Search NASA⌕ Search

SEARCH · Search NASA

Results for “ATOMIC IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks

A method has been developed for unambiguously measuring the exact magnetic field experienced by trapped mercury ions contained within an atomic clock intended for space applications. In general, atomic clocks are insensitive to external perturbations that would change the frequency at which the clocks operate. On a space platform, these perturbative effects can be much larger than they would be on the ground, especially in dealing with the magnetic field environment. The solution is to use a different isotope of mercury held within the same trap as the clock isotope. The magnetic field can be very accurately measured with a magnetic-field-sensitive atomic transition in the added isotope. Further, this measurement can be made simultaneously with normal clock operation, thereby not degrading clock performance. Instead of using a conventional magnetometer to measure ambient fields, which would necessarily be placed some distance away from the clock atoms, first order field-sensitive atomic transition frequency changes in the atoms themselves determine the variations in the magnetic field. As a result, all ambiguity over the exact field value experienced by the atoms is removed. Atoms used in atomic clocks always have an atomic transition (often referred to as the clock transition) that is sensitive to magnetic fields only in second order, and usually have one or more transitions that are first-order field sensitive. For operating parameters used in the (199)Hg(+) clock, the latter can be five orders of magnitude or more sensitive to field fluctuations than the clock transition, thereby providing an unambiguous probe of the magnetic field strength.

Burt, Eric A.↗

Positron Interactions with Atoms and Ions

Dirac, in 1928, combining the ideas of quantum mechanics and the ideas of relativity invented the well-known relativistic wave equation. In his formulation, he predicted an antiparticle of the electron of spin n-bar/2. He thought that this particle must be a proton. Dirac published his interpretation in a paper 'A theory of electrons and protons.' It was shown later by the mathematician Hermann Weyl that the Dirac theory was completely symmetric between negative and positive particles and the positive particle must have the same mass as that of the electron. In his J. Robert Oppenheimer Memorial Prize Acceptance Speech, Dirac notes that 'Blackett was really the first person to obtain hard evidence for the existence of a positron but he was afraid to publish it. He wanted confirmation, he was really over cautious.' Positron, produced by the collision of cosmic rays in a cloud chamber, was detected experimentally by Anderson in 1932. His paper was published in Physical Review in 1933. The concept of the positron and its detection were the important discoveries of the 20th century. I have tried to discuss various processes involving interactions of positrons with atoms and ions. This includes scattering, bound states and resonances. It has not been possible to include the enormous work which has been carried out during the last 40 or 50 years in theory and measurements.

Bhatia, Anand K.↗

High temperature transport properties of air

A general computer code was developed to allow calculation of atom-atom and ion-atom transport collision integrals from accurate potential energy curves described by a set of discrete data points for a broad range of scattering conditions. This code is based upon semiclassical approximations that properly account for quantum mechanical behavior such as tunneling effects near a barrier maximum, resonance charge exchange, and nuclear symmetry effects. Transport collision integrals were determined for N-N, O-O, N(+)-N, and O(+)-O interactions from complete sets of accurate potential functions derived from combined experimental and ab initio structure calculations. For the O-O case, this includes results for excited states. The calculated values of the N(+)-N and O(+)-O resonance charge exchange cross section Q(ex) agree well with measurements from beam experiment that are available at high energies where the diffusion cross section Q(d) satisfies Q(d) approximately equal to 2Q(ex).

Levin, E.↗

Kuang's Semi-Classical Formalism for Electron Capture Cross-Sections in Ion-Ion Collisions at Approximately to MeV/amu: Application to ENA Modeling

Recent discovery by STEREO A/B of energetic neutral hydrogen is spurring an interest and need for reliable estimates of electron capture cross sections at few MeVs per nucleon as well as for multi-electron ions. Required accuracy in such estimates necessitates detailed and involved quantum-mechanical calculations or expensive numerical simulations. For ENA modeling and similar purposes, a semi-classical approach offers a middle-ground approach. Kuang's semiclassical formalism to calculate electron-capture cross sections for single and multi-electron ions is an elegant and efficient method, but has so far been applied to limited and specific laboratory measurements and at somewhat lower energies. Our goals are to test and extend Kuang s method to all ion-atom and ion-ion collisions relevant to ENA modeling, including multi-electron ions and for K-shell to K-shell transitions.

Barghouty, A. F.↗

Comprehensive Characterization of Water Group Ion Composition and Distributions in Saturn's Magnetosphere With Cassini Plasma Spectrometer Data

Saturn's magnetosphere is continuously supplied with neutrals from the Enceladus plume and the icy rings, which undergo ionization and charge-exchange to form a complex water-group plasma environment. While the Cassini Plasma Spectrometer (CAPS) instrument has provided extensive compositional information, detailed separation of individual water-group ion species in time-of-flight (TOF) data has not previously been achieved. In this study, we perform forward modeling of CAPS-IMS energy-per-charge (E/Q) and TOF spectra obtained between 2004 and 2012 to resolve O + , OH + , H 2 O + , and H 3 O + and to characterize their plasma properties, including number density, temperature, and thermodynamic κ. Our results demonstrate that O + is the dominant thermal ion species throughout Saturn's magnetosphere, comprising up to ∼70% of the total ion population beyond ∼5 Saturn radii (R S ). In contrast, molecular ions such as OH + , H 2 O + , and H 3 O + dominate closer to Enceladus but rapidly dissociate into atomic ions between ∼5 and 10 R S . This radial region is also characterized by the steepest increase in plasma flow speed, which rises from ∼40% to ∼80% of rigid corotation. Simultaneously, ion velocity distributions approach Maxwell–Boltzmann equilibrium, as indicated by high kappa values. These findings provide new constraints on the ion–neutral chemistry that regulates the balance between molecular and atomic ions in Saturn's magnetosphere. They also emphasize the critical role of the 5–10 R S region as a transition zone for both plasma composition and dynamics. Our results refine previous CAPS-based studies and underscore the need to incorporate seasonal variability and ionospheric coupling into future global models of Saturn's plasma environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of the chemistry of the nightside ionosphere of Venus

A combination of numerical modeling and analysis of the Pioneer Venus UADS data base is studied, specifically data from the orbiter ion mass spectrometer (OIMS), orbiter neutral mass spectrometer (ONMS), and orbiter electron temperature probe (OETP). A one dimensional model of the Venus nightside ionosphere was set up in which downward fluxes of atomic ions are introduced at the upper boundary to simulate transport of ions from the dayside. The model shows that the densities of mass-28 ions, CO(+) + N(2+), resulting from an influx of atomic ions from the dayside are quite small, due to the high ionization potentials of CO and N2 that make chemical production difficult. A look at the data reveals that the actual densities of mass-28 ions are quite variable, from values near 10 to more than 10(exp 4) cm(exp -3). The excess mass-28 ions are assumed to be produced by electron precipitation and that the presence of high densities of mass-28 ions is a signature of auroral precipitation. A discussion of the atomic oxygen green line in the nightglow of Venus, which is produced mainly by dissociative recombination of O(2+), is presented. Original calculations of production rates of excited states for models based on Pioneer Venus data are also presented.

Fox, J. L.↗

Doubly charged atomic oxygen ions in the thermosphere. I - Photochemistry

Measurements of O(++) concentrations made by the Atmosphere Explorer C satellite are analyzed for altitudes where photochemical equilibrium conditions prevail in order to determine the photochemical sources and sinks of the doubly charged ion. The major loss process is found to be through partial charge exchange with neutral atomic oxygen with a rate coefficient of 1 x 10 to the -11th cu cm/s with an uncertainty of 40%. Above 220 km the major source is photo-ionization of O(+). However, X ray ionization of O (at not greater than 23.3 A) producing O(++) directly through the Auger process provides a better fit to the observed profile at lower altitudes.

Breig, E. L.↗

Systematics of ground-state potential minima between two main-group atoms or ions

A diagram is presented illustrating the internuclear separations between diatomic molecules or quasi-molecules with the exception of those containing transition metal and rare-earth atoms. As plotted as a function of the atomic numbers of the constituent atoms, the ground-state separations are observed to exhibit dramatic periodicities, as well as a gradual rise with increasing atomic number. The data for van der Waals molecules are not sufficient to predict the results of future experiments, although it is noted that the greatest internuclear separations are those of the alkali earth-rare gas molecules. Finally, it is found that to within the resolution of the diagram, isoelectronic molecules or quasi-molecules along the homonuclear direction have a constant internuclear separation.

Hefferlin, R.↗

The Deep Space Atomic Clock: Ushering in a New Paradigm for Radio Navigation and Science

The Deep Space Atomic Clock (DSAC) mission will demonstrate the on-orbit performance of a high-accuracy, high-stability miniaturized mercury ion atomic clock during a year-long experiment in Low Earth Orbit. DSAC's timing error requirement provides the frequency stability necessary to perform deep space navigation based solely on one-way radiometric tracking data. Compared to a two-way tracking paradigm, DSAC-enabled one-way tracking will benefit navigation and radio science by increasing the quantity and quality of tracking data. Additionally, DSAC also enables fully-autonomous onboard navigation useful for time-sensitive situations. The technology behind the mercury ion atomic clock and a DSAC mission overview are presented. Example deep space applications of DSAC, including navigation of a Mars orbiter and Europa flyby gravity science, highlight the benefits of DSAC-enabled one-way Doppler tracking.

atomic clock↗

Studies of the Chemistry of the Nightside Ionosphere of Venus

During the tenure of this grant, we have been looking into the chemistry of the nightside ionosphere of Venus with a view toward elucidating the relative roles of electron precipitation and plasma transport as sources of the nightside ionosphere. Secondary goals have included determining the densities of minor species on the nightside, and verifying the relative normalization of the Pioneer Venus orbiter ion mass spectrometer (OIMS) and orbiter neutral mass spectrometer (ONMS) in the photochemical equilibrium region. Our studies have involved a combination of numerical modeling and analysis of the Pioneer Venus UADS data base, specifically data from the OIMS, ONMS and electron temperature probe (OETP). We have set up a one-dimensional model of the Venus nightside ionosphere, in which downward fluxes of atomic ions are introduced at the upper boundary to simulate transport of ions from the dayside. Our model shows that the densities of mass-28 ions (CO+ + N+) resulting from an influx of atomic ions from the dayside are quite small, due to the high ionization potentials of CO and N2 that make chemical production difficult.

Fox, J.L.↗

Evidence for day-to-night ion transport at low solar activity in the Venus pre-dawn ionosphere

Periapsis of the Pioneer Venus (PV) spacecraft dropped below 180 km on August 28, 1992 near midnight, and 42 orbits of low altitude data at moderately low solar activity in the pre-dawn sector were obtained before contact was lost to the spacecraft in October, 1992. Through a combination of analysis of data from the PV orbiter ion mass spectrometer (OIMS) and modeling, we consider here what can be learned about the relative importance of plasma transport from the dayside and electron precipitation in maintaining the nightside ionosphere during the re-entry period. In particular, we examine here the atomic ion density profiles. We compute the average peak density of O(+) as a function of solar zenith angle and determine what fluxes of atomic ions or precipitating electrons would be necessary to produce those values. We then compare model calculations of the ion densities to those observed during the re-entry period. We find that the low solar activity nightside ionosphere shows evidence of significant day-to-night plasma transport.

Brannon, J. F.↗

Evidence for Day-to-Night Ion Transport at Low Solar Activity in the Venus Pre-Dawn Ionosphere

Periapsis of the Pioneer Venus spacecraft 2 dropped below 180 km on August 28, 1992 near midnight, and 42 orbits of low altitude data at moderately low solar activity in the pre-dawn sector were obtained before contact was lost to the spacecraft in October, 1992. Through a combination of analysis of data from the PV orbiter ion mass spectrometer (OIMS) and modeling, we consider here what can be learned about the relative importance of plasma transport from the dayside and electron precipitation in maintaining the nightside ionosphere during the re-entry period. In particular, we examine here the atomic ion density profiles. We compute the average peak density of O(+) as a function of solar zenith angle and determine what fluxes of atomic ions or precipitating electrons would he necessary to produce those values. We then compare model calculations of the ion densities to those observed during the re-entry period. We find that the low solar activity nightside ionosphere shows evidence of significant day-to-night plasma transport.

Brannon, J. F.↗

Evidence for Day-to-Night Ion Transport at Low Solar Activity in the Venus Pre-Dawn Ionosphere

Periapsis of the Pioneer Venus spacecraft dropped below 180 km on August 28, 1992 near midnight, and 42 orbits of low altitude data at moderately low solar activity in the pre-dawn sector were obtained before contact was lost to the spacecraft in October, 1992. Through a combination of analysis of data from the PV orbiter ion mass spectrometer (OIMS) and modeling, we consider here what can be learned about the relative importance of plasma transport from the dayside and electron precipitation in maintaining the nightside ionosphere during the re-entry period. In particular, we examine here the atomic ion density profiles. We compute the average peak density of O(+) as a function of solar zenith angle and determine what fluxes of atomic ions or precipitating electrons would be necessary to produce those values. We then compare model calculations of the ion densities to those observed during the re-entry period. We find that the low solar activity nightside ionosphere shows evidence of significant day-to-night plasma transport.

Brannon, J. F.↗

Charging and ion ejection dynamics of large helium nanodroplets exposed to intense femtosecond soft xray pulses

Ion ejection from charged helium nanodroplets exposed to intense femtosecond soft X-ray pulses is studied by single-pulse ion time-of-flight (TOF) spectroscopy in coincidence with small-angle X-ray scattering. Scattering images encode the droplet size and absolute photon flux incident on each droplet, while ion TOF spectra are used to determine the maximum ion kinetic energy, Ekin, of He+ j fragments (j = 1-4). Measurements span HeN droplet sizes between N similar to 10(7) and similar to 10(10) (radii R-0 = 78-578 nm), and droplet charges between similar to 9x10(-5) and similar to 3x10(-3) e/atom. Conditions encompass a wide range of ionization and expansion regimes, from departure of all photoelectrons from the droplet, leading to pure Coulomb explosion, to substantial electron trapping by the electrostatic potential of the charged droplet, indicating the onset of hydrodynamic expansion. The unique combination of absolute Xray intensities, droplet sizes, and ion Ekin on an event-by-event basis reveals a detailed picture of the correlations between the ionization conditions and the ejection dynamics of the ionic fragments. The maximum E-kin of He+ is found to be governed by Coulomb repulsion from unscreened cations across all expansion regimes. The impact of ion-atom interactions resulting from the relatively low charge densities is increasingly relevant with less electron trapping. The findings are consistent with the emergence of a charged spherical shell around a quasineutral plasma core as the degree of ionization increases. The results demonstrate a complex relationship between measured ion E-kin and droplet ionization conditions that can only be disentangled through the use of coincident single-pulse TOF and scattering data.

Helium↗

Vibrationally excited nitrogen in stable auroral red arcs and its effect on ionospheric recombination

The time-dependent continuity equations, including diffusion, were solved for the first six energy levels of molecular nitrogen for conditions in the thermosphere corresponding to stable auroral red (SAR) arcs. The results show that molecular nitrogen is excited vibrationally to the degree that the rate constant for the ionospheric loss process, O(+) + N2 yields NO(+) + N, is increased by as much as a factor of 7.6 at F2 region altitudes. It was found that deviations from the energetically equivalent Boltzmann distribution were large, causing the rate constant to be as much as 1.6 times the rate constant calculated for the Boltzmann distribution. These results indicate that SAR arc intensities as small as 58 R can produce noticeable increases in the ionosphere ion-atom interchange reaction rate and hence in the rate of loss of ionospheric electrons. It is suggested that the observed decrease of electron density in the F2 region in SAR arcs can probably be explained by enhanced reaction rates for ion-atom interchange between O(+) and N2 caused by vibrational excitation of molecular nitrogen by electron impact.

Newton, G. P.↗