Search NASASearch

SEARCH · Search NASA

Results for “Activity detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radio detection of thunderstorm activity with an earth-orbiting satellite

A study was made to determine the feasibility of using artificial earth satellites to monitor thunderstorm activity. The nighttime noise-temperature measurements made with the earth-oriented vee antenna of the Radio Astronomy Explorer (RAE 1) satellite in the frequency range 0.2-9.2 MHz were correlated with reported surface thunderstorm activity. Analysis shows that the minimum nighttime HF noise level (in the absence of surface thunderstorms) at an altitude of 5850 km over the United States is fixed by man-made noise. When thunderstorms are active below the satellite, the noise level is increased by about 6-12 dB. The highest level is associated with the most intense storms. It is concluded that thunderstorm regions can be detected by an orbiting satellite using HF radio techniques, but ionospheric effects must be taken into account.

Herman, J. R.

First Measurement of Deeply Virtual Compton Scattering on the Neutron with Detection of the Active Neutron

Measuring deeply virtual Compton scattering (DVCS) on the neutron is one of the necessary steps to understand the structure of the nucleon in terms of generalized parton distributions (GPDs). Neutron targets play a complementary role to transversely polarized proton targets in the determination of the GPD E . This poorly known and poorly constrained GPD is essential to obtain the contribution of the quarks’ angular momentum to the spin of the nucleon. DVCS on the neutron was measured for the first time selecting the exclusive final state by detecting the neutron, using the Jefferson Lab longitudinally polarized electron beam, with energies up to 10.6 GeV, and the CLAS12 detector. The extracted beam-spin asymmetries, combined with DVCS observables measured on the proton, allow a clean quark-flavor separation of the imaginary parts of the Compton form factors H and E . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The use of a spaceflight-compatible device to perform WBC surface marker staining and whole-blood mitogenic activation for cytokine detection by flow cytometry

Significant changes have recently been described regarding circulating peripheral immune cells immediately following spaceflight. Existing methods for immunophenotype staining of peripheral blood in terrestrial labs do not meet the constraints for flight on the Space Shuttle. We have recently described the development and use of the Whole Blood Staining Device (WBSD), a simple device for staining flow cytometry specimens during spaceflight. When preparing samples with the WBSD, all liquids are safely contained as the cells are moved through staining, lysis and fixation steps. Here we briefly review the use of the WBSD, and then describe another versatile adaptation, a modification to perform intracellular staining of cytokines for detection by flow cytometry. Alterations in cytokine production have been reported both in ground-based simulated microgravity culture and in astronaut samples returning from spaceflight. Data regarding microgravity effects on cytokine production for specific subpopulations of cells is lacking. Flow cytometric cytokine analysis offers the unique ability to perform simultaneous surface marker analysis and positively identity cytokine producing subsets of cells. The utilization of the WBSD provides the ability to perform rapid and routine mitogenic activation during spaceflight coupled with the ability to perform simultaneous surface marker analysis. The only external requirements for this procedure are an in-flight 37-degree incubator and the capacity for 4-degree storage.

NASA Discipline Regulatory Physiology

Detection of emetic activity in the cat by monitoring venous pressure and audio signals

To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

A Nagahara

Detection sensitivities in 3-8 MeV neutron activation

Study of detection sensitivities of 73 radioactive elements using fast unmoderated neutrons includes experiments for irradiation, cooling and counting conditions. The gamma ray emission spectra is used to identify the unknown material.

Wahlgren, M. A.

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly

Old Faithful Model for Radiolytic Gas-Driven Cryovolcanism at Enceladus

A new model is presented on how chemically driven cryovolcanism might contribute to episodic outgassing at the icy moon Enceladus and potentially elsewhere including Europa and Kuiper Belt Objects. Exposed water ices can become oxidized from radiolytic chemical alteration of near-surface water ice by space environment irradiation. In contact with primordially abundant reductants such as NH3, CH4, and other hydrocarbons, the product oxidants can react exothermically to produce volatile gases driving cryovolcanism via gas-piston forces on any subsurface liquid reservoirs. Radiolytic oxidants such as H2O2 and O2 can continuously accumulate deep in icy regoliths and be conveyed by rheological flows to subsurface chemical reaction zones over million-year time scales indicated by cratering ages for active regions of Enceladus and Europa. Surface blanketing with cryovolcanic plume ejecta would further accelerate regolith burial of radiolytic oxidants. Episodic heating from transient gravitational tides, radioisotope decay, impacts, or other geologic events might occasionally accelerate chemical reaction rates and ignite the exothermic release of cumulative radiolytic oxidant energy. The time history for the suggested "Old Faithful" model of radiolytic gas-driven cryovolcanism at Enceladus and elsewhere therefore consists of long periods of chemical energy accumulation punctuated by much briefer episodes of cryovolcanic activity. The most probable sequence for detection of activity in the current epoch is a long evolutionary phase of slow but continuous oxidant accumulation over billions of years followed by continuous but variable high activity over the past 10(exp 7)-10(exp 8) years. Detectable cryovolcanic activity could then later decline due to near-total oxidation of the rheologically accessible ice crust and depletion the accessible reductant abundances, as may have already occurred for Europa in the more intense radiation environment of Jupiter's magnetosphere. Astrobiological potential of Enceladus could correspondingly be higher than at Europa due to a less extreme state of oxidation and greater residual abundance of organics.

Cooper, John F.

Biological instrumentation for the Viking 1975 mission to Mars.

A brief introduction is given on why Mars is of interest from a biological point of view, along with an overview of the Viking 1975 mission. Details are given about the four biology instruments aboard the spacecraft and the experiments for which they are to be used. These are: the carbon assimilation experiment to determine whether the soil is biologically active; the label release experiment to detect metabolic activity by the release of radioactive CO2 from C-14 labelled simple organic substrates; the gas exchange experiment to detect biological activity by repeated gas chromatography analysis of soil samples; and the light scattering experiment, where increase of scattering and decrease of light transmission would indicate the growth of organisms. Examples are given of data obtained with terrestrial soils in these experiments.

Klein, H. P.

Future directions for H sub x O sub y detection

The activities and recommendations of the NASA workshop on the Future Directions for H sub x O sub y detection are given. The objective of this workshop was to access future directions for the measurement of the OH radical as well as other H sub x O sub y species. The workshop discussions were focused by two broad questions: (1) What are the capabilities of potential measurement methods? and (2) Will the results from the most promising method be useful in furthering understanding of tropospheric chemistry?

Crosley, David R.

Mars Sample Return orbital rendezvous detection methods

Navigation trades while in pursuit of a rendezvous with a sample capsule in orbit around Mars are described. The rendezvous operation is described in terms of far-field and near-field detection. Passive optical detection is compared with active capsule detection using a radio beacon. Passive methods are, to first order, unconstrained by time while a radio beacon link is time-limited. A possible activity to make use of orbiter plume interactions is explored.

Gustafson, Eric D.

An overview of a tether deployment monitoring system

A study was conducted to investigate the feasibility of monitoring the position of a tether during tether deployment. Several major configurations were investigated, including considerations of passive or active optical detection, radar, lidar, and active instrumentation packages. Cost, weight, the impact on tether operational dynamics, and the orbiter integration considerations were studied for each of these methods. Results indicated that implementation of such a monitoring system can be accomplished with little or no impact on tether deployment operations. Design diagrams are presented for two launchers and a tether attitude/tension detector.

Ibanez, P.

Model-based fault detection and isolation for intermittently active faults with application to motion-based thruster fault detection and isolation for spacecraft

The present invention is a method for detecting and isolating fault modes in a system having a model describing its behavior and regularly sampled measurements. The models are used to calculate past and present deviations from measurements that would result with no faults present, as well as with one or more potential fault modes present. Algorithms that calculate and store these deviations, along with memory of when said faults, if present, would have an effect on the said actual measurements, are used to detect when a fault is present. Related algorithms are used to exonerate false fault modes and finally to isolate the true fault mode. This invention is presented with application to detection and isolation of thruster faults for a thruster-controlled spacecraft. As a supporting aspect of the invention, a novel, effective, and efficient filtering method for estimating the derivative of a noisy signal is presented.

Wilson, Edward

Detection system ensures positive alarm activation in digital message loss

Lost Word Detection System /LOWDS/ provides special identification for each error detection message transmitted from receiver to transmitter. The message is identified as an original message or an n-times retransmitted message so the receiver can detect where a retransmission request was not fulfilled and activate an alarm.

Bokros, P.