Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-resolution width-modulated pulse rebalance electronics for strapdown gyroscopes and accelerometers

Three different rebalance electronic loops were designed, implemented, and evaluated. The loops were width-modulated binary types using a 614.4 kHz keying signal; they were developed to accommodate the following three inertial sensors with the indicated resolution values: (1) Kearfott 2412 accelerometer - resolution = 260 micro-g/data pulse, (2) Honeywell GG334 gyroscope - resolution = 3.9 milli-arc-sec/data pulse, (3) Kearfott 2401-009 accelerometer - resolution = 144 milli-g/data pulse. Design theory, details of the design implementation, and experimental results for each loop are presented.

Kennedy, E. J.↗

Accelerometer telemetry system

An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

Konigsberg, E.↗

Shuttle entry trajectory reconstruction using inflight accelerometer and gyro measurements

An error analysis has been made of a Shuttle postflight entry trajectory reconstruction process to obtain trajectory state estimation errors and to assess the impact of these errors on Shuttle aerodynamic force coefficient extraction. In this analysis, the entry trajectory is assumed to be reconstructed via numerical integration of onboard accelerometer and gyro measurements and constrained to satisfy ground-based radio tracking. The trajectory state estimation errors are calculated using a Kalman-Schmidt sequential filter assuming various measurement error models and combinations of ground-based tracking. The resultant trajectory estimation errors are analyzed in a simplified perturbation process to establish the accuracy to which postflight aerodynamic force coefficients can be determined. Results are presented which show that the principal error sources affecting the trajectory reconstruction and thus the force coefficient extraction, assuming perfect atmospheric density knowledge, are the accelerometer and gyro resolution, acceleration-sensitive gyro drifts, and the alignment uncertainties associated with integration on the Shuttle.

Compton, H. R.↗

Six-Axis Superconducting Accelerometer

Sensitivity and short-term stability high. Design combines superconductivity and magnetic levitation to achieve linear-acceleration sensitivity greater than conventional linear accelerometers, and short-term angular stability better than conventional gyroscopes. Improved accelerometer used to increase precision in inertial navigation and surveying, as sensitive multiple-axis seismic sensor, as component of tensor gravity gradiometer, or to sense accelerations of stabilized platforms or spacecraft.

Paik, Ho Jung↗

Rarefied aerodynamics and upper atmospheric flight results from the Orbiter High Resolution Accelerometer Package experiment

Data from the High Resolution Accelerometer Package (HiRAP) experiment on the Space Shuttle Orbiter have been analyzed for 10 flights to produce lift-drag (L/D) ratios in the free molecule, transition, and continuum flow flight regimes. Freestream density is also obtained in the altitude range from 60 km to 160 km using an aerodynamic model based upon earlier flight analysis of accelerometer data. The results of the L/D analysis of the latest four flights have been compared with the aerodynamic model developed from the first six HiRAP missions. The new data agree with the established flight-derived model, thereby validating earlier analysis. However, the arithmetic mean of the 10 flight-derived L/D values in the free molecular flow regime is 0.053 (+ or - 0.1) as compared to the initial value of 0.10 (+ or - 0.3), determined from STS-6. Updates to the Orbiter aerodynamic model values and calibration factors have been incorporated into the density calculations for all 10 flights to provide realistic absolute density. The derived density altitude profiles, which have been normalized to the U.S. Standard Atmosphere 1976, are characterized by a large amplitude wave pattern relative to the standard as seen in the initial flight analysis.

Blanchard, R. C.↗

Dual-Cantilever-Beam Accelerometer

Sensitivity to velocity changes along beam axis reduced. Weighted-end cantilever beams of accelerometer deflected equally by acceleration in y direction. When acceleration to right as well as up or down, right beam deflected more, while left beam deflected less. Bridge circuit averages outputs of strain gauges measuring deflections, so cross-axis sensitivity of accelerometer reduced. New device simple and inexpensive.

Reynolds, Emmitt A.↗

Shuttle high resolution accelerometer package experiment results - Atmospheric density measurements between 60-160 km

Indirect or inferred values of atmospheric density encountered by the Shuttle Orbiter during reentry have been calculated from acceleration measurements made by the High Resolution Accelerometer Package (HiRAP) and the Orbiter Inertial Measurement Unit (IMU) liner accelerometers. The atmospheric density data developed from this study represent a significant gain with respect to the body of data collected to date by various techniques in the altitude range of 60 to 160 km. The data are unique in that they cover a very wide horizontal range during each flight and provide insight into the actual density variations encountered along the reentry flight path. The data, which were collected over about 3 years, are also characterized by variations in solar activity, geomagnetic index, and local solar time. Comparison of the flight-derived densities with various atmospheric models have been made, and analyses have attempted to characterize the data and to show correlation with selected physical variables.

Blanchard, R. C.↗

Power flow in a beam using a 5-accelerometer probe

A method to determine structure-borne power flow is examined which uses central finite differences to approximate the field variables required to calculate the shear and bending components of flexural vibration. An experimental study using a beam driven by a shaker was performed with the aim of comparing estimates using this proposed five-accelerometer method and the conventional two-accelerometer, free-field method. The advantages and disadvantages of the new method are pointed out.

Downing, J. Micah↗

The measurement and control of helicopter blade modal response using blade-mounted accelerometers

The measurement of helicopter blade flapping, bending, and lag modal acceleration and displacement response using blade-mounted accelerometers is described. It is shown that knowledge of the blade mode shapes is sufficient to permit separation of the modal contributions to the accelerometer signals using matrix inversion. The application of the Mckillip (1985) filter to the identification of modal rate response is described. Finally, the design of flapping, bending, and lag mode controllers utilizing the conventional mesh plate is presented. The measurement technique is illustrated using flight test results obtained using a Black Hawk helicopter.

Ham, Norman D.↗

Spacelab-3 low-g accelerometer data from the fluid experiments system (FES)

The Fluids Experiment System (FES) flown aboard Spacelab 3 contained a Miniature Electrostatic Accelerometer (MESA). This accelerometer was purchased from Bell Aerospace, Textron and had three range (auto switching), bidirectional, three orthogonal axis capability. BGB, Inc. is in the process of examining the total mission data from this instrument. From these data, areas of interest are identified and related back to mission events. The basic format of the data for the total mission is root mean square (RMS), with two hours per plot.

Arnett, Gary↗

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

Noise power spectral density of the Sundstrand QA-2000 accelerometer

There are no good data on low frequency (less than 0.1 Hz) power spectral density (PSD) for the Q-Flex accelerometer. However, some preliminary stability measurements were made over periods of 12 to 24 hours and demonstrated stability less than 0.5 micro-g over greater than 12 hours. The test data appear to contain significant contributions from temperature variations at that level, so the true sensor contribution may be less than that. If what was seen could be construed as a true random process, it would correspond to about 0.1 micro-g rms over a bandwidth from 10(exp -5) Hz to about 1 Hz. Other studies of low frequency PSD in flexure accelerometers have indicated that material aging effects tend to approximate a first order Markhov process. If we combine such a model with the spectrum obtained at higher frequencies, it suggests the spectrum shown here as a conservative estimate of Q-Flex noise performance.

Peters, Rex↗

High performance, accelerometer-based control of the Mini-MAST structure at Langley Research Center

Many large space system concepts will require active vibration control to satisfy critical performance requirements such as line of sight pointing accuracy and constraints on rms surface roughness. In order for these concepts to become operational, it is imperative that the benefits of active vibration control be shown to be practical in ground based experiments. The results of an experiment shows the successful application of the Maximum Entropy/Optimal Projection control design methodology to active vibration control for a flexible structure. The testbed is the Mini-Mast structure at NASA-Langley and has features dynamically traceable to future space systems. To maximize traceability to real flight systems, the controllers were designed and implemented using sensors (four accelerometers and one rate gyro) that are actually mounted to the structure. Ground mounted displacement sensors that could greatly ease the control design task were available but were used only for performance evaluation. The use of the accelerometers increased the potential of destabilizing the system due to spillover effects and motivated the use of precompensation strategy to achieve sufficient compensator roll-off.

Collins, Emmanuel G., Jr.↗

The High Resolution Accelerometer Package (HiRAP) flight experiment summary for the first 10 flights

The High Resolution Accelerometer Package (HiRAP) instrument is a triaxial, orthogonal system of gas damped accelerometers with a resolution of 1 x 10(exp -6) g (1 micro-g). The purpose of HiRAP is to measure the low frequency component of the total acceleration along the orbiter vehicle (OV) body axes while the OV descends through the rarefied flow flight regime. Two HiRAP instruments have flown on a total of 10 Space Transport System (STS) missions. The aerodynamic component of the acceleration measurements was separated from the total acceleration. Instrument bias and orbiter mechanical system acceleration effects were incorporated into one bulk bias. The bulk bias was subtracted from the acceleration measurements to produce aerodynamic descent data sets for all 10 flights. The aerodynamic acceleration data sets were input to an aerodynamic coefficient model. The aerodynamic acceleration data and coefficient model were used to estimate the atmospheric density for the altitude range of 140 to 60 km and a downrange distance of 600 km. For 8 of 10 flights results from this model agree with expected results. For the results that do not agree with expected results, a variety of error sources have been explored.

Blanchard, Robert C.↗

High performance, accelerometer-based control of the Mini-MAST structure

Many large space system concepts will require active vibration control to satisfy critical performance requirements such as line of sight pointing accuracy and constraints on rms surface roughness. In order for these concepts to become operational, it is imperative that the benefits of active vibration control be shown to be practical in ground based experiments. The results of an experiment shows the successful application of the Maximum Entropy/Optical Projection control design methodology to active vibration control for a flexible structure. The testbed is the Mini-Mast structure at NASA-Langley and has features dynamically traceable to future space systems. To maximize traceability to real flight systems, the controllers were designed and implemented using sensors (four accelerometers and one rate gyro) that are actually mounted to the structure. Ground mounted displacement sensors that could greatly ease the control design task were available but were used only for performance evaluation. The use of the accelerometers increased the potential of destabilizing the system due to spillover effects and motivated the use of precompensation strategy to achieve sufficient compensator roll-off.

Collins, Emmanuel G., Jr.↗

Research on measurement and control of helicopter rotor response using blade-mounted accelerometers 1990-91

Wind tunnel testing of the full-size Model 412/IBC rotor performed at the NASA Ames Research Center is described. The use of blade-mounted accelerometers is found to be feasible for estimating or measuring blade flapping, lagging, and bending accelerations, rates, and displacements. Application of the imaginary swash plate concept to IBC systems leads to useful filtering of the blade accelerometer signals while permitting the control of a four-bladed rotor using measurements from any three blades. Rotor state measurements in the rotating system can be transformed to the corresponding nonrotating rotor states using the IBC algorithm with its associated filtering properties.

Ham, Norman D.↗

Input-output stability for accelerometer control systems

It is shown that, although accelerometer control systems are not well-posed in the sense of Salamon, a well-defined input-output relation exists. It is established that the output of an accelerometer control system can be described by the convolution of the input and a distribution. This distribution is Laplace transformable, and the Laplace transform of the distribution is the transfer function of the system.

Banks, H. T.↗

A miniature high-resolution accelerometer utilizing electron tunneling

New methods have been developed to implement high-resolution position sensors based on electron tunneling. These methods allow miniaturization while utilizing the position sensitivity of electron tunneling to give high resolution. A single-element tunneling accelerometer giving a displacement resolution of 0.002 A/sq rt Hz at 10 Hz, corresponding to an acceleration resolution of 5 x 10 exp -8 g/sq rt Hz, is described. A new dual-element tunneling structure which overcomes the narrow bandwidth limitations of a single-element structure is described. A sensor with an operating range of 5 Hz to 10 kHz, which can have applications as an acoustic sensor, is discussed. Noise is analyzed for fundamental thermal vibration of the suspended masses and is compared to electronic noise. It is shown that miniature tunnel accelerometers can achieve resolution such that thermal noise in the suspended masses is the dominant cause of the resolution limit. With a proof mass of order 100 mg, noise analysis predicts limiting resolutions approaching 10 exp -9 g/sq rt Hz in a 300 Hz band and 10 exp -8 g/sq rt Hz at 1 kHz.

Rockstad, Howard K.↗