Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A vacuum tube vee-trough collector for solar heating and air conditioning applications

An analysis is conducted of the performance of a vee-trough vacuum tube collector proposed for use in solar heating and cooling applications. The vee-trough reflector is a triangular sectioned, flat surfaced reflector, whose axis is laid in the East-West direction. A vacuum tube receiver placed at the bottom of the vee-trough collects solar heat most efficiently since convection is completely eliminated. Radiation losses are reduced by use of selective coatings on the absorber. Owing to its high temperature capabilities (300-400 F), the proposed scheme could also be used for power generation applications in combination with an organic Rankine conversion system. It is especially recommended for unattended pumping stations since the reflectors only require reversal once every six months.

Selcuk, M. K.↗

Air-Conditioning for Electric Vehicles

Combination of ammonia-absorption refrigerator, roof-mounted solar collectors, and 200 degrees C service electric-vehicle motor provides evaporative space-heating/space cooling system for electric-powered and hybrid fuel/electric vehicles.

Popinski, Z.↗

Study and development of an air conditioning system operating on a magnetic heat pump cycle (design and testing of flow directors)

This report describes the fabrication, design of flow director, fluid flow direction analysis and testing of flow director of a magnetic heat pump. The objectives of the project are: (1) to fabricate a demonstration magnetic heat pump prototype with flow directors installed; and (2) analysis and testing of flow director and to make sure working fluid loops flow through correct directions with minor mixing. The prototype was fabricated and tested at the Development Testing Laboratory of Kennedy Space Center. The magnetic heat pump uses rear earth metal plates rotate in and out of a magnetic field in a clear plastic housing with water flowing through the rotor plates to provide temperature lift. Obtaining the proper water flow direction has been a problem. Flow directors were installed as flow barriers between separating point of two parallel loops. Function of flow directors were proven to be excellent both analytically and experimentally.

Wang, Pao-Lien↗

Plant Growth Module (PGM) conceptual design

The Plant Growth Module for the Controlled Ecological Life Support System (CELSS), designed to answer basic science questions related to growing plants in closed systems, is described functionally with artist's conception drawings. Subsystems are also described, including enclosure and access; data acquisition and control; gas monitor and control; heating, ventilation, and air conditioning; air delivery; nutrient monitor and control; microbial monitoring and control; plant support and nutrient delivery; illumination; and internal operations. The hardware development plan is outlined.

Schwartzkopf, Steven H.↗

Air regenerating and conditioning

Various physicochemical methods of regenerating and conditioning air for spacecraft are described with emphasis on conditions which affect efficiency of the system. Life support systems used in closed, hermetically sealed environments are discussed with references to actual application in the Soviet Soyuz and Voskhod manned spacecraft. Temperature and humidity control, removal of carbon dioxide, oxygen regeneration, and removal of bacteria and viruses are among the factors considered.

Grishayenkov, B. G.↗

Heat Pipe Precools and Reheats Dehumidified Air

Precooling and reheating by heat pipe reduces operating costs of air-conditioning. Warm air returned from air-conditioned space and cooled air supplied are precooled and reheated, respectively, by each other through a heat pipe. Heat-pipe technology brought to bear on problem of conserving airconditioning energy in hot, humid environments. Any increase in the cost of equipment due to installation of heat-pipe heat exchangers expected to be recovered in energy savings during service period of 2 years or less.

Koning, R. C.↗

Analytic and experimental evaluation of flowing air test conditions for selected metallics in a shuttle TPS application

A detailed experimental and analytical evaluation was performed to define the response of TD nickel chromium alloy (20 percent chromium) and coated columbium (R512E on CB-752 and VH-109 on WC129Y) to shuttle orbiter reentry heating. Flight conditions important to the response of these thermal protection system (TPS) materials were calculated, and test conditions appropriate to simulation of these flight conditions in flowing air ground test facilities were defined. The response characteristics of these metallics were then evaluated for the flight and representative ground test conditions by analytical techniques employing appropriate thermochemical and thermal response computer codes and by experimental techniques employing an arc heater flowing air test facility and flat face stagnation point and wedge test models. These results were analyzed to define the ground test requirements to obtain valid TPS response characteristics for application to flight. For both material types in the range of conditions appropriate to the shuttle application, the surface thermochemical response resulted in a small rate of change of mass and a negligible energy contribution. The thermal response in terms of surface temperature was controlled by the net heat flux to the surface; this net flux was influenced significantly by the surface catalycity and surface emissivity. The surface catalycity must be accounted for in defining simulation test conditions so that proper heat flux levels to, and therefore surface temperatures of, the test samples are achieved.

Schaefer, J. W.↗

Analysis of A Severe Dust Storm and Its Impact on Air Quality Conditions Using Wrf-Chem Modeling, Satellite Imagery, and Ground Observations

This study presents a comprehensive analysis of an extreme dust event recorded in the Arabian Peninsula and the United Arab Emirates (UAE) between 31 March and 3 April 2015. Simulations of the dust event with the Weather Research and Forecasting model coupled with the Chemistry module (WRF-Chem) were analyzed and verified using MSG-SEVIRI imagery and aerosol optical depth (AOD) from the recent 1-km Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm for MODIS Terra/Aqua. Data from the National Centers for Atmospheric Prediction/National Center for Atmospheric Research (NCEP/NCAR) and the upper-air radiosonde observations were used to understand the synoptic of the event. In addition, the impact of the event on atmospheric and air quality conditions is investigated. The Air Quality Index (AQI) was calculated prior, during, and after the event to assess the degradation of air quality conditions. Simulated temperature, relative humidity, wind speed, and surface radiation were compared to observations at six monitoring stations in the UAE giving R2 values of 0.84, 0.63, 0.60, and 0.84, respectively. From 1 to 2 April 2015, both observations and simulations showed an average drop in temperature from 33 to 26 °C and radiance reduction from about 950 to 520 Wm−2. The AOD modeled by WRF-Chem showed a good correlation with Aerosol Robotic Network (AERONET) measurements in the UAE with R2 of 0.83. The AQI over the UAE reached hazardous levels during the peak of the dust event before rapidly decreasing to moderate–good air quality levels. This work is the first attempt to demonstrate the potential of using WRF-Chem to estimate AQI over the UAE along with two satellite products (MODIS-MAIAC and MSG-SEVIRI) for dust detection and tracking.

dust storm↗

Fabrication of diatomite‐based microencapsulated flame retardant and its improved fire safety of unsaturated polyester resin

To achive excellent fire resistance, new microcapsule flame retardants (DMCAD and DMPPD) were prepared using 9,10‐dihydro‐9‐oxa‐10‐phosphaphenanthrene‐10‐oxide combined with melamine cyanurate or melamine polyphosphate as the shell material and diatomite as the core material. The successful assembly of DMCAD and DMPPD was detailed characterized by Fourier transform infrared (FT‐IR) spectra, X‐ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM). Meanwhile, the flame retardancy and thermal stability of the unsaturated polyester resin (UPR)/DMCAD and UPR/DMPPD composites were also studied. The addition of DMCAD and DMPPD effectively improves the flame retardance properties of UPR, and the effect of DMPPD was better. The limiting oxygen index (LOI) of UPR/DMPPD‐3 increased by 11.6% when compared with that of UPR, and the sample achieved V‐0 rating. Moreover, the peak heat release rate (pHRR) and the total heat release (THR) rate of UPR/DMPPD‐3 were reduced by 67% and 26%, respectively. Under nitrogen condition and air condition, UPR/DMPPD showed better thermal stability and char‐forming ability from the thermogravimetric (TG) results. Residual char of the UPR composites was systematically analyzed with SEM and XPS. Finally, the flame retardant mechanism of DMPPD was proposed.

Chen, Gang↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations of the convective plume of a lake under cold-air advective conditions

Moderating effects of Lake Apopka, Florida, on downwind surface temperatures were evaluated under cold-air advective conditions. Point temperature measurements north and south of the lake and data obtained from a thermal scanner flown at 1.6 km indicate that surface temperatures directly downwind may be higher than surrounding surface temperatures by as much as 5 C under conditions of moderate winds (about 4 m/s). No substantial temperature effects were observed with surface wind speed less than 1 m/s. Fluxes of sensible and latent heat from Lake Apopka were calculated from measurements of lake temperature, net radiation, relative humidity, and air temperature above the lake. Bulk transfer coefficients and the Bowen ratio were calculated and found to be in agreement with reported data for nonadvective conditions.

Bill, R. G., Jr.↗

Comparison of chromium poisoning between lanthanum strontium manganite and lanthanum strontium ferrite composite cathodes in solid oxide fuel cells

Degradation mechanisms of chromium poisoning have been extensively investigated for last two decades on various cathode materials for solid oxide fuel cells. While most researchers used half-cell experiments to investigate the effects of chromium impurities, this paper compares the degradation phenomena of LSM-YSZ and LSF-GDC cathodes in full cells under different operating conditions, namely polarized current density and humidity over the cathode. Under cathodic load, performance degradation of LSF-GDC cathode is significantly less than that of LSM-YSZ cathode. Most interestingly, under humidified air condition, LSF-based cell hardly experiences performance degradation while LSM-based cell shows a catastrophic degradation. Cr deposition in LSM-based cells occurs mainly near the electrolyte under both dry and humidified air conditions. In contrast, Cr deposition in LSF-based cell concentrates at the cathode surface under dry air condition, but concentrates both at cathode surface and near electrolyte under humidified air condition. Microstructure analysis reveals Mn-associated Cr deposits in LSM-based cathode, and Sr- and Fe-associated Cr deposits in LSF-based cathode. With the help of distribution of relaxation time analysis, the different electrochemical behaviors of LSM- and LSF-based cells are carefully interpreted. The effects of electrochemical deposition, Sr surface segregation, and humidity on LSM- and LSF-based cathodes are discussed.

25 ENERGY STORAGE↗