Test Standard Developed for Determining the Slow Crack Growth of Advanced Ceramics at Ambient Temperature

The service life of structural ceramic components is often limited by the process of slow crack growth. Therefore, it is important to develop an appropriate testing methodology for accurately determining the slow crack growth design parameters necessary for component life prediction. In addition, an appropriate test methodology can be used to determine the influences of component processing variables and composition on the slow crack growth and strength behavior of newly developed materials, thus allowing the component process to be tailored and optimized to specific needs. At the NASA Lewis Research Center, work to develop a standard test method to determine the slow crack growth parameters of advanced ceramics was initiated by the authors in early 1994 in the C 28 (Advanced Ceramics) committee of the American Society for Testing and Materials (ASTM). After about 2 years of required balloting, the draft written by the authors was approved and established as a new ASTM test standard: ASTM C 1368-97, Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature. Briefly, the test method uses constant stress-rate testing to determine strengths as a function of stress rate at ambient temperature. Strengths are measured in a routine manner at four or more stress rates by applying constant displacement or loading rates. The slow crack growth parameters required for design are then estimated from a relationship between strength and stress rate. This new standard will be published in the Annual Book of ASTM Standards, Vol. 15.01, in 1998. Currently, a companion draft ASTM standard for determination of the slow crack growth parameters of advanced ceramics at elevated temperatures is being prepared by the authors and will be presented to the committee by the middle of 1998. Consequently, Lewis will maintain an active leadership role in advanced ceramics standardization within ASTM. In addition, the authors have been and are involved with several international standardization organizations including the Versailles Project on Advanced Materials and Standards (VAMAS), the International Energy Agency (IEA), and the International Organization for Standardization (ISO). The associated standardization activities involve fracture toughness, strength, elastic modulus, and the machining of advanced ceramics.

Choi, Sung R.↗

An Improved Approach for Analyzing the Oxygen Compatibility of Solvents and other Oxygen-Flammable Materials for Use in Oxygen Systems

Solvents used to clean oxygen system components must be assessed for oxygen compatibility, as incompatible residue or fluid inadvertently left behind within an oxygen system can pose a flammability risk. The most recent approach focused on solvent ignition susceptibility to assess the flammability risk associated with these materials. Previous evaluations included Ambient Pressure Liquid Oxygen (LOX) Mechanical Impact Testing (ASTM G86) and Autogenous Ignition Temperature (AIT) Testing (ASTM G72). The goal in this approach was to identify a solvent material that was not flammable in oxygen. As environmental policies restrict the available options of acceptable solvents, it has proven difficult to identify one that is not flammable in oxygen. A more rigorous oxygen compatibility approach is needed in an effort to select a new solvent for NASA applications. NASA White Sands Test Facility proposed an approach that acknowledges oxygen flammability, yet selects solvent materials based on their relative oxygen compatibility ranking, similar to that described in ASTM G63-99. Solvents are selected based on their ranking with respect to minimal ignition susceptibility, damage and propagation potential, as well as their relative ranking when compared with other solvent materials that are successfully used in oxygen systems. Test methods used in this approach included ASTM G86 (Ambient Pressure LOX Mechanical Impact Testing and Pressurized Gaseous Oxygen (GOX) Mechanical Impact Testing), ASTM G72 (AIT Testing), and ASTM D240 (Heat of Combustion (HOC) Testing). Only four solvents were tested through the full battery of tests for evaluation of oxygen compatibility: AK-225G as a baseline comparison, Solstice PF, L-14780, and Vertrel MCA. Baseline solvent AK-225G exhibited the lowest HOC and highest AIT of solvents tested. Nonetheless, Solstice PF, L-14780, and Vertrel MCA HOCs all fell well within the range of properties that are associated with proven oxygen system materials. Tested AITs for these solvents fell only slightly lower than the AIT for the proven AK-225G solvent. Based on these comparisons in which solvents exhibited properties within those ranges seen with proven oxygen system materials, it is believed that Solstice PF, L-14780, and Vertrel MCA would perform well with respect to oxygen compatibility.

Harper, Susan A.↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Environmentally safe aviation fuels

In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.

Liberio, Patricia D.↗

High Temperature, Slow Strain Rate Forging of Advanced Disk Alloy ME3

The advanced disk alloy ME3 was designed in the HSR/EPM disk program to have extended durability at 1150 to 1250 F in large disks. This was achieved by designing a disk alloy and process producing balanced monotonic, cyclic, and time-dependent mechanical properties. combined with robust processing and manufacturing characteristics. The resulting baseline alloy, processing, and supersolvus heat treatment produces a uniform, relatively fine mean grain size of about ASTM 7, with as-large-as (ALA) grain size of about ASTM 3. There is a long term need for disks with higher rim temperature capabilities than 1250 F. This would allow higher compressor exit (T3) temperatures and allow the full utilization of advanced combustor and airfoil concepts under development. Several approaches are being studied that modify the processing and chemistry of ME3, to possibly improve high temperature properties. Promising approaches would be applied to subscale material, for screening the resulting mechanical properties at these high temperatures. n obvious path traditionally employed to improve the high temperature and time-dependent capabilities of disk alloys is to coarsen the grain size. A coarser grain size than ASTM 7 could potentially be achieved by varying the forging conditions and supersolvus heat treatment. The objective of this study was to perform forging and heat treatment experiments ("thermomechanical processing experiments") on small compression test specimens of the baseline ME3 composition, to identify a viable forging process allowing significantly coarser grain size targeted at ASTM 3-5, than that of the baseline, ASTM 7.

Gabb, Timothy P.↗

Life Prediction/Reliability Data of Glass-Ceramic Material Determined for Radome Applications

Brittle materials, ceramics, are candidate materials for a variety of structural applications for a wide range of temperatures. However, the process of slow crack growth, occurring in any loading configuration, limits the service life of structural components. Therefore, it is important to accurately determine the slow crack growth parameters required for component life prediction using an appropriate test methodology. This test methodology also should be useful in determining the influence of component processing and composition variables on the slow crack growth behavior of newly developed or existing materials, thereby allowing the component processing and composition to be tailored and optimized to specific needs. Through the American Society for Testing and Materials (ASTM), the authors recently developed two test methods to determine the life prediction parameters of ceramics. The two test standards, ASTM 1368 for room temperature and ASTM C 1465 for elevated temperatures, were published in the 2001 Annual Book of ASTM Standards, Vol. 15.01. Briefly, the test method employs constant stress-rate (or dynamic fatigue) testing to determine flexural strengths as a function of the applied stress rate. The merit of this test method lies in its simplicity: strengths are measured in a routine manner in flexure at four or more applied stress rates with an appropriate number of test specimens at each applied stress rate. The slow crack growth parameters necessary for life prediction are then determined from a simple relationship between the strength and the applied stress rate. Extensive life prediction testing was conducted at the NASA Glenn Research Center using the developed ASTM C 1368 test method to determine the life prediction parameters of a glass-ceramic material that the Navy will use for radome applications.

Choi, Sung R.↗

An Elementary Overview of the Selection of Materials for Service in Oxygen-Enriched Environments

The process for selecting materials for use in oxygen or oxygen-enriched environments is one that continues to be investigated by many industries due to the importance to those industries of oxygen systems. There are several excellent resources available to assist oxygen systems design engineers and end-users, with the most comprehensive being ASTM MNL-36, Safe Use of Oxygen and Oxygen Systems: Handbook for Design, Operation and Maintenance, 2nd Edition. ASTM also makes available several standards for oxygen systems. However, the ASTM publications are extremely detailed, and typically designed for professionals who already possess a working knowledge of oxygen systems. No notable resource exists, whether an ASTM or other organizational publication, which can be used to educate engineers or technicians who have no prior knowledge of the nuances of oxygen system design and safety. This paper will fill the void for information needed by organizations that design or operate oxygen systems. The information in this paper is not new information, but is a concise and easily understood summary of selecting materials for oxygen systems. This paper will serve well as an employee s first introduction to oxygen system materials selection, and probably the employee s first introduction to ASTM.

Davis, Samuel Eddie↗

CONSTRAINT-INDEPENDENT CONSTANT CTOA DETERMINATION FOR DUCTILE STABLE CRACK GROWTH

Crack tip opening angle (CTOA) has been used as a reliable fracture toughness parameter for decades to characterize stable ductile crack growth for thin-walled aerospace structures in the low-constraint conditions. Recently, the CTOA parameter was also applied to the pipeline industry, and a CTOA test standard ASTM E3039 was thus developed for testing a critical constant CTOA. Research showed that the constant CTOA can reasonably describe fracture toughness required to arrest a dynamic crack propagation for a modern gas pipeline. However, the CTOA fracture criterion requires constraint-independent CTOA toughness against stable ductile crack growth. ASTM E3039 recommends a drop weight tearing test (DWTT) specimen for CTOA testing. Since a shallow crack is used, DWTT measured CTOA may depend on constraint level at the crack tip. To understand if it is the case, this paper evaluates the critical CTOA for a set of fracture toughness tests on single edge notched bend (SENB) specimens with shallow and deep cracks based on four CTOA estimation models. In which, the Ln(P)-LLD linear fit model is similar to that used by ASTM E3039 in the CTOA calculation. Fracture test data for X80 pipeline steel and HY80 structural steel are considered in the CTOA evaluation. The results show that the four CTOA models can determine a crack size-independent constant CTOA over stable ductile crack growth for the SENB specimens. As a result, CTOA determined by ASTM E3039 is constraintindependent and transferable to use for an actual crack propagating in a gas pipeline.

Zhu, Xian-Kui↗

Metal Scrap Upcycling with Shear Assisted Processing and Extrusion (ShAPE)

The overarching objective of this project is to convert metal scraps, such as aluminum, titanium, and other alloys provided by the industry, into extruded tubing, wires, and rods. Upcycling of scrap will be accomplished using Shear Assisted Processing and Extrusion (ShAPE). This approach is a new solution for recycling. The specific aims of this project are as follows: 1. Receive metal scrap under a Material Transfer Agreement (MTA), in the form of billets, from select industry partners that meet the following requirements: outer diameter of 1.245 inches (+/-0.003 inches), inner diameter drilled with a 0.404-inch drill bit, and a length of 4.0 inches (+/-0.01 inches). The billet must be cast or compacted to greater than 98% density. If the industry partner does not have the capabilities to prepare the billets, PNNL can make introductions to third-party entities as needed. Industry partners will also provide a composition analysis as weight percent. 2. Extrude metal scrap via the ShAPE process at PNNL. 3. Evaluate and benchmark the extrudate material properties per the ASTM B557-15 – Testing Tubulars Standard or similar wire and rod standards. 4. Characterize the extrudate microstructure for any of the following: grain size, second phase composition, and texture. Additional testing may include corrosion per the ASTM B117 standard and electro-potential. 5. Deliver specimens to industry partners under an MTA for additional third-party evaluations. Industry partners will, in return, provide a non-proprietary report on any testing, including testing per the ASTM B557-15, ASTM B117, and other industry standards. 6. PNNL will develop data and insights to support intellectual property capture, a published non-proprietary technical report, research collaborations, and commercialization opportunities.

36 MATERIALS SCIENCE↗

Determination of Constraint-Independent Crack Tip Opening Angle for Stable Crack Growth in High-Strength Ductile Steels

The crack tip opening angle (CTOA) is one of fracture toughness parameters that has been used for decades in describing large stable crack growth in thin-walled aerospace structures under the low-constraint conditions. Recently, the pipeline industry has developed a growing interest in using the CTOA parameter to serve as the minimum required fracture toughness to arrest dynamic crack propagation in modern gas transmission pipelines made of high-strength ductile steel. To meet this industrial need, the CTOA test standard ASTM E3039 was therefore developed for measuring the constant critical CTOA. ASTM E3039 recommends a drop weight tearing test (DWTT) specimen with a shallow crack for standard CTOA testing, but its CTOA may depend on the low constraint condition of the DWTT specimen at the crack tip. Verifying the constraint independence of the DWTT-measured CTOA thus becomes indispensable for applying CTOA toughness to the running fracture control in the pipeline design. For this purpose, the present paper evaluates critical CTOA values in a set of fracture toughness tests on single-edge notched bend (SENB) specimens with shallow and deep cracks, based on four CTOA estimation models. Among these, the Ln(P)-LLD linear fit model is similar to that recommended by ASTM E3039 for CTOA calculation. Fracture test data for X80 pipeline steel and HY80 structural steel were considered in the CTOA evaluation. The results showed that the four CTOA models were able to determine a constraint independent CTOA value for stable crack growth in the SENB specimens. As a result, a single, reliable, constant CTOA value could be determined regardless of the specimen geometry or the crack-tip constraint conditions. Therefore, the CTOA measured using ASTM E3039 is constraint-independent and transferable to use in cases of actual cracks propagating in gas transmission pipelines.

36 MATERIALS SCIENCE↗

The oxygen sensitivity/compatibility ranking of several materials by different test methods

Eleven materials were evaluated for oxygen compatibility using the following test methods: heat of combustion (ASTM D 2015), liquid oxygen impact (ASTM D 2512), pneumatic impact (ASTM G 74), gaseous mechanical impact (ASTM G 86), autogenous ignition temperature by pressurized differential scanning calorimeter, and the determination of the 50 percent reaction level in liquid oxygen using silicon carbide as a reaction enhancer. The eleven materials evaluated were: Teflon TFE, Vespel SP-21, Krytox 240AC, Viton PLV5010B, Fluorel E2160, Kel F 81, Fluorogold, Fluorogreen E-600, Rulon A, Garlock 8573, nylon 6/6.

Lockhart, Billy J.↗

Predictability of Gaseous Impact Ignition Sensitivity from Autoignition Temperature Data

An analysis of cumulative binomial probabilities for a quantal-type test like ASTM G74 indicates that for a probability of reaction in a single trial of 0.05, the probability of obtaining zero reactions in 20 trials is only approximately 36 percent, Because the lack of precision with the ASTM G74 test logic could be potentially misleading, an investigation was conducted to determine if pneumatic impact sensitivity could be predicted more reliably from other, more precise test methods. Pneumatic impact sensitivity tests were conducted following ASTM G74, but employing more rigorous test logics; autoignition temperature tests were conducted per ASTM G72. Polytetrafluoroethylene (PTFE), Viton A, polyethylene, polyoxymethylene polyamide, and silicone were the polymers used. After a fixed number of pneumatic impact tests was performed at set pressures, a plot of reaction frequency over a 3.4 to 24.1 MPa impact pressure range indicated that PTFE, Viton A, and silicone would outperform other polymers. The 50 percent pneumatic impact reactivity level was determined with the Bruceton test method. The data obtained resulted in a strong correlation between the 50 percent reactivity level and the autoignition temperature of polymers, indicating similar ignition mechanisms.

Hirsh, David↗

Microstructural Evaluation of Forging Parameters for Superalloy Disks

Forgings of nickel base superalloy were formed under several different strain rates and forging temperatures. Samples were taken from each forging condition to find the ASTM grain size, and the as large as grain (ALA). The specimens were mounted in bakelite, polished, etched and then optical microscopy was used to determine grain size. The specimens ASTM grain sizes from each forging condition were plotted against strain rate, forging temperature, and presoak time. Grain sizes increased with increasing forging temperature. Grain sizes also increased with decreasing strain rates and increasing forging presoak time. The ALA had been determined from each forging condition using the ASTM standard method. Each ALA was compared with the ASTM grain size of each forging condition to determine if the grain sizes were uniform or not. The forging condition of a strain rate of .03/sec and supersolvus heat treatment produced non uniform grains indicated by critical grain growth. Other anomalies are noted as well.

Falsey, John R.↗

Three-Body Abrasion Testing Using Lunar Dust Simulants to Evaluate Surface System Materials

Numerous unexpected operational issues relating to the abrasive nature of lunar dust, such as scratched visors and spacesuit pressure seal leaks, were encountered during the Apollo missions. To avoid reoccurrence of these unexpected detrimental equipment problems on future missions to the Moon, a series of two- and three-body abrasion tests were developed and conducted in order to begin rigorously characterizing the effect of lunar dust abrasiveness on candidate surface system materials. Two-body scratch tests were initially performed to examine fundamental interactions of a single particle on a flat surface. These simple and robust tests were used to establish standardized measurement techniques for quantifying controlled volumetric wear. Subsequent efforts described in the paper involved three-body abrasion testing designed to be more representative of actual lunar interactions. For these tests, a new tribotester was developed to expose samples to a variety of industrial abrasives and lunar simulants. The work discussed in this paper describes the three-body hardware setup consisting of a rotating rubber wheel that applies a load on a specimen as a loose abrasive is fed into the system. The test methodology is based on ASTM International (ASTM) B611, except it does not mix water with the abrasive. All tests were run under identical conditions. Abraded material specimens included poly(methyl methacrylate) (PMMA), hardened 1045 steel, 6061-T6 aluminum (Al) and 1018 steel. Abrasives included lunar mare simulant JSC- 1A-F (nominal size distribution), sieved JSC-1A-F (<25 m particle diameter), lunar highland simulant NU-LHT-2M, alumina (average diameter of 50 m used per ASTM G76), and silica (50/70 mesh used per ASTM G65). The measured mass loss from each specimen was converted using standard densities to determine total wear volume in cm3. Abrasion was dominated by the alumina and the simulants were only similar to the silica (i.e., sand) on the softer materials of aluminum and PMMA. The nominal JSC- 1A-F consistently showed more abrasion wear than the sieved version of the simulant. The lunar dust displayed abrasivity to all of the test materials, which are likely to be used in lunar landing equipment. Based on this test experience and pilot results obtained, recommendations are made for systematic abrasion testing of candidate materials intended for use in lunar exploration systems and in other environments with similar dust challenges.

Kobrick, Ryan L.↗

Applications of Automation Methods for Nonlinear Fracture Test Analysis

Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

Allen, Phillip A.↗

International Standards for Properties and Performance of Advanced Ceramics - 30 years of Excellence

Mechanical and physical properties/performance of brittle bodies (e.g., advanced ceramics and glasses) can be difficult to measure correctly unless the proper techniques are used. For three decades, ASTM Committee C28 on Advanced Ceramics, has developed numerous full-consensus standards (e.g., test methods, practices, guides, terminology) to measure various properties and performance of a monolithic and composite ceramics and coatings that, in some cases, may be applicable to glasses. These standards give the "what, how, how not, why, why not, etc." for many mechanical, physical, thermal, properties and performance of advanced ceramics. Use of these standards provides accurate, reliable, repeatable and complete data. Involvement in ASTM Committee C28 has included users, producers, researchers, designers, academicians, etc. who write, continually update, and validate through round robin test programmes, more than 45 standards in the 30 years since the Committee's inception in 1986. Included in this poster is a pictogram of the ASTM Committee C28 standards and how to obtain them either as i) individual copies with full details or ii) a complete collection in one volume. A listing of other ASTM committees of interest is included. In addition, some examples of the tangible benefits of standards for advanced ceramics are employed to demonstrate their practical application.

composites↗

NASA Ground-based Layered Pressure Vessels Materials Report

A significant portion of Layered Pressure Vessels (LPVs) manufactured for NASA in the 1950s and ’60s are of non-code construction. These vessels were constructed to the standards of individual manufacturers rather than an industry or consensus standard and often contain legacy or proprietary materials, which have poor or no characterization. Obtaining correct material properties is the first step in assuring vessel safety and predicting life and critical failure modes before they happen. This report details the efforts of the LPV Project related to material properties and characterization. The goal in testing materials from deconstructed vessels was to provide material characterization utilizing modern test methods that would give a strong probabilistic base as an option for future analysis. ASTM E1820, Standard Test Method for Measurement of Fracture Toughness was used for fracture toughness; ASTM E1921, Standard Test Method for Determination of Reference Temperature, T0, for Ferritic Steels in the Transition Range for transition temperature; and ASTM E647, Standard Test Method for Measurement of Fatigue Crack Growth Rates for fatigue crack growth. Particular focus was placed on determination of transition temperature through evaluation of the T0 reference temperature in accordance with ASTM E1921. Transition temperature testing allows for a probabilistic analysis of vessel materials that may be operating at temperatures below the transition from ductile tearing to brittle cleavage failure. This test method was not available at the time of construction and has proved invaluable to the characterization of older ferritic steels. The values reported are specific to the largest body of materials found in the current NASA fleet, but do not claim to be all inclusive. As demonstrated in this report, some materials contain extreme lot-to-lot variability. In some cases, this can be comfortably bounded by worst case probabilistic methods, however it is always recommended that vessel specific data be collected in as much depth as possible to ensure correct assumptions and avoid unduly restricting vessel usage.

Layered Pressure Vessel↗

A Procedure to Quantify Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography

Refractory composites are relevant for hot-structure applications on re-entry vehicles. To develop optimized high-performance hot structures, accurate material property data is required. Material properties that often limit design in two-dimensional (2-D) composites are interlaminar strengths. A better understanding of the failure mechanisms for interlaminar shear (ILS), interlaminar tension (ILT), and curved-beam interlaminar tension (CB-ILT) tests can provide insight on improving the design and fabrication of refractory composites. In-situ tests were performed to capture the progressive failure in American Society for Testing and Materials (ASTM) sized ILS (ASTM D3846), ILT (ASTM D7291), and CB-ILT (ASTM D6415) specimens. Before measuring internal damage of refractory composites specimens, the methodology of the test setup warrants a complete and thorough discussion. Detail on the test procedure, test stand design, micro-x-ray computed tomography (CT) configuration, data processing, and CT system uncertainty is discussed. Through keeping the many parameters of the CT system consistent, the uncertainty of the CT system was minimized, optimizing the quality of measurements. The overall quality of a CT scan can be quantified by three metrics: voxel resolution, minimal voxel resolution feature detection, and directional variability. A better understanding of the progressive failure mechanisms of refractory composites is provided by the results of both the present discussion and the one found in the accompanying paper titled “Analysis of Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography”.

In-situ micro-x-ray CT↗