Search NASASearch

SEARCH · Search NASA

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Direct Monitoring of Trace Atmospheric Species via Ion Trap Mass Spectrometry

There is an ever-increasing emphasis on the part of government agencies, academia, and industry on enhancing our understanding of atmospheric processes and assessing the impact of human activities on these processes. While issues such as the ozone hole and rising levels of greenhouse gases have received major attention. relatively little is known about the types, concentrations, sources, and sinks of hydrocarbons in the troposphere and stratosphere. Such information would be of tremendous utility in assessing the roles of various anthropogenic and biogenic processes on global carbon cycles. An ion trap mass spectrometer has been developed for monitoring trace levels of hydrocarbons in the atmosphere on NASA's DC-8 "flying laboratory". This aircraft is used to provide measurements in support of a number of "Mission to Planet Earth" activities and tropospheric chemistry experiments. In past missions, specific compounds have been monitored via highly specialized instrumentation, fast GO, or collection of whole air samples for subsequent ground-based analysis. The ion trap has several features. including small size. excellent sensitivity, and broad applicability, which make it highly atttrat:ive for atmospheric monitoring. The design of this instrument, its air sampling interface. and the various complications associated with aircraft-deployment will be described. Data showing the sensitivity of the instrument for detecting hydrocarbons at mixing ratios below one part-per-billion, and the use of MS/MS for direct, on-line, real-time monitoring will be presented.

Palmer, P. T.

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp

Dynamics of airborne fungal populations in a large office building

The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.

NASA Program Biomedical Research and Countermeasur

Nitric oxide measurements at a nonurban eastern United States site - Wallops instrument results from July 1983 GTE/CITE mission

The NASA Goddard Space Flight Center/Wallops Flight Facility nitric oxide detector used in the July 1983 GTE/CITE 1 instrument intercomparison is a chemiluminescence system which, at that time, had a detection limit of about 2 pptv (S/N = 1) for 60-s integrations. A substantial amount of NO concentration data was taken with this system at Wallops Island, VA, a site that should be typical of numerous nonurban coastal areas of the eastern United States and for which little other data are available. Midday concentrations under conditions of northwest winds averaged about 200 pptv, a value low enough to imply lower NO(x) amounts than are generally thought to exist in the eastern United States. During a 2-day period when the sampled air had spent 1-2 days over the Atlantic Ocean, average NO concentrations of 70 and 33 ptv were observed. Measurements at night indicated an average NO concentration of 16 pptv under wind conditions making contamination of the sampled air by local anthropogenic sources unlikely.

Torres, A. L.

Space Shuttle solid rocket motor exposure monitoring

During the processing of the Space Shuttle Solid Rocket Booster (SRB), segments at the Kennedy Space Center, an odor was detected around the solid propellant. An Industrial Hygiene survey was conducted to determine the chemical identity of the SRB offgassing constituents. Air samples were collected inside a forward SRB segment and analyzed to determine chemical composition. Specific chemical analysis for suspected offgassing constituents of the propellant indicated ammonia to be present. A gas chromatograph mass spectroscopy (GC/MS) analysis of the air samples detected numerous high molecular weight hydrocarbons.

Brown, S. W.

Long term trend of selected halogenated hydrocarbons

The so-called 'Library of Background Air' at the Oregon Graduate Institute was used to determine the trend in volume mixing ratios of selected halogenated hydrocarbons in the time period 1977-1989. This library consists of background air samples most of them taken at Cape Meares (Oregon). For storage stainless steel containers are used. Tests have shown the gases under consideration to be stable in these containers. Analyses using a GC/MS-system were performed for the CFCs 11, 12, 12B1 (HALON 1211, CBrClF2), 22, 113, 114 and CH3Cl, CH3Br, CH3CCl3, CCl4. The advantage of this unique investigation: different aged air samples are analyzed at the same time with the same instrument. No calibrations or intercalibrations are needed. All data are presented in normalized mixing ratios versus time. We discuss the results, derive rate constants and present a formula to describe the nonlinear increases.

Borchers, R.

Toxicological Assessment of the International Space Station Atmosphere

Space-faring crews must have safe breathing air throughout their missions to ensure adequate performance and good health. Toxicological assessment of air quality depends on the standards that define acceptable air quality, measurements of pollutant levels during the flight, and reports from the crew on their in-flight perceptions of air quality. Air samples from ISS flight 2A showed that contaminants in the Zarya module were at higher concentrations than the Unity module. At the crew's first entry, the amount of non-methane volatile organic compounds (NMVOCs) in Zarya was 23 Mg/cubic meter, whereas in the amount of NMVOCs in Unity was 5.3 mg/cubic meter. Approximately 26 hours later at egress from the modules, the NMVOCs were comparable indicating good mixing of the atmospheres. The 2A crew reported no adverse health effects related to air pollution during their flight. Ingress air samples from 2A.1, which was flown more than 5 months after 2A, again showed that the Zarya had accumulated more unscrubbed pollutants than Unity. The NMVOCs in Unity were 3.5 mg/cubic meter, whereas the were 20 mg/cubic meter in Zarya. After almost 80 hours of ISS operations, the NMVOCs were 7.5 and 12 mg/cubic meter in Unity and Zarya, respectively. This suggests that the atmospheres in the modules were not mixing very well. The 2A.1 crew felt that the air quality in Zarya deteriorated when they were working in a group at close quarters, when the panels had been removed, and after they had worked in an area for some time. The weight of evidence suggests that human metabolic products (carbon dioxide, water vapor, heat) were not being effectively removed from the crew's work area, and these caused their symptoms. Additional local measurements of pollutants are planned for the 2A.2 mission to the ISS.

James, John T.

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.

Use of the Aromascan(TM) Instrument for Nonsubjective Evaluation of Rodent Spaceflight Hardware

This report describes the verification and utilization of the AromaScan(TM) (Hollis, NH) instrument for the ground-based evaluation of odor containment by various spaceflight habitats developed at NASA's Ames Research Center (ARC). The AromaScan(TM) instrument is an electronic odor detection system consisting of 32 polymer sensors that respond differentially to 10 different chemical groups present in an air sample. The AromaScan(TM) system also includes neural network software for constructing a database of known odors, against which an unknown odor can be compared. At present, the standard method for characterizing rodent odor containment during the development and testing of spaceflight hardware is the use of a human odor assessment panel. However, this can be a very time consuming and costly process, and the results are inherently subjective. The AromaScan(TM) system should produce more consistent and objective results, as well as a cost savings in the long term. To test and verify the AromaScan(TM) instrument, daily air samples will be collected from the exhaust port of rodent habitats, during experiment development tests, then injected into the instrument and used to create a database of recognizable odors. Human sniff tests will be performed in conjunction with the AromaScan(TM) analysis, and the results will be correlated. We will then teach the neural network to differentiate between an acceptable and an unacceptable odor profile, as defined by the human sniff test, and to be able to accurately identify an odor that would not pass a sniff panel. The results of our efforts will be to verify that the AromaScan(TM) system is a valuable alternative to human sniff panel assessments for the early iterative process of designing and testing rodent waste filters for spaceflight. Acceptance by a human panel will remain one of the final criteria for successful rodent habitat development.

Scribner, K. A.

Analysis of Volatile Compounds from CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles

Analysis of Volatile Compounds From CO2 Removal Systems

One of the primary concerns when designing CO2 scrubber systems that will be integrated with a Sabatier reactor to produce water and methane is the amount of water released from the scrubber. Because the gas stream entering a Sabatier reactor must be compressed, water entering the reactor can condense and compromise the integrity of the system, thus rendering its valuable conversion capability useless. When the Johnson Space Center Environmental Chemistry Laboratory was tasked to develop an assay to quantify the water concentration in air samples from CO2 scrubbers, additional testing was also performed to see if any other compounds were being concentrated on the scrubbers. It was thought that the efficiency of the scrubber systems could be quantified by comparing the differences in samples from the ambient air on the International Space Station (ISS) to the exit gas of the scrubber. As this analysis was carried out, it became evident that the concentrations of certain volatile compounds were higher in the samples from the scrubbers than they were in nominal environmental samples. This meant these compounds were being retained and concentrated on the scrubber beds. Based on this finding, concerns were raised about their potential for these compounds to poison the Sabatier reactor. Further investigation was required to identify these compounds due to their high concentrations and unique matrix of the CO2 scrubber exhaust. This paper describes these events as well as the process that was developed to identify the volatile compounds that increased. An examination of how much the certain compounds can be concentrated by the scrubber systems is also included.

Volatiles

Components Refurbishment and Chemical Analysis Facility Hot Spot 1 Year 2 Annual Performance Monitoring Report

The Performance Monitoring Report presents the Year 2 operations, maintenance, and monitoring (OM&M) activities for the hydraulic containment system (HCS) Interim Measures (IM) at the Components Refurbishment and Chemical Analysis (CRCA) Facility located at John F. Kennedy Space Center (KSC), Florida. Year 2 operations extended from September 2020 to August 2021 and included: operation, maintenance and monitoring of the HCS; performance monitoring through collection of groundwater samples; and sub-slab gas and ambient air sampling. The existing hydrogeologic model was also updated. The system is performing as designed, and groundwater data demonstrate contaminant reduction.

CRCA

Toxicological Risks During Human Space Exploration

The goal of toxicological risk assessment of human space flight is to identify and quantify significant risks to astronaut health from air pollution inside the vehicle or habitat, and to develop a strategy for control of those risks. The approach to completing a toxicological risk assessment involves data and experience on the frequency and severity of toxicological incidents that have occurred during space flight. Control of these incidents depends on being able to understand their cause from in-flight and ground-based analysis of air samples, crew reports of air quality, and known failures in containment of toxic chemicals. Toxicological risk assessment in exploration missions must be based on an evaluation of the unique toxic hazards presented by the habitat location. For example, lunar and Martian dust must be toxicologically evaluated to determine the appropriate control measures for exploration missions. Experience with near-earth flights has shown that the toxic products from fires present the highest risk to crew health from air pollution. Systems and payload leaks also present a significant hazard. The health risk from toxicity associated with materials offgassing or accumulation of human metabolites is generally well controlled. Early tests of lunar and Martian dust simulants have shown that each posses the potential to cause fibrosis in the lung in a murine model. Toxicological risks from air pollutants in space habitats originate from many sources. A number of risks have been identified through near-earth operations; however, the evaluation of additional new risks present during exploration missions will be a challenge.

James, John T.

Microbial Monitoring of Astromaterials Curation Labs Reveals Inter-Lab Diversity

The Astromaterials Curation Division at NASA’s Johnson Space Center houses seven sample collections stored in separate clean rooms to avoid cross-contamination. Prior to receiving new sample collections from carbon rich asteroids, we instituted a monitoring program to characterize the microbial ecology of these labs and to understand how organisms could interact with and potentially contaminate current and future collections. Methods: Beginning in Oct. 2017 we sampled the Meteorite (ISO 7 equivalent) and Pristine Lunar (ISO 5 equivalent) labs on a monthly basis. Surface samples were collected using dry swabs. Air samples were collected using an impactor style air sampler. Cultivable organisms were identified and characterized. Aliquots of each sample were also preserved for DNA sequencing. For each sampling event recovery rate was calculated as the percentage of samples showing microbial growth1. Fungal colonies were selected for amino acid extraction and analysis via Ultra- Performance Liquid Chromatography with Fluorescence Detection and Mass Spectrometry.

Regberg, A. B.

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Summer 2015 Internship Abstract

Green fluorescent protein (GFP) visually shows the expression of proteins by fluorescing when exposed to certain wavelengths of light. The GFP in this experiment was used to identify cells actively releasing viruses. The experiment focused on the effect of microgravity on the GFP expression of Akata B-cells infected with Epstein Barr Virus (EBV). Two flasks were prepared with 30 million cells each and two bioreactors were prepared with 50 million cells each. All four cultures were incubated for 16 days and fed every four days. Cellometer readings were taken on the feeding days to find cell size, viability, and GFP expression. In addition, the cells were treated with Propodium monoazide (PMA) and run through real time PCR to determine viral load on the feeding days. On the International Space Station air samples are taken to analyze the bacterial and fungal organisms in the air. The Sartorius Portable Airport is being investigated for potential use on the ISS to analyze for viral content in the air. Multiple samples were taken around Johnson Space Center building 37 and in Clear Lake Pediatric Clinic. The filter used was the gelatin membrane filter and the DNA was extracted directly from the filter. The DNA was then run through real time PCR for Varicella Zoster Virus (VZV) and EBV as well as GAPDH to test for the presence of DNA. The results so far have shown low DNA yield and no positive results for VZV or EBV. Further inquiry involves accurately replicating an atmosphere with high viral load from saliva as would be found on the ISS to run the air sampler in. Another line of research is stress hormones that may be correlated to the reactivation of latent viruses. The stress hormones from saliva samples are analyzed rather than blood samples. The quantity found in saliva shows the quantity of the hormones actually attached to cells and causing a reaction, whereas in the blood the quantity of hormones is the total amount released to cause a reaction. The particular hormones tested for were cortisol, alpha-amylase, and DHEA. The DHEA was very high in the two control samples tested. Regularly, samples came into the lab from local clinics to be tested for various viruses. Saliva, blood, body scrapes, and tears were received from the clinics and then run for VZV, EBV, and Human Simplex Virus 1 (HSV-1) with the results then reported back to the clinician. Blood, saliva, and urine from astronauts were also tested for viruses and logged. In addition, several cell cultures were brought up and grown, including adherent Human Lung Fibroblast (HFL) cells infected with VZV, and Akata B-cells infected with EBV.

Smith, Courtney

Combination syringe provides air-free blood samples

Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

Pool, S. L.