Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

Cooling Technology for Large Space Telescopes

NASA's New Millennium Program funded an effort to develop a system cooling technology, which is applicable to all future infrared, sub-millimeter and millimeter cryogenic space telescopes. In particular, this technology is necessary for the proposed large space telescope Single Aperture Far-Infrared Telescope (SAFIR) mission. This technology will also enhance the performance and lower the risk and cost for other cryogenic missions. The new paradigm for cooling to low temperatures will involve passive cooling using lightweight deployable membranes that serve both as sunshields and V-groove radiators, in combination with active cooling using mechanical coolers operating down to 4 K. The Cooling Technology for Large Space Telescopes (LST) mission planned to develop and demonstrate a multi-layered sunshield, which is actively cooled by a multi-stage mechanical cryocooler, and further the models and analyses critical to scaling to future missions. The outer four layers of the sunshield cool passively by radiation, while the innermost layer is actively cooled to enable the sunshield to decrease the incident solar irradiance by a factor of more than one million. The cryocooler cools the inner layer of the sunshield to 20 K, and provides cooling to 6 K at a telescope mounting plate. The technology readiness level (TRL) of 7 will be achieved by the active cooling technology following the technology validation flight in Low Earth Orbit. In accordance with the New Millennium charter, tests and modeling are tightly integrated to advance the technology and the flight design for "ST-class" missions. Commercial off-the-shelf engineering analysis products are used to develop validated modeling capabilities to allow the techniques and results from LST to apply to a wide variety of future missions. The LST mission plans to "rewrite the book" on cryo-thermal testing and modeling techniques, and validate modeling techniques to scale to future space telescopes such as SAFIR.

DiPirro, Michael↗

Feasibility of Passive Cryogenic Cooling for Solar Powered Outer Planetary Missions

Spacescience instruments with cooled detectors require innovative thermal cooling solutions to meet science objectives. Detector sensitivity increases with decreasing temperature and low optics temperatures are often needed to reduce background photon noise. As the detector spectral range coverage increases from the visible to far infrared also requires lower detector temperatures. Increasing demands on detector performance lead to larger format detectors and higher refresh rates resulting in significant increases in power dissipation. Passive coolers rely on emissive power of radiating surfaces to reject heat to space. As the operating temperature requirements of detectors and optics decreases, the ability to reject heat to space becomes increasingly more difficult. Reducing both cooler internal parasitic and external environmental heat loads and maximizing the passive cooler field of view to space will enhance performance. While instrument heat loads and passive cooler parasitic heat loads are controlled by instrument designers, the external environmental heat loads and cooler views to space are governed by spacecraft and mission designers. Solar powered planetary missions require large arrays to generate sufficient power for spacecraft subsystems and payloads. Two or more solar array wings with cell coverage of the order of 40-80 m2 are often needed to generate sufficient power at 3-6 AU. These large arrays are typically symmetrically configured and can extend tens of meters. The arrays along with spacecraft attitude requirements near the target planetary bodies pose significant challenges for passive cooling at large AU. It is very difficult to provide a clear field of view to space for the cooler with large articulating arrays while keeping solar loads from impinging the cooler and meeting the spacecraft attitude science pointing requirements. This is counter intuitive because of the decreasing solar flux and colder planetary body temperatures at large AU. This paper presents the challenges and opportunities of passive cryogenic cooling versus active cooling for solar powered planetary missions.

Rodriguez, Jose I.↗

Heat transfer distribution on a discontinuously convective cooled surface

An active cooling scheme in which discrete cooling passages are used was investigated. In this scheme, the coolant passages are placed perpendicular to the main stream direction. Streamwise temperature oscillations result from the highly cooled regions, near the coolant channels, being next to regions not directly cooled between the channels. The accuracy of the heat transfer rate predictions by these approximations was evaluated by means of both experimental and numerical investigations. Experiments were conducted at free stream Mach number of 6 with several cooling passages. Heat transfer measurements were made and corresponding theoretical analysis were performed for comparison in evaluating both local and overall deviations in the heat transfer rate.

Piva, R.↗

NASA Team Develops a Test Article to Demonstrate “Zero Boil-Off” Storage of Liquid Hydrogen via Cryocoolers and a Two-Stage Cooling Approach

Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, a NASA team is developing a test article to demonstrate the “zero boil-off” storage of liquid hydrogen using active cooling (cryocoolers) and a two-stage cooling approach. The current state of the art for storage of liquid hydrogen on-orbit is on the order of hours while future missions may require storage for months or even years. To enable such extended storage durations, “near zero” propellant loss, or “zero boil-off”, must be achieved. This may be accomplished with the implementation of “near zero” leakage components, a high performing suite of passive technologies to minimize the environmental heat loads, and active cooling via cryocoolers to intercept and remove heat from the propellant tanks and associated structure. Of course, with any cryogenic vehicle and mission, a mass and power trade should be conducted to determine if it is indeed feasible to carry the additional dry mass associated with active cooling, or if one could simply carry additional propellants to accommodate propellant loss which is typically not an option for a long duration mission.

Hydrogen Storage↗

Cooled Ceramic Matrix Composite Propulsion Structures Demonstrated

NASA's Next Generation Launch Technology (NGLT) Program has successfully demonstrated cooled ceramic matrix composite (CMC) technology in a scramjet engine test. This demonstration represented the world s largest cooled nonmetallic matrix composite panel fabricated for a scramjet engine and the first cooled nonmetallic composite to be tested in a scramjet facility. Lightweight, high-temperature, actively cooled structures have been identified as a key technology for enabling reliable and low-cost space access. Tradeoff studies have shown this to be the case for a variety of launch platforms, including rockets and hypersonic cruise vehicles. Actively cooled carbon and CMC structures may meet high-performance goals at significantly lower weight, while improving safety by operating with a higher margin between the design temperature and material upper-use temperature. Studies have shown that using actively cooled CMCs can reduce the weight of the cooled flow-path component from 4.5 to 1.6 lb/sq ft and the weight of the propulsion system s cooled surface area by more than 50 percent. This weight savings enables advanced concepts, increased payload, and increased range. The ability of the cooled CMC flow-path components to operate over 1000 F hotter than the state-of-the-art metallic concept adds system design flexibility to space-access vehicle concepts. Other potential system-level benefits include smaller fuel pumps, lower part count, lower cost, and increased operating margin.

Jaskowiak, Martha H.↗

Application of formal optimization techniques in thermal/structural design of a heat-pipe-cooled panel for a hypersonic vehicle

Nonlinear mathematical programming methods are used to design a radiantly cooled and heat-pipe-cooled panel for a Mach 6.7 transport. The cooled portion of the panel is a hybrid heat-pipe/actively cooled design which uses heat pipes to transport the absorbed heat to the ends of the panel where it is removed by active cooling. The panels are optimized for minimum mass and to satisfy a set of heat-pipe, structural, geometric, and minimum-gage constraints. Two panel concepts are investigated: cylindrical heat pipes embedded in a honeycomb core and an integrated design which uses a web-core heat-pipe sandwich concept. The latter was lighter and resulted in a design which was less than 10 percent heavier than an all actively cooled concept. The heat-pipe concept, however, is redundant and can sustain a single-point failure, whereas the actively cooled concept cannot. An additional study was performed to determine the optimum number of coolant manifolds per panel for a minimum-mass design.

Camarda, Charles J.↗

Cooling Duct Analysis for Transpiration/Film Cooled Liquid Propellant Rocket Engines

The development of a low cost space transportation system requires that the propulsion system be reusable, have long life, with good performance and use low cost propellants. Improved performance can be achieved by operating the engine at higher pressure and temperature levels than previous designs. Increasing the chamber pressure and temperature, however, will increase wall heating rates. This necessitates the need for active cooling methods such as film cooling or transpiration cooling. But active cooling can reduce the net thrust of the engine and add considerably to the design complexity. Recently, a metal drawing process has been patented where it is possible to fabricate plates with very small holes with high uniformity with a closely specified porosity. Such a metal plate could be used for an inexpensive transpiration/film cooled liner to meet the demands of advanced reusable rocket engines, if coolant mass flow rates could be controlled to satisfy wall cooling requirements and performance. The present study investigates the possibility of controlling the coolant mass flow rate through the porous material by simple non-active fluid dynamic means. The coolant will be supplied to the porous material by series of constant geometry slots machined on the exterior of the engine.

Micklow, Gerald J.↗

Assessment of the Impact of an Advanced Power System on a Turboelectric Single-Aisle Concept Aircraft

Electrified aircraft propulsion concepts show potential in using propulsion airframe inte-gration in order to increase efficiency in flight and therefore decrease fuel burn and emissions.Electrification offers component efficiency values greater than 90 percent, but the loss is in the form of low grade waste heat. A major challenge of electrified aircraft propulsion is managing that heat while minimizing any penalties associated with a thermal management system. This paper explores the effect of two innovations in the management of waste heat at the aircraft system level for a turboelectric single aisle concept. The first innovation is achieving a 3 times reduction in heat by developing high-efficiency components rather than managing the high levels of heat. The second takes advantage of the outer mold line of the aircraft to reject heat directly to the environment passively instead of adding active cooling loops that negatively impact the weight, power, and drag of the aircraft. In order to fully grasp the impact of the advanced power system, we develop methods of modeling the power and thermal management systems to be integrated in the full aircraft conceptual model. We then model the aircraft with a state of the art DC transmission system and active cooling loops as a baseline for our study. Our second model includes the advanced power system with active cooling, which results in a fuel burn reduction of 2.5 percent. Finally, in our third model we assess the benefit of an outer mold line cooling scheme with the advanced power system. The outer mold line cooling scheme with an advanced power system yields an additional 0.8 percent reduction in fuel burn,for an overall fuel burn reduction potential of 3.3 percent in addition to aerodynamic benefits of electrified aircraft propulsion.

Electric Aircraft↗

Mitigation of Autoignition Due to Premixing in a Hypervelocity Flow Using Active Wall Cooling

Preinjection of fuel on the forebody of an airbreathing vehicle is a proposed method to gain access to hypervelocity flight Mach numbers. However, this creates the possibility of autoignition either near the wall or in the core of the flow, thereby consuming fuel prematurely as well as increasing the amount of pressure drag on the vehicle. The computational fluid dynamics code VULCAN was used to conduct three dimensional simulations of the reacting flow in the vicinity of hydrogen injectors on a flat plate at conditions relevant to a Mach 12 notional flight vehicle forebody to determine the location where autoignition occurs. Active wall cooling strategies were formulated and simulated in response to regions of autoignition. It was found that tangential film cooling using hydrogen or helium were both able to nearly or completely eliminate wall autoignition in the flow domain of interest.

Axdahl, Erik↗

Current Status of Joint AFRL/NASA Microgravity Spray Cooling Research Activities

The Air Force Research Lab and the NASA Glenn Research Center are cooperatively examining spray cooling in a low and a variable gravity environment by conducting experiments principally aboard the NASA Reduced Gravity Aircraft. The objective of these research activities is to examine an effective high-heat flux, high-power thermal management technology using spray cooling for both aircraft and space-based platforms. Previous studies have demonstrated that two phase heat transfer and fluid management are issues that need to be examined. This effort has obtained preliminary results which confirm these concerns. More research is planned.

Michalak, Travis↗

Chromospheric activity of cool giant stars

During the seventh year of IUE twenty-six spectra of seventeen cool giant stars ranging in spectral type from K3 thru M6 were obtained. Together with spectra of fifteen stars observed during the sixth year of IUE, these low-resolution spectra have been used to: (1) examine chromospheric activity in the program stars and late type giants in general, and (2) evaluate the extent to which nonradiative heating affects the upper levels of cool giant photospheres. The stars observed in this study all have well determined TiO band strengths, angular diameters (determined from lunar occulations), bolometric fluxes, and effective temperatures. Chromospheric activity can therefore be related to effective temperatures providing a clearer picture of activity among cool giant stars than previously available. The stars observed are listed.

Steiman-Cameron, T. Y.↗

Fatigue Life of Haynes 188 Superalloy in Direct Connect Combustor Durability Rig

The Direct Connect Combustor Durability Rig (DCR) will provide NASA a flexible and efficient test bed to demonstrate the durability of actively cooled scramjet engine structure, static and dynamic sealing technologies, and thermal management techniques. The DCR shall be hydrogen fueled and cooled, and test hydrogen coolded structural panels at Mach 5 and 7. Actively cooled Haynes 188 superalloy DCR structural panels exposed to the combustion environment shall have electrodischarge machined (EDM) internal cooling holes with flowing liquid hydrogen. Hydrogen combustion could therefore produce severe thermal conditions that could challenge low cycle fatigue durability of this material. The objective of this study was to assess low cycle fatigue capability of Haynes 188 for DCR application. Tests were performed at 25 and 650 C, in hydrogen and helium environments, using specimens with low stress ground (LSG) and electro-discharge machined (EDM) surface finish. Initial fatigue tests in helium and hydrogen indicate the low cycle fatigue life capability of Haynes 188 in hydrogen appears quite satisfactory for the DCR application. Fatigue capability did not decrease with increasing test temperature. Fatigue capability also did not decrease with EDM surface finish. Failure evaluations indicate retention of ductility in all conditions. Additional tests are planned to reconfirm these positive trends.

Gabb, TIm↗

A Thermal Physiological Comparison of Two HazMat Protective Ensembles With and Without Active Convective Cooling

Wearing impermeable garments for hazardous materials clean up can often present a health and safety problem for the wearer. Even short duration clean up activities can produce heat stress injuries in hazardous materials workers. It was hypothesized that an internal cooling system might increase worker productivity and decrease likelihood of heat stress injuries in typical HazMat operations. Two HazMat protective ensembles were compared during treadmill exercise. The different ensembles were created using two different suits: a Trelleborg VPS suit representative of current HazMat suits and a prototype suit developed by NASA engineers. The two life support systems used were a current technology Interspiro Spirolite breathing apparatus and a liquid air breathing system that also provided convective cooling. Twelve local members of a HazMat team served as test subjects. They were fully instrumented to allow a complete physiological comparison of their thermal responses to the different ensembles. Results showed that cooling from the liquid air system significantly decreased thermal stress. The results of the subjective evaluations of new design features in the prototype suit were also highly favorable. Incorporation of these new design features could lead to significant operational advantages in the future.

Williamson, Rebecca↗

Space Exploration Applications for Development of High Capacity Cryocoolers

Long term storage of cryogens is necessary to enable NASAs long duration crewed missions to both the lunar and Martian surfaces. Such missions require in-space transport systems such as Nuclear Thermal Propulsion (NTP), and descent/ascent vehicles for transportation to and from the lunar and Martian surfaces. NTP systems and Lunar/Martian landers utilize cryogenic fluids to minimize architectural volume and mass. To further enhance the capability of these cryogenic systems, the Agency is putting emphasis on reusability, which requires the NTP and ascent/descent elements be replenished on-orbit via tankers or propellant depots, or on the lunar or Martian surface using liquefied in-situ produced propellants. NTP is one of the leading propulsion option for human Mars missions and requires liquid hydrogen to be stored on-orbit for over four years. For such a long duration mission, near “Zero Boil-Off” (ZBO) must be achieved which requires an optimized suite of passive Cryogenic Fluid Management technologies and active cooling (cryocoolers). Tens of Watts of 20K cooling is required to achieve ZBO conditions for NTP, however two-stage cooling using both 20K and 90K systems can lead to a significant reduction in both active cooling mass and power. The use of in-situ resources for lunar and Martian missions will require 150 Watts of 90K cooling for oxygen liquefaction and 300 Watts of 20K cooling for hydrogen liquefaction (lunar only). Descent/Ascent vehicles, propellant depots, and tankers will also require the use of cryocoolers to achieve ZBO conditions. To support these programs, NASA is developing high capacity 20K and 90K reverse turbo-Brayton cycle cryocoolers which offer a scalable, high efficiency, low vibration solution.

cryocooler↗

Cryogenic Nitrogen Thermosyphon Developed and Characterized

A two-phase nitrogen thermosyphon was developed at the NASA Glenn Research Center to efficiently integrate a cryocooler into an insulated liquid-nitrogen-filled tank as part of an advanced development zero-boiloff (ZBO) ground test. NASA Marshall Space Flight Center's (MSFC) Advanced Space Transportation Program supported this test to improve the performance of in-space propulsion system concepts. Recent studies (ref. 1) have shown significant mass reductions and other advantages when incorporating active cooling in a ZBO configuration, enabling consideration of high-performing cryogenic propellants for long-duration applications in space. Active cooling was integrated via a thermosyphon, made of copper, 42 in. (1070 mm) long with an inner diameter of 0.436 in. (11 mm). It was charged with nitrogen to 225 psia at 300 K, which provided a fill ratio of 15 percent. The temperatures and heat flows through the thermosyphon were monitored during the startup phase of the ZBO test, and steady-state tests were conducted over a range of increasing and decreasing heat flows. The results also were compared with the initial design calculations and with results for a similar thermosyphon. They show that the thermal resistance of the thermosyphon was one-half of that expected--0.2 K/W at a heat flow of 8.0 W. The design calculations also showed that this resistance can be made relatively constant over a wider range of heat flows by making the ratio of evaporator area to condenser area 3:1. The better-than-expected results will translate into reduced integration loss for the ZBO concept.

Plachta, David W.↗

A preliminary component analysis of a Mach-7 hypersonic vehicle

As research continues in the development of an aircraft capable of travelling at hypersonic flight velocities, both the propulsion and thermal management systems stand out as areas requiring innovative technological breakthroughs. For propulsion, the difficulty involves efficiently compressing and combusting hydrogen in a supersonic stream, i.e., developing a viable scramjet with thermal management, the challenge lies in development of materials and active cooling systems capable of handling the enormous heat fluxes associated with hypersonic flight. This paper focuses on these problems and presents component designs for both an active cooling system and an all-external-compression scramjet. These systems are mated to a Mach-6 passenger cruise aircraft whose aerodynamic configuration was derived from an optimization of NASA windtunnel test results. The following outlines the development of the configuration and then focuses in on the design of the two component systems.

Source record↗

Thermostructural applications of heat pipes for cooling leading edges of high-speed aerospace vehicles

Heat pipes have been considered for use on wing leading edge for over 20 years. Early concepts envisioned metal heat pipes cooling a metallic leading edge. Several superalloy/sodium heat pipes were fabricated and successfully tested for wing leading edge cooling. Results of radiant heat and aerothermal testing indicate the feasibility of using heat pipes to cool the stagnation region of shuttle-type space transportation systems. The test model withstood a total seven radiant heating tests, eight aerothermal tests, and twenty-seven supplemental radiant heating tests. Cold-wall heating rates ranged from 21 to 57 Btu/sq ft-s and maximum operating temperatures ranged from 1090 to 1520 F. Follow-on studies investigated the application of heat pipes to cool the stagnation regions of single-stage-to-orbit and advanced shuttle vehicles. Results of those studies indicate that a 'D-shaped' structural design can reduce the mass of the heat-pipe concept by over 44 percent compared to a circular heat-pipe geometry. Simple analytical models for heat-pipe startup from the frozen state (working fluid initially frozen) were adequate to approximate transient, startup, and steady-state heat-pipe performance. Improvement in analysis methods has resulted in the development of a finite-element analysis technique to predict heat-pipe startup from the frozen state. However, current requirements of light-weight design and reliability suggest that metallic heat pipes embedded in a refractory composite material should be used. This concept is the concept presently being evaluated for NASP. A refractory-composite/heat-pipe-cooled wing leading edge is currently being considered for the National Aero-Space Plane (NASP). This concept uses high-temperature refractory-metal/lithium heat pipes embedded within a refractory-composite structure and is significantly lighter than an actively cooled wing leading edge because it eliminates the need for active cooling during ascent and descent. Since the NASP vehicle uses cryogenic hydrogen to cool structural components and then burns this fuel in the combustor, hydrogen necessary for descent cooling only, when the vehicle is unpowered, is considered to be a weight penalty. Details of the design of the refractory-composite/heat-pipe-cooled wing leading edge are currently being investigated. Issues such as thermal contact resistance and thermal stress are also being investigated.

Camarda, Charles J.↗