At least 91 records · Page 5

Measuring the mass of the black widow PSR J1555-2908

ABSTRACT Accurate measurements of the masses of neutron stars are necessary to test binary evolution models, and to constrain the neutron star equation of state. In pulsar binaries with no measurable post-Keplerian parameters, this requires an accurate estimate of the binary system’s inclination and the radial velocity of the companion star by other means than pulsar timing. In this paper, we present the results of a new method for measuring this radial velocity using the binary synthesis code Icarus. This method relies on constructing a model spectrum of a tidally distorted, irradiated star as viewed for a given binary configuration. This method is applied to optical spectra of the newly discovered black widow PSR J1555–2908. By modeling the optical spectroscopy alongside optical photometry, we find that the radial velocity of the companion star is 397 ± 4 km s−1 (errors quoted at 95 per cent confidence interval), as well as a binary inclination of >75°. Combined with γ-ray pulsation timing information, this gives a neutron star mass of 1.67$^{+0.15}_{-0.09}$ M⊙ and a companion mass of 0.060$^{+0.005}_{-0.003}$ M⊙, placing PSR J1555–2908 at the observed upper limit of what is considered a black widow system.

Kennedy, M. R.↗

The spectra of IceCube neutrino (SIN) candidate sources – II. Source characterization

ABSTRACT Eight years after the first detection of high-energy astrophysical neutrinos by IceCube, we are still almost clueless as regards to their origin, although the case for blazars being neutrino sources is getting stronger. After the first significant association at the $3\!-\!3.5\, \sigma$ level in time and space with IceCube neutrinos, i.e. the blazar TXS 0506+056 at z = 0.3365, some of us have in fact selected a unique sample of 47 blazars, out of which ∼16 could be associated with individual neutrino track events detected by IceCube. Building upon our recent spectroscopy work on these objects, here we characterize them to determine their real nature and check if they are different from the rest of the blazar population. For the first time we also present a systematic study of the frequency of masquerading BL Lacs, i.e. flat-spectrum radio quasars with their broad lines swamped by non-thermal jet emission, in a γ-ray- and IceCube-selected sample, finding a fraction >24 per cent and possibly as high as 80 per cent. In terms of their broad-band properties, our sources appear to be indistinguishable from the rest of the blazar population. We also discuss two theoretical scenarios for neutrino emission, one in which neutrinos are produced in interactions of protons with jet photons and one in which the target photons are from the broad-line region. Both scenarios can equally account for the neutrino–blazar correlation observed by some of us. Future observations with neutrino telescopes and X-ray satellites will test them out.

79 ASTRONOMY AND ASTROPHYSICS↗

INTEGRAL reloaded: Spacecraft, instruments and ground system

The European Space Agency’s INTErnational Gamma-Ray Astrophysics Laboratory (ESA/INTEGRAL) was launched aboard a Proton-DM2 rocket on 17 October 2002 at 06:41 CEST, from Baikonur in Kazakhstan. Since then, INTEGRAL has been providing long, uninterrupted observations (up to about 47 h, or 170 ksec, per satellite orbit of 2.7 days) with a large field-of-view (FOV, fully coded: 100 deg), millisecond time resolution, keV energy resolution, polarization measurements, as well as additional wavelength coverage at optical wavelengths. This is realized by two main instruments in the 15 keV to 10 MeV energy range, the spectrometer SPI (spectral resolution 3 keV at 1.8 MeV) and the imager IBIS (angular resolution: 12 arcmin FWHM), complemented by X-ray (JEM-X; 3–35 keV) and optical (OMC; Johnson V-band) monitor instruments. All instruments are co-aligned to simultaneously observe the target region. A particle radiation monitor (IREM) measures charged particle fluxes near the spacecraft. The Anti-coincidence subsystems of the main instruments, built to reduce the background, are also very efficient all-sky γ-ray detectors, which provide virtually omni-directional monitoring above ~75 keV. Besides the long, scheduled observations, INTEGRAL can rapidly (within a couple of hours) re-point and conduct Target of Opportunity (ToO) observations on a large variety of sources. INTEGRAL observations and their scientific results have been building an impressive legacy: The discovery of currently more than 600 new high-energy sources; the first-ever direct detection of (56)Ni and (56)Co radio-active decay lines from a Type Ia supernova; spectroscopy of isotopes from galactic nucleo-synthesis sources; new insights on enigmatic positron annihilation in the Galactic bulge and disk; and pioneering gamma-ray polarization studies. INTEGRAL is also a successful actor in the new multi-messenger astronomy introduced by non-electromagnetic signals from gravitational waves and from neutrinos: INTEGRAL found the first prompt electromagnetic radiation in coincidence with a binary neutron star merger. Up to now more than 1750 scientific papers based on INTEGRAL data have been published in refereed journals. In this paper, we will give a comprehensive update of the satellite status after more than 18 years of operations in a harsh space environment, and an account of the successful Ground Segment.

Erik Kuulkers↗

EP 250108a/SN 2025kg: Observations of the Most Nearby Broad-line Type Ic Supernova Following an Einstein Probe Fast X-Ray Transient

With a small sample of fast X-ray transients (FXTs) with multiwavelength counterparts discovered to date, their progenitors and connections to γ-ray bursts (GRBs) and supernovae (SNe) remain ambiguous. Here, we present photometric and spectroscopic observations of SN 2025kg, the SN counterpart to the FXT EP 250108a. At z = 0.17641, this is the closest known SN discovered following an Einstein Probe (EP) FXT. We show that SN 2025kg’s optical spectra reveal the hallmark features of a broad-lined Type Ic SN. Its light-curve evolution and expansion velocities are comparable to those of GRB-SNe, including SN 1998bw, and two past FXT-SNe. We present JWST/NIRSpec spectroscopy taken around SN 2025kg’s maximum light, and find weak absorption due to He I 1.0830 μm and 2.0581 μm and a broad, unidentified emission feature at ∼4–4.5 μm. Further, we observe broadened Hα in optical data at 42.5 days that is not detected at other epochs, indicating interaction with H-rich material. From its light curve, we derive a 56 Ni mass of 0.2–0.6 M ⊙ . Together with our companion Letter, our broadband data are consistent with a trapped or low-energy (≲10 51 erg) jet-driven explosion from a collapsar with a zero-age main-sequence mass of 15–30 M ⊙ . Finally, we show that the sample of EP FXT-SNe supports past estimates that low-luminosity jets seen through FXTs are more common than successful (GRB) jets, and that similar FXT-like signatures are likely present in at least a few percent of the brightest Type Ic-BL SNe.

79 ASTRONOMY AND ASTROPHYSICS↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

γIn-beam angular distribution and linear polarization measurements with GRETINA using a simple energy-ordering approach

Angular distribution and linear polarization measurements are powerful tools for inferring the spins and parities of nuclear levels. In this work, the performance of the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter was characterized in a fusion-evaporation reaction experiment using a simple energy-ordering approach for the interaction points assigned in the signal decomposition process. A variety of multipolarities and characters for γ-ray transitions in the reaction products 25 Mg, 25 Na, and 22 Ne, formed from fusion-evaporation of an 18 O beam on a 9 Be target, were examined. The experimental angular distributions and linear polarization asymmetries were consistent with predictions using the theoretical formalism accounting for the Lorentz boost.

Angular distribution↗

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

Linker Contribution toward Stability of Metal–Organic Frameworks under Ionizing Radiation

Here, the effects of radiation on a series of UiO derivative metal–organic frameworks (MOFs) that contain the same zirconium hexamer node and similar organic linkers, UiO-66, UiO-66–NH 2 , UiO-66–OH, and NU-403, were examined using γ-rays and 5 MeV He ions. UiO-66, UiO-66–NH2, and UiO-66–OH contain aromatic linkers and are significantly more stable to radiation than NU-403. Of these, UiO-66 is the most radiation resistant, displaying crystalline features up to 47 MGy of He-ion irradiation. MOFs containing aromatic linkers functionalized by electron-donating groups, UiO-66–NH 2 and UiO-66–OH, retained crystalline features up to 19 MGy. NU-403 contains aliphatic rings and is the least radiation-resistant MOF studied here. NU-403 exhibits small changes in infrared spectra upon 3 MGy of γ-irradiation and significant damage upon 10 MGy of He-ion irradiation. Diffraction data revealed radiation-induced defect formation. Structural locations of radiation-induced breakdown were interrogated experimentally and via density functional theory. The results indicated changes in the carboxylate (-OCO) of the linker and μ 3 -OH vibrational modes, suggesting that introduction of an aliphatic linker into the MOF renders the connection between the linker and metal node most susceptible to radiation damage. This study reveals that the choice of the linker is crucial in designing a radiation-resistant MOF.

36 MATERIALS SCIENCE↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Demonstration of Energy-Resolved γ-Ray Detection at Room Temperature by the CsPbCl 3 Perovskite Semiconductor

The detection of gamma-rays at room temperature with high-energy resolution using semiconductors is one of the most challenging applications. The presence of even the smallest amount of defects is sufficient to kill the signal generated from gamma-rays which makes the availability of semiconductors detectors a rarity. Lead halide perovskite semiconductors exhibit unusually high defect tolerance leading to outstanding and unique optoelectronic properties and are poised to strongly impact applications in photoelectric conversion/detection. Here we demonstrate for the first time that large size single crystals of the all-inorganic perovskite CsPbCl 3 semiconductor can function as a high-performance detector for gamma-ray nuclear radiation at room temperature. CsPbCl 3 is a wide-gap semiconductor with a bandgap of 3.03 eV and possesses a high effective atomic number of 69.8. We identified the two distinct phase transitions in CsPbCl 3 , from cubic (Pm-3m) to tetragonal (P4/mbm) at 325 K and finally to orthorhombic (Pbnm) at 316 K. Despite crystal twinning induced by phase transitions, CsPbCl 3 crystals in detector grade can be obtained with high electrical resistivity of similar to 1.7 X 10 9 Ω∙cm. The crystals were grown from the melt with volume over several cubic centimeters and have a low thermal conductivity of 0.6 W m -1 K -1 . The mobilities for electron and hole carriers were determined to similar to 30 cm 2 /(V s). Using photoemission yield spectroscopy in air (PYSA), we determined the valence band maximum at 5.66 +/- 0.05 eV. Under gamma-ray exposure, our Schottky-type planar CsPbCl 3 detector achieved an excellent energy resolution (similar to 16% at 122 keV) accompanied by a high figure-of-merit hole mobility-lifetime product (3.2 x 10 -4 cm 2 /V) and a long hole lifetime (16 mu s). The results demonstrate considerable defect tolerance of CsPbCl 3 and suggest its strong potential for gamma-radiation and X-ray detection at room temperature and above.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Spectroscopy of a sample of unidentified gamma-ray Fermi sources

ABSTRACT The fourth-DR3 version (4FGL-DR3) of the Fermi-LAT catalogue of γ-ray sources contains ∼1000 objects at a galactic latitude |b| > 10° that are not identified with an optical counterpart. We performed a systematic study of these sources, focusing on 190 objects that have a unique X-ray counterpart in the available Swift/XRT observations. Optical counterparts were then selected, and optical spectra were found in the literature for 33 sources. We found that 21 could be classified as BL Lac objects. Among these, we were able to provide the redshift for eight of them, while for two others we established a lower limit to the redshift by detecting intervening absorption. The other 12 objects display optical spectra with prominent emission lines (0.036 < z < 1.65). These spectra are characterized by both broad and narrow emission lines, with the exception of three sources. One of these displays only broad emission lines, while the other two exclusively exhibit narrow lines. On the basis of the radio/optical flux ratio, all BL Lac objects in this study are radio-loud. Four sources out of the 12 with prominent emission lines can be classified as radio-loud, while at least five of the 12 sources with prominent lines are radio-quiet. This is somewhat unexpected, given the radio-loudness distribution of 4FGL-associated blazars.

Ulgiati, Alberto (ORCID:0009000736025276)↗

25 Siβ + -decay spectroscopy

Background: β-decay spectroscopy provides valuable information on exotic nuclei and a stringent test for nuclear theories beyond the stability line. Purpose: To search for new β-delayed protons and γ rays of 25 Si to investigate the properties of 25 Al excited states. Method: 25 Si β decays were measured by using the Gaseous Detector with Germanium Tagging system at the National Superconducting Cyclotron Laboratory. The protons and γ rays emitted in the decay were detected simultaneously. Here, a Monte Carlo method was used to model the Doppler broadening of 24 Mg γ-ray lines caused by nuclear recoil from proton emission. Shell-model calculations using two newly developed universal sd-shell Hamiltonians were performed. Results: The most precise 25Si half-life to date has been determined. A new proton branch at 724(4) keV and new proton-γ-ray coincidences have been identified. Three 24 Mg γ-ray lines and eight 25 Al γ-ray lines are observed for the first time in 25 Si decay. The first measurement of the 25 Si β-delayed γ-ray intensities through the 25 Al unbound states is reported. All the bound states of 25 Al are observed to be populated in the β decay of 25 Si. Several inconsistencies between the previous measurements have been resolved, and new information on the 25 Al level scheme is provided. An enhanced decay scheme has been constructed and compared to the mirror decay of 25 Na and the shell-model calculations. Conclusions: The measured excitation energies, γ-ray and proton branchings, log $ft$ values, and Gamow-Teller transition strengths for the states of 25 Al populated in the β decay of 25 Si are in good agreement with the shell model calculations, offering gratifyingly consistent insights into the fine nuclear structure of 25 Al.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential neutron-induced γ-ray background on natural tellurium relevant to 130 Te 0 ν ββ decay searches at the CUORE and SNO+ detectors

Gamma-ray production cross-section data have been obtained for the inelastic neutron scattering reactions 126,128,130 Te(n,n'γ) at five neutron energies between 3.6 and 10 MeV. We report data for the γ-ray energy region relevant to 0ν ββ decay of 130 Te with a Q ββ value of 2527.515 keV, assuming natural-abundance tellurium, as used at CUORE and SNO+. The natural abundance of 130 Te, 128 Te, and 126 Te is 34%, 32%, and 19%, respectively. For CUORE the γ-ray cascades from the excited state in 130 Te at 2527.06 keV and in 126 Te at 2533.85 keV are of concern. For SNO+, accounting for its inferior energy resolution, an additional four levels are important in 130 Te, an additional nine levels in 128 Te, and an additional eight levels in 126 Te. Of these, we report neutron-induced γ-ray production cross sections for the strongest transitions: the 2581.15 keV level in 130 Te, the 2494.20, 2508.06, and 2630.14 keV levels in 128 Te, and the 2496.83 and 2585.46 keV level in 126 Te. Here, the largest cross-section values were found for cascade γ-ray transitions to the ground state, while direct transitions to the ground state are very weak and were not observed in the present work. Both the CUORE and SNO+ detectors, however, may not be able to distinguish between cascade transitions and direct transitions to the ground state, making the neutron-induced excitation of the 2527.06 keV state of 130 Te in particular a potential problem for 0νββ decay searches of 130Te, because it matches its Q ββ value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of B 11 and Ca 40 levels at 8–9 MeV by nuclear resonance fluorescence

Here, we report on the measurement of 11 B and 40 Ca levels between excitation energies of 8 and 9 MeV using nuclear resonance fluorescence (NRF). The experiment was carried out with nearly monoenergetic and linearly polarized photon beams provided by the High-Intensity γ-ray Source (HIγS) facility at the Triangle Universities Nuclear Laboratory (TUNL). States in 11 B are important for calibrations of NRF measurements, while the properties of 40 Ca levels impact potassium nucleosynthesis in globular clusters. For 40 Ca, we report on improved excitation energies and an unambiguous 2¯ assignment for the state at 8425 keV. For 11 B, we obtained improved values for γ-ray multipolarity mixing ratios and branching ratios of the 8920-keV level.