Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis of Variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Variance components in confocal scanning laser tomography measurements of neuro‐retinal rim area and the effect of repeated measurements on the power to detect loss over time

Abstract Purpose To estimate the variation in measurements of neuro‐retinal rim area (NRA) determined by confocal scanning laser tomography and consequences for clinical follow‐up. Methods Altogether, 24 healthy subjects were randomized on –320 μ m, Moorfields and Standard NRA plane strategies. Additionally, NRA was measured in 32 glaucoma subjects. Variance components for subjects, visits and measurements were estimated with analysis of variance. Sample sizes required to detect a 6.0 × 10 −2 mm 2 NRA change were estimated assuming a significance level of 0.05 and a power of 0.8. Consequences for independent group, and paired comparison design, respectively, were analysed. Further, precision in estimates within subjects over time was investigated. Results The variation of NRA among subjects was considerably larger than the variation among visits and measurements. For glaucoma subjects, the variation among visits and measurements were of the same order but larger than in healthy subjects. It was found that independent group comparisons require inconveniently large sample sizes. Within‐subject paired comparisons over time require sample sizes of below 15 subjects. The estimated variations for glaucoma subjects imply that 54 months of follow‐up is required for detection of change from baseline. Conclusions The variance for subjects is substantial in relation to those for visits and measurements. Cross‐sectional independent group comparisons of levels of NRA are unsuitable, due to considerable subject variation. Levels of NRA differences within subjects between visits can be estimated with acceptable precision. Neuro‐retinal rim area (NRA) measurement can be used for long‐term follow‐up of glaucoma progression.

Sandberg Melin, Camilla↗

Elliptically-Contoured Tensor-variate Distributions with Application to Image Learning

Statistical analysis of tensor-valued data has largely used the tensor-variate normal (TVN) distribution that may be inadequate for data arising from distributions with heavier or lighter tails. We study a general family of elliptically contoured (EC) TV distributions and derive its characterizations, moments, marginal, and conditional distributions. We describe procedures for maximum likelihood estimation from data that are (1) uncorrelated draws from an EC distribution, (2) from a scale mixture of the TVN distribution, and (3) from an underlying but unknown EC distribution, for which we extend Tyler’s robust estimator. A detailed simulation study highlights the benefits of choosing an EC distribution over the TVN for heavier-tailed data. We develop TV classification rules using discriminant analysis and EC errors and show that they better predict cats and dogs from images in the Animal Faces-HQ dataset than the TVN-based rules. A novel tensor-on-tensor regression and TV analysis of variance (TANOVA) framework under EC errors is also demonstrated to better characterize gender, age, and ethnic origin than the usual TVN-based TANOVA in the celebrated labeled faces of the wild dataset.

97 MATHEMATICS AND COMPUTING↗

DOSE ASSESSMENT OF THE FINAL INVENTORIES IN CENTER SLIT TRENCHES ONE THROUGH FIVE

In response to a request from Solid Waste Management (SWM), this study evaluates the performance of waste disposed in Slit Trenches 1-5 by calculating exposure doses and concentrations. As of 8/19/2010, Slit Trenches 1-5 have been filled and are closed to future waste disposal in support of an ARRA-funded interim operational cover project. Slit Trenches 6 and 7 are currently in operation and are not addressed within this analysis. Their current inventory limits are based on the 2008 SA and are not being impacted by this study. This analysis considers the location and the timing of waste disposal in Slit Trenches 1-5 throughout their operational life. In addition, the following improvements to the modeling approach have been incorporated into this analysis: (1) Final waste inventories from WITS are used for the base case analysis where variance in the reported final disposal inventories is addressed through a sensitivity analysis; (2) Updated K{sub d} values are used; (3) Area percentages of non-crushable containers are used in the analysis to determine expected infiltration flows for cases that consider collapse of these containers; (4) An updated representation of ETF carbon column vessels disposed in SLIT3-Unit F is used. Preliminary analyses indicated a problem meeting the groundwater beta-gamma dose limit because of high H-3 and I-129 release from the ETF vessels. The updated model uses results from a recent structural analysis of the ETF vessels indicating that water does not penetrate the vessels for about 130 years and that the vessels remain structurally intact throughout the 1130-year period of assessment; and (5) Operational covers are included with revised installation dates and sets of Slit Trenches that have a common cover. With the exception of the modeling enhancements noted above, the analysis follows the same methodology used in the 2008 PA (WSRC, 2008) and the 2008 SA (Collard and Hamm, 2008). Infiltration flows through the vadose zone are identical to the flows used in the 2008 PA, except for flows during the operational cover time period. The physical (i.e., non-geochemical) models of the vadose zone and aquifer are identical in most cases to the models used in the 2008 PA. However, the 2008 PA assumed a uniform distribution of waste within each Slit Trench (WITS Location) and assumed that the entire inventory of each trench was disposed of at the time the first Slit Trench was opened. The current analysis considers individual trench excavations (i.e., segments) and groups of segments (i.e., Inventory Groups also known as WITS Units) within Slit Trenches. Waste disposal is assumed to be spatially uniform in each Inventory Group and is distributed in time increments of six months or less between the time the Inventory Group was opened and closed.

54 ENVIRONMENTAL SCIENCES↗

Unbalanced Nested Random Effects Estimation of Variance Components

To investigate the contributing factors of variance in the measurement of an iodine 127 (127I) sample, we implement a nested random effects analysis of variance (ANOVA). Historically, the reported uncertainty on a measurement of 127I has been obtained by methods of forward uncertainty propagation because there is typically only one replicate of a given sample for which to estimate the uncertainty. When samples are processed there are several types of quality control (QC) standards analyzed along-side the unknown samples with two to five replicates for each. Assuming the variance observed in these replicate QC standards is representative of that of the unknown samples, we use these data in a nested random effects ANOVA to estimate the total uncertainty of a measurement. We demonstrate this approach with two sets of measurements from Idaho National Laboratory and compare the results with the forward uncertainty propagation approach. Variance component estimates for the coarsest level of the nesting structure were most imprecise because replicates were most limited at these levels. We find that the results largely agree between forward propagation and ANOVA, and the greatest contributors of variance are due to instrument variation and chemical processing, with human processing being among the smallest contributors. This analysis provides reassurance that the reported uncertainties using forward propagation are reasonable and the process is well controlled. We propose a future designed experiment to increase replicates at the coarsest level of the hierarchy to improve estimates of these variance components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of secondary gas-phase reactions (SGR) in pyrolysis of carbon feedstocks for anisotropic carbon materials production – 2: Effects of SGR on tars produced from varying ranks of coal

Herein, this work explores the extent to which secondary gas-phase reactions (SGR) in pyrolysis can be used to modify coal tar chemistries from coals of different ranks in favor of improved anisotropy formation in their respective pitches. Pyrolysis was performed on four different coals of varying bituminous rank (Utah Sufco, Wyoming PRB Black Thunder, Illinois #6, and West Virginia Flying Eagle), with SGR temperatures ranging from 800 to 900° C and nominal SGR gas-phase residence times from 1 to 2.5 s. The oxygen content, aliphatic content, and molecular weight distributions of the coal tar samples were measured to indicate the changes with increasing levels of SGR, and microscopy was also used to measure changes in anisotropy formation in the resulting pitch samples. Generally, for all coals tested, increased levels of pyrolysis SGR led to decreased oxygen and aliphatic content, increased molecular weight sizes, and improved anisotropy formation. However, it was clear that the extent of these property changes depended on the chemistry and rank of the starting coal feedstock. Despite the relatively high rank of the Illinois #6 coal, its respective pitch samples performed poorly in improving anisotropy formation, due to its high sulfur content. The PRB, Sufco, and Flying Eagle coals performed better in their anisotropy formation than Illinois #6, depending on their respective coal ranks. Statistical analysis (analysis of variance, ANOVA) performed on the sample characterization data also suggests that SGR temperature is consistently the most dominant and significant effect on the resulting coal products.

01 COAL, LIGNITE, AND PEAT↗

Biological Sampling Variability Study

There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65.9% - dirty vs. 53.6% - clean) (see Figure 4.1). Variance component analysis was used to estimate the amount of variability for each source of variability. There wasn’t much difference in variability for dirty and clean samples, as well as between materials, so these results were pooled together. There was a significant difference in amount of concentration deposited, so results were separated for the 10 spore and 100 spore deposited tests. In each case the within sampler variability was the largest with variances of 426.2 for 10 spores and 173.1 for 100 spores. The within sampler variability constitutes the variability between the four samples of similar material, interfering material, and concentration taken by each sampler. The between sampler variance was estimated to be 0 for 10 spores and 1.2 for 100 spores. The between day variance was estimated to be 42.1 for 10 spores and 78.9 for 100 spores. Standard deviations can be calculated in each case by taking the square root of the variance.

59 BASIC BIOLOGICAL SCIENCES↗

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN↗

Comparison of Two Quantitative Methods of Discerning Airspace Enlargement in Smoke-Exposed Mice

In this work, we compare two methods for evaluating and quantifying pulmonary airspace enlargement in a mouse model of chronic cigarette smoke exposure. Standard stereological sample preparation, sectioning, and imaging of mouse lung tissues were performed for semi-automated acquisition of mean linear intercept (L m ) data. After completion of the L m measurements, D 2 , a metric of airspace enlargement, was measured in a blinded manner on the same lung images using a fully automated technique developed in-house. An analysis of variance (ANOVA) shows that although L m was able to separate the smoke-exposed and control groups with statistical significance (p = 0.034), D 2 was better able to differentiate the groups (p <0.001) and did so without any overlap between the control and smoke-exposed individual animal data. In addition, the fully automated implementation of D 2 represented a time savings of at least 24x over semi-automated L m measurements. Although D 2 does not provide 3D stereological metrics of airspace dimensions as L m does, results show that it has higher sensitivity and specificity for detecting the subtle airspace enlargement one would expect to find in mild or early stage emphysema. Therefore, D 2 may serve as a more accurate screening measure for detecting early lung disease than L m .

59 BASIC BIOLOGICAL SCIENCES↗

Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose that would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Enhanced Engineering Perspective of Global Climate Systems and Statistical Formulation of Terrestrial CO2 Exchanges

This paper designs a comprehensive approach based on the engineering machine/system concept, to model, analyze, and assess the level of CO2 exchange between the atmosphere and terrestrial ecosystems, which is an important factor in understanding changes in global climate. The focus of this article is on spatial patterns and on the correlation between levels of CO2 fluxes and a variety of influencing factors in eco-environments. The engineering/machine concept used is a system protocol that includes the sequential activities of design, test, observe, and model. This concept is applied to explicitly include various influencing factors and interactions associated with CO2 fluxes. To formulate effective models of a large and complex climate system, this article introduces a modeling technique that will be referred to as Stochastic Filtering Analysis of Variance (SFANOVA). The CO2 flux data observed from some sites of AmeriFlux are used to illustrate and validate the analysis, prediction and globalization capabilities of the proposed engineering approach and the SF-ANOVA technology. The SF-ANOVA modeling approach was compared to stepwise regression, ridge regression, and neural networks. The comparison indicated that the proposed approach is a valid and effective tool with similar accuracy and less complexity than the other procedures.

54 ENVIRONMENTAL SCIENCES↗

NDE reliability and probability of detection (POD) evolution and paradigm shift

The subject of NDE Reliability and POD has gone through multiple phases since its humble beginning in the late 1960s. This was followed by several programs including the important one nicknamed “Have Cracks – Will Travel” or in short “Have Cracks” by Lockheed Georgia Company for US Air Force during 1974–1978. This and other studies ultimately led to a series of developments in the field of reliability and POD starting from the introduction of fracture mechanics and Damaged Tolerant Design (DTD) to statistical framework by Bernes and Hovey in 1981 for POD estimation to MIL-STD HDBK 1823 (1999) and 1823A (2009). During the last decade, various groups and researchers have further studied the reliability and POD using Model Assisted POD (MAPOD), Simulation Assisted POD (SAPOD), and applying Bayesian Statistics. All and each of these developments had one objective, i.e., improving accuracy of life prediction in components that to a large extent depends on the reliability and capability of NDE methods. Therefore, it is essential to have a reliable detection and sizing of large flaws in components. Currently, POD is used for studying reliability and capability of NDE methods, though POD data offers no absolute truth regarding NDE reliability, i.e., system capability, effects of flaw morphology, and quantifying the human factors. Furthermore, reliability and POD have been reported alike in meaning but POD is not NDE reliability. POD is a subset of the reliability that consists of six phases: 1) samples selection using DOE, 2) NDE equipment setup and calibration, 3) System Measurement Evaluation (SME) including Gage Repeatability and Reproducibility (Gage R and R) and Analysis Of Variance (ANOVA), 4) NDE system capability and electronic and physical saturation, 5) acquiring and fitting data to a model, and data analysis, and 6) POD estimation. This paper provides an overview of all major POD milestones for the last several decades and discuss rationale for using Integrated Computational Materials Engineering (ICME), MAPOD, SAPOD, and Bayesian statistics for studying controllable and non-controllable variables including human factors for estimating POD. Another objective is to list gaps between “hoped for” versus validated or fielded failed hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ANOVA-HDMR structure of the higher order nodal diffusion solution

Nodal diffusion methods still represent a standard in global reactor calculations, but employ some ad-hoc approximations (such as the quadratic leakage approximation) which limit their accuracy in cases where reference quality solutions are sought. In this work we solve the nodal diffusion equations utilizing the so-called higher-order nodal methods to generate reference quality solutions and to decompose the obtained solutions via a technique known as High Dimensional Model Representation (HDMR). This representation and associated decomposition of the solution provides a new formulation of the transverse leakage term. The HDMR structure is investigated via the technique of Analysis of Variance (ANOVA), which indicates why the existing class of transversely-integrated nodal methods prove to be so successful. Furthermore, the analysis leads to a potential solution method for generating reference quality solutions at a much reduced calculational cost, by applying the ANOVA technique to the full higher order solution. (authors)

97 MATHEMATICS AND COMPUTING↗

Self-validated Variance-based Methods for Sensitivity Analysis of Model Outputs

Global sensitivity analysis (GSA) has the advantage over local sensitivity analysis in that GSA does not require strong model assumptions such as linearity or monotonicity. As a result, GSA methods such as those based on variance decomposition are well-suited to multi-physics models, which are often plagued by large nonlinearities. However, as with many other sampling-based methods, inadequate sample size can badly pollute the result accuracies. A natural remedy is to adaptively increase the sample size until sufficient accuracy is obtained. This paper proposes an iterative methodology comprising mechanisms for guiding sample size selection and self-assessing result accuracy. The elegant features in the the proposed methodology are the adaptive refinement strategies for stratified designs. We first apply this iterative methodology to the design of a self-validated first-order sensitivity analysis algorithm. We also extend this methodology to design a self-validated second-order sensitivity analysis algorithm based on refining replicated orthogonal array designs. Several numerical experiments are given to demonstrate the effectiveness of these methods.

99 GENERAL AND MISCELLANEOUS↗

Assessing Corn Stover Composition and Sources of Variability via NIRS

Corn stover, the above-ground, non-grain portion of the crop, is a large, currently available source of biomass that potentially could be collected as a biofuels feedstock. Biomass conversion process economics are directly affected by the overall biochemical conversion yield, which is assumed to be proportional to the carbohydrate content of the feedstock materials used in the process. Variability in the feedstock carbohydrate levels affects the maximum theoretical biofuels yield and may influence the optimum pretreatment or saccharification conditions. The aim of this study is to assess the extent to which commercial hybrid corn stover composition varies and begin to partition the variation among genetic, environmental, or annual influences. A rapid compositional analysis method using near-infrared spectroscopy/partial least squares multivariate modeling (NIR/PLS) was used to evaluate compositional variation among 508 commercial hybrid corn stover samples collected from 47 sites in eight Corn Belt states after the 2001, 2002, and 2003 harvests. The major components of the corn stover, reported as average (standard deviation) % dry weight, whole biomass basis, were glucan 31.9 (2.0), xylan 18.9 (1.3), solubles composite 17.9 (4.1), and lignin (corrected for protein) 13.3 (1.1). We observed wide variability in the major corn stover components. Much of the variation observed in the structural components (on a whole biomass basis) is due to the large variation found in the soluble components. Analysis of variance (ANOVA) showed that the harvest year had the strongest effect on corn stover compositional variation, followed by location and then variety. The NIR/PLS rapid analysis method used here is well suited to testing large numbers of samples, as tested in this study, and will support feedstock improvement and biofuels process research.

09 BIOMASS FUELS↗

TESTING MICROVARIABILITY IN QUASAR DIFFERENTIAL LIGHT CURVES USING SEVERAL FIELD STARS

Microvariability consists of small timescale variations of low amplitude in the photometric light curves of quasars and represents an important tool to investigate their inner core. Detection of quasar microvariations is challenging because of their non-periodicity, as well as the need for high monitoring frequency and a high signal-to-noise ratio. Statistical tests developed for the analysis of quasar differential light curves usually show either low power or low reliability, or both. In this paper we compare two statistical procedures to perform tests on several stars with enhanced power and high reliability. We perform light curve simulations of variable quasars and non-variable stars and analyze them with statistical procedures developed from the F-test and the analysis of variance. The results show a large improvement in the power of both statistical probes and a larger reliability when several stars are included in the analysis. The results from the simulations agree with those obtained from observations of real quasars. The high power and high reliability of the tests discussed in this paper improve the results that can be obtained from short and long timescale variability studies. These techniques are not limited to quasar variability; on the contrary, they can be easily implemented for other sources, such as variable stars. Their applications to future research and to the analysis of large-field photometric monitoring archives could reveal new variable sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing Wildland Fire Smoke Emissions Data Using Compositional Data Techniques

By conservation of mass, the mass of wildland fuel that is pyrolyzed and combusted must equal the mass of smoke emissions, residual char and ash. For a given set of conditions, these amounts are fixed. This places a constraint on smoke emissions data which violates statistical assumptions for many of the methods currently used to analyze these data such as linear regression, analysis of variance, and t-tests. These data are inherently multivariate and non-negative parts of a whole. This paper introduces the field of compositional data analysis to the emissions community and provides examples of appropriate statistical treatment of emissions data. It is shown that modified combustion efficiency should not be used as a predictor variable for other smoke emissions because it is not an independent variable. An alternative method based on compositional linear trends to estimate trace gas composition using CO and CO2 is presented. The data used in this paper resulted from projects the DOD/DOE/EPA Strategic 586 Environmental Research and Development Program projects RC-1648 and 1649. The senior 587 author appreciates the guidance and R scripts provided by Prof. Girty at San Diego State 588 University to estimate linear trends by perturbation. J. P.-A. was supported by the Spanish 589 Ministry of Science, Innovation and Universities under the project CODAMET (RTI2018-590 095518-B-C21, 2019-2021). The data used in this study have been previously published and are 591 available in the original publications. DRW conceived the initial manuscript (70 percent) and 592 performed the bulk of the data analysis. JPA provided statistical guidance and compositional data 593 expertise and contributed 20 percent of the manuscript. TJJ and HJ were extensively involved in 594 the study that provided the data. TJJ provide smoke emissions expertise and HJ provided 595 combustion expertise. The authors declare that they have no conflict of interest. The use of trade 596 or firm names in this publication is for reader information and does not imply endorsement by 597 the U.S. Department of Agriculture of any product or service.

simplex, compositional data analysis, balance, log↗

Comparison of Error Rate Depending on Operator Expertise and Simulator Complexity

This paper analyzes operator's error rate from experiments, depending on the expertise and simulator complexity. This study uses the Rancor Microworld, a simplified simulator developed by INL, and the Compact Nuclear Simulator (CNS), a less simplified simulator developed by the Korea Atomic Energy Research Institute (KAERI). The error rates were measured from simulation data of a total of 72 participants, and the collected error rate data were analyzed using analysis of variance (ANOVA) test.

99 GENERAL AND MISCELLANEOUS↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗