Search NASA⌕ Search

SEARCH · Search NASA

Results for “well testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

NLO perturbativity bounds on quartic couplings in renormalizable theories with Φ 4 -like scalar sectors

The apparent breakdown of unitarity in low order perturbation theory is often is used to place bounds on the parameters of a theory. In this work we give an algorithm for approximately computing the next-to-leading order (NLO) perturbativity bounds on the quartic couplings of a renormalizable theory whose scalar sector is Φ 4 -like. And by this we mean theories where either there are no cubic scalar interactions, or the cubic couplings are related to the quartic couplings through spontaneous symmetry breaking. Furthermore, the quantity that tests where perturbation theory breaks down itself can be written as a perturbative series, and having the NLO terms allows one to test how well the series converges. We also present a simple example to illustrate the effect of considering these bounds at different orders in perturbation theory. For example, there is a noticeable difference in the viable parameter when the square of the NLO piece is included versus when it is not.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kaon Photoproduction and the Λ Decay Parameter α –

The weak decay parameter $\alpha_-$ of the $\Lambda$ is an important quantity for the extraction of polarization observables in various experiments. Moreover, in combination with $\alpha_+$ from $\bar\Lambda$ decay it provides a measure for matter-antimatter asymmetry. The weak decay parameter also affects the decay parameters of the $\Xi$ and $\Omega$ baryons and, in general, any quantity in which the polarization of the $\Lambda$ is relevant. The recently reported value by the BESIII collaboration of $0.750(9)(4)$ is significantly larger than the previous PDG value of $0.642(13)$ that had been accepted and used for over 40 years. In this work we make an independent estimate of $\alpha_-$, using an extensive set of polarization data measured in kaon photoproduction in the baryon resonance region and constraints set by spin algebra. The obtained value is 0.721(6)(5). The result is corroborated by multiple statistical tests as well as a modern phenomenological model, showing that our new value yields the best description of the data in question. Furthermore, our analysis supports the new BESIII finding that $\alpha_-$ is significantly larger than the previous PDG value. Any experimental quantity relying on the value of $\alpha_-$ should therefore be re-considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

Individual Load Model Parameter Estimation in Distribution Systems Using Load Switching Events

There currently exists a mature literature on modeling the aggregate load of a distribution feeder by making use of measurements at its feeder-head at substation. The primary application of such feeder-aggregated load models is in sub-transmission or transmission system analysis. However, there is a growing need in practice also to model each individual load across the feeder. If available, such individual load models have applications in power distribution system analysis, e.g., to better integrate distributed energy resources or to improve power quality and reliability. Motivated by this observation, in this paper, we propose a new method for individual load modeling in power distribution systems. It works by using the measurements only at the feeder-head. It takes an innovative approach to analyzing the load switching events across the distribution feeder itself, instead of or in addition to relying on upstream voltage events that are commonly used in feeder-aggregated load modeling. By tracking the downstream load switching events, the proposed method can make a robust estimation of the ZIP load model parameters for all individual loads. The proposed method is examined on small illustrative test-feeders as well as the IEEE 33-bus test system under various operating scenarios. The adverse impact of errors in measurements and system parameters are also investigated on the performance of the developed load modeling method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection in Partially Observed Traffic Networks

This paper addresses the problem of detecting anomalous activity in traffic networks where the network is not directly observed. Given knowledge of what the node-tonode traffic in a network should be, any activity that differs significantly from this baseline would be considered anomalous. We propose a Bayesian hierarchical model for estimating the traffic rates and detecting anomalous changes in the network. The probabilistic nature of the model allows us to perform statistical goodness-of-fit tests to detect significant deviations from a baseline network. We show that due to the more defined structure of the hierarchical Bayesian model, such tests perform well even when the empirical models estimated by the EM algorithm are misspecified. Finally, we apply our model to both simulated and real datasets to demonstrate its superior performance over existing alternatives.

97 MATHEMATICS AND COMPUTING↗

The control system of the fatigue test stand under biaxial tension—compression

In this paper, a system for control of the hydraulic test stand for biaxial tension—compression of cruciform specimens was presented. The system is equipped with six control loops and two compensators of amplitude, which improve the machine operation. The elaborated mechatronic system based on the biaxial strength machine realizes the planned fatigue tests very well.

42 ENGINEERING↗

Application of PHADEC method for the decontamination of radioactive steam piping components

The dismantling of nuclear plants is a complex activity that originates often a large quantity of radioactive contaminated residue. In this paper the attention was focused on the PHADEC (Phosphoric Acid Decontamination) plant adopted for the clearance of Caorso NPP (in Italy) metallic systems and components contaminated by Co{sup 60} (produced by the neutron capture in the iron materials), like the main steam lines, moisture separator of the turbine buildings, etc.. The PHADEC plant consists in a chemical off line treatment: the crud, deposited along the steam piping during life plant as an example, is removed by means of acid attacks in ponds coupled to a high pressure water washing. Due to the fact that the removed contaminated layers, essentially, iron oxides of various chemical composition, depend on components geometry, type of contamination and time of treatment in the PHADEC plant, it becomes of meaningful importance to suggest a procedure capable to improve the control of the PHADEC process parameters. This study aimed thus at the prediction and optimization of the mentioned treatment time in order to improve the efficiency of the plant itself and to achieve, in turn, the minimization of produced wastes. To the purpose an experimental campaign was carried out by analysing several samples, i.e. taken along the main steam piping line. Smear tests as well as metallographic analyses were carried out in order to determine respectively the radioactivity distribution and the crud composition on the inner surface of the components. Moreover the radioactivity in the crud thickness was measured. These values allowed finally to correlate the residence time in the acid attack ponds to the level of the achieved decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

Experimental validation of the van Herk margin formula for lung radiation therapy

Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available within ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-36: Comparison of CBCT Image Quality for Manufacturer Default Imaging Modes

Purpose CBCT is being increasingly used in patient setup for radiotherapy. Often the manufacturer default scan modes are used for performing these CBCT scans with the assumption that they are the best options. To quantitatively assess the image quality of these scan modes, all of the scan modes were tested as well as options with the reconstruction algorithm. Methods A CatPhan 504 phantom was scanned on a TrueBeam Linear Accelerator using the manufacturer scan modes (FSRT Head, Head, Image Gently, Pelvis, Pelvis Obese, Spotlight, & Thorax). The Head mode scan was then reconstructed multiple times with all filter options (Smooth, Standard, Sharp, & Ultra Sharp) and all Ring Suppression options (Disabled, Weak, Medium, & Strong). An open source ImageJ tool was created for analyzing the CatPhan 504 images. Results The MTF curve was primarily dictated by the voxel size and the filter used in the reconstruction algorithm. The filters also impact the image noise. The CNR was worst for the Image Gently mode, followed by FSRT Head and Head. The sharper the filter, the worse the CNR. HU varied significantly between scan modes. Pelvis Obese had lower than expected HU values than most while the Image Gently mode had higher than expected HU values. If a therapist tried to use preset window and level settings, they would not show the desired tissue for some scan modes. Conclusion Knowing the image quality of the set scan modes, will enable users to better optimize their setup CBCT. Evaluation of the scan mode image quality could improve setup efficiency and lead to better treatment outcomes.

60 APPLIED LIFE SCIENCES↗

Universal interferometric signatures of a black hole’s photon ring

The Event Horizon Telescope image of the supermassive black hole in the galaxy M87 is dominated by a bright, unresolved ring. General relativity predicts that embedded within this image lies a thin “photon ring,” which is composed of an infinite sequence of self-similar subrings that are indexed by the number of photon orbits around the black hole. The subrings approach the edge of the black hole “shadow,” becoming exponentially narrower but weaker with increasing orbit number, with seemingly negligible contributions from high-order subrings. Here, we show that these subrings produce strong and universal signatures on long interferometric baselines. These signatures offer the possibility of precise measurements of black hole mass and spin, as well as tests of general relativity, using only a sparse interferometric array.

79 ASTRONOMY AND ASTROPHYSICS↗

Marker ReDistancing/Level Set Method for High-Fidelity Implicit Interface Tracking

A hybrid of the Front-Tracking (FT) and the Level-Set (LS) methods is introduced, combining advantages and removing drawbacks of both methods. The kinematics of the interface is treated in a Lagrangian (FT) manner, by tracking markers placed at the interface. The markers are not connected – instead, the interface topology is resolved in an Eulerian (LS) framework, by wrapping a signed distance function around Lagrangian markers each time the markers move. For accuracy and efficiency, we have developed a high-order “anchoring” algorithm and an implicit PDE-based re-distancing. We have demonstrated that the method is 3rd-order accurate in space, near the markers, and therefore 1st-order convergent in curvature; in contrast to traditional PDE-based re-initialization algorithms, which tend to slightly relocate the zero Level Set and can be shown to be non-convergent in curvature. The implicit pseudo-time discretization of the re-distancing equation is implemented within the Jacobian-Free Newton Krylov (JFNK) framework combined with ILU(k) preconditioning. We have demonstrated that the steady-state solutions in pseudo-time can be achieved very efficiently, with iterations (CFL ), in contrast to the explicit re-distancing which requires 100s of iterations with CFL . The most cost-effective algorithm is found to be a hybrid of explicit and implicit discretizations, in which we apply first 10-15 iterations with explicit discretization (to bring the initial guess to the ball of convergence for the Newton’s method) and then finishing with 2-3 implicit steps, bringing the re-distancing equation to a complete steady-state. The eigenscopy of the JFNK-ILU(k) demonstrates the efficiency of the ILU(k) preconditioner, which effectively cluster eigenvalues of the otherwise extremely ill-conditioned Jacobian matrices, thereby enabling the Krylov (GMRES) method to converge with iterations, with only a few levels of ILU fill-ins. Importantly, due to the Level Set localization, the bandwidth of the Jacobian matrix is nearly constant, and the ILU preconditioning scales as , which implies efficiency and good scalability of the overall algorithm. The numerical examples include the well-established tests for interface kinematics under translational, rotational and tearing/stretching motion. We have shown that the mass conservation is not an issue anymore, as demonstrated using the Rider&Kothe’s time-reversed tests with extreme deformation. We are able to stretch interface structures to the under-resolved/subgrid (on the chosen Eulerian mesh) scales, and recover them back without any change in shape/loss of mass.

99 GENERAL AND MISCELLANEOUS↗

Bringing Trimmed Serendipity Methods to Computational Practice in Firedrake

We present an implementation of the trimmed serendipity finite element family, using the open-source finite element package Firedrake. The new elements can be used seamlessly within the software suite for problems requiring H 1 , H (curl), or H (div)-conforming elements on meshes of squares or cubes. To test how well trimmed serendipity elements perform in comparison to traditional tensor product elements, we perform a sequence of numerical experiments including the primal Poisson, mixed Poisson, and Maxwell cavity eigenvalue problems. Overall, we find that the trimmed serendipity elements converge, as expected, at the same rate as the respective tensor product elements, while being able to offer significant savings in the time or memory required to solve certain problems.

97 MATHEMATICS AND COMPUTING↗

Reactive Flows in Porous Media: Challenges in Theoretical and Numerical Methods

We review theoretical and computational research, primarily from the past 10 years, addressing the flow of reactive fluids in porous media. The focus is on systems where chemical reactions at the solid–fluid interface cause dissolution of the surrounding porous matrix, creating nonlinear feedback mechanisms that can often lead to greatly enhanced permeability. Here, we discuss insights into the evolution of geological forms that can be inferred from these feedback mechanisms, as well as some geotechnical applications such as enhanced oil recovery, hydraulic fracturing, and carbon sequestration. Until recently, most practical applications of reactive transport have been based on Darcy-scale modeling, where averaged equations for the flow and reactant transport are solved. We summarize the successes and limitations of volume averaging, which leads to Darcy-scale equations, as an introduction to pore-scale modeling. Pore-scale modeling is computationally intensive but offers new insights as well as tests of averaging theories and pore-network models. We include recent research devoted to validation of pore-scale simulations, particularly the use of visual observations from microfluidic experiments.

wormhole formation↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗