Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantifying the passive gamma signal from spent nuclear fuel in support of determining the plutonium content in spent nuclear fuel with nondestructive assay

The objective of safeguarding nuclear material is to deter diversions of significant quantities of nuclear materials by timely monitoring and detection. There are a variety of motivations for quantifying plutonium in spent fuel (SF), by means of nondestructive assay (NDA), in order to meet this goal. These motivations include the following: strengthening the capabilities of the International Atomic Energy Agencies ability to safeguard nuclear facilities, shipper/receiver difference, input accountability at reprocessing facilities and burnup credit at repositories. Many NDA techniques exist for measuring signatures from SF; however, no single NDA technique can, in isolation, quantify elemental plutonium in SF. A study has been undertaken to determine the best integrated combination of 13 NDA techniques for characterizing Pu mass in spent fuel. This paper focuses on the development of a passive gamma measurement system in support the spent fuel assay system. Gamma ray detection for fresh nuclear fuel focuses on gamma ray emissions that directly coincide with the actinides of interest to the assay. For example, the 186-keV gamma ray is generally used for {sup 235}U assay and the 384-keV complex is generally used for assaying plutonium. In spent nuclear fuel, these signatures cannot be detected as the Compton continuum created from the fission products dominates the signal in this energy range. For SF, the measured gamma signatures from key fission products ({sup 134}Cs, {sup 137}Cs, {sup 154}Eu) are used to ascertain burnup, cooling time, and fissile content information. In this paper the Monte Carlo modeling set-up for a passive gamma spent fuel assay system will be described. The set-up of the system includes a germanium detector and an ion chamber and will be used to gain passive gamma information that will be integrated into a system for determining Pu in SF. The passive gamma signal will be determined from a library of {approx} 100 assemblies that have been created to examine the capability of all 13 NDA techniques. Presented in this paper is a description of the passive gamma monitoring instrument, explanation of the work completed thus far involving the source set up methodology and the design optimization process, details of key fission product ratios of interest, limitations and key strengths of the measurement technique, and considerations for integrating this technique with other NDA techniques in order to develop a complete spent fuel assay strategy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Impact of Gate Width Setting and Gate Utilization Factors on Plutonium Assay in Passive Correlated Neutron Counting

In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predictive Capabilities of in Vitro Assays for Estimating Pb Relative Bioavailability in Phosphate Amended Soils

In this study, the in vitro bioaccessibility (IVBA) of lead (Pb) in phosphate-amended Pb-contaminated soil was assessed using a variety of IVBA assays with an overarching aim of determining whether changes in Pb IVBA were congruent to those observed for Pb relative bioavailability (RBA) determined using an in vivo mouse assay. Here, amending soil with phosphoric acid or rock phosphate resulted in changes in Pb speciation, however, varying Pb IVBA results were obtained depending on the methodology utilized. In addition, IVBA assays influenced Pb speciation as a consequence of interactions between dissolved Pb and unreacted phosphate arising from the amendment or from assay constituents. When the relationship between Pb RBA and IVBA was assessed, a comparison of treatment effect ratios (Pb RBA or IVBA in treated soil divided by Pb RBA or IVBA for untreated soil) provided the best in vivo–in vitro correlation particular for SBRC (r 2 = 0.83) and IVG (r 2 = 0.89) intestinal extraction. For these assays, the slope of the lines of best fit were close to 1 (1.12, 0.82; SBRC, IVG intestinal extraction respectively) with small y-intercepts (0.09, 0.08 respectively) indicating that the efficacy of phosphate amendments for reducing Pb RBA may be predicted using IVBA assays.

54 ENVIRONMENTAL SCIENCES↗

Highly Sensitive and Selective Immuno-capture/Electrochemical Assay of Acetylcholinesterase Activity in Red Blood Cells: A Biomarker of Exposure to Organophosphorus Pesticides and Nerve Agents

Acetylcholinesterase (AChE) enzyme activity in red blood cells (RBCs) is a useful biomarker for biomonitoring of exposures to organophosphorus (OP) pesticides and chemical nerve agents. In this paper, we reported a new method for AChE activity assay based on selective immuno-capture of AChE from biological samples followed by enzyme activity assay of captured AChE using a disposable electrochemical sensor. The electrochemical sensor is based on multiwalled carbon nanotubes-gold nanocomposites (MWCNTs-Au) modified screen printed carbon electrode (SPCE). Upon the completion of immunoreaction, the target AChE (including active and inhibited) is captured onto the electrode surface and followed by an electrochemical detection of enzymatic activity in the presence of acetylthiocholine. A linear response is obtained over standard AChE concentration range from 0.1 to 10 nM. To demonstrate the capability of this new biomonitoring method, AChE solutions dosed with different concentration of paraoxon were used to validate the new AChE assay method. AChE inhibition in OP dosed solutions was proportional to its concentration from 0.2 to 50 nM. The new AChE activity assay method for biomonitoring of OP exposure was further validated with in-vitro paraoxon-dosed RBC samples. The established electrochemical sensing platform for AChE activity assay not only avoids the problem of overlapping substrate specificity with esterases by using selective antibody, but also eliminates potential interference from other electroactive species in biological samples. It offers a new approach for sensitive, selective, and rapid AChE activity assay for biomonitoring of exposures to OPs.

59 BASIC BIOLOGICAL SCIENCES↗

Further Evaluation of the Neutron Resonance Transmission Analysis (NRTA) Technique for Assaying Plutonium in Spent Fuel

This is an end-of-year report (Fiscal Year (FY) 2011) for the second year of effort on a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The second-year goals for this project included: (1) assessing the neutron source strength needed for the NRTA technique, (2) estimating count times, (3) assessing the effect of temperature on the transmitted signal, (4) estimating plutonium content in a spent fuel assembly, (5) providing a preliminary assessment of the neutron detectors, and (6) documenting this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes work performed over a nine month period from January-September 2011 and is to be considered a follow-on or add-on report to our previous published summary report from December 2010 (INL/EXT-10-20620).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Martian Superoxide and Peroxide O2 Release (OR) Assay: A New Technology for Terrestrial and Planetary Applications

This study presents an assay for the detection and quantification of soil metal superoxides and peroxides in regolith and soil. The O2 release (OR) assay is based on the enzymatic conversion of the hydrolysis products of metal oxides to O2, and their quantification by an O2 electrode based on the stoichiometry of the involved reactions: The intermediate product O2 from the hydrolysis of metal superoxides is converted by cytochrome c to O2, and also by superoxide dismutase (SOD) to 1/2 mol O2 and 1/2 mol H2O2, which is then converted by catalase (CAT) to 1/2 mol O2. The product H2O2 from the hydrolysis of metal peroxides and hydroperoxides is converted to 1/2 mol O2 by CAT. The assay-method was validated in a sealed sample chamber using a liquid-phase Clark-type O2 electrode with known concentrations of O2 and H2O2, and with commercial metal superoxide and peroxide mixed with Mars analogue Mojave and Atacama Desert soils. Carbonates and perchlorates, both present on Mars, do not interfere with the assay. The assay lower limit of detection, using luminescence quenching/optical sensing O2-electrodes, is 1 nmol O2 cm(exp. -3) or better. The activity of the assay enzymes SOD and cytochrome c was unaffected up to 6 Gy exposure by gamma-radiation, while CAT retained 100% and 40% of its activity at 3 and 6 Gy, respectively, demonstrating the suitability of these enzymes for planetary missions, e.g., in Mars or Europa.

soil metal superoxides and peroxides↗

Experiment Isotopic Data Compiled by the OECD/NEA Expert Group on Assay Data for Spent Nuclear Fuel

An essential component of computational modeling and simulation is the availability of well-qualified experimental benchmark data against which calculation systems can be validated and the bias and uncertainty associated with the codes and data can be evaluated. The validation process is extremely important for safety and licensing to demonstrate that adequate margins for uncertainty have been included in the calculations. For safety evaluations involving spent nuclear fuel, the isotopic compositions and resulting activities calculated using depletion and decay codes must be validated against experimental determinations of the spent fuel content. In this process the isotopic concentrations predicted by the codes should be compared with corresponding measurements of spent fuel made by destructive analysis as a fundamental part of any code performance evaluation. In recent years there has been growing international interest in acquiring high-quality assay data that can be used to validate code calculations, particularly for modern fuel designs and high burnup fuels and for a wider range of nuclides important to nuclear criticality safety, radiological safety assessments, and decay heat. Assay data are required to validate a broad range of reactor and fuel-cycle applications, including reactor core simulation, postulated severe accident analysis, spent fuel handling, spent fuel transportation and interim storage, reprocessing, nuclear safeguards, and final fuel repository evaluations. In some cases researchers working on depletion code development have noted a general lack of available assay measurements that can be used to benchmark and validate their code calculations for spent fuel compositions. This perception is due in part to the fact that data have been reported in diverse publications over many years, many experimental reports are difficult to access, and there has not been a concerted and funded effort to compile and consolidate available measurements that can be easily accessed by code developers and analysts for validation. In response to the increased interest in fuel isotopic measurements and needs for consolidation and documentation of available data, an Expert Group on Assay Data for Spent Nuclear Fuel (EGADSNF) was formed in 2007 as a working group of the Organisation for Economic Cooperation and Development (OECD)/Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS). Although the group was formed by the Expert Group on Burnup Credit to coordinate isotopic assay data activities and facilitate collaboration between countries developing or implementing burnup credit in their nuclear criticality safety methodologies, the group recognized the need and value of assay data for a broad range of spent fuel applications, and the EGADSNF includes members representing not only the WPNCS, but also members from the standing technical Committee on the Safety of Nuclear Installations and the Integration Group for the Safety Case of the Radioactive Waste Management Committee. Member countries currently active in the EGADSNF include Belgium, the Czech Republic, France, Germany, Japan, Slovakia, Spain, Sweden, the United Kingdom, and the United States. The experimental database of spent fuel measurements maintained by the OECD/NEA is web-accessible. SFCOMPO (database of Spent Fuel Compositions) contains measured isotopic data, mostly for light water reactor (LWR) fuels, for about 250 fuel samples. This paper summarizes the status of SFCOMPO and current activities to expand and improve the database.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress and Goals for INMM ASC N15 Consensus Standard "Administrative Practices for the Determination and Reporting of Results of Non-Destructive Assay Measurements of Nuclear Material in Situ for Safeguards Nuclear Criticality Safety and Other Purposes"

This paper will discuss the goals and progress to date on the development of INMM Accredited Standard Committee (ASC) N15 consensus standard Administrative Practices for the Determination and Reporting of Results of Non-Destructive Assay Measurements of Nuclear Material in situ for Safeguards, Nuclear Criticality Safety, and Other Purposes. This standard will define administrative practices in the areas of data generation and reporting of NDA assay of holdup deposits with consideration of the stakeholders of the reported results. These stakeholders may include nuclear material accounting and safeguards, nuclear criticality safety, waste management, health physics, facility characterization, authorization basis, radiation safety, and site licensing authorities. Stakeholder input will be solicited from interested parties and incorporated during the development of the document. Currently only one consensus standard exists that explicitly deals with NDA holdup measurements: ASTM C1455 Standard Test Method for Nondestructive Assay of Special Nuclear Material Holdup Using Gamma-Ray Spectroscopic Methods. The ASTM International standard emphasizes the activities involved in actually making measurements and was developed by safeguards and NDA experts. This new INMM ASC N15 standard will complement the existing ASTM international standard. One of the largest driving factors for writing this new standard was the recent emphasis on in situ NDA measurements by the safeguards community due to the Defense Nuclear Facility Safety Board (DNFSB) recommendation 2007-1 on in situ NDA measurements. Specifically, DNFSB recommendation 2007-1 referenced the lack of programmatic requirements for accurate in situ measurements and the use of measurement results for compliance with safety-based requirements. That being the case, this paper will also discuss the progress made on the Implementation Plan for Defense Nuclear Facilities Safety Board Recommendation 2007-1 Safety-Related In Situ Nondestructive Assay of Radioactive Materials. Some of the information that will be presented includes observations made during site visits, how information useful to all facilities using nondestructive assay to determine holdup material quantities will be disseminated, and preliminary results of a gap analysis performed on current in situ nondestructive assay holdup measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.

Orrell, John L.↗

Discovery of novel poly(ADP-ribose) glycohydrolase inhibitors by a quantitative assay system using dot-blot with anti-poly(ADP-ribose)

Poly(ADP-ribosyl)ation, which is mainly regulated by poly(ADP-ribose) polymerase (PARP) and poly(ADP-ribose) glycohydrolase (PARG), is a unique protein modification involved in cellular responses such as DNA repair and replication. PARG hydrolyzes glycosidic linkages of poly(ADP-ribose) synthesized by PARP and liberates ADP-ribose residues. Recent studies have suggested that inhibitors of PARG are able to be potent anti-cancer drug. In order to discover the potent and specific Inhibitors of PARG, a quantitative and high-throughput screening assay system is required. However, previous PARG assay systems are not appropriate for high-throughput screening because PARG activity is measured by radioactivities of ADP-ribose residues released from radioisotope (RI)-labeled poly(ADP-ribose). In this study, we developed a non-RI and quantitative assay system for PARG activity based on dot-blot assay using anti-poly(ADP-ribose) and nitrocellulose membrane. By our method, the maximum velocity (V{sub max}) and the michaelis constant (k{sub m}) of PARG reaction were 4.46 {mu}M and 128.33 {mu}mol/min/mg, respectively. Furthermore, the IC50 of adenosine diphosphate (hydroxymethyl) pyrrolidinediol (ADP-HPD), known as a non-competitive PARG inhibitor, was 0.66 {mu}M. These kinetics values were similar to those obtained by traditional PARG assays. By using our assay system, we discovered two novel PARG inhibitors that have xanthene scaffold. Thus, our quantitative and convenient method is useful for a high-throughput screening of PARG specific inhibitors.

60 APPLIED LIFE SCIENCES↗

Newly developed selective immunoinactivation assay revealed reduction in adipose triglyceride lipase activity in peripheral leucocytes from patients with idiopathic triglyceride deposit cardiomyovasculopathy

Highlights: • Development of selective immunoinactivation assay for ATGL activity in leucocytes. • ATGL activity was markedly reduced in idiopathic TGCV without ATGL mutations. • ATGL in leucocytes may be an important biomarker for the diagnosis of TGCV. • Selective immunoinactivation assay provides insights into pathogenesis for TGCV. Triglyceride deposit cardiomyovasculopathy (TGCV) is a rare and newly identified disease among patients requiring cardiac transplantation. TGCV is characterized by cardiomyocyte steatosis and triglyceride (TG)-deposit atherosclerosis, resulting from the abnormal intracellular metabolism of TG. TGCV is classified into primary and idiopathic types. Primary TGCV carries ultra-rare genetic mutations in the adipose triglyceride lipase (ATGL), a rate-liming enzyme that hydrolyzes intracellular TG in adipose and non-adipose tissues. Idiopathic TGCV, first identified among autopsied individuals with diabetes mellitus (DM) with severe heart diseases, shows no ATGL mutations and its causes and underlying mechanisms are still unknown. TGCV is difficult to diagnose in daily clinics, thereby demanding feasible diagnostic procedures. We aimed to develop an assay to measure ATGL activity using peripheral leucocytes. Human his6-ATGL was expressed in COS1 cells, purified to homogeneity, and used to raise a polyclonal antibody neutralizing TG-hydrolyzing activity of ATGL. We developed a selective immunoinactivation assay (SIIA) for the quantitation of ATGL activity in cell lysates of leucocytes by the antibody neutralizing ATGL activities. ATGL activity was measured in 13 idiopathic TGCV patients, with two patients with primary TGCV as the negative control. Healthy (non-DM) and DM controls without heart diseases were also subjected. The developed SIIA assay revealed significant reduction in ATGL activity in leucocytes from patients with idiopathic TGCV who did not carry ATGL mutations as compared with non-DM and DM controls. Thus, ATGL in leucocytes may be an important biomarker for the diagnosis of TGCV and our assay may provide insights into pathophysiology and elucidate the underlying mechanism of TGCV and related disorders.

60 APPLIED LIFE SCIENCES↗

Progress on the development of human in vitro dendritic cell based assays for assessment of the sensitizing potential of a compound

Allergic contact dermatitis is the result of an adaptive immune response of the skin to direct exposure to an allergen. Since many chemicals are also allergens, European regulations require strict screening of all ingredients in consumer products. Until recently, identifying a potential allergen has completely relied on animal testing (e.g.: Local Lymph Node Assay). In addition to the ethical problems, both the 7th Amendment to the Cosmetics Directive and REACH have stimulated the development of alternative tests for the assessment of potential sensitizers. This review is aimed at summarising the progress on cell based assays, in particular dendritic cell based assays, being developed as animal alternatives. Primary cells (CD34{sup +} derived dendritic cells, monocyte derived dendritic cells) as well as dendritic cell-like cell lines (THP-1, U-937, MUTZ-3, KG-1, HL-60, and K562) are extensively described along with biomarkers such as cell surface markers, cytokines, chemokines and kinases. From this review, it can be concluded that no single cell based assay nor single marker is yet able to distinguish all sensitizers from non-sensitizers in a test panel of chemicals, nor is it possible to rank the sensitizing potential of the test chemicals. This suggests that sensitivity and specificity may be increased by a tiered assay approach. Only a limited number of genomic and proteomic studies have been completed until now. Such studies have the potential to identify novel biomarkers for inclusion in future assay development. Although progress is promising, this review suggests that it may be difficult to meet the up and coming European regulatory deadlines.

60 APPLIED LIFE SCIENCES↗

Analysis of JC virus DNA replication using a quantitative and high-throughput assay

Progressive Multifocal Leukoencephalopathy (PML) is caused by lytic replication of JC virus (JCV) in specific cells of the central nervous system. Like other polyomaviruses, JCV encodes a large T-antigen helicase needed for replication of the viral DNA. Here, we report the development of a luciferase-based, quantitative and high-throughput assay of JCV DNA replication in C33A cells, which, unlike the glial cell lines Hs 683 and U87, accumulate high levels of nuclear T-ag needed for robust replication. Using this assay, we investigated the requirement for different domains of T-ag, and for specific sequences within and flanking the viral origin, in JCV DNA replication. Beyond providing validation of the assay, these studies revealed an important stimulatory role of the transcription factor NF1 in JCV DNA replication. Finally, we show that the assay can be used for inhibitor testing, highlighting its value for the identification of antiviral drugs targeting JCV DNA replication. - Highlights: • Development of a high-throughput screening assay for JCV DNA replication using C33A cells. • Evidence that T-ag fails to accumulate in the nuclei of established glioma cell lines. • Evidence that NF-1 directly promotes JCV DNA replication in C33A cells. • Proof-of-concept that the HTS assay can be used to identify pharmacological inhibitor of JCV DNA replication.

60 APPLIED LIFE SCIENCES↗

A high throughput Cre–lox activated viral membrane fusion assay identifies pharmacological inhibitors of HIV entry

Enveloped virus entry occurs when viral and cellular membranes fuse releasing particle contents into the target cell. Human immunodeficiency virus (HIV) entry occurs by cell-free virus or virus transferred between infected and uninfected cells through structures called virological synapses. We developed a high-throughput cell-based assay to identify small molecule inhibitors of cell-free or virological synapse-mediated entry. An HIV clone carrying Cre recombinase as a Gag-internal gene fusion releases active Cre into cells upon viral entry activating a recombinatorial gene switch changing dsRed to GFP-expression. A screen of a 1998 known-biological profile small molecule library identified pharmacological HIV entry inhibitors that block both cell-free and cell-to-cell infection. Many top hits were noted as HIV inhibitors in prior studies, but not previously recognized as entry antagonists. Modest therapeutic indices for simvastatin and nigericin were observed in confirmatory HIV infection assays. This robust assay is adaptable to study HIV and heterologous viral pseudotypes. - Highlights: • Cre recombinase viral fusion assay screens cell-free or cell–cell entry inhibitors. • This Gag-iCre based assay is specific for the entry step of HIV replication. • Screened a library of known pharmacologic compounds for HIV fusion antagonists. • Many top hits were previously noted as HIV inhibitors, but here are classified as entry antagonists. Many top hits were previously noted as HIV inhibitors, but not as entry antagonists. • The assay is compatible with pseudotyping with HIV and heterologous viruses.

60 APPLIED LIFE SCIENCES↗

A novel cell-based assay to measure activity of Venezuelan equine encephalitis virus nsP2 protease

The encephalitic alphaviruses encode nsP2 protease (nsP2pro), which because of its vital role in virus replication, represents an attractive target for therapeutic intervention. To facilitate the discovery of nsP2 inhibitors we have developed a novel assay for quantitative measurement of nsP2pro activity in a cell-based format. The assay is based on a substrate fusion protein consisting of eGFP and Gaussia luciferase (Gluc) linked together by a small peptide containing a VEEV nsp2pro cleavage sequence. The expression of the substrate protein in cells along with recombinant nsP2pro results in cleavage of the substrate protein resulting in extracellular release of free Gluc. The Gluc activity in supernatants corresponds to intracellular nsP2pro-mediated substrate cleavage; thus, providing a simple and convenient way to quantify nsP2pro activity. Here, we demonstrate potential utility of the assay in identification of nsP2pro inhibitors, as well as in investigations related to molecular characterization of nsP2pro. - Highlights: • A novel cell-based assay to measure VEEV nsP2 protease activity was developed. • Assay utility was demonstrated for antiviral screening. • .The assay also proved to be useful in basic mechanistic studies of nsP2 protease.

60 APPLIED LIFE SCIENCES↗

Functional assignment of solute-binding proteins of ABC transporters using a fluorescence-based thermal shift assay.

We have used a fluorescence-based thermal shift (FTS) assay to identify amino acids that bind to solute-binding proteins in the bacterial ABC transporter family. The assay was validated with a set of six proteins with known binding specificity and was consistently able to map proteins with their known binding ligands. The assay also identified additional candidate binding ligands for several of the amino acid-binding proteins in the validation set. We extended this approach to additional targets and demonstrated the ability of the FTS assay to unambiguously identify preferential binding for several homologues of amino acid-binding proteins with known specificity and to functionally annotate proteins of unknown binding specificity. The assay is implemented in a microwell plate format and provides a rapid approach to validate an anticipated function or to screen proteins of unknown function. The ABC-type transporter family is ubiquitous and transports a variety of biological compounds, but the current annotation of the ligand-binding proteins is limited to mostly generic descriptions of function. The results illustrate the feasibility of the FTS assay to improve the functional annotation of binding proteins associated with ABC-type transporters and suggest this approach that can also be extended to other protein families.

59 BASIC BIOLOGICAL SCIENCES↗

Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference

Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We find that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.

59 BASIC BIOLOGICAL SCIENCES↗

A Targeted Mass Spectrometric Assay for Reliable Sensitive Hepcidin Quantification

Hepcidin, a cysteine-rich peptide hormone, secreted mainly by the liver, plays a central role in iron metabolism regulation. Emerging evidence suggests that disordered iron metabolism is a risk factor for various types of diseases including cancers. However, it remains challenging to apply current mass spectrometry (MS)-based hepcidin assays for precise quantification due to the low fragmentation efficiency of intact hepcidin as well as synthesis difficulties for the intact hepcidin standard. To address these issues we recently developed a reliable sensitive targeted MS assay for hepcidin quantification that uses fully alkylated rather than intact hepcidin as the internal standard. Limits of detection and quantification were determined to be <0.5 ng/mL and 1 ng/mL, respectively, which are better than those from currently available MS-based hepcidin assays. Application of the alkylated hepcidin assay to 70 clinical plasma samples (42 normal and 28 ovarian cancer patient samples) enabled reliable detection of endogenous hepcidin from the plasma samples, as well as conditioned culture media. The hepcidin concentrations ranged from 0.0 to 95.6 ng/mL across normal and cancer plasma specimens. Interestingly, cancer patients were found to have significantly higher hepcidin concentrations compared to normal patients (mean: 20.6 ng/ml for cancer; 5.94 ng/ml for normal) with the p value of <0.001. Our results demonstrate that the newly developed hepcidin assay has better sensitivity and quantification accuracy than current MS-based hepcidin assays without the challenges in synthesis of intact hepcidin standard and accurately determining its absolute amount.

59 BASIC BIOLOGICAL SCIENCES↗