation: Implications for cesium migration in forested Fukushima watersheds

The effects of land use and land cover (LULC) change on environmental systems across the land surface's “critical zone” are highly uncertain, often making prediction and risk management decision difficult. In a series of numerical experiments with an integrated hydrologic model, overland flow generation is quantified for both present day and forest thinning scenarios. A typhoon storm event in a watershed near the Fukushima Dai-ichi Nuclear Power Plant is used as an example application in which the interplay between LULC change and overland flow generation is important given that sediment-bound radionuclides may cause secondary contamination via surface water transport. Results illustrate the nonlinearity of the integrated system spanning from the deep groundwater to the atmosphere, and provide quantitative tools when determining the tradeoffs of different risk-mitigation strategies.

54 ENVIRONMENTAL SCIENCES↗

Predicted cumulative dose to firefighters and the offsite public from natural and anthropogenic radionuclides in smoke from wildland fires at the Savannah River Site, South Carolina USA

The contaminated ground surface at Savannah River Site (SRS) is a result of the decades of work that has been performed maintaining the country's nuclear stockpile and performing research and development on nuclear materials. The volatilization of radionuclides during wildfire results in airborne particles that are dispersed within the smoke plume and may result in doses to downwind firefighters and the public. To better understand the risk that these smoke plumes present, we have characterized four regions at SRS in terms of their fuel characteristics and radiological contamination on the ground. Combined with general meteorological conditions describing typical and extreme burn conditions, we have simulated potential fires in these regions and predicted the potential radiological dose that could be received by firefighting personnel and the public surrounding the SRS. In all cases, the predicted cumulative dose was a small percent of the US Department of Energy regulatory limit (0.25 mSv). These predictions were conservative and assumed that firefighters would be exposed for the duration of their shift and the public would be exposed for the entire day over the duration of the burn. Realistically, firefighters routinely rotate off the firefront during their shift and the public would likely remain indoors much of the day. However, we show that even under worst-case conditions the regulatory limits are not exceeded. In conclusion, we can infer that the risks associated with wildfires would not be expected to cause cumulative doses above the level of concern to either responding personnel or the offsite public.

54 ENVIRONMENTAL SCIENCES↗

Plasma Surface Functionalization of AFP Manufactured Composites for Improved Adhesive Bond Performance

Application of carbon fiber reinforced polymer (CFRP) as a high-performance structural material has widespread application in the present aerospace industry. However, as-processed composite materials require a comprehensive surface treatment prior to bonding to remove contaminants and impart surface functionality and topography to overcome their poor adhesion properties. Atmospheric pressure plasma jet treatment (APPJT) has been increasingly garnering attention as an alternate method for surface preparation of CFRP. This method has been reported to achieve success in imparting favorable polar functional groups into the composite surfaces enhancing wettability and surface energy of the bonded surfaces. In some cases, APPJT has been demonstrated to remove contaminants or, in the case of silicones, convert them to silica. In this study, an atmospheric pressure plasma jet (APPJ) system was used for surface activation of a composite laid-up by an automated fiber placement (AFP) machine. Surface modifications prior to and after treatment were characterized using water contact angle (WCA) measurements, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Double cantilever beam (DCB) tests were performed to quantify the bonding performance of the composites. The results show a marked enhancement of the mode I interlaminar fracture toughness with the application of APPJT.

Sarikaya, Ibrahim↗

ATLAS: Story Maps for Communicating Groundwater Cleanup Status - 18510

The U.S. Department of Energy (DOE) manages one of the largest groundwater cleanup efforts in the world in terms of the number of plumes, diversity of contaminants, volume of affected groundwater, and diversity of hydrogeologic settings. The DOE Office of Environmental Management (EM) has been collecting site-specific data on plume sizes, remedial approaches, exit strategies, long-term stewardship requirements, and regulatory drivers at all DOE sites, and summarizing them in a single document to communicate high-level information on groundwater contamination and cleanup status to DOE managers. Recently, EM has sponsored an effort to transfer the document-based information to an online resource for collating information on groundwater plumes that is easily accessible by interested parties. Specifically, Web GIS story maps have been developed to provide a robust geospatial visualization of plumes at DOE sites using an intuitive interface that allows users to explore plume maps, explanatory text, photographs, and video provided within the story maps. This collection of story maps is called ATLAS (Assembly of Tools for Learning Actions and Status), and not only communicates groundwater plume data for each individual site, but also summarizes pertinent metrics across all EM sites. With ATLAS, sites with similar settings, contamination, or remedial approaches can be easily identified, facilitating effective communication among DOE sites and sharing of individual successes and lessons learned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Amplicon Sequencing Assessment to Measure Microbial Community Response from Heavy Metal Contaminated Soils in Savannah River site, Tims Branch watershed

Long-term presence of heavy metal contamination in soils is correlated with changes in microbial community structures and can lead to the reduction of indigenous species. Tolerance to soil heavy metal toxicity varies among different microbial communities. It remains unclear whether long term effects caused by metal perturbations are associated with soil microbial community dysregulation in Tims Branch watershed. Research Questions: Does heavy metal contamination in Tims Branch soils decrease microbial species diversity significantly compared to non-contaminated soils? Does the species richness decrease in contaminated samples? between samples? Is diversity in low, mid and high contamination soils significantly different compared to control samples? Hypothesis: The relative abundance and diversity of species are significantly altered in soils which are contaminated with heavy metals in the Tims Branch watershed. Objectives: Use amplicon sequencing technology along with bioinformatics to compare bacterial communities between four sites in Tims Branch watershed. Evaluate the percent relative abundance and diversity across the site. Conclusions: All bacterial communities exposed to different heavy metal concentrations were dominated by four major groups (Proteobacteria, Acidobacteria, Chloroflexi and Verrucomicrobia). The dominant phyla Proteobacteria, Acidobacteria and Chloroflexi accounted for 61 % of the relative abundance. Soil bacterial α-diversity, expressed as observed species richness metric and Shannon's diversity index, was the highest in sample location four (high contamination). The lowest observed was at the control location. Species richness increased when concentrations of heavy metals were localized, inferring that the metals can alter microbial community structure. PERMANOVA analysis between contaminated groups tested significant using the Adonis (F (4,29) =1.9712; p < 0.001). There is a 20 percent variation explained between groups (R2 = 0.214). This analysis proves to be beneficial in detecting microbial communities altered by contaminated soils. Moreover, certain concentrations of heavy metals can alter microbial community structures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 100: An Integrated Systems-Based Monitoring Approach

This panel focused on recent advancements in monitoring and remaining challenges associated with the implementing cost-effective monitoring approaches for complex DOE sites. Monitoring presents one of the largest, long-term costs for environmental remediation and site stewardship within the DOE because contamination at complex sites will likely be present for tens to hundreds of years into the future. Integration of monitoring with predictive modeling is an approach that can reduce long-term monitoring costs as well as support the effective monitoring design and data interpretation for managing a site toward closure and long-term stewardship. Panelists with presentations: Autonomous Electrical Geophysical Monitoring of Contaminated Sites (Tim Johnson); Systems Based Long-Term Monitoring for DOE Legacy Management (David Shafer); Long-Term Systems Based Monitoring (Anderson Ward)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗