Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of an x-ray prism for analyzer based imaging systems

Analyzer crystal based imaging techniques such as diffraction enhanced imaging (DEI) and multiple imaging radiography (MIR) utilize the Bragg peak of perfect crystal diffraction to convert angular changes into intensity changes. These x-ray techniques extend the capability of conventional radiography, which derives image contrast from absorption, by providing large intensity changes for small angle changes introduced from the x-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultrasmall angle x-ray scattering contrast improving visualization and extending the utility of x-ray imaging. To improve on the current DEI technique an x-ray prism (XRP) was designed and included in the imaging system. The XRP allows the analyzer crystal to be aligned anywhere on the rocking curve without physically moving the analyzer from the Bragg angle. By using the XRP to set the rocking curve alignment rather than moving the analyzer crystal physically the needed angle sensitivity is changed from submicroradians for direct mechanical movement of the analyzer crystal to tens of milliradians for movement of the XRP angle. However, this improvement in angle positioning comes at the cost of absorption loss in the XRP and depends on the x-ray energy. In addition to using an XRP for crystal alignment it has the potential for scanning quickly through the entire rocking curve. This has the benefit of collecting all the required data for image reconstruction in a single measurement thereby removing some problems with motion artifacts which remain a concern in current DEI/MIR systems especially for living animals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering

Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L 3 -edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L 3 -absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axially Symmetric Energy Analyzer Based on the Electrostatic Decapole-Cylindrical Field

A new electron-optical scheme of an axially symmetric mirror energy analyzer based on the electrostatic decapole-cylindrical field is presented. A trajectory analysis of electron motion is performed. Design features of the proposed energy analyzer scheme are described. Second-order focusing regimes for two configurations are numerically calculated: (1) a ring source and its image located in the region of the inner cylinder and (2) a point source located at a great distance from the energy analyzer on the symmetry axis. It is shown that on the basis of the decapole-cylindrical field, a long-focal-length mirror energy analyzer with “axis–ring” type focusing can be built. Instrumental functions for two regimes of the energy analyzer are given; energy resolution and luminosity of the device are estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements

Abstract. Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.

54 ENVIRONMENTAL SCIENCES↗

NO sub X destruction by CO in NO sub X to NO converters of chemiluminescent NO analyzers

An instrument modification for chemiluminescent NO - NOx analyzers was developed which minimizes the NOx destruction in the NOx to NO converters of NO analyzers due to high concentrations of CO. This mechanism causes the NO analyzers to indicate incorrect NOx concentrations when the analyzers are operated in the NOx analysis mode. The modification is applicable to analyzers in which the detection chamber is evacuated.

Summers, R. L.↗

Directional velocity analyzer for measuring electron distribution functions in plasmas

A directional velocity analyzer has been developed for measuring electron distribution functions in plasmas. It contains a collimating aperture which selects particles from a narrow cone in velocity space and a retarding potential analyzer. The distribution function f(v, theta, phi) is obtained from a large number of analyzer traces taken at different angles theta, phi. In addition, the small analyzer can be moved in space and the measurements are time resolved so as to obtain the complete phase space information f(v,r,t). The large data flow of this seven-variable function is processed with a high-speed digital data-acquisition system. The new electron velocity analyzer is applicable over a wide parameter range in electron energies and densities. Various cases of anisotropic distributions such as beams, shells, tails, and drifts have been successfully investigated.

Stenzel, R. L.↗

Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and field evaluations a single vendor was recommended for use by NASA/IJSA Safety personnel. Vendor selection criteria, as well as the results from both laboratory and field testing of the multi-gas analyzers, are presented as part of this paper.

Lueck, D. E.↗

On Variable Geometric Factor Systems for Top-Hat Electrostatic Space Plasma Analyzers

Even in the relatively small region of space that is the Earth's magnetosphere, ion and electron fluxes can vary by several orders of magnitude. Top-hat electrostatic analyzers currently do not possess the dynamic range required to sample plasma under all conditions. The purpose of this study was to compare, through computer simulation, three new electrostatic methods that would allow the sensitivity of a sensor to be varied through control of its geometric factor (GF) (much like an aperture on a camera). The methods studied were inner filter plates, split hemispherical analyzer (SHA) and top-cap electrode. This is the first discussion of the filter plate concept and also the first study where all three systems are studied within a common analyzer design, so that their relative merits could be fairly compared. Filter plates were found to have the important advantage that they facilitate the reduction in instrument sensitivity whilst keeping all other instrument parameters constant. However, it was discovered that filter plates have numerous disadvantages that make such a system impracticable for a top-hat electrostatic analyzer. It was found that both the top-cap electrode and SHA are promising variable geometric factor system (VGFS) concepts for implementation into a top-hat electrostatic analyzer, each with distinct advantages over the other.

Kataria, Dhiren O.↗

Bumper: A Tool for Analyzing Spacecraft Micrometeoroid and Orbital Debris Risk

“Bumper” is NASA’s computer program for analyzing spacecraft micrometeoroid and orbital debris (MMOD) risk. Bumper was developed in the late-1980s and has been continuously used and maintained since. The user base has grown from a few government entities to now include numerous commercial entities as well. The NASA Johnson Space Center (JSC) Hypervelocity Impact Technology (HVIT) Team is responsible for all aspects of the Bumper software. Bumper has been used to characterize MMOD risk on hundreds of spacecraft. All of the International Space Station (ISS) modules, visiting vehicles and numerous external components and systems have been analyzed. Bumper was used to analyze each of the Space Shuttle missions since STS-50. The Orion Multi-Purpose Crew Vehicle (MPCV) MMOD shielding is being developed using Bumper as well. Bumper has also been used on numerous telescopes (Hubble, James Webb, and Fermi Gamma-ray Space Telescopes), scientific probes (Stardust, New Horizons, Parker Solar Probe), and Earth observation satellites (Landsat, Joint Polar Satellite System). Bumper is also being used to analyze the micrometeoroid risk and support design of the Deep Space Gateway (DSG) and Mars Sample Return (MSR) missions. The HVIT Bumper Configuration Control Board (CCB) ensures that all changes to the code are approved, reviewed, and documented. Most of the changes are made to add new MMOD damage “ballistic limit equations” (BLEs). BLEs are typically added in response to completion of a hypervelocity impact (HVI) test series and development of an associated BLE. Other less frequent changes include updates of the debris or meteoroid environment models, feature enhancements, and feature retirement. Some BLEs are commercially sensitive and/or proprietary, so the CCB also manages code user-version control and software distribution. The current version – “Bumper 3” – is a FORTRAN executable that utilizes a 64-bit architecture. Bumper 3 has numerous features that make it a powerful tool for analyzing spacecraft MMOD risk. Bumper uses the latest orbital debris and micrometeoroid environment models. Bumper also easily processes large spacecraft geometry models, recognizes hidden surfaces, permits BLE assignment by name or number, and conducts quality checks of the spacecraft geometry model. Bumper 3 can also be used to estimate the effects of particle penetration through thin, high-standoff distance hardware components such as solar arrays and radiators. This is done using a special HVIT-developed technique know as the “3-Part Analysis.” The paper introduces the Bumper 3 MMOD risk analysis code and provides an example MMOD risk assessment showing Bumper’s role in the overall MMOD protection design process.

Lear, Dana M.↗

BUMPER: A Tool for Analyzing Spacecraft Micrometeoroid and Orbital Debris Risk

“Bumper” is a computer program for analyzing spacecraft micrometeoroid and orbital debris (MMOD) risk. Bumper was developed in the late-1980s and has been continuously maintained and used since. The user base has grown from a few government entities now include numerous commercial entities as well. The National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) Hypervelocity Impact Technology (HVIT) group is responsible for all aspects of the Bumper software. Bumper has been used to characterize MMOD risk on many spacecraft. All of the International Space Station (ISS) modules, visiting vehicles and numerous external components and systems have been analyzed. Bumper was used to analyze the Space Shuttle, Orion, and many space probes, telescopes and satellites. Bumper is also being used to analyze future spacecraft such as the Deep Space Gateway (DSG) and Mars Sample Return (MSR) missions. The Bumper Configuration Control Board (CCB) ensures that all changes to the code are approved, reviewed, and documented. The current Bumper version – “Bumper 3” – is a Fortran executable that utilizes a 64-bit architecture. Bumper has numerous features that make it a powerful tool for analyzing spacecraft MMOD risk. Bumper uses the latest orbital debris and meteoroidenvironment models. Bumper also has a large library of ballistic limit “damage” equations available that can be used for a wide variety of MMOD shielding configurations. Bumper can also handle large spacecraft finite elementmodels (FEMs) and conducts checks of the model. This paper introduces Bumper and the MMOD risk analysis process using a simplified cube-shaped spacecraft model

hypervelocity↗

Monte–Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor

A modern cold triple-axis spectrometer to study quantum condensed matter systems is planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the conceptual principles and design of a secondary spectrometer using a multiplexed, prismatic analyzer system relying on graphite crystals and inspired by the successful implementation of the Continuous Angle Multiple Energy Analysis (CAMEA) spectrometers at the Paul Scherrer Institute. This project is currently known as MANTA for Multi-Analyzer Neutron Triple-Axis. Here, we report Monte-Carlo ray-tracing simulations on a simple but realistic sample scattering kernel to further illustrate the prismatic analyzer concept’s workings, calibration, and performance. Then, we introduce a new statistical analysis approach based on the prismatic analyzer concept to improve the number of final energies measured on the spectrometer. We also study possible evolutions in the CAMEA design relevant for MANTA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship between dislocations and residual stresses in cold-drawn pearlitic steel analyzed by energy-dispersive X-ray diffraction

We analyzed the dislocation distribution of cold-drawn pearlitic-steel wire by using the line-profile analysis based on the energy dispersive X-ray diffraction (EDXD). Although this line-profile analysis requires a high resolution in reciprocal space, the resolution for EDXD is generally poor due to the energy resolution of the detector. Our analysis demonstrated that the resolution in the reciprocal space can be maximized at small scattering angles. Using the line-profile analysis based on the EDXD, the microstructural parameters such as the crystallite size and the dislocation density of the ferrite phase in the pearlitic steel were successfully analyzed. In addition, the distribution of the residual stress of the ferrite phase of a pearlitic steel wire was also analyzed using the EDXD measurement. - Highlights: • Energy dispersive X-ray diffraction is applied to the line-profile analysis. • Distribution of dislocations in ferrite in the pearlitic steel wire is analyzed. • Relationship between dislocations and residual stress is discussed.

36 MATERIALS SCIENCE↗

OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

Mass spectrometry imaging (MSI) has primarily been applied in localizing biomolecules within biological matrices. Although well-suited, the application of MSI for comparing thousands of spatially defined spotted samples has been limited. One reason for this is a lack of suitable and accessible data processing tools for the analysis of large arrayed MSI sample sets. In this paper, the OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http://openmsi.nersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was evaluated by analyzing an MSI data set of a high-throughput glycoside hydrolase activity screen comprising 384 samples arrayed onto a NIMS surface at a 450 μm spacing, decreasing analysis time >100-fold while maintaining robust spot-finding. The utility of OMAAT was demonstrated for screening metabolic activities of different sized soil particles, including hydrolysis of sugars, revealing a pattern of size dependent activities. Finally, these results introduce OMAAT as an effective toolkit for analyzing spatially defined samples in MSI. OMAAT runs on all major operating systems, and the source code can be obtained from the following GitHub repository: https://github.com/biorack/omaat.

47 OTHER INSTRUMENTATION↗

Modeling the Enceladus dust plume based on in situ measurements performed with the Cassini Cosmic Dust Analyzer

We analyzed data recorded by the Cosmic Dust Analyzer on board the Cassini spacecraft during Enceladus dust plume traversals. Our focus was on profiles of relative abundances of grains of different compositional types derived from mass spectra recorded with the Dust Analyzer subsystem during the Cassini flybys E5 and E17. The E5 profile, corresponding to a steep and fast traversal of the plume, has already been analyzed. In this paper, we included a second profile from the E17 flyby involving a nearly horizontal traversal of the south polar terrain at a significantly lower velocity. Additionally, we incorporated dust detection rates from the High Rate Detector subsystem during flybys E7 and E21. We derived grain size ranges in the different observational data sets and used these data to constrain parameters for a new dust plume model. This model was constructed using a mathematical description of dust ejection implemented in the software package DUDI. Further constraints included published velocities of gas ejection, positions of gas and dust jets, and the mass production rate of the plume. Our model employs two different types of sources: diffuse sources of dust ejected with a lower velocity and jets with a faster and more colimated emission. From our model, we derived dust mass production rates for different compositional grain types, amounting to at least 28 kg s –1 . Previously, salt-rich dust was believed to dominate the plume mass based on E5 data alone. The E17 profile shows a dominance of organic-enriched grains over the south polar terrain, a region not well constrained by E5 data. By including both E5 and E17 profiles, we find the salt-rich dust contribution to be at most 1% by mass. This revision also results from an improved understanding of grain masses of various compositional types that implies smaller sizes for salt-rich grains. Our new model can predict grain numbers and masses for future mission detectors during plume traversals.

79 ASTRONOMY AND ASTROPHYSICS↗

2-D energy analyzer for low energy electrons

A 2-D electron energy analyzer is designed and constructed to measure the transverse and longitudinal energy distribution of low energy (<1 eV) electrons. The analyzer operates on the principle of adiabatic invariance and motion of low energy electrons in a strong longitudinal magnetic field. The operation of the analyzer is studied in detail and a design to optimize the energy resolution, signal to noise ratio, and physical size is presented. An energy resolution better than 6 meV has been demonstrated. Such an analyzer is a powerful tool to study the process of photoemission which limits the beam quality in modern accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetized retarding field energy analyzer measuring the particle flux and ion energy distribution of both positive and negative ions

This paper presents the development of a magnetized retarding field energy analyzer (MRFEA) used for positive and negative ion analysis. The two-stage analyzer combines a magnetic electron barrier and an electrostatic ion energy barrier allowing both positive and negative ions to be analyzed without the influence of electrons (co-extracted or created downstream). An optimal design of the MRFEA for ion-ion beams has been achieved by a comparative study of three different MRFEA configurations, and from this, scaling laws of an optimal magnetic field strength and topology have been deduced. The optimal design consists of a uniform magnetic field barrier created in a rectangular channel and an electrostatic barrier consisting of a single grid and a collector placed behind the magnetic field. The magnetic barrier alone provides an electron suppression ratio inside the analyzer of up to 6000, while keeping the ion energy resolution below 5 eV. The effective ion transparency combining the magnetic and electrostatic sections of the MRFEA is measured as a function of the ion energy. It is found that the ion transparency of the magnetic barrier increases almost linearly with increasing ion energy in the low-energy range (below 200 eV) and saturates at high ion energies. The ion transparency of the electrostatic section is almost constant and close to the optical transparency of the entrance grid. We show here that the MRFEA can provide both accurate ion flux and ion energy distribution measurements in various experimental setups with ion beams or plasmas run at low pressure and with ion energies above 10 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End loss analyzer system for measurements of plasma flux at the C-2U divertor electrode

An end loss analyzer system consisting of electrostatic, gridded retarding-potential analyzers and pyroelectric crystal bolometers was developed to characterize the plasma loss along open field lines to the divertors of C-2U. The system measures the current and energy distribution of escaping ions as well as the total power flux to enable calculation of the energy lost per escaping electron/ion pair. Special care was taken in the construction of the analyzer elements so that they can be directly mounted to the divertor electrode. An attenuation plate at the entrance to the gridded retarding-potential analyzer reduces plasma density by a factor of 60 to prevent space charge limitations inside the device, without sacrificing its angular acceptance of ions. In addition, all of the electronics for the measurement are isolated from ground so that they can float to the bias potential of the electrode, 2 kV below ground.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗