Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANALOG PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

JSATS Detector Field Manual

The Juvenile Salmon Acoustic Telemetry System (JSATS) Detector is a software and hardware system that captures JSATS Acoustic Micro Transmitter (AMT) signals. The system uses hydrophones to capture acoustic signals in the water. This analog signal is then amplified and processed by the Analog to Digital Converter (ADC) and Digital Signal Processor (DSP) board in the computer. This board digitizes and processes the acoustic signal to determine if a possible JSATS tag is present. With this detection, the data will be saved to the computer for further analysis. This document details the features and functionality of the JSATS Detector software. The document covers how to install the software, setup and run the detector software. The document will also go over the raw binary waveform file format and CSV files containing RMS values

47 OTHER INSTRUMENTATION↗

Ultraviolet digital holographic microscopy (DHM) of micron-scale particles from shocked Sn ejecta

A cloud of very fast, O (km/s), and very fine, O (µm), particles may be ejected when a strong shock impacts and possibly melts the free surface of a solid metal. To quantify these dynamics, this work develops an ultraviolet, long-working distance, two-pulse Digital Holographic Microscopy (DHM) configuration and is the first to replace film recording with digital sensors for this challenging application. A proposed multi-iteration DHM processing algorithm is demonstrated for automated measures of the sizes, velocities, and three-dimensional positions of non-spherical particles. Ejecta as small as 2 µm diameter are successfully tracked, while uncertainty simulations indicate that particle size distributions are accurately quantified for diameters ≥4 µm. These techniques are demonstrated on three explosively driven experiments. Measured ejecta size and velocity statistics are shown to be consistent with prior film-based recording, while also revealing spatial variations in velocities and 3D positions that have yet to be widely investigated. Having eliminated time-consuming analog film processing, the methodologies proposed here are expected to significantly accelerate future experimental investigation of ejecta physics.

47 OTHER INSTRUMENTATION↗

Deciphering Charge Transfer Processes in Transition Metal Complexes from the Perspective of Ultrafast Electronic and Nuclear Motions

Chemical transformations in charge transfer states result from the interplay between electronic dynamics and nuclear reorganization along excited-state trajectories. Here, in this study, we investigate the ultrafast structural dynamics following photoinduced electron transfer from the metal-metal-to-ligand charge transfer state of an electron donor, a Pt dimer complex, to a covalently linked electron acceptor group using ultrafast time-resolved wide-angle X-ray scattering and optical transient absorption spectroscopy methods to disentangle the interdependence of the excited-state electronic and nuclear dynamics. Following photoexcitation, Pt-Pt bond formation and contraction takes up to 1 ps, much slower than the corresponding process in analogous complexes without electron acceptor groups. Because the Pt-Pt distance change is slow with respect to excited-state electron transfer, it can affect the rate of electron transfer. These results have potential impacts on controlling electron transfer rates via structural alterations to the electron donor group, tuning the charge transfer driving force.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating and Optimizing the Lysate-Based Expression of Nonribosomal Peptide Synthetases Using a Reporter System

Lysate-based cell-free expression (CFE) systems are accessible platforms for expressing proteins that are difficult to synthesize in vivo, such as nonribosomal peptide synthetases (NRPSs). NRPSs are large (>100 kDa), modular enzyme complexes that synthesize bioactive peptide natural products. This synthetic process is analogous to transcription/translation (TX/TL) in lysates, resulting in potential resource competition between NRPS expression and NRPS activity in cell-free environments. Moreover, CFE conditions depend on the size and structure of the protein. Here, a reporter system for rapidly investigating and optimizing reaction environments for NRPS CFE is described. This strategy is demonstrated in E. coli lysate reactions using blue pigment synthetase A (BpsA), a model NRPS, carrying a C-terminal tetracysteine (TC) tag which forms a fluorescent complex with the biarsenical dye, FlAsH. A colorimetric assay was adapted for lysate reactions to detect the blue pigment product, indigoidine, of cell-free expressed BpsA-TC, confirming that the tagged enzyme is catalytically active. An optimized protocol for end point TC/FlAsH complex measurements in reactions enables quick comparisons of full-length BpsA-TC expressed under different reaction conditions, defining unique requirements for NRPS expression that are related to the protein’s catalytic activity and size. Importantly, these protein-dependent CFE conditions enable higher indigoidine titer and improve the expression of other monomodular NRPSs. Notably, these conditions differ from those used for the expression of superfolder GFP (sfGFP), a common reporter for optimizing lysate-based CFE systems, indicating the necessity for tailored reporters to optimize expression for specific enzyme classes. In conclusion, the reporter system is anticipated to advance lysate-based CFE systems for complex enzyme synthesis, enabling natural product discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical proton-coupled electron transfer: Beyond the golden rule

Electrochemical proton-coupled electron transfer rate constant expressions that interpolate between the golden rule and solvent-controlled limits are derived. These expressions include the effects of solvent dynamics and thus are applicable for a wide range of vibronic couplings and solvent relaxation times. The golden rule limit is defined in terms of weak vibronic coupling and fast solvent relaxation, and the solvent-controlled limit is defined in terms of strong vibronic coupling and slow solvent relaxation. In the golden rule limit, the rate constant is proportional to the square of the vibronic coupling and is independent of the solvent relaxation time. In the solvent-controlled limit, the rate constant is independent of the vibronic coupling and increases as the solvent relaxation time decreases. The interconversion between the solvent-controlled and golden rule limits can be induced by altering the proton donor-acceptor mode frequency and the overlap between the reactant and product proton vibrational wave functions, as well as the electronic coupling, the solvent relaxation time, and the overpotential. The kinetic isotope effect behaves differently in the solvent-controlled and golden rule limits and thus provides a unique probe for characterizing electrochemical proton-coupled electron transfer processes. The analogous rate constant expressions for electrochemical electron transfer and homogeneous proton-coupled electron transfer are also presented. The impact of electrode overpotential, solvent relaxation time, and proton donor-acceptor mode frequency on the rate constants are analyzed for model systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Memristive behavior in a junctionless flash memory cell

We report charge storage based memristive operation of a junctionless thin film flash memory cell when it is operated as a two terminal device by grounding the gate. Unlike memristors based on nanoionics, the presented device mode, which we refer to as the flashristor mode, potentially allows greater control over the memristive properties, allowing rational design. The mode is demonstrated using a depletion type n-channel ZnO transistor grown by atomic layer deposition (ALD), with HfO{sub 2} as the tunnel dielectric, Al{sub 2}O{sub 3} as the control dielectric, and non-stoichiometric silicon nitride as the charge storage layer. The device exhibits the pinched hysteresis of a memristor and in the unoptimized device, R{sub off}/R{sub on} ratios of about 3 are presented with low operating voltages below 5 V. A simplified model predicts R{sub off}/R{sub on} ratios can be improved significantly by adjusting the native threshold voltage of the devices. The repeatability of the resistive switching is excellent and devices exhibit 10{sup 6 }s retention time, which can, in principle, be improved by engineering the gate stack and storage layer properties. The flashristor mode can find use in analog information processing applications, such as neuromorphic computing, where well-behaving and highly repeatable memristive properties are desirable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE CORRELATION BETWEEN X-RAY LINE IONIZATION AND OPTICAL SPECTRAL TYPES OF THE OB STARS

Marked correlations are reported between the ionization of the X-ray line spectra of normal OB stars, as observed by the Chandra X-Ray Observatory, and their optical spectral types. These correlations include the progressive weakening of the higher ionization relative to the lower ionization X-ray lines with advancing spectral type, and the similarly decreasing intensity ratios of the H-like to He-like lines of the alpha ions. These relationships were not predicted by models, nor have they been clearly evident in astrophysical studies of a few objects; rather, they have emerged from morphological analysis of an adequate (albeit still small) sample, from which known peculiar objects such as magnetic stars and very rapid rotators have been isolated to reveal the normal trends. This process is analogous to that which first demonstrated the strong relationships between the UV wind profiles and the optical spectral types of normal OB stars, which likely bear a physical as well as a historical connection to the present X-ray results. Since the optical spectral types are calibrated in terms of fundamental stellar parameters, it follows that the winds and X-ray spectra are determined by the latter. These observations provide strong guidance for further astrophysical modeling of these phenomena.

79 ASTRONOMY AND ASTROPHYSICS↗

Focused-helium-ion-beam blow forming of nanostructures: radiation damage and nanofabrication

Targeted irradiation of nanostructures by a finely focused ion beam provides routes to improved control of material modification and understanding of the physics of interactions between ion beams and nanomaterials. Here, we studied radiation damage in crystalline diamond and silicon nanostructures using a focused helium ion beam, with the former exhibiting extremely long-range ion propagation and large plastic deformation in a process visibly analogous to blow forming. We report significant dependence of damage morphology on material, geometry, and irradiation conditions (ion dose, ion energy, ion species, and location). In this work, we suggest that our approach and findings will not only improve the understanding of radiation damage in isolated nanostructures, but will also support the design of new engineering materials and devices for current and future applications in nanotechnology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Dissociation dynamics of ion-pair states of Cl{sub 2} at principal quantum numbers beyond 1500

Long-lived ion-pair states of Cl{sub 2} have been observed by delayed pulsed-field ionization in the vicinity of the Cl{sup -}({sup 1}S{sub 0})+Cl{sup +}({sup 3}P{sub 2}) dissociation threshold following single-photon excitation from the X {sup 1}{Sigma}{sub g}{sup +}(v=0) ground state with a tunable vacuum-ultraviolet laser. The field-ionization spectra reveal a series of resonances corresponding to ion-pair states with effective principal quantum number n* between 1858 and 1876 belonging to a series converging to the Cl{sup -}({sup 1}S{sub 0})+Cl{sup +}({sup 3}P{sub 0}) dissociation threshold. These states are observed by forced predissociation into the Cl{sup -}({sup 1}S{sub 0})+Cl{sup +}({sup 3}P{sub 2}) ion-pair channel. This process is the ion-pair analog of the process of forced autoionization observed in Rydberg states. The analysis of the spectra and of the field-ionization behavior provides information on the couplings between the relevant ionization and dissociation channels and has enabled the determination of the ion-pair dissociation threshold [E{sub IPD}(Cl{sup -}({sup 1}S{sub 0})+Cl{sup +}({sup 3}P{sub 2}))=95 449.8{+-}1.0 cm{sup -1}] and of the dissociation energies of Cl{sub 2} [D{sub 0}(X {sup 1}{Sigma}{sub g}{sup +})=19 998.4{+-}1.1 cm{sup -1}] and Cl{sub 2}{sup +} [D{sub 0}(X{sup +} {sup 2}{Pi}{sub u})=31 942.1{+-}1.5 cm{sup -1}].

74 ATOMIC AND MOLECULAR PHYSICS↗

Plasmon production from dark matter scattering

We present a first calculation of the rate for plasmon production in semiconductors from nuclei recoiling against dark matter. The process is analogous to bremsstrahlung of transverse photon modes, but with a longitudinal plasmon mode emitted instead. For dark matter in the 10 MeV—1 GeV mass range, we find that the plasmon bremsstrahlung rate is 4–5 orders of magnitude smaller than that for elastic scattering, but 4–5 orders of magnitude larger than the transverse bremsstrahlung rate. Because the plasmon can decay into electronic excitations and has characteristic energy given by the plasma frequency ω p , with ω p ≈ 16 eV in Si crystals, plasmon production provides a new signature and method to detect nuclear recoils from sub-GeV dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Which hadronic decay modes are good for {eta}{sub b} searching: Double J/{psi} or something else?

It has been controversial whether {eta}{sub b} can be discovered in Tevatron Run 2 through the decay {eta}{sub b}{yields}J/{psi}J/{psi} followed by J/{psi}{yields}{mu}{sup +}{mu}{sup -}. I clear this controversy by an explicit calculation which predicts Br[{eta}{sub b}{yields}J/{psi}J/{psi}] to be of order 10{sup -8}. It is concluded that observing {eta}{sub b} through this decay mode in Tevatron Run 2 may be rather unrealistic. The {eta}{sub b} may be observed in the forthcoming CERN LHC experiments through the 4-lepton channel, if the background events can be significantly reduced by imposing some kinematical cuts. By some rough but plausible considerations, I find that the analogous decay processes {eta}{sub b}{yields}VV, D*D* also have very suppressed branching ratios; nevertheless it may be worth looking for {eta}{sub b} at LHC and Super B factory through the decay modes {eta}{sub b}{yields}K{sub S}K{sup {+-}}{pi}{sup {+-}}, D*D.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Half-Bridge On-State Voltage Sensor for In-Situ Measurements

Current prognostics for life expectancy of power semiconductors utilize off-line measurements of the on-state resistance. Presented is a half-bridge (HB) on-state voltage (VON) sensor capable of being utilized for in-situ measurements enabling continuous and real-time monitoring of the on-state resistance. The design provides a single VON measurement output that contains independent VON information of both high and low side devices in a HB leg. The measurement output is referenced from the middle point of the HB and combines the two complementary VON sensing outputs. This system reduces the number of components, required number of analog signal processing circuits, and ADC channels for in-situ health monitoring of a power electronics system. These reductions will facilitate integration of the VON sensor with the gate driver board and achieve low system profile. The experimental results demonstrate the proposed VON measurements while switching with inductive and resistive loads.

Roy, Chondon↗

Control System for RF OPM

SAND2025-01910O This software built in LabVIEW FPGA provides experimental control of the RF OPM prototype via a reconfigurable NI I/O card. It samples the analog input, processes it on the FPGA in real time, and generates control and feedback outputs to control and optimize the operation of the device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bainbridge, Jonathan↗

Quantum Network Repeater Simulation Package (QNPack) v1.0.0

Existing quantum network testbeds and prototypes are typically implemented in laboratory experiments with limited functionality and operate in a tightly coupled manner. These characteristics make it difficult to evaluate the behavior of emerging quantum platforms and protocols beyond local resource limitations. The QNPack software enables full-stack modeling of quantum repeater networks that allows researchers to simulate new approaches, and understand emergent behaviors, from local to national scales. Novel capabilities include: (1) performant and accurate quantum models that can be executed as independent simulations, which will allow users to characterize specific analog quantum processes, quantum devices, and protocols, (2) a modular and extensible approach to the simulation architecture to accommodate new quantum technologies, protocols, and topologies as they are developed across the quantum repeater generations under evaluation, and (3) a focus on managing the interactions between the simulation framework sub-components so that they may be re-used and composed in flexible ways.

Kissel, Ezra [Lawrence Berkeley National Laborator↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗