Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADIABATIC DEMAGNETIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗

A 100 micro Kelvin bolometer system for SIRTF

Progress toward a prototype of 100 mK bolometric detection system for the Space Infrared Telescope Facility (SIRTF) is described. Two adiabatic demagnetization refrigerators (ADR's) were constructed and used to investigate the capabilities necessary for orbital operation. The first, a laboratory ADR, demonstrated a hold time at 0.1 K of over 12 hours, with temperature stability approx. 3 micro-K RMS achieved by controlling the magnetic field. A durable salt pill and an efficient support system have been demonstrated. A second ADR, the SIRTF flight prototype, has been built and will be flown on a balloon. Techniques for magnetic shielding, low heat leak current leads, and a mechanical heat switch are being developed in this ADR. Plans for construction of 100 mK bolometers are discussed. Three important cosmological investigations which will be carried out by these longest wavelength SIRTF detectors are described.

Bernstein, G. M.↗

The cryogenic subsystem for the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility (AXAF)

The X-ray Spectrometer (XRS) instrument on the Advanced X-ray Astrophysics Facility (AXAF) will use X-ray detectors that operate at 0.1 K. The detectors will be maintained at 0.1 K by an Adiabatic Demagnetization Refrigerator (ADR) that operates inside a liquid helium dewar. The ADR rejects approximately 2 mW of heat to the stored liquid helium. With this low instrument heat load, the liquid helium dewar will have a long lifetime if the parasitic heat load on the helium from the surrounding warm facility is minimized. Spaceborne helium dewars typically use up to 3 vapor cooled shields to intercept the parasitic heat load. The XRS will add mechanical coolers to provide additional cooling to the outer vapor cooled shield. The cryogenic system consists of an ADR, a liquid helium dewar, mechanical coolers, and a thermal strap to connect the coolers to the dewar. The lifetime of the stored cryogen is calculated to be up to 5 years. This cryogenic system is described, with particular attention given to the dewar, mechanical cooler, and ADR design, testing, and trade studies. A breadboard ADR is presently being fabricated and tested. The status of the construction and testing of this breadboard will be described.

Castles, Stephen H.↗

Space Cryogenic Workshop, 8th, California Institute of Technology, Pasadena, July 31, Aug. 1, 1989, Proceedings

Recent advances in cryogenic technology for space applications are examined in reviews and reports. Topics addressed include very-low-force cooling contacts for the ISO cryostat cover, convective heat flow in space cryogenics plugs, liquid-acquisition devices for superfluid He transfer, and pressure drop in the SHOOT superfluid-He acquisition system. Consideration is given to a liquid-He vibration cryostat for space qualification tests, closed-cycle coolers for temperatures below 30 K, stress analysis down to liquid-He temperature, a cryogenic valve actuator, and a spaceborne He-3 refrigerator. Also discussed are an adiabatic-demagnetization refrigerator for SIRTF, rejection of waste heat from O liquefaction operations at a lunar O production plant, SHOOT flowmeter and pressure transducers, and space qualification of the ISO cryogenic rupture disks.

Source record↗

Helium 3/Helium 4 dilution cryocooler for space

Prototype dilution cryocoolers based on dilution refrigeration and adiabatic demagnetization refrigeration (ADR) cycles were designed, constructed, and tested. Although devices the devices did not operate as fully functional dilution cryocoolers, important information was gathered. The porous metal phase separator was demonstrated to operate in the -1-g configuration; this phase separation is the critical element in the He-3 circulation dilution cryocooler. Improvements in instrumentation needed for additional tests and development were identified.

Hendricks, John B.↗

Physicists make a difference in space cryogenics

An evaluation is made of space cryogenics technology development challenges in whose treatment the unique abilities of physicists have been notably valuable. In addition to such broad concerns as the quantum properties of superfluid He, the basic laws of thermodynamics and entropy, and quantization of such fields as those of phonons and magnons, productive efforts have been made by physicists in the basic principles of SQUIDs, magnetic shielding due to the Meissner effect in superconductors, adiabatic demagnetization, and dilution cooling of He-3 and He-4. These contributions will be of fundamental importance to the IR Telescope for Space and Advanced X-ray Astronomical Facility, which are currently under development.

Petrac, D.↗

Technology development program for the Space Infrared Telescope Facility (SIRTF) science instruments

A coordinated technology program for the Space Infrared Telescope Facility (SIRTF) is described. The program encompasses detector technology, cryogenic mechanisms technology, and an adiabatic demagnetization refrigerator. Discrete detectors, detector arrays, detector readouts, and testing of engineering models under simulated flight environment conditions are considered. Several focal planes will be optimized at a particular wavelength range to make up over 247,000 detector pixels from about 1.8 to 1000 microns.

Ramos, Ruben↗

A spaceworthy ADR - Recent developments

Recent developments concerning the performance and reliability of a spaceworthy adiabatic demagnetization refrigerator (ADR) for the AXAF X-ray spectrometer are considered. They include a procedure for growing the salt pill around a harness made up of 6080 gold-plated copper wires, a totally modular gas gap heat switch, and a suspension system utilizing Kevlar fibers.

Serlemitsos, Aristides T.↗

Space Cryogenics Workshop, 10th, Cleveland, OH, June 18-20, 1991, Proceedings

The present workshop on cryogenics discusses the anomalous on-orbit behavior of the Cosmic Background Explorer Dewar, the SHOOT orbital operations, cooling options for Astromag, and space IR telescope facility mission and cryogenic design. Attention is given to the design of a spaceworthy adiabatic demagnetization refrigerator, the evaluation of metal hydride compressors for applications in Joule-Thomson cryocoolers, diaphragm Stirling cryocooler developments, and a computer simulation model for Stirling refrigerators. Topics addressed include low-gravity thermal stratification of liquid helium on SHOOT, a screening program to select a resin for gravity probe-B composites, a simplified generic cryostat thermal model for predicting cryogen mass and lifetime, and the effect of gas mass flux on cryogenic liquid jet breakup. Also discussed are damping criteria for thermal acoustic oscillations in slush and liquid hydrogen systems, an STS-based cryogenic fluid management experiment, and the design and testing of a cryogenic mixer pump.

Source record↗

A flightworthy ADR for use in the AXAF/XRS

NASA-Goddard has undertaken the development of an adiabatic demagnetization refrigerator (ADR) for cooling the detectors of the Advanced X-ray Astrophysical Facility's X-ray Spectrometer (XRS) to the requisite 0.065 K-operation temperature. The XRS ADR's intricate thermal bus system furnished excellent thermal conductance for both the low parasitic heat leak heat switch during the magnetization cycle, and the detectors during low temperature operation. Attention is given to the ADR's operating principles, construction, and suspension system.

Serlemitsos, Aristides T.↗

A two-stage magnetic refrigerator for astronomical applications with reservoir temperatures above 4 K

We propose a novel adiabatic demagnetization refrigerator (ADR) to produce temperatures as low as 100 mK starting from a high temperature reservoir between 4 and 8 K. The high temperature reservoir for the ADR can be provided by a mechanical cooler or an unpumped liquid helium bath. This refrigerator can be used to cool bolometric infrared detectors for low background astronomy from mountain tops, balloons or satellites as well as to cool cryogenic x-ray detectors. The two-stage ADR consists of a single magnet with a paramagnetic chromic-cesium-alum (CCA) salt pill to produce the low temperature and paramagnetic gadolinium-gallium-garnet (GGG) as the first stage to intercept heat from the high temperature reservoir. Thermal contact between the paramagnets and the reservoir during magnetization is made with a mechanical heat switch. The ADR is suspended with Kevlar chords under tension for high mechanical stiffness and low parasitic heat leak. In a single cycle, the ADR maintains a temperature of 100 mK for 10 to 100 hours. This time depends strongly on the magnetic field and reservoir temperature but not on the volume of the paramagnetic material as long as the heat leak is dominated by the suspension.

Hagmann, C.↗

A broadband THz receiver for low background space applications

We have developed a sensitive bolometric receiver for low background space applications. In a 10 percent bandwidth at 1 THz, this receiver is approximately 100 times more sensitive than a quantum limited heterodyne receiver with a 1 GHz IF bandwidth. This receiver is designed to be used for the long wavelength band (200-700 microns) in the MIPS instrument on NASA's SIRTF satellite. The bolometers are cooled to 100 mK by an adiabatic demagnetization refrigerator. Roughly 60 g of cesium chrome alum salt is partially demagnetized to 100 mK, followed by a slow regulated downramp to compensate for the heat leak. The hold time of the ADR system is about 18 hours with a temperature stability of delta T(sub rms) approx. equals 10 micro-K. The composite bolometers have electrical responsivities of 10(exp 9)V/W and electrical NEP's of about 3x10(exp -17) W/square root of Hz. The bolometer signals are read out by JFET preamplifiers located on the helium plate and operated at 120 K. We have addressed a number of space qualification issues, such as the development of an analog magnet controller, construction of a cryogenic shake-table for bolometers and selection of the paramagnetic salt CCA which can survive a bakeout at 50 C. The receiver is scheduled to be flown in the spring of 1992 on a balloon telescope. This flight has a dual purpose. One is to provide realistic test of the capabilities of the new receiver. The other is to search for anisotropies in the cosmic microwave background on scales of a few degrees.

Hagmann, C.↗

The AXAF/XRS ADR - Engineering model

A spaceworthy Adiabatic Demagnetization Refrigerator is under development at Goddard Space Flight Center as part of the X-Ray Spectrometer (XRS), an instrument on the Advanced X-ray Astrophysics Facility (AXAF). XRS will employ an array of 32 microcalorimeters capable of detecting X-rays in the energy range of 0.3 - 10 keV. In order to achieve a desired resolution of 12 eV, these detectors must be operated at a temperature of 0.065 - 0.100 K. An ADR must be used to cool these detectors in space. A breadboard model was designed and built less than two years ago, and provided excellent results. We are presently at the development stage of the engineering model. Several changes have been made to the original design in order to improve the efficiency of the ADR, to reduce its weight, and to strengthen the salt pill suspension system so that the ADR can survive launch loads and have low sensitivity to microphonic inputs. We shall report on the results of these changes; what worked and what did not.

Serlemitsos, Aristides T.↗

The X-ray Spectrometer - A cryogenic instrument on the Advanced X-ray Astrophysics Facility

The X-ray Spectrometer (XRS) is an instrument on the Advanced X-ray Astrophysics Facility (AXAF), the third of NASA's Great Observatories scheduled for launch in 1998. The XRS detectors have a resolution of approximately 10 eV over the range 0.3 - 10 keV. To achieve this resolution, the detectors are maintained at or below 0.1 Kelvin using an adiabatic demagnetization refrigerator inside a superfluid helium dewar. In addition, split-Stirling-cycle mechanical coolers are used to extend the anticipated on-orbit helium lifetime to a minimum of 4 years. This paper describes the challenges of developing this hybrid cryogenic system and presents an overview of the current design of the system.

Breon, Susan R.↗

The AXAF/XRS test dewar - A versatile design

The X-Ray Spectrometer (XRS) to be flown on the Advanced X-ray Astrophysics Facility (AXAF) consists of an array of microcalorimeters and an Adiabatic Demagnetization Refrigerator (ADR). The ADR provides an operating temperature of 0.065 to 0.100 K. To support extensive development testing of the ADR and the detector array, a test dewar has been designed and built that surpasses specification requirements. Pumping on the liquid helium bath with a 47 l/s pump, we have achieved temperatures lower than 1.5 K with a hold time in excess of 72 hrs. The dewar can be operated without liquid nitrogen with a hold time of 36 hrs. This feature was incorporated in the design because boiling nitrogen may introduce microphonic noise to the detectors. To further reduce the susceptibility to microphonic vibration a unique suspension system utilizing Kevlar fibers was devised which provides both translational and rotational rigidity to the detector mount. Finally, the dewar is very manageable and may be rotated by only one person.

Weintz, Karl F.↗

5-year lifetime hybrid superfluid helium dewar for the AXAF X-Ray Spectrometer (XRS)

The focal plane of the AXAF X-Ray Spectrometer requires an operating temperature of 0.1 K with a mission lifetime of 5 yrs. This demanding task is accomplished with a hybrid cryogenic subsystem consisting of mechanical coolers, a superfluid helium dewar and an adiabatic demagnetization refrigerator. By using mechanical coolers to remove heat from the dewar outer vapor-cooled shield, a 5-yr lifetime is achievable with only a 483-liter tank. This approach takes advantage of flight-proven, high-performance dewar technology and recent success in the development of split, Stirling-cycle mechanical coolers. Although the dewar design principles are similar to those used previously, parasitic heat flow is reduced to a new level by an optimized tension strap support system and careful attention to insulation system details. The benefit of the mechanical coolers is maximized by dewar interface design features that minimize parasitic heating and thermal impedance of the coupling. The dewar design and thermal performance analysis are discussed. Helium lifetime sensitivities and the effects of mechanical cooler failures are predicted.

Nieczkoski, Stephen J.↗

The South Pole Imaging Fabry Perot Interferometer (SPIFI)

The design and construction of the South Pole imaging Fabry-Perot interferometer (SPIFI) is reported. The SPIFI is a direct detection imaging spectrometer for use in the far infrared and submillimeter bands accessible to the 1.7 m telescope at the South Pole, and in the submillimeter bands accessible to the 15 m James Clerk Maxwell Telescope (JCMT), HI. It employs a 5 x 5 silicon bolometer array and three cryogenic Fabry Perot interferometers in series in order to achieve velocity resolutions of between 300 km/s and 30 km/s over the entire field of view with a resolution of up to 1 km/s at the center pixel. The scientific justification for the instrument is discussed, considering the spectral lines available to SPIFI. The optical path, the cryogenic Fabry-Perot, the adiabatic demagnetization refrigerator and the detector array are described. The instrument's sensitivity is presented and compared with coherent systems.

Stacey, G. J.↗

The Third Flight Magnet

A self-shielded superconducting magnet was designed for the NASA Goddard Space Flight Center Adiabatic Demagnetization Refrigerator Program. This is the third magnet built from this design. The magnets utilize Cryomagnetics' patented ultra-low current technology. The magnetic system is capable of reaching a central field of two tesla at slightly under two amperes and has a total inductance of 1068 henries. This final report details the requirements of the magnet, the specifications of the resulting magnet, the test procedures and test result data for the third magnet (Serial # C-654-M), and recommended precautions for use of the magnet.

McGhee, R. Wayne↗