Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airflow distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Numerical Investigation of Combustor-Turbine Interactions with a Two-Stage High-Pressure Turbine Including Cooling Airflows

Combustor–turbine interactions (CTIs) are investigated by performing three-dimensional unsteady simulations using a realistic combustor and high-pressure turbine (HPT) configurations from the Energy Efficient Engine (E3) program. To understand CTIs, we compare the numerically predicted flow fields from single-component simulations (Step 1: the combustor + the first-stage stator of turbine; Step 2: the two-stage HPT imposing the time-averaged flow solution from Step 1 as the inflow boundary condition) and a fully coupled combustor–turbine simulation (Step 3) at the sea-level takeoff (SLTO) condition. In addition to three previous simulations where the cooling airflows inside the HPT had been neglected for all Step 1, Step 2, and Step 3, two new simulations of Step 2 and Step 3 take into account the cooling airflows using the source team approach. In this approach, to mimic the cooling airflows, we impose the source term at a specific area of a cooling airflow hole at the solid surfaces without making a mesh of each hole. The objective of this study is twofold. One is to investigate the effect of the presence of the cooling airflows on the aerodynamics of the combustor and HPT as well as the HPT performance. The second is to perform a detailed comparison among the calculated flowfields by two different numerical schemes, the central-difference with the standard Jameson–Schmidt–Turkel (CD-JST) scheme and the AUSM scheme. There is a noticeable difference in the hot-streak distributions at the first-stage stator. In addition, depending on the choice of the numerical scheme and the presence of the cooling airflows, an occurrence of shock waves appearing at the first-stage stator is greatly influenced. Thus, this has a noticeable impact on the HPT performance. It is shown that the estimated turbine efficiencies from Step 3 are about 7 % less than the ones from Step 2.

Combustor-turbine interaction↗

Orion Capsule Parachute Assembly System (CPAS) Overload Testing Approach and Results

The qualification of the Orion Capsule Parachute Assembly System (CPAS) system includes exposure to loads and dynamic pressures above the required values as validation of the parachutes' structural integrity. As outlined in the certification plan, each of the four parachutes of the system are to be subjected to 110% of their respective maximum dynamic pressure requirements. The Main and Drogue parachutes have satisfied this overload condition in drop testing and due to cost and schedule constraints, the Forward Bay Cover Parachute (FBCP) and Pilot parachute were subjected to the overload condition in the ground testing described in this document. The test objectives and pass/fail criteria were established and require the parachutes to achieve and maintain a target riser load (associated with a minimum of 110% dynamic pressure overload) for a minimum of three seconds while sustaining no failures of any structural members (vent hoop, radials, suspension line) or any damage which propagates into catastrophic failure of the canopy. Considering the assumptions and limitations associated with the ground testing (primarily non-uniform flow field of the ground test system and variations in parachute manufacturing), a method of establishing the desired overload condition was determined by the technical community and covers the 2-sigma bounds of the drag area distribution derived from drop testing. On June 27, 2017 the testing was executed at the High Velocity Airflow System (HiVAS) facility located at the Weapon Survivability Laboratory (WSL) at the Naval Air Warfare Center, Weapons Division (NAWCWD) China Lake. Engineering Development Unit (EDU) parachutes were used as pathfinders to gain experience with achieving the test conditions. Additional runs were executed to measure the airflow at the same location as the canopy skirt, although this data is not required to satisfy the test objectives and parachute pass/fail criteria. The qualification parachutes were successfully exposed to the target conditions and sustained only minor damage.

Daum, Jared S.↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This presentation presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the tunnel test section. Some icing spray clouds with large-sized drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a Pitot static probe affixed on the mounting plate. Those findings were later verified in the Icing Research Tunnel using a new Pitot probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations as airflow moving towards the probe head were run for a Langmuir-D 7-bin drop size distribution of a spray cloud with a nominally large value of medium volumetric diameter. The simulation results helped identify a critical drop-size threshold of 300 µm above which the velocities of larger drops are not affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Spacecraft particulate contaminant redistribution

This paper describes analyses that were performed in support of the Hubble Space Telescope (HST)) particulate contamination control effort. The specific problems addressed include extension of available particle removal data to launch acoustic and random vibration conditions, development of an engineering model for transport of suspended particulates by airflow and in the presence of vehicle acceleration, turbulent diffusion, and migration of particulates over vibrating surfaces, and integration of the various models into a code that could be used to generate contamination level estimates for the HST primary mirror and other critical surfaces for the HST mission phases. The overall redistribution calculations were made assuming a specified initial contaminant distribution in terms of MIL STD 1246A levels, and using predicted vibration data for the various HST surfaces and mission phases. As expected, the effects of airflow were found to be significant, particularly for the larger particles. Particles smaller than about 20 microns did not participate appreciably in the redistribution.

Klavins, A.↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of air distribution on dew point evaporative cooler thermal performance

A new geometry of the dew-point indirect evaporative cooler structure was proposed which enables uniform distribution of water in the working channels and application in traditional air handling units. This arrangement requires a complicated structure of the product channel in which the air is cooled. Further, the airflow direction changes and complicated structure it is associated with local losses affecting the total pressure loss. High-pressure drop limits the use of this dew point evaporative cooler as an alternative source of cooling. Therefore, a verified method based on numerical fluid dynamics (CFD) was used to determine the pressure drop and air distribution in the exchanger. The combination of the CFD method and modified epsilon-NTU allows the thermal performance of the device including the uniformity of air distribution, cooling capacity, and coefficient of performance to be determined. Finally, the appropriate exchanger dimensions, i.e., the channel height, or final distribution regulation may be found depending on the exchanger application.

42 ENGINEERING↗

The effect of preheat on the structure of a swirl stabilized flame

The effect of preheat on the temperature and species distributions in propane flames stabilized on a NASA contraswirl can has been examined. Flames with compact stable structure, inner-swirler airflow of 0.0091 kg/s, outer-swirler-plus-bypass airflow of 0.0203 kg/s, and propane injected 1 mm upstream of the inner swirler hub have been selected for detailed study. Over the inlet-air-temperature range from 300 to 673 K the maximum temperature in the flame increased by 40 to 60 K per 100-K increase in inlet air temperature. The point of maximum temperature on the center line approached the exit plane as inlet air temperature was increased. Oxygen, CO, H2, and methane were found together in gas samples taken from the flame, including the regions of maximum flame temperature.

Thompson, D.↗

The Oscillating Circular Airfoil on the Basis of Potential Theory

Proceeding from the thesis by W. Kinner the present report treats the problem of the circular airfoil in uniform airflow executing small oscillations, the amplitudes of which correspond to whole functions of the second degree in x and y. The pressure distribution is secured by means of Prandtl's acceleration potential. It results in a system of linear equations the coefficients of which can be calculated exactly with the aid of exponential functions and Hankel's functions. The equations necessary are derived in part I; the numerical calculation follows in part II.

Schade, T.↗

CFD Model of Water Droplet Transport for ISS Hygiene Activity

The goal of the study is to assess the impacts of free water propagation in the Waste and Hygiene Compartment (WHC). Free water can be generated inside the WHC in small quantities due to crew hygiene activity. To mitigate potential impact of free water in Node 3 cabin the WHC doorway is enclosed by a waterproof bump-out, Kabin, with openings at the top and bottom. At the overhead side of the rack, there is a screen that prevents large drops of water from exiting. However, as the avionics fan in the WHC causes airflow toward the deck side of the rack, small quantities of free water may exit at the bottom of the Kabin. A Computational Fluid Dynamics (CFD) analysis of Node 3 cabin airflow made possible to identify the paths of water transport. The Node 3 airflow was computed for several ventilation scenarios. To simulate the droplet transport the Lagrangian discrete phase approach was used. Various initial droplet distributions were considered in the study. The droplet diameter was varied in the range of 2-20 mm. The results of the computations showed that most of the drops fall to the rack surface not far from the WHC curtain. The probability of the droplet transport to the adjacent rack surface with electronic equipment was predicted.

Son, Chang H.↗

Forecasting Commercial Building Electricity Consumption, Zone Airflow and Zone Temperature: Update - Development of a Generalized Machine Learning Approach

The U.S. power grid is being transformed to make it smarter, more efficient, and cleaner. This transformation is leading to the addition of a significant of energy generated by distributed, variable, and renewable resources. Because of the variable nature of renewable generation, the short- and long-term supply and demand imbalances are less predictable, and conventional approaches to mitigating the imbalances will be less efficient or cost effective. To address this challenge and to support the mission and the vision of the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) Building Technologies Office has developed a Grid-Interactive Efficient Building Strategy. The strategy focuses on simultaneously improving building energy efficiency and supporting reliability and resilience of the electric grid more efficiently and at a lower cost. In addition, EERE and DOE’s Office of Electricity created an initiative led by DOE and supported by the national laboratories under the Grid Modernization Lab Consortium structure to enhance grid modernization. The work reported in this document is part of the first set of projects funded under the initiative to design, develop, and validate scalable transactive control technologies for the commercial buildings sector. Transactive controls requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical grey- and black-box models have been widely used to express flexibility. Although this approach is generally easy to construct and simple to use, it does not capture non-linear behavior that some end-use loads represent. Therefore, Pacific Northwest National Laboratory (PNNL) with support from Western Washington University conducted this research to explore the use of deep machine learning (ML) techniques. The work reported in this document is limited to forecasting whole building electricity consumption, the zone airflow and the zone temperature predictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel computational fluid dynamics - Implementations and results

The present volume on parallel CFD discusses implementations on parallel machines, numerical algorithms for parallel CFD, and performance evaluation and computer science issues. Attention is given to a parallel algorithm for compressible flows through rotor-stator combinations, a massively parallel Euler solver for unstructured grids, a fast scheme to analyze 3D disk airflow on a parallel computer, and a block implicit multigrid solution of the Euler equations. Topics addressed include a 3D ADI algorithm on distributed memory multiprocessors, clustered element-by-element computations for fluid flow, hypercube FFT and the Fourier pseudospectral method, and an investigation of parallel iterative algorithms for CFD. Also discussed are fluid dynamics using interface methods on parallel processors, sorting for particle flow simulation on the connection machine, a large grain mapping method, and efforts toward a Teraflops capability for CFD.

Simon, Horst D.↗

CFD Lagrangian Modeling of Water Droplet Transport for ISS Hygiene Activity Application

The goal of this study was to assess the impacts of free water propagation in the Waste and Hygiene Compartment (WHC) installed in Node 3. Free water can be generated inside the WHC in small quantities due to crew hygiene activity. To mitigate potential impact of free water in Node 3 cabin the WHC doorway is enclosed by a waterproof bump-out, Kabin, with openings at the top and bottom. At the overhead side of the rack, there is a screen that prevents large drops of water from exiting. However, as the avionics fan in the WHC causes airflow toward the deck side of the rack, small quantities of free water may exit at the bottom of the Kabin. A Computational Fluid Dynamics (CFD) analysis of Node 3 cabin airflow enable identifying the paths of water transport. To simulate the droplet transport the Lagrangian discrete phase approach was used. Various initial droplet distributions were considered in the study. The droplet diameter was varied in the range of 5-20 mm. The results of the computations showed that most of the drops fall to the rack surface not far from the WHC curtain.

Son, Chang H.↗

Measuring Airflow With Digital Holographic Interferometry

Digital image-processing system assists in analysis of holographic interferometric images of flow about airfoil. Operating semiautomatically, identifies, counts, and labels interference fringes, then processes distances between fringes into distribution of pressure on surface of airfoil. Yields data on pressure faster than manual image-analyses techniques, and data compares favorably with those obtained by manual analysis and by probe measurements of pressure. Uses computer programs evaluating interferograms along straight or curved lines represented by polygon segments. User prompted for such inputs as reference points and fringe number. Digitizes holographic interferograms of flow and processes them into data of pressure or other properties of flow.

Torres, Francisco J.↗

Design and development of the combustor inlet diffuser for the NASA/GE energy efficient engine

Results of an experimental investigation of the aerodynamic performance of a split duct annular combustor inlet diffuser system are presented. Several diffuser configurations were investigated in 3X-scale water table tests and the preferred design was evaluated in full-scale annular airflow model tests. Pressure recovery and flow losses were determined as a function of prediffuser inlet velocity profile, flow extraction at the prediffuser exit, and distribution of flow in the combustor. Inlet velocity profile and turbulence levels were found to have a pronounced effect on system performance. Flow extraction at the prediffuser exit was found to have little influence on system performance. Generally, the annular split duct diffuser system was found to satisfy the performance objectives for the engine.

Sabla, P. E.↗

Hamiltonian Control for Coupled Bending-Torsion Motion of a Swept Wing With R. T. Jones' Approximation

This paper presents distributed Hamiltonian control design approach for a Lagrangian infinite-dimensional system describing the coupled bending-torsion motion of a swept wing in unsteady airflow, which is taken into account using Theodorsen's complex valued function of reduced frequency. An implementable flutter suppressing control surface deflection commands are obtained using modes separation and R.T. Jones's approximation, and were validated in desktop simulations for flight conditions beyond the flutter airspeed.

Vahram Stepanyan↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flame characteristics of a NASA contra swirler module

Results are presented for an investigation of the structure of unconfined propane flames stabilized on a NASA contra-swirl can. General flame characterization, flame visualization by sodium chloride, temperature measurements, combustion products analysis, nitric oxide concentrations, and laser anemometer studies are considered. The results are discussed relative to sodium chloride visualization, temperature distributions, chemical composition of flames, nitric oxide distributions, and velocity distributions. It is shown that unconfined propane-air flames can be stabilized downstream of a NASA contra-swirl can under a wide range of airflow rates and fuel-air ratios. However, on increasing fuel input from the lowest at which flames can be stabilized, a compact recirculation zone-stabilized flame is formed. The effect of confinement on changes in flame shape and structure is determined.

Thompson, D.↗

Throat-bypass bleed systems for increasing the stable airflow range of a Mach 2.50 axisymmetric inlet with 40-percent internal contraction

The results of an experimental investigation to increase the stable airflow range of a super sonic mixed-compression inlet are presented. Various throat-bypass bleeds were located on the inlet cowl. The bleed types were distributed porous normal holes, a forward slanted slot, or distributed educated slots. Large inlet stability margins were obtained with the inlet throat bleed systems if a constant pressure was maintained in the throat-bypass bleed plenum. Stability limits were determined for steady-state and limited transient internal air flow changes. Limited unstart angle-of-attack data are presented.

Sanders, B. W.↗