Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Discussion of band selection and methodologies for the estimation of precipitable water vapour from AVIRIS data

An Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data set acquired over Canal Flats, B.C., on 14 Aug. 1990, was used for the purpose of developing methodologies for surface reflectance retrieval using the 5S atmospheric code. A scene of Rogers Dry Lake, California (23 Jul. 1990), acquired within three weeks of the Canal Flats scene, was used as a potential reference for radiometric calibration purposes and for comparison with other studies using primarily LOWTRAN7. Previous attempts at surface reflectance retrieval indicated that reflectance values in the gaseous absorption bands had the poorest accuracy. Modifications to 5S to use 1 nm step size, in order to make fuller use of the 20 cm(sup -1) resolution of the gaseous absorption data, resulted in some improvement in the accuracy of the retrieved surface reflectance. Estimates of precipitable water vapor using non-linear least squares regression and simple ratioing techniques such as the CIBR (Continuum Interpolated Band Ratio) technique or the narrow/wide technique, which relate ratios of combinations of bands to precipitable water vapor through calibration curves, were found to vary widely. The estimates depended on the bands used for the estimation; none provided entirely satisfactory surface reflectance curves.

Schanzer, Dena↗

Summaries of the Seventh JPL Airborne Earth Science Workshop January 12-16, 1998: AVIRIS Workshop - Volume 1

This publication contains the summaries for the Seventh JPL Airborne Earth Science Workshop, held in Pasadena, California, on January 12-16, 1998. The main workshop is divided into three smaller workshops, and each workshop has a volume as follows: (1) Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Workshop; (2) Airborne Synthetic Aperture Radar (AIRSAR) Workshop; and (3) Thermal Infrared Multispectral Scanner (TIMS) Workshop. This Volume 1 publication contains 58 papers taken from the AVIRIS workshop.

Robert O Green↗

Geologic remote sensing - New technology, new information

Results of geologic studies using data collected by the NASA/JPL Thermal Infrared Imaging Spectrometer (TIMS), Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and the Airborne Synthetic Aperture Radar (AIRSAR) are discussed. These instruments represent prototypes for the Earth Observing System (EOS) satellite instruments ASTER, High Resolution Imaging Spectrometer (HIRIS), and EOS SAR. Integrated analysis of this data type is one of the keys to successful geologic research using EOS. TIMS links the physical properties of surface materials in the 8-12-*mm region to their composition. Calibrated aircraft data make direct lithological mapping possible. AVIRIS, an analog for HIRIS, provides quantitative information about the surface composition of materials based on their detailed visible and infrared spectral signatures (0.4-2.45 mm). Calibrated AVIRIS data make direct identification of minerals possible. The AIRSAR provides additional complementary information about the surface morphology of rocks and soils.

Kruse, F. A.↗

Remote Sensing of Seasonal Leaf Area Index Across the Oregon Transect

Remotely sensed data acquired from four remote-sensing instruments on three different aircraft platforms over a transect of coniferous forest stands in Oregon were analyzed with respect to seasonal leaf area index (LAI). Data from the four instruments were corrected for the varying seasonal and geographic atmospheric conditions present along the transect. Strong logarithmic relationships were observed between seasonal maximum and minimum LAI and the simple ratio (SR) (near infrared/red reflectance) calculated from the broad-spectral-band Thematic Mapper Simulator (TMS), as well as from the narrow-spectral-band Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), the Compact Airborne Spectrographic Imager (CASI), and a Spectron SE590 spectro-radiometer (R(exp 2) = 0.82-0.97). The TMS SR reached an asymptote at an LAI of approx. 7-8. However, the SE590 and the CASI SR continued to increase up to the maximum LAI of 10.6. The variability of the relationship between the AVIRIS SR and LAI increased at stands with LAIs greater than 7, making a trend in the AVIRIS SR-LAI relationship at LAIs greater than 7 difficult to discern. The SRs of the coniferous forest stands measured by the narrow-spectral-band instruments were higher than they were from the broad-spectral-band TMS. This is attributed partially to the integration of the TMS over a broad wavelength region in the red and more strongly to calibration differences between the sensors. Seasonal TMS SR trends for four time periods for some of the stands deviated from the expected seasonal LAI trends, possibly because of smoke and very low sun angles during some of the acquisition periods. However, the expected SR differences for the seasonal minimum and maximum LAI were observed for all of the sensors for nearly all of the forest stands. This study, demonstrates that remotely, sensed data from both broad- and narrow spectral band instruments can provide estimates of LAI for use in forest ecosystems simulation models to estimate evapotranspiration, photosynthesis, canopy turnover, and net primary production over large areas.

Spanner, Michael↗

Volcanic thermal features observed by AVIRIS

In July 1991, Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) was flown over Mount Etna and Stromboli, Italy. Lava-filled vents were then present within summit craters of both volcanoes. Since surfaces at magmatic temperatures radiate strongly over the wavelength ranges of the AVIRIS C- and D-spectrometers, it was hoped that the data collected would reveal clear thermal signatures, even of sub-pixel sized features, as have been observed in the 1.65 and 2.22 microns bands of Landsat Thematic Mapper images. This would provide an opportunity to explore the potential of imaging spectrometers for deriving temperature distributions of hot volcanic surfaces. Such research has implications for volcano monitoring in the EOS era, and also for any future AVIRIS deployments above active lava flows, lakes, and domes, where understanding of their behavior may be advanced by detailed thermal observations.

Oppenheimer, Clive↗

Assessment of AVIRIS Laboratory and In-Flight Uniformity

An assessment of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) laboratory and in-flight uniformity is presented in this Slide presentation. The ideal uniform system is described, being a system where every spectrum is intercomparable to every other spectrum. Two types of failures to achieve this uniformity are described. Graphs showing measured spectral upwelling radiance, the expanded spectral convolution, the radiometric error from spectral error, the results from the hyperion Arizaro calibration experiment and a AVIRIS cross-track uniformity are among those presented. The reasons why uniformity matters are presented.

imaging spectroscopy↗

Radiometric Performance Model for AVIRIS

This slide presentation reviews the radiometric performance model for Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This model allows for an estimation of the signal throughput and noise properties of AVIRIS for the components. This understanding can point to areas for improvements of the components.. The signal to noise ratio properties may be estimated. An accurate radiometric performance model is essential for the use of existing instruments and the design of new instruments. Included in the presentation is a design view and a picture of the AVIRIS instrument. There is discussion of the signal, the signal area solid angle product, aspects of area solid angle time, the idealized radiometer photon calculation and noise both instrument read and photon counting noise. Graphs of signal throughput efficiency, input radiance, photons at the detector, signal e-, noise e- and the signal to noise ratio are presented.

imaging spectroscopy↗

Summaries of the Sixth Annual JPL Airborne Earth Science Workshop: AIRSAR Workshop - Volume 2

The Sixth Annual JPL Airborne Earth Science Workshop, held in Pasadena, California, on March 4-8, 1996, was divided into two smaller workshops:(1) The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) workshop, and The Airborne Synthetic Aperture Radar (AIRSAR) workshop. This current paper, Volume 2 of the Summaries of the Sixth Annual JPL Airborne Earth Science Workshop, presents the summaries for The Airborne Synthetic Aperture Radar (AIRSAR) workshop.

Kim, Yun-Jin↗

Design of a Pushbroom Imaging Spectrometer that Exceeds AVIRIS Performance

This slide presentation reviews the design of a Pushbroom Imaging Spectrometer, that will exceed the performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The approach for the AVIRIS-II instrument is reviewed as are the specifications for the new spectrometer. Even though the pushbroom spectrometer is inherently non-uniform, the design of the AVIRIS-II provides for uniformity. Spot diagrams at the slit and at the detector inside the 27micron box are presented. A few of the challenges in the mechanical design and the making of the slit are discussed. The specifications of the 6604A detector array are reviewed. Slides showing the expected Signal to Noise Ratio performance are presented.

Airborne Visible/Infrared Imaging Spectrometer (AV↗

Functional patterns in an annual grassland during an AVIRIS overflight

This study relates Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imagery to ground measurements of vegetation distribution, physiology, and productivity at Stanford University's Jasper Ridge Biological Preserve. Primary efforts focused on a 9-ha region of annual grassland where we completed a detailed ground-based study in conjunction with a 15 May 1991 AVIRIS overflight. Spectral mixture analysis and the normalized difference vegetation index (NDVI) calculated from AVIRIS data were used to evaluate spatial patterns of vegetation type, productivity, and potential physiological activity. Concurrent ground sampling revealed a high degree of correlation between NDVI and estimates of canopy chemistry, structure, productivity, and CO2 flux, supporting the use of imaging spectrometry to estimate spatial and temporal trends in vegetation physiology and productivity in this relatively simple grassland ecosystem. Geostatistical analyses of both ground and AVIRIS data supported the conclusion that the AVIRIS pixel size was suitable for describing the influence of major landscape features in this grassland and that spatial detail would be lost at slightly larger pixel sizes typical of other imaging spectrometers.

Gamon, John A.↗

AVIRIS Spectrometer Maps Total Water Vapor Column

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) processes maps of vertical-column abundances of water vapor in atmosphere with good precision and spatial resolution. Maps provide information for meteorology, climatology, and agriculture.

Conel, James E.↗

Proceedings of the 11th JPL Airborne Earth Science Workshop

This publication contains the proceedings of the JPL Airborne Earth Science Workshop forum held to report science research and applications results with spectral images measured by the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). These papers were presented at the Jet Propulsion Laboratory from March 5-8, 2001. Electronic versions of these papers may be found at the A VIRIS Web http://popo.jpl.nasa.gov/pub/docs/workshops/aviris.proceedings.html

Airborne Visible/Infrared Imaging Spectrometer (AV↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to Calibrate the Optical Sensor on Board the Japanese Earth Resources Satellite-1

In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

spaceborne↗

AVIRIS scan drive design and performance

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) images the ground with an instantaneous field of view (IFOV) of 1 mrad. The IFOV is scanned 30 deg from left to right to provide the cross-track dimension of the image, while the aircraft's motion provides the along-track dimension. The scanning frequency is 12 Hz, with a scan efficiency of 70 percent. The scan mirror has an effective diameter of 5.7 in, and its positional accuracy is a small fraction of a milliradian of the nominal position-time profile. Described are the design and performance of the scan drive mechanism. Tradeoffs among various approaches are discussed, and the reasons given for the selection of the cam drive.

Miller, D. C.↗

AVIRIS ground data-processing system

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been under development at JPL for the past four years. During this time, a dedicated ground data-processing system has been designed and implemented to store and process the large amounts of data expected. This paper reviews the objectives of this ground data-processing system and describes the hardware. An outline of the data flow through the system is given, and the software and incorporated algorithms developed specifically for the systematic processing of AVIRIS data are described.

Reimer, John H.↗