Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Calibrating Accelerometers Using an Electromagnetic Launcher

A Pulse Forming Network (PFN), Helical Electromagnetic Launcher (HEML), Command Module (CM), and Calibration Table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored energy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass and is designed to accelerate 600 grams to 10 meters per second. The CM is microcontroller based running Arduino Software. The CM has a keypad input and 7 segment outputs of the bank voltage and desired voltage. After entering a desired bank voltage, the CM controls the charge of the PFN. When the two voltages are equal it allows the fire button to send a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile's tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocity meter and catch pot. The Target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely for the velocity meter to get an accurate reading. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

47 OTHER INSTRUMENTATION↗

Unsupervised learning from three-component accelerometer data to monitor the spatiotemporal evolution of meso-scale hydraulic fractures

Enhanced geothermal systems can provide a substantial share of the global energy demand. There exist several hurdles in the engineering implementations of such geothermal systems. One such hurdle is the accurate monitoring of the fracture networks created in subsurface through hydraulic stimulation of these systems. Micro seismicity associated with the stimulation is the primary means to locate the event hypocenters for estimating the stimulated rock volume. Existing methods for location the hypocenters are restricted to only the highest amplitude impulsive signals that are simultaneously detected on several sensors. Consequently, a large portion (usually ~99%) of the measurements are left unused. In this paper, an unsupervised manifold-approximation followed by clustering of 3-component accelerometer data is used to analyze the seismicity recorded on a monitoring well. With this method, a larger portion of the measured signal is used for the monitoring of the hydraulic fracture network. We analyze the EGS Collab experiment 1 microseismic data, recorded at the Sanford Underground Research Facility, South Dakota. Using the data from a single three-component accelerometer, the polarization features viz. Azimuth, incidence, rectilinearity, and planarity are used as inputs for the unsupervised manifold approximation followed by clustering. Our study shows that density-based clusters in the projected 3D space correspond to distinct types of hydraulically fractured zones around the injection point. Finally, we show that the temporal evolution of these clusters can be used to track fracture creation and propagation.

58 GEOSCIENCES↗

SPE-5 Ground-Motion Prediction at Far-Field Geophone and Accelerometer Array Sites and SPE-5 Moment and Corner-Frequency Prediction

This report offers predictions for the SPE-5 ground-motion and accelerometer array sites. These predictions pertain to the waveform and spectral amplitude at certain geophone sites using Denny&Johnson source model and a source model derived from SPE data; waveform, peak velocity and peak acceleration at accelerometer sites using the SPE source model and the finite-difference simulation with LLNL 3D velocity model; and the SPE-5 moment and corner frequency.

47 OTHER INSTRUMENTATION↗

Simple device produces accelerometer calibration pulse

Shock-impulse exciter produces a remote checkout of the amplitude calibration and frequency response of a piezoelectric vibration accelerometer. The exciter employs a bimetal spring to apply a mechanical acceleration pulse of a known amplitude and frequency to the accelerometer.

Source record↗

Miniature servo accelerometer is force- balanced

Miniature servo accelerometer measures unusually small forces of torques. The pendulous mass of the accelerometer is suspended by fused quartz torsion fibers in an electromagnetically force- balanced environment. It is used in gravity surveys for exploring mineral deposits.

Johnston, A. R.↗

Damping technique gives accelerometer flat frequency response

Piezoelectric accelerometer uses a viscous damping technique to achieve a flat frequency response over a wide frequency range in high acoustic environments. This eliminates the electrical overload on associated electronics and loss of useful data caused by oscillations of the accelerometer.

Wing, T.↗

Rectilinear accelerometer possesses self- calibration feature

Rectilinear accelerometer operates from an ac source with a phase-sensitive ac voltage output proportional to the applied accelerations. The unit includes an independent circuit for self-test which provides a sensor output simulating an acceleration applied to the sensitive axis of the accelerometer.

Henderson, R. B.↗

Instrument automatically selects peak acceleration signal from several accelerometers

Solid state circuit selects the highest of several ac accelerometer signals and gates this signal to an output amplifier, preserving all the frequency information in the peak signal. If the amplitudes of the accelerometer signals change with time, the circuit will continually switch to the highest signal, rejecting the smaller signals.

Chapman, C. P.↗

Miniature capacitive accelerometer is especially applicable to telemetry

Capacitive accelerometer design enables the construction of highly miniaturized instruments having full-scale ranges from 1 g to several hundred g. This accelerometer is applicable to telemetry and can be tailored to cover any of a large number of acceleration ranges and frequency responses.

Coon, G. W.↗

Low level accelerometer test methods are investigated

Problems associated with testing accelerometers to an accuracy where the standard error is less than .0000001 g are centered around the elimination of uncertainties in the acceleration input to the accelerometer. By placing a test rig in free fall, the uncertainty in the earths gravity field can be eliminated.

Nelson, R. H., Jr.↗

Low G accelerometer testing

Eight different types of low-g accelerometer tests are covered on the Bell miniature electrostatically suspended accelerometer (MESA) which is known to be sensitive to less than 10 to the minus 7th power earth's gravity. These tests include a mass attracting scheme, Leitz dividing head, Wild theodolite, precision gage blocks, precision tiltmeters, Hilger Watts autocollimator, Razdow Mark 2 autocollimator, and laser interferometer measuring system. Each test is described and a comparison of the results is presented. The output of the MESA was as linear and consistent as any of the available devices were capable of measuring. Although the extent of agreement varied with the test equipment used, it can only be concluded that the indicated errors were attributable to the test equipment coupled with the environmental conditions.

Vaughan, M. S.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems

Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems.

An algorithm for failure detection and identification for redundant non-orthogonal arrays of single degree of freedom gyros and accelerometers is described which is optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Minimax failure detection and identification in redundant gyro and accelerometer systems.

Minimax algorithms for failure detection and identification for redundant noncolinear arrays of single-degree-of-freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Contributions to the problem of piezoelectric accelerometer calibration

After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

Jakab, I.↗

High-resolution width-modulated pulse rebalance electronics for strapdown gyroscopes and accelerometers

Three different rebalance electronic loops were designed, implemented, and evaluated. The loops were width-modulated binary types using a 614.4 kHz keying signal; they were developed to accommodate the following three inertial sensors with the indicated resolution values: (1) Kearfott 2412 accelerometer - resolution = 260 micro-g/data pulse, (2) Honeywell GG334 gyroscope - resolution = 3.9 milli-arc-sec/data pulse, (3) Kearfott 2401-009 accelerometer - resolution = 144 milli-g/data pulse. Design theory, details of the design implementation, and experimental results for each loop are presented.

Kennedy, E. J.↗

Accelerometer telemetry system

An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

Konigsberg, E.↗