Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR INLET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Probing Heterogeneous Degradation of Catalyst in PEM Fuel Cells under Realistic Automotive Conditions with Multi-Modal Techniques

The heterogeneity of polymer electrolyte fuel cell catalyst degradation is studied under varied relative humidity and types of feed gas. Accelerated stress tests (ASTs) are performed on four membrane electrode assemblies (MEAs) under wet and dry conditions in an air or nitrogen environment for 30 000 square voltage cycles. The largest electrochemically active area loss is observed for MEA under wet conditions in a nitrogen gas environment AST due to constant upper potential limit of 0.95 V and significant water content. The mean Pt particle size is larger for the ASTs under wet conditions compared to dry conditions, and the Pt particle size under land is generally larger than under the channel. Observations from ASTs in both conditions and gas environments indicate that water content promotes Pt particle size growth. ASTs under wet conditions and an air environment show the largest difference in Pt particle size growth for inlet versus outlet and channel versus land, which can be attributed to larger water content at outlet and under land compared to inlet and under channel. From X-ray fluorescence experiments Pt particle size increase is a local phenomenon as Pt loading remains relatively uniform across the MEA.

25 ENERGY STORAGE↗

Dynamics of multilayer Rayleigh–Taylor instability at moderately high Atwood numbers

This paper investigates the multilayer Rayleigh–Taylor instability (RTI) using statistically stationary experiments conducted in a gas tunnel. Employing diagnostics such as particle image velocimetry (PIV) and planar laser induced fluorescence (PLIF), we make simultaneous velocity–density measurements to study how dynamics and mixing are linked in this variable density flow. Experiments are conducted in a newly built, blow-down three-layer gas tunnel facility. Mixing between three gas streams is studied, where the top and bottom streams are comprised of air, and the middle stream is an air–helium mixture. Shear is minimized between these streams by matching their inlet velocities. The four experimental conditions investigated here consist of two different density ratios (Atwood numbers 0.3 and 0.6), each investigated at two instability development times (or equivalently, two streamwise locations), and all experiments are with the same middle stream thickness of 3 cm. The growth of the middle layer is measured using laser-based planar Mie scattering visualization. The mixing width is found to grow linearly with time at late times. Various quantitative measures of molecular mixing indicate a very high degree of molecular mixing at late times in the multilayer RTI flow. The vertical turbulent mass flux $a_y$ is calculated. In addition to mostly negative values of $a_y$ , typical of buoyancy-dominated flows due to negative correlation between velocity and density fluctuations, positive regions are also observed in profiles of $a_y$ due to entrainment and erosion at the lower edge of the mixing region. Global energy budgets are calculated for the multilayer RTI flow at late times and it is found that the majority of potential energy released has been dissipated due to viscous effects, and a large value of mixing efficiency ( $\sim$ 60 %) is observed.

Mechanics↗

Data From Experiments on Bubbling Fluidization of Zeolite in a Rectangular Bubbling Fluidized Bed

Fluidization experiments were conducted in a lab-scale rectangular bubbling fluidized bed with the objective of generating a high-quality dataset for model validation and artificial intelligence/machine learning (AI/ML) training. Zeolite was chosen as the bed material, and the fluidizing medium was air as supplied by a compressor. Three different flow rates at the inlet were chosen such that the particles were fluidized but not elutriated from the system. The test matrix involved randomization and replicates to provide uncertainty estimates as well as four different batches of zeolite as the bed material. The quantities of interest obtained from this study were statistics of differential pressures, interface heights, and particle velocities. Considering all the components of the elaborate test plan, the results obtained were consistent and reproducible. Characterization tests were performed to estimate particle properties including size, density, coefficient of friction, coefficient of restitution, and minimum fluidization velocity. In addition, the angle of repose from granular discharge experiments has been reported to account for rolling friction, though its effect on the overall process is expected to be negligible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat release surrogates for NH 3 /H 2 /N 2 –air premixed flames

The present study investigates the performance of NH, NH 2 , O-atom, and H-atom as heat release rate (HRR) surrogates for NH 3 /H 2 /N 2 –air premixed flame through simulations. The simulations are conducted across different pressures, reactant inlet temperatures, fuel blend compositions, and equivalence ratios. Cantera is used to simulate one-dimensional (1D) freely propagating flames to investigate the spatial correlations of the species with the HRR. PeleLMeX, a low-Mach direct numerical simulation (DNS) code with Adaptive Mesh Refinement (AMR), is used to simulate two-dimensional (2D) flame-vortex interactions to investigate the temporal correlations including stretch effects. Three different mechanisms (Jiang et al. 2020; Glarborg et al. 2018; Okafor et al. 2018) were considered in the 1D flame simulations, whereas only the Jiang mechanism was considered in the flame-vortex simulations. The HRR surrogate performance for the 2D flames is evaluated at two different locations: (1) the centerline and (2) the flame cusp. The cusp is defined as the region in the flame front with the greatest curvature and the centerline encounters the highest tangential strain rate. The 1D flame results suggest that, although there is not uniformly good spatial correlation for HRR across all flame conditions, NH is the best overall as a HRR surrogate for laminar flames. The 2D flame results, however, suggest that O-atom and H-atom have satisfactory temporal correlations at different conditions—the former for rich flames, the latter for high-pressure flames. Furthermore, these simulations provide guidance to experimental measurements of surrogate HRR markers in unsteady multi-dimensional flames using laser diagnostics to detect species such as NH, O-atom, and H-atom.

Ammonia↗

Hydrogen-powered Electrochemically-driven CO 2 Removal from Air Containing 400 to 5000 ppm CO 2

The performance of a hydrogen-powered, electrochemically-driven CO 2 separator (EDCS) was demonstrated at cathode inlet CO 2 concentrations from 400 ppm to 5,000 ppm. The impact of current density and CO 2 concentration were evaluated to predict operating windows for various applications. The single-cell data was used to scale a 100 cm 2 , multi-cell stack using a shorted-membrane design for four applications: direct air capture (DAC), hydroxide exchange membrane fuel cell (HEMFC) air pretreatment, submarine life support, and space habitation. For DAC, a 339-cell EDCS stack (7.7 L, 17 kg) was projected to remove 1 tonne CO 2 per year. The addition of the EDCS in HEMFC systems would result in nearly a 30% increase in volume, and therefore further improvements in performance would be necessary. A module containing five 338-cell EDCS stacks (38 L, 85 kg) in parallel can support a 150 person crew at 2.1% of the volume of the liquid amine system employed in submarines. For space habitation, a 109-cell EDCS stack (3.2 L, 10 kg) is adequate for 6 crewmembers, and is less than 1% the size and 5% the weight of the current CO 2 removal system installed on the International Space Station.

25 ENERGY STORAGE↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Gas turbine combustion section having an integrated fuel cell assembly

A combustion section defines an axial direction, a radial direction, and a circumferential direction. The combustion section includes a casing that defines a diffusion chamber. A combustion liner is disposed within the diffusion chamber and defines a combustion chamber. The combustion liner is spaced apart from the casing such that a passageway is defined between the combustion liner and the casing. A fuel cell assembly is disposed in the passageway. The fuel cell assembly includes a fuel cell stack having a plurality of fuel cells each extending between an inlet end and an outlet end. Each fuel cell of the plurality of fuel cells includes an air channel and a fuel channel each fluidly coupled to the combustion chamber.

Hong, Seung-Hyuck↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Development of A Microsampler for Aerial Platform on Collection of Aerosol Particles

A microsampler for aerosol particles was designed and evaluated in the laboratory for dry (no condensed water) and wet (foggy, misty, or rainy) air conditions. Computational Fluid Dynamics (CFD) results suggested a design that provided a higher sampling efficiency with minimal inlet loss. The microsampler was experimentally evaluated using fluorescent Polystyrene Latex (PSL) particles at four nominal sizes. The experimental results at the four PSL particle sizes agree reasonably well with the collection efficiencies predicted by CFD. We found no impacts on the collection efficiency of the microsampler at conditions under 80% Relative Humidity (RH). However, when condensed water exists, significant biases on the collection efficiencies were found suggesting this microsampler should not be used in the condition where there was condensed water in the atmosphere, e.g., foggy, misty, and rainy conditions.

54 ENVIRONMENTAL SCIENCES↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

FWP FEAA149: “Next Generation Environmental Barrier Coatings”

Environmental barrier coatings (EBCs) are required coatings for utilization of SiC/SiC ceramic matrix composite (CMC) components in gas turbines, where the EBC represents the life-limiting factor for such components. EBC/CMC systems have shown success in aero-engine applications with increased turbine inlet temperatures and improved efficiencies, which are achieved through higher temperature stability, lower density, and decreased reliance on cooling air compared to traditional superalloys. While industrial gas turbines (IGTs) do not currently utilize SiC/SiC CMCs, the current shift towards low-carbon or carbon-free fuel sources for power generation could result in a need for EBC/CMC components with higher temperature capabilities. In this work, three tasks were outlined to improve understanding of EBC lifetimes to encourage use in IGTs with carbon-free fuel such as hydrogen: 1. Define the bond coating oxidation kinetics and EBC failure criteria, 2. Measure thermal expansion coefficients of each layered material, and 3. Perform advanced characterization and modeling to assess EBC lifetimes. Cyclic steam oxidation tests were conducted on various EBC/Si/SiC chemistries and EBC/SiC architectures to define substrate oxidation kinetics and EBC failure modes. An open-source code was developed to quantify the undulating thermally grown oxide thickness with thousands of measurements from specimen cross-section images. Bond coating oxidation kinetics were determined and used to develop a kinetic and thermodynamic model for predicting EBC lifetimes. High-temperature Raman spectroscopy was utilized for determining the SiO 2 thermally grown oxide phase transformation as the life-limiting feature for EBCs. Model efforts supported the claim that the SiO 2 phase transformation causes elevated stress during thermal cycling with associated cracking that decreases the adhesion strength of the EBC, eventually resulting in coating spallation. The finite element model subroutine will be made publicly available upon internal review. Further development of an EBC lifetime model for IGTs involves definition of a critical SiO 2 thickness for EBC spallation and must also consider both environmental (gas velocity, pressure, etc.) and specimen (EBC dopants, layer architectures, etc.) effects into predicted bond coating oxidation kinetics for long-lifetime components.

36 MATERIALS SCIENCE↗

Aero-Thermal Characterization of Accelerating and Diffusing Passages Downstream of Rotating Detonation Combustors

Cycle benefits of rotating detonation engines show up to five percentage points of efficiency gain for low-pressure ratio engines. An optimal integration between the combustor and the turbine needs to be guaranteed to realize this potential gain. The rotating detonation combustor (RDC) exhausts transonic flow with shocks rotating at frequencies ranging from a few to tens of kilohertz depending on the number of present waves. Hence, the turbine design requires precise knowledge of the fluctuations and losses downstream of the combustor. This paper focuses on the quantification of fluctuations and losses for accelerating and diffusing passages. The analysis of the combustor is performed via reactive unsteady Reynolds Averaged Navier-Stokes (URANS) simulations. The unsteady RANS equations are solved via CFD++ from Metacomp with a one-step reaction mechanism for an H2-air mixture. The resolving of the boundary layer is achieved with a structured mesh of around 36 million cells. Inlet pressure of 10 bar and two different back pressures are applied to the combustor to model the interconnection with downstream turbines. Finally, we present and assess a methodology to reduce the computational time to model these passages ten times.

Braun, James↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct high-altitude observations of 2-methyltetrols in the gas- and particle phase in air masses from Amazonia

We present direct observations of 2-methyltetrol (C 5 H 12 O 4 ) in the gas- and particle phase from the deployment of a Filter Inlet for Gases and Aerosols coupled to a Time-of-Flight Chemical Ionization Mass Spectrometer (FIGAERO-CIMS) during the Southern Hemisphere High Altitude Experiment on Particle Nucleation and Growth (SALTENA), which took place between December 2017 and June 2018 at the high-altitude Global Atmosphere Watch station Chacaltaya (CHC) located at 5240 m a s l in the Bolivian Andes. 2-Methyltetrol signals were dominant in a factor resulting from Positive Matrix Factorization (PMF) identified as influenced by Amazon emissions. We combine these observations with investigations of isoprene oxidation chemistry and uptake in an isolated deep convective cloud in the Amazon using a photochemical box model with coupled cloud microphysics and show that, likely, 2-methyltetrol is taken up by hydrometeors or formed in situ in the convective cloud, and then transported in the particle phase in the cold environment of the Amazon outflow and to the station, where it partially evaporates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Experimental and Numerical Investigation of Internal Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array and Single-Jet Impingement

Over the past decade, the drive to reduce greenhouse gas emissions and to increase thermal efficiency for turbomachinery has invigorated the application of supercritical carbon dioxide (sCO2) power cycles for energy generation. Compared to the industry standard air cycles, sCO2 applications hold the potential for several advantages, including higher efficiencies, smaller footprints, and zero greenhouse gas emissions. However, like any turbomachinery application, the turbine inlet temperature must increase to increase thermal efficiency. This introduces the need for internal cooling features to avoid material failure as operating conditions rise. Two standard features include pin fin turbulators in the trailing edge and jet impingement in the airfoil's leading edge. Over the past several decades, these features have been the subject of extensive research. However, the move to the sCO2 operating environment creates the need to re-visit these features to quantify the heat transfer capabilities within this supercritical cooling environment. The first objective of this paper is to discuss the development of the experimental demonstration for internal heat transfer testing at 200 bar and 400 Celsius, which sits well within the CO2 supercritical region. Next, the heat transfer for pin fin turbulators and single-jet impingement in the sCO2 environment is compared to existing air data-derived correlations to quantify any deviations from literature correlations. Finally, the experimental process aims to validate internal cooling conjugate heat transfer numerical simulations for sCO2 turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp↗