Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Evaluation of Hanford Supernatant Waste Evaporation

Storage space within Hanford’s double shell tanks is running low, with only an approximate 4.1 Mgal of space remaining. Construction of additional storage space is not a pursuable option, but treatment of the waste via vacuum evaporation may be used to reduce the waste volume and increase the available amount of free space. However, without proper care and consideration, concentrating the waste may lead to harmful effects such as excessive solids generation, growth in liquid density and ionic concentration, and development of aggressive properties in the solution. OLI Studio was used to simulate a subset of DSTs using BBI ionic concentrations to generate recipes of every tank’s supernatant layer. Vacuum evaporation was performed by taking each simulated solution and bringing it to 50°C under a pressure of 60 Torr, after which the vapor phase was removed from the simulation, and the solution was brought back to ambient temperature and pressure. Several million gallons of space were created, and only about 100-200 kgal of solids were precipitated during evaporation. Minimal changes to the solution’s pitting factor occurred, and no solution is expected to develop aggressive characteristics due to evaporation. Although a theoretical result is provided, it is unique to the specific temperature and pressure value chosen for the simulation, and future transfers of waste are expected to cause changes in waste properties, which would cause the OLI recipes to lose accuracy. Though the results are not anticipated to be used as a target value or a guide, as an exercise, they show that the extent of volume gains could be equivalent to the construction of new DSTs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Saturn Radiation Dose Environment Characterization

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

All-metal metamaterial slow-wave structure for high-power sources with high efficiency

In this paper, we have proposed a metamaterial (MTM) which is suitable for the compact high-power vacuum electron devices. For example, an S-band slow-wave structure (SWS) based on the all-metal MTMs has been studied by both simulation and experiment. The results show that this MTM SWS is very helpful to miniaturize the high-power vacuum electron devices and largely improve the output power and the electronic efficiency. The simulation model of an S-band MTM backward wave oscillator (BWO) is built, and the particle-in-cell simulated results are presented here: a 2.454 GHz signal is generated and its peak output power is 4.0 MW with a higher electronic efficiency of 31.5% relative to the conventional BWOs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating the Excited-State Dynamics of Polaritons with Ab Initio Multiple Spawning

Over the past decade, there has been a growth of interest in polaritonic chemistry, where the formation of hybrid light–matter states (polaritons) can alter the course of photochemical reactions. These hybrid states are created by strong coupling between molecules and photons in resonant optical cavities and can even occur in the absence of light when the molecule is strongly coupled with the electromagnetic fluctuations of the vacuum field. Here, we present a first-principles model to simulate nonadiabatic dynamics of such polaritonic states inside optical cavities by leveraging graphical processing units (GPUs). Our first implementation of this model is specialized for a single molecule coupled to a single-photon mode confined inside the optical cavity but with any number of excited states computed using complete active space configuration interaction (CASCI) and a Jaynes–Cummings-type Hamiltonian. Using this model, we have simulated the excited-state dynamics of a single salicylideneaniline (SA) molecule strongly coupled to a cavity photon with the ab initio multiple spawning (AIMS) method. We demonstrate how the branching ratios of the photodeactivation pathways for this molecule can be manipulated by coupling to the cavity. We also show how one can stop the photoreaction from happening inside of an optical cavity. Finally, we also investigate cavity-based control of the ordering of two excited states (one optically bright and the other optically dark) inside a cavity for a set of molecules, where the dark and bright states are close in energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Midplane neutral density profiles in the National Spherical Torus Experiment

Atomic and molecular density data in the outer midplane of NSTX [Ono et al., Nucl. Fusion 40, 557 (2000)] are inferred from tangential camera data via a forward modeling procedure using the DEGAS 2 Monte Carlo neutral transport code. The observed Balmer-β light emission data from 17 shots during the 2010 NSTX campaign display no obvious trends with discharge parameters such as the divertor Balmer-α emission level or edge deuterium ion density. Simulations of 12 time slices in 7 of these discharges produce molecular densities near the vacuum vessel wall of 2–8 × 10{sup 17 }m{sup −3} and atomic densities ranging from 1 to 7 × 10{sup 16 }m{sup −3}; neither has a clear correlation with other parameters. Validation of the technique, begun in an earlier publication, is continued with an assessment of the sensitivity of the simulated camera image and neutral densities to uncertainties in the data input to the model. The simulated camera image is sensitive to the plasma profiles and virtually nothing else. The neutral densities at the vessel wall depend most strongly on the spatial distribution of the source; simulations with a localized neutral source yield densities within a factor of two of the baseline, uniform source, case. The uncertainties in the neutral densities associated with other model inputs and assumptions are ≤50%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D kinetic-ion simulations of inverted corona fusion targets

Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Higher Dimensional Spacetimes for Visualizing and Modeling Subluminal, Luminal and Superluminal Flight

This paper briefly explores higher dimensional spacetimes that extend Meholic's visualizable, fluidic views of: subluminal-luminal-superluminal flight; gravity, inertia, light quanta, and electromagnetism from 2-D to 3-D representations. Although 3-D representations have the potential to better model features of Meholic's most fundamental entities (Transluminal Energy Quantum) and of the zero-point quantum vacuum that pervades all space, the more complex 3-D representations loose some of the clarity of Meholic's 2-D representations of subluminal and superlumimal realms. So, much new work would be needed to replace Meholic's 2-D views of reality with 3-D ones.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluations of Candidate Materials for Advanced Space-Rated Vacuum Seals to Explore Space Environment Exposure Limits

For many materials used in space hardware, the environment in which they need to operate is harsher than the environment on earth. Exposure to vacuum conditions, atomic oxygen, and ultraviolet radiation can be detrimental, so testing of space hardware in simulated space environments is required. This is especially true for elastomeric components such as seals. NASA is developing advanced space-rated vacuum seals in support of future space exploration missions. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air during extended-duration missions. In some applications the seals are not mated during portions of the mission and are left uncovered and exposed to the conditions in space for prolonged periods of time prior to mating. Space-rated vacuum seals are often made of silicone because of the material's wide operating temperature range and ability to be molded or extruded into various shapes and cross sections. One approach being considered to achieve improved performance is to add titanium dioxide to the silicone material to make it more resistant to damage from ultraviolet radiation. In this study, seals made of the baseline material with and without 1.5 percent titanium dioxide additive (by weight) were exposed to atomic oxygen and increasing levels of ultraviolet radiation and then leak tested. Test results revealed that seals made of the new material could withstand longer exposures while still satisfying the leak rate requirement even under worst-case conditions of partial compression at the extremes of the anticipated operating temperature range.

Seals↗

Evaluations of Candidate Materials for Advanced Space-Rated Vacuum Seals to Explore Space Environment Exposure Limits

For many materials used in space hardware, the environment in which they need to operate is harsher than the environment on earth. Exposure to vacuum conditions, atomic oxygen, and ultraviolet radiation can be detrimental, so testing of space hardware in simulated space environments is required. This is especially true for elastomeric components such as seals. NASA is developing advanced space-rated vacuum seals in support of future space exploration missions. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air during extended-duration missions. In some applications the seals are not mated during portions of the mission and are left uncovered and exposed to the conditions in space for prolonged periods of time prior to mating. Space-rated vacuum seals are often made of silicone because of the material's wide operating temperature range and ability to be molded or extruded into various shapes and cross sections. One approach being considered to achieve improved performance is to add titanium dioxide to the silicone material to make it more resistant to damage from ultraviolet radiation. In this study, seals made of the baseline material with and without 1.5% titanium dioxide additive (by weight) were exposed to atomic oxygen and increasing levels of ultraviolet radiation and then leak tested. Test results revealed that seals made of the new material could withstand longer exposures while still satisfying the leak rate requirement even under worst-case conditions of partial compression at the extremes of the anticipated operating temperature range.

Ultraviolet radiation↗

Simulation of Molecular Hydrogen Jets and Visualization of Associated Hydrodynamic Features [Slides]

A numerical method is presented for solving the Navier-Stokes equations to represent a steady-state hydrogen jet expanding into a vacuum chamber. This numerical method has been evaluated using three test problems with promising results. Simulations of the hydrogen jet indicate the presence of a low temperature region (less than 15 K) within the jet for the high flow rate case. The high flow rate case also gives rise to a large recirculation region within the jet. The conditions at the minimum temperature point within the jet approach the hydrogen sublimation line when the mass flow rate exceeds 2 g/s, which may allow for the formation of hydrogen ice crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time transients in the quantum corrected Newtonian potential induced by a massless nonminimally coupled scalar field

We calculate the one-loop graviton vacuum polarization induced by a massless, nonminimally coupled scalar field on Minkowski background. We make use of the Schwinger-Keldysh formalism, which allows us to study time dependent phenomena. As an application we compute the leading quantum correction to the Newtonian potential of a point particle. The novel aspect of the calculation is the use of the Schwinger-Keldysh formalism, within which we calculate the time transients induced by switching on the graviton-scalar coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coil-On-Plug Ignition for LOX/Methane Liquid Rocket Engines in Thermal Vacuum Environments

A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX) / liquid methane rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/methane propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. In order to successfully demonstrate ignition reliability in the vacuum conditions and eliminate corona discharge issues, a coil-on-plug ignition system has been developed. The ICPTA uses spark-plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark-plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp.-2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, Plum Brook testing demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/methane propulsion systems in future spacecraft.

Melcher, John C.↗

On the possibility of neutron generation in an imploding TiD{sub 2} puff Z pinch

Simulation of implosion of a TiD{sub 2} puff Z pinch is reported. The Z pinch is supposed to be produced by the plasma flow generated by a vacuum arc, as described by Rousskikh et al.[Phys. Plasmas 18, 092707 (2011)]. To simulate the implosion, a one-dimensional two-temperature radiative magnetohydrodynamics code was used. The simulation has shown that neutrons are generated during the implosion of a TiD{sub 2} puff Z pinch due to thermalization of the pinch plasma stagnated on axis. It has been shown that the necessary condition for neutron generation is that the ion temperature must be substantially higher than the electron temperature. For a pinch current of 1 MA, the predicted yield of 'thermal' neutrons is 2.5 × 10{sup 9} neutrons/shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative interpretation of molecular dynamics simulations for X-ray photoelectron spectroscopy of aqueous solutions

Over the past decade, energy-dependent ambient pressure X-ray photoelectron spectroscopy (XPS) has emerged as a powerful analytical probe of the ion spatial distributions at the vapor (vacuum)-aqueous electrolyte interface. These experiments are often paired with complementary molecular dynamics (MD) simulations in an attempt to provide a complete description of the liquid interface. There is, however, no systematic protocol that permits a straightforward comparison of the two sets of results. XPS is an integrated technique that averages signals from multiple layers in a solution even at the lowest photoelectron kinetic energies routinely employed, whereas MD simulations provide a microscopic layer-by-layer description of the solution composition near the interface. Here, we use the National Institute of Standards and Technology database for the Simulation of Electron Spectra for Surface Analysis (SESSA) to quantitatively interpret atom-density profiles from MD simulations for XPS signal intensities using sodium and potassium iodide solutions as examples. We show that electron inelastic mean free paths calculated from a semi-empirical formula depend strongly on solution composition, varying by up to 30% between pure water and concentrated NaI. The XPS signal thus arises from different information depths in different solutions for a fixed photoelectron kinetic energy. XPS signal intensities are calculated using SESSA as a function of photoelectron kinetic energy (probe depth) and compared with a widely employed ad hoc method. SESSA simulations illustrate the importance of accounting for elastic-scattering events at low photoelectron kinetic energies (<300 eV) where the ad hoc method systematically underestimates the preferential enhancement of anions over cations. Finally, some technical aspects of applying SESSA to liquid interfaces are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous thermal vacuum testing of GPS drives for NavStar

The solar array drive assemblies for the global positioning satellite (GPS) were built and the need to perform thermal vacuum acceptance testing on at least two complete units simultaneously is emphasized. The safety of the flight hardware is of primary importance. It is found that simultaneous space simulation testing of two complete drive packages requires only minor modification to the high vacuum pump stack. Attention is given to upgrading system safeties for high vacuum operation. Major modifications are designed and implemented for the thermal control system and supporting subsystems. The automated thermal control system and test bed hardware are of primary interest.

Brown, T. G.↗

Coil-On-Plug Ignition for Oxygen/Methane Liquid Rocket Engines in Thermal-Vacuum Environments

A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX)/liquid methane (LCH4) rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/LCH4 propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. A coil-on-plug ignition system has been developed to successfully demonstrate ignition reliability at these conditions while preventing corona discharge issues. The ICPTA uses spark plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp -2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, hot-fire testing at Plum Brook demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/LCH4 propulsion systems in future spacecraft.

Melcher, John C.↗