Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm{sup 2} scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements performed during a 24-month period show very stable beam characteristics, which are therefore suitable for performing safe and accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

Intensity inhomogeneity correction for magnetic resonance imaging of human brain at 7T

Purpose: To evaluate the performance and efficacy for intensity inhomogeneity correction of various sequences of the human brain in 7T MRI using the extended version of the unified segmentation algorithm. Materials: Ten healthy volunteers were scanned with four different sequences (2D spin echo [SE], 3D fast SE, 2D fast spoiled gradient echo, and 3D time-of-flight) by using a 7T MRI system. Intensity inhomogeneity correction was performed using the “New Segment” module in SPM8 with four different values (120, 90, 60, and 30 mm) of full width at half maximum (FWHM) in Gaussian smoothness. The uniformity in signals in the entire white matter was evaluated using the coefficient of variation (CV); mean signal intensities between the subcortical and deep white matter were compared, and contrast between subcortical white matter and gray matter was measured. The length of the lenticulostriate (LSA) was measured on maximum intensity projection (MIP) images in the original and corrected images. Results: In all sequences, the CV decreased as the FWHM value decreased. The differences of mean signal intensities between subcortical and deep white matter also decreased with smaller FWHM values. The contrast between white and gray matter was maintained at all FWHM values. LSA length was significantly greater in corrected MIP than in the original MIP images. Conclusions: Intensity inhomogeneity in 7T MRI can be successfully corrected using SPM8 for various scan sequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brittle Fracture of 2D MoSe 2

An in situ quantitative tensile testing platform is developed in this paper to enable the uniform in-plane loading of a freestanding membrane of 2D materials inside a scanning electron microscope. The in situ tensile testing reveals the brittle fracture of large-area MoSe 2 crystals and measures their fracture strength for the first time.

36 MATERIALS SCIENCE↗

Performance Enhancement of PFET Planar Devices by Plasma Immersion Ion Implantation (P3I)

A study of doping the pMOS Lightly Doped Drain (LDD) by Plasma Immersion Ion Implantation (P3i) with BF3 is presented which demonstrates a better transistor performance compared to standard beam line Ion Implantation (I/I). The benefit of P3i comes from the broad angular distribution of the impinging ions thereby doping the poly-silicon gate sidewall as well. Gate capacitance of short channel devices has been measured and clearly shows this improvement. This model is clearly supported by high resolution 2D-carrier profiles using Scanning Spreading Resistance Microscopy (SSRM) which shows this gate sidewall doping. The broad angular distribution also implies a smaller directional sensitivity (to for instance the detailed gate edge shape) and leads to devices which are perfectly balanced, when Source and Drain electrode are switched.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural phase transitions in a MoWSe 2 monolayer: Molecular dynamics simulations and variational autoencoder analysis

Electrical and optoelectronic properties of two-dimensional (2D) transition metal dichalcogenides (TMDCs) can be tuned by exploiting their structural phase transitions. Here semiconducting (2H) to metallic (1T) phase transition is investigated in a strained MoWSe 2 monolayer using molecular dynamics (MD) simulations. Novel intermediate structures called α and β are found between the 2H and 1T phases. These intermediate structures are similar to those observed in a 2D MoS 2 by scanning transmission electron microscopy. Here, a deep generative model, namely the variational autoencoder (VAE) trained by MD data, is used to generate novel heterostructures with α and β interfaces. Quantum simulations based on density functional theory show that these heterostructures are stable and suitable for novel nanoelectronics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalous Superfluid Density in a Disordered Charge-Density-Wave Material: Pd-Intercalated ErTe 3

We image local superfluid density in single crystals of Pd-intercalated ErTe 3 below the superconducting critical temperature T c , well below the onset temperature T CDW of (disordered) charge-density-wave order. We find no detectable inhomogeneities on micron scales. Furthermore, we observe a rapid increase of the superfluid density below T c , deviating from the behavior expected in a conventional Bardeen-Cooper-Schrieffer superconductor, and show that the temperature dependence is qualitatively consistent with a combination of quantum and thermal phase fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0.078, SSIM 0.999±0.001, and HD 5.926±6.141mm. Conclusion: The developed automatic segmentation strategy, which yields accurate brain tumor delineation in evaluation cases, is promising for its application in SRS treatment planning.

60 APPLIED LIFE SCIENCES↗

Nano-infrared imaging of metal insulator transition in few-layer 1T-TaS 2

Abstract Among the family of transition metal dichalcogenides, 1T-TaS 2 stands out for several peculiar physical properties including a rich charge density wave phase diagram, quantum spin liquid candidacy and low temperature Mott insulator phase. As 1T-TaS 2 is thinned down to the few-layer limit, interesting physics emerges in this quasi 2D material. Here, using scanning near-field optical microscopy, we perform a spatial- and temperature-dependent study on the phase transitions of a few-layer thick microcrystal of 1T-TaS 2 . We investigate encapsulated air-sensitive 1T-TaS 2 prepared under inert conditions down to cryogenic temperatures. We find an abrupt metal-to-insulator transition in this few-layer limit. Our results provide new insight in contrast to previous transport studies on thin 1T-TaS 2 where the resistivity jump became undetectable, and to spatially resolved studies on non-encapsulated samples which found a gradual, spatially inhomogeneous transition. A statistical analysis suggests bimodal high and low temperature phases, and that the characteristic phase transition hysteresis is preserved down to a few-layer limit.

42 ENGINEERING↗

Combined microscopy studies of complex electronic materials. Final report

The aim of this project was to study the electronic properties of exotic electronic materials which are only available as micron-scale samples or have microscopic inhomogeneity, using a special combination of multiple submicron scanning microscopy techniques allied to control of temperature, magnetic and electric fields and mechanical strain. In nanobeams of VO 2 , with its still mysterious metal-insulator phase transition, we determined the phase diagram and demonstrated that hydrogen diffusion is strongly channelled along one crystal axis. Using graphene, we developed and applied the scanning photo-Nernst effect, in which a current is generated when a laser is focused on the edge a sample in a magnetic field. We demonstrated that CrI 3 , a two-dimensional layered magnet, retains true Ising ferromagnetization down the monolayer level due to its out-of-plane anisotropy. In exfoliated WTe 2 , a layered topological semimetal, we discovered that monolayers are the first monolayer topological insulator and we imaged the helical edge states with scanning microwave microscopy. We also discovered that the same material when stacked in a few layers is a ferroelectric metal, and that the monolayer can be converted to a superconducting state by electron doping with a gate a temperatures below 1 K. Additionally, we developed the capability to perform momentum-resolved electronic spectroscopy on operating nanoscale devices by applying micron-scale angle resolved photoemission spectroscopy to two-dimensional heterostructure devices incorporating graphene and transition metal dichalcogenide semiconductors. Using it, we measured the band gaps of a series of monolayer semiconductors and observed band renormalization as a function of electron doping in monolayer WSe 2 .

36 MATERIALS SCIENCE↗

X-RAY ABSORPTION SPECTROSCOPY OF YB3+-DOPED OPTICAL FIBERS

Optical fibers doped with Ytterbium-3+ have become increasingly common in fiber lasers and amplifiers. Yb-doped fibers provide the capability to produce high power and short pulses at specific wavelengths, resulting in highly effective gain media. However, little is known about the local structure, distribution, and chemical coordination of Yb3+ in the fibers. This information is necessary to improve the manufacturing process and optical qualities of the fibers. Five fibers doped with Yb3+ were studied using Extended X-ray Absorption Fine Structure (EXAFS) spectroscopy and X-ray Absorption Near Edge Spectroscopy (XANES), in addition to Yb3+ mapping. The Yb3+ distribution in each fiber core was mapped with 2D and 1D intensity scans, which measured X-ray fluorescence over the scan areas. Two of the five fibers examined showed highly irregular Yb3+ distributions in the core center. In four of the five fibers Yb3+ was detected outside of the given fiber core dimensions, suggesting possible Yb3+ diffusion from the core, manufacturing error, or both. X-ray absorption spectroscopy (XAS) analysis has so far proven inconclusive, but did show that the fibers had differing EXAFS spectra. The Yb3+ distribution mapping proved highly useful, but additional modeling and examination of fiber preforms must be conducted to improve XAS analysis, which has been shown to have great potential for the study of similar optical fi bers.

Citron, Robert↗

Mechanical design of laminar weak-link mechanisms with centimeter-level travel range and sub-nanometer positioning resolution

An enhanced mechanical design for laminar weak-link mechanisms with centimeter-level travel range and sub-nanometer positioning resolution is provided. A multiple parallelogram weak-link structure includes a predefined pattern of a plurality of perpendicularly arranged groups of connecting links, each link having at least one pair of weak-link connections. Each of the plurality of perpendicularly arranged groups includes a terminal for mounting to a fixed base. The multiple parallelogram weak-link structure includes a moving part for mounting on a carriage, providing precisely controlled movement with stability in one direction. A two-dimensional (2D) ultra-precision scanning stages assembly for x-ray nanoprobe applications includes multiple redundantly constrained weak-link structures, a vertical ultra-precision positioning stage, and a horizontal ultra-precision positioning stage.

42 ENGINEERING↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

Profiling the local carrier concentration across a semiconductor quantum dot

We profile the local carrier concentration, n, across epitaxial InAs/GaAs quantum dots (QDs) consisting of 3D islands on top of a 2D alloy layer. We use scanning thermoelectric microscopy to measure a profile of the temperature gradient-induced voltage, which is converted to a profile of the local Seebeck coefficient, S. The S profile is then converted to a conduction band-edge profile and compared with Poisson-Schrodinger band-edge simulations. Our combined computational-experimental approach suggests a reduced carrier concentration in the QD center in comparison to that of the 2D alloy layer. The relative roles of free carrier trapping and/or dopant expulsion are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low-dimensional hyperthin FeS 2 nanostructures for efficient and stable hydrogen evolution electrocatalysis

We report a scalable, solution-processing method for synthesizing low-dimensional hyperthin FeS 2 nanostructures, and we show that 2D FeS 2 disc nanostructures are an efficient and stable hydrogen evolution electrocatalyst. By changing the Fe:S ratio in the precursor solution, we were able to preferentially synthesize either 1D wire or 2D disc nanostructures. The 2D FeS 2 disc structure has the highest electrocatalytic activity for the hydrogen evolution reaction, comparable to platinum in neutral pH conditions. Moreover, the ability of the FeS 2 nanostructures to generate hydrogen was confirmed by scanning electrochemical microscopy, and the 2D disc nanostructures were able to generate hydrogen for over 125 h.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RockFlow: Fast Generation of Synthetic Source Rock Images Using Generative Flow Models

Image-based evaluation methods are a valuable tool for source rock characterization. The time and resources needed to obtain images has spurred development of machine-learning generative models to create synthetic images of pore structure and rock fabric from limited image data. While generative models have shown success, existing methods for generating 3D volumes from 2D training images are restricted to binary images and grayscale volume generation requires 3D training data. Shale characterization relies on 2D imaging techniques such as scanning electron microscopy (SEM), and grayscale values carry important information about porosity, kerogen content, and mineral composition of the shale. Here, we introduce RockFlow, a method based on generative flow models that creates grayscale volumes from 2D training data. We apply RockFlow to baseline binary micro-CT image volumes and compare performance to a previously proposed model. We also show the extension of our model to 2D grayscale data by generating grayscale image volumes from 2D SEM and dual modality nanoscale shale images. The results show that our method underestimates the porosity and surface area on the binary baseline datasets but is able to generate realistic grayscale image volumes for shales. With improved binary data preprocessing, we believe that our model is capable of generating synthetic porous media volumes for a very broad class of rocks from shale to carbonates to sandstone.

58 GEOSCIENCES↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗