Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Orion Launch Abort Vehicle Attitude Control Motor Testing

Current Orion Launch Abort Vehicle (LAV) configurations use an eight-jet, solid-fueled Attitude Control Motor (ACM) to provide required vehicle control for all proposed abort trajectories. Due to the forward position of the ACM on the LAV, it is necessary to assess the effects of jet-interactions (JI) between the various ACM nozzle plumes and the external flow along the outside surfaces of the vehicle. These JI-induced changes in flight control characteristics must be accounted for in developing ACM operations and LAV flight characteristics. A test program to generate jet interaction aerodynamic increment data for multiple LAV configurations was conducted in the NASA Ames and NASA Langley Unitary Plan Wind Tunnels from August 2007 through December 2009. Using cold air as the simulant gas, powered subscale models were used to generate interaction data at subsonic, transonic, and supersonic test conditions. This paper presents an overview of the complete ACM JI experimental test program for Orion LAV configurations, highlighting ACM system modeling, nozzle scaling assumptions, experimental test techniques, and data reduction methodologies. Lessons learned are discussed, and sample jet interaction data are shown. These data, in conjunction with computational predictions, were used to create the ACM JI increments for all relevant flight databases.

Murphy, Kelly J.↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Sensor and Instrumentation Systems within Advanced Condition Monitoring Technologies

Advanced condition monitoring (ACM) technologies, such as digital twins, are innovative strategies designed to provide real-time health insights, including the remaining useful life of components. The primary goal of ACM is to predict and alert operators to potential functional failures before they occur. ACM systems achieve this by integrating predictive models with various sensor instrumentation, analog-to-digital converters, data warehouses, and data pre-processors. These sensor and instrumentation systems (SIS) are essential for forming a comprehensive understanding of component conditions and ensuring the predictive success of ACM programs. Introducing new technologies like ACM involves varying degrees of risk that can impact plant reliability. Therefore, risk mitigation should be commensurate with the performance and reliability of the developed technology, following a risk-informed graded approach (RIGA). Establishing a RIGA process requires a clear understanding of the hazards and reliability of all subsystems, including their interdependencies and potential impacts on the overall system. Given the critical role of SIS in ACM, this work reviews hazard identification and reliability quantification methods for SIS. It also considers these methods' implications when developing a RIGA process for ACM.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Cardiovascular Comorbidity and Mortality in Men With Prostate Cancer Treated With Brachytherapy-Based Radiation With or Without Hormonal Therapy

Purpose: To assess the impact of coronary artery disease (CAD) risk factors and sequelae on the risk of all-cause mortality (ACM) in men treated for prostate cancer (PC). Methods and Materials: The study cohort comprised 5077 men with PC consecutively treated with curative intent between 1997 and 2006 at the Chicago Prostate Cancer Center. Cox and Fine and Gray's competing risks regression multivariable analyses were performed, assessing whether cardiovascular comorbidity impacted the risk of ACM and PC-specific mortality, respectively, adjusting for CAD risk factors (diabetes mellitus, hypercholesterolemia, or hypertension) and sequelae (congestive heart failure or myocardial infarction), age, year and type of treatment, and known PC prognostic factors. Results: When compared with men with no comorbidity there was a significantly increased risk of ACM in men with congestive heart failure or myocardial infarction (adjusted hazard ratio [AHR] 1.96, P<.001) and in men with diabetes mellitus (AHR 1.60, P=.03) and hypertension (AHR 1.25, P=.04). In contrast, men with hypercholesterolemia had a similar risk of ACM (AHR 0.68, P=.17) when compared with men with no comorbidity. Other factors associated with a significantly increased risk of ACM included age (AHR 1.09, P<.001), prostate-specific antigen level (AHR 1.25, P=.008), and Gleason score 8-10 disease (AHR 1.71, P=.003). Cardiovascular comorbidity did not impact the risk of PC-specific mortality. Conclusions: In addition to age and unfavorable PC prognostic factors, select CAD risk factors and sequelae are associated with an increased risk of ACM in men treated for PC. These comorbidity prognostic factors predict time courses of mortality from competing causes, which may be factored into the decision-making process when considering management options for PC in a given individual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-CAMPUS-I-04: Magnetic Resonance Imaging of An in Vitro 3D Tumor Model

Purpose: To investigate the use of an in vitro 3D tumor model (tumoroid) as a bio-phantom for repetitive and sequential magnetic resonance imaging (MRI) studies. Methods: The tissue engineered tumoroid comprised an artificial cancer mass (ACM) containing 30 million HT29 cancer cells seeded in a collagen type I matrix, whose density was increased by plastic compression (dry/wet weight=40%). The ACM was embedded in an uncompressed collagen gel that mimicked the tumor stroma, and the tumoroid was incubated for 24h before imaging. Images were acquired using the 1T ICON™ (Bruker Corporation, Billerica, MA) MRI scanner. T1 maps were calculated using an IR-RARE sequence (TE=12ms, TR=10000ms, 7 inversion times), while for T2 maps a MSME technique (TR=6000ms, 16 echoes) was used. T1 and T2 fittings were performed using a pixel-wise approach to produce relaxometric parametric maps. Results: The images acquired and corresponding T1 and T2 maps indicate contrast between the ACM and the stroma. T1 was 2500 and 2800ms, while T2 was 520 and 760ms, for the ACM and stroma respectively. The ACM construct was not homogenous and internal features were visible, which can be explained by local gradients of cell and/or collagen density. The viability of the cells was confirmed via confocal microscopy for several days after the imaging session, demonstrating the suitability of the tumoroid for sequential imaging studies. Conclusions: We have engineered a tumor model compatible with repetitive and sequential MRI. We found T1 and T2 contrast between the ACM and stroma using a pre-clinical MRI scanner. The model, which enables controllable cell and matrix densities, has potential for a wide range of applications in radiotherapy, such as to study tumor progression and to validate imaging biomarkers. Further work is necessary to understand the mechanisms behind the contrast achieved, and to correlate findings with biology and histology data.

60 APPLIED LIFE SCIENCES↗

Self-Organized Amorphous TiO2 Nanotube Arrays on Porous Ti Foam for Rechargeable Lithium and Sodium Ion Batteries

Self-organized amorphous TiO2 nanotube arrays (NTAs) were successfully fabricated on both Ti foil and porous Ti foam through electrochemical anodization techniques. The starting Ti foams were fabricated using ARCAM s Electron Beam Melting (EBM) technology. The TiO2 NTAs on Ti foam were used as anodes in lithium ion batteries; they exhibited high capacities of 103 Ahcm-2 at 10 Acm-2 and 83 Ahcm-2 at 500 Acm-2, which are two to three times higher than those achieved on the standard Ti foil, which is around 40 Ahcm-2 at 10 Acm-2 and 24 Ahcm-2 at 500 Acm-2, respectively. This improvement is mainly attributed to higher surface area of the Ti foam and higher porosity of the nanotube arrays layer grown on the Ti foam. In addition, a Na-ion half-cell composed of these NTAs anodes and Na metal showed a self-improving specific capacity upon cycling at 10 Acm-2. These results indicate that TiO2 NTAs grown on Ti porous foam are promising electrodes for Li-ion or Na-ion rechargeable batteries.

Bi, Zhonghe↗

Effect of electrolyte concentration on performance of supercapacitor carbon electrode from fibers of oil palm empty fruit bunches

Fibers of oil palm empty fruit bunches were used to produce self-adhesive carbon grains (SACG). The SACG green monoliths were carbonized in N{sub 2} environment at 800°C to produce carbon monoliths (CM) and the CM was CO{sub 2} activated at 800°C for 4 hour to produce activated carbon monolith electrodes (ACM). The physical properties of the CMs and ACMs were investigated using X-ray diffraction, field emission scanning electron microscopy and nitrogen adsorption-desorption. ACMs were used as electrode to fabricate symmetry supercapacitor cells and the cells which used H{sub 2}SO{sub 4} electrolyte at 0.5, 1.0 and 1.5 M were investigated using electrochemical impedance spectroscopy, cyclic voltammetry and galvanostatic charge-discharge standard techniques. In this paper we report the physical properties of the ACM electrodes and the effect of electrolyte concentration on the electrochemical properties the ACM electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Service Provider Agnostic Adaptive Coding and Modulation System Design

Commercial service providers (CSPs) are increasingly used to provide communications services to near-Earth science and exploration missions. CSPs commonly utilize modems that are designed to implement adaptive coding and modulation (ACM) in unique ways with modems from the same vendor. However, some missions cannot fly a matching vendor modem, either because the vendor only designs modems for terrestrial use, or the mission needs to fly a software defined radio. We present an ACM system design that allows missions to implement ACM on DVB-S2 compliant CSP links without needing to fly a modem from the same vendor the CSP uses. We implement and test our design in an emulated communications testbed. These tests demonstrate that our ACM system design can successfully adapt to link quality changes up to 6.12 dB/second.

Adaptive coding and modulation↗

Service Provider Agnostic Adaptive Coding and Modulation System Design

Commercial service providers (CSPs) are increasingly used to provide communications services to near-Earth science and exploration missions. CSPs commonly utilize modems that are designed to implement adaptive coding and modulation (ACM) in unique ways with modems from the same vendor. However, some missions cannot fly a matching vendor modem, either because the vendor only designs modems for terrestrial use, or the mission needs to fly a software defined radio. We present an ACM system design that allows missions to implement ACM on DVB-S2 compliant CSP links without needing to fly a modem from the same vendor the CSP uses. We implement and test our design in an emulated communications testbed. These tests demonstrate that our ACM system design can successfully adapt to link quality changes up to 6.12 dB/second.

Adaptive coding and modulation↗

Risk of All-Cause and Prostate Cancer-Specific Mortality After Brachytherapy in Men With Small Prostate Size

Background: Brachytherapy for prostate cancer can be technically challenging in men with small prostates ({<=}20 cc), but it is unknown whether their outcomes are different than those of men with larger prostates. Methods and Materials: We studied 6,416 men treated with brachytherapy in one of 21 community-based practices. Cox regression and Fine and Gray's regression were used to determine whether volume {<=}20 cc was associated with a higher risk of all-cause mortality (ACM) or prostate cancer-specific mortality (PCSM), respectively, after adjustment for other known prognostic factors. Results: 443 patients (6.9%) had a prostate volume {<=}20 cc. After a median follow-up of 2.91 years (interquartile range, 1.06-4.79), volume {<=}20 cc was associated with a significantly higher risk of ACM (adjusted hazard ratio = 1.33 [95% CI 1.08-1.65], p = 0.0085) with 3-year estimates of ACM for {<=}20 cc vs. >20 cc of 13.0% vs. 6.9% (p = 0.028). Only 23 men (0.36%) have died of prostate cancer, and no difference was seen in PCSM by volume (p = 0.4). Conclusion: Men with small prostates at the time of implant had a 33% higher risk of ACM, and the underlying cause of this remains uncertain. No increase in PCSM was observed in men with volume {<=}20cc, suggesting that a small prostate should not in itself be a contraindication for brachytherapy, but inasmuch as absolute rates of PCSM were small, further follow-up will be needed to confirm this finding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Androgen Deprivation Therapy on All-Cause Mortality in Men With High-Risk Prostate Cancer and a History of Congestive Heart Failure or Myocardial Infarction

Purpose: It is unknown whether the excess risk of all-cause mortality (ACM) observed when androgen deprivation therapy (ADT) is added to radiation for men with prostate cancer and a history of congestive heart failure (CHF) or myocardial infarction (MI) also applies to those with high-risk disease. Methods and Materials: Of 14,594 men with cT1c-T3aN0M0 prostate cancer treated with brachytherapy-based radiation from 1991 through 2006, 1,378 (9.4%) with a history of CHF or MI comprised the study cohort. Of these, 22.6% received supplemental external beam radiation, and 42.9% received a median of 4 months of neoadjuvant ADT. Median age was 71.8 years. Median follow-up was 4.3 years. Cox multivariable analysis tested for an association between ADT use and ACM within risk groups, after adjusting for treatment factors, prognostic factors, and propensity score for ADT. Results: ADT was associated with significantly increased ACM (adjusted hazard ratio [AHR] = 1.76; 95% confidence interval [CI], 1.32-2.34; p = 0.0001), with 5-year estimates of 22.71% with ADT and 11.62% without ADT. The impact of ADT on ACM by risk group was as follows: high-risk AHR = 2.57; 95% CI, 1.17-5.67; p = 0.019; intermediate-risk AHR = 1.75; 95% CI, 1.13-2.73; p = 0.012; low-risk AHR = 1.52; 95% CI, 0.96-2.43; p = 0.075). Conclusions: Among patients with a history of CHF or MI treated with brachytherapy-based radiation, ADT was associated with increased all-cause mortality, even for patients with high-risk disease. Although ADT has been shown in Phase III studies to improve overall survival in high-risk disease, the small subgroup of high-risk patients with a history of CHF or MI, who represented about 9% of the patients, may be harmed by ADT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Comorbidity on the Risk of Mortality in Men With Unfavorable-Risk Prostate Cancer Undergoing High-Dose Radiation Therapy Alone

Purpose: To explore whether a subgroup of men with unfavorable-risk prostate cancer (PC) exists in whom high-dose radiation therapy (RT) alone is sufficient to avoid excess PC death due to competing risk from cardiometabolic comorbidity. Methods and Materials: This was a cohort study of 7399 men in whom comorbidity (including congestive heart failure, diabetes mellitus, or myocardial infarction) was assessed and recorded with T1-3NxM0 PC treated with brachytherapy with or without neoadjuvant RT, October 1997 to May 2013 at a single providing institution. Cox and competing risks regression analyses were used to assess whether men with unfavorable–intermediate/high-risk versus favorable–intermediate/low-risk PC were at increased risk of PC-specific, all-cause, or other-cause mortality (PCSM, ACM, OCM), adjusting for number of comorbidities, age at and year of brachytherapy, RT use, and an RT treatment propensity score. Results: After a median follow-up of 7.7 years, 935 men died: 80 of PC and 855 of other causes. Among men with no comorbidity, PCSM risk (adjusted hazard ratio [AHR] 2.74 [95% confidence interval (CI) 1.49-5.06], P=.001) and ACM risk (AHR 1.30 [95% CI 1.07-1.58], P=.007) were significantly increased in men with unfavorable–intermediate/high-risk PC versus favorable–intermediate/low-risk PC, with no difference in OCM (P=.07). Although PCSM risk was increased in men with 1 comorbidity (AHR 2.87 [95% CI 1.11-7.40], P=.029), ACM risk was not (AHR 1.03 [95% CI 0.78-1.36], P=.84). Neither PCSM risk (AHR 4.39 [95% CI 0.37-51.98], P=.24) or ACM risk (AHR 1.43 [95% CI 0.83-2.45], P=.20) was increased in men with 2 comorbidities. Conclusions: To minimize death from PC, high-dose RT alone may be sufficient treatment in men with 2 or more cardiometabolic comorbidities and unfavorable–intermediate- and high-risk PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis of molybdenum nitrido complexes for triple-bond metathesis of alkynes and nitriles.

Complexes of the type N {triple_bond} Mo(OR){sub 3} (R = tertiary alkyl, tertiary silyl, bulky aryl) have been synthesized in the search for molybdenum-based nitrile-alkyne cross-metathesis (NACM) catalysts. Protonolysis of known N {triple_bond} Mo(NMe{sub 2}){sub 3} led to the formation of N {triple_bond} Mo(O-2,6-{sup i}Pr{sub 2}C{sub 6}H{sub 3}){sub 3}(NHMe{sub 2}) (12), N {triple_bond} Mo(OSiPh{sub 3}){sub 3}(NHMe{sub 2}) (5-NHMe{sub 2}), and N {triple_bond} Mo(OCPh{sub 2}Me){sub 3}(NHMe{sub 2}) (17-NHMe{sub 2}). The X-ray structure of 12 revealed an NHMe{sub 2} ligand bound cis to the nitrido ligand, while 5-NHMe{sub 2} possessed an NHMe{sub 2} bound trans to the nitride ligand. Consequently, 17-NHMe{sub 2} readily lost its amine ligand to form N {triple_bond} Mo(OCPh{sub 2}Me){sub 3} (17), while 12 and 5-NHMe{sub 2} retained their amine ligands in solution. Starting from bulkier tris-anilide complexes, N {triple_bond} Mo(N[R]Ar){sub 3} (R = isopropyl, tert-butyl; Ar = 3,5-dimethylphenyl) allowed for the formation of base-free complexes N {triple_bond} Mo(OSiPh3)3 (5) and N {triple_bond} Mo(OSiPh{sub 2}tBu){sub 3} (16). Achievement of a NACM cycle requires the nitride complex to react with alkynes to form alkylidyne complexes; therefore the alkyne cross-metathesis (ACM) activity of the complexes was tested. Complex 5 was found to be an efficient catalyst for the ACM of 1-phenyl-1-butyne at room temperature. Complexes 12 and 5-NHMe{sub 2} were also active for ACM at 75 C, while 17-NHMe{sub 2} and 16 did not show ACM activity. Only 5 proved to be active for the NACM of anisonitrile, which is a reactive substrate in NACM catalyzed by tungsten. NACM with 5 required a reaction temperature of 180 C in order to initiate the requisite alkylidyne-to-nitride conversion, with slightly more than two turnovers achieved prior to catalyst deactivation. Known molybdenum nitrido complexes were screened for NACM activity under similar conditions, and only N {triple_bond} Mo(OSiPh{sub 3}){sub 3}(py) (5-py) displayed any trace of NACM activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Large-Scale Vorticity Balance of the Antarctic Continental Margin in a Fine-Resolution Global Simulation

The depth-integrated vorticity budget of a global, eddy-permitting ocean/sea ice simulation over the Antarctic continental margin (ACM) is diagnosed to understand the physical mechanisms implicated in meridional transport. The leading-order balance is between the torques due to lateral friction, nonlinear effects, and bottom vortex stretching, although details vary regionally. Maps of the time-averaged depth-integrated vorticity budget terms and time series of the spatially averaged, depth-integrated vorticity budget terms reveal that the flow in the Amundsen, Bellingshausen, and Weddell Seas and, to a lesser extent, in the western portion of East Antarctica, is closer to an approximate topographic Sverdrup balance (TSB) compared to other segments of the ACM. Correlation and coherence analyses further support these findings, and also show that inclusion of the vorticity tendency term in the response (the planetary vorticity advection and the bottom vortex stretching term) increases the correlation with the forcing (the vertical net stress curl), and also increases the coherence between forcing and response at high frequencies across the ACM, except for the West Antarctic Peninsula. Finally, these findings suggest that the surface stress curl, imparted by the wind and the sea ice, has the potential to contribute to the meridional, approximately cross-slope, transport to a greater extent in the Amundsen, Bellingshausen, Weddell, and part of the East Antarctic continental margin than elsewhere in the ACM.

58 GEOSCIENCES↗

Exascale Programming Approaches for Accelerated Climate Modeling for Energy

The Accelerated Climate Modeling for Energy (ACME) program is a leading-edge climate and Earth system model designed to address the U.S. Department of Energy (DOE) mission needs. The ACME project involves collaboration between seven National Laboratories, the National Center for Atmospheric Research, four academic institutions, and one private-sector company. The ACME project funds ongoing efforts to ensure the model continues to make efficient use of DOE Leadership Computing Facilities (LCFs) in order to best address the three driving grand challenge science questions:Water cycle: How will more realistic portrayals of features important to the water cycle (resolution, clouds, aerosols, snowpack, river routing, land use) affect river flow and associated freshwater supplies at the watershed scale?Cryosphere systems: Could a dynamical instability in the Antarctic ice sheet be triggered within the next 40 years?Biogeochemistry: What are the contributions and feedbacks from natural and managed systems to current greenhouse gas fluxes, and how will those factors and associated fluxes evolve in the future?

Norman, Matthew↗

Evaluation of rotor-bearing system dynamic response to unbalance

The vibration environment within air conditioner rotating machinery referred to as an air cycle machine (ACM) was investigated to effectively increase ACM reliability. To assist in the selection of design changes which would result in improved ACM performance, various design modifications were incorporated into a baseline ACM configuration. For each design change, testing was conducted with the best balance achieveable (baseline) and with various degrees of unbalance. Relationships between unbalance (within the context of design changes) and the parameters associated with design goals were established. The results of rotor dynamics tests used to establish these relationships are presented.

Thaller, R. E.↗

Overview of C/C-SiC Composite Development for the Orion Launch Abort System

Past and present efforts by the authors to further understanding of the ceramic matrix composite (CMC) material used in the valve components of the Orion Launch Abort System (LAS) Attitude Control Motor (ACM) will be presented. The LAS is designed to quickly lift the Orion Crew Exploration Vehicle (CEV) away from its launch vehicle in emergency abort scenarios. The ACM is a solid rocket motor which utilizes eight throttleable nozzles to maintain proper orientation of the CEV during abort operations. Launch abort systems have not been available for use by NASA on manned launches since the last Apollo ]Saturn launch in 1975. The CMC material, carbon-carbon/silicon-carbide (C/C-SiC), is manufactured by Fiber Materials, Inc. and consists of a rigid 4-directional carbon-fiber tow weave reinforced with a mixed carbon plus SiC matrix. Several valve and full system (8-valve) static motor tests have been conducted by the motor vendor. The culmination of these tests was the successful flight test of the Orion LAS Pad Abort One (PA ]1) vehicle on May 6, 2010. Due to the fast pace of the LAS development program, NASA Marshall Space Flight Center assisted the LAS community by performing a series of material and component evaluations using fired hardware from valve and full ]system development motor tests, and from the PA-1 flight ACM motor. Information will be presented on the structure of the C/C-SiC material, as well as the efficacy of various non ]destructive evaluation (NDE) techniques, including but not limited to: radiography, computed tomography, nanofocus computed tomography, and X-ray transmission microscopy. Examinations of the microstructure of the material via scanning electron microscopy and energy dispersive spectroscopy will also be discussed. The findings resulting from the subject effort are assisting the LAS Project in risk assessments and in possible modifications to the final ACM operational design.

Allen, Lee R.↗

Simple processing via thermal treatment and catalyst infiltration to enhance nickel electrode performance for liquid alkaline water electrolyzers

Two simple processes for enhancing liquid alkaline water electrolyzer performance are demonstrated. Both enhance 3D Ni electrodes by introducing a micron-scale rough structure throughout the bulk of the electrode. Oxidation/reduction relies on a simple thermal treatment cycle to create surface roughening through the volumetric expansion during NiO formation and volume contraction during reduction back to Ni metal. Catalyst infiltration introduces a washcoat of additional metal particles throughout the electrode, by flooding the electrode with catalyst precursor and converting it to micron-scale particles via a reducing thermal treatment. Further, the largest improvement in performance (211mV at 1.8Acm -2 ) is observed for infiltrated NiFe-3x catalyst. For Fe-free Ni-only electrodes, oxidation/reduction provides a larger improvement (157 mV at 1.8Acm -2 ) than infiltrated Ni-3X (106mV at 1.8Acm -2 ). For both processes, the observed electrode surface structure and performance is quite sensitive to the thermal treatment temperature.

08 HYDROGEN↗

Effect of carbonization temperature on the physical and electrochemical properties of supercapacitor electrode from fibers of oil palm empty fruit bunches

Self-adhesive carbon grains (SACG) was prepared from fibers of oil palm empty fruit bunches. The SACG green monoliths were carbonized in N{sub 2} environment at 400, 500, 600 and 700°C to produce carbon monoliths labeled as CM1, CM2, CM3 and CM4 respectively. The CMs were activated in CO{sub 2} surrounding at 800°C for 1 hour to produce activated carbon monolith electrodes (ACM1, ACM2, ACM3 and ACM4). The physical properties of the CMs and ACMs were investigated using X-ray diffraction, field emission scanning electron microscopy (FESEM) and N{sub 2} adsorption-desorption isotherm techniques. ACMs were used as electrode to fabricate symmetry supercapacitor cells and the cells’ performances were investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD) standard techniques. In this paper we report the physical and electrochemical properties of the ACM electrodes by analyzing the influence of the carbonization temperature on these properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗