Contrasting the characteristics of atmospheric pressure plasma jets operated with single and double dielectric material: physicochemical characteristics and application to bacterial killing

Abstract This study reports an experimental comparison of two types of atmospheric pressure plasma jets in terms of their fundamental plasma characteristics and efficacy in bacterial sterilization. The plasma jets are fabricated by inserting a high voltage electrode inside a one-end closed (double DBD plasma jet) or both ends open (single DBD plasma jet) quartz tubes which are further enclosed inside a second quartz tube containing a ground electrode. Both plasma jets are operated in contact with water surface by using a unipolar pulsed DC power supply with helium as the working gas. Results from electrical and time-resolved imaging show that the single DBD configuration induces 3–4 times higher accumulation of charges onto the water surface with significantly faster propagation of plasma bullets. These results are accompanied by the higher discharge intensity as well as stronger emissions from short-lived reactive species which were analyzed through optical emission spectroscopy at the plasma-water interface. The rotational temperature for the single DBD configuration was observed to be higher making it unsafe for direct treatments of sensitive biological targets. These characteristics of the single DBD configuration result in the production of more than two times higher concentration of H 2 O 2 in plasma activated water. Shielding of the HV electrode reduces the plasma potential which in turn reduces the electric field & electron energy at the plasma-water interface. The reduced electric field for the double DBD configuration was lower by ≈463 Td than the single DBD configuration. The bactericidal efficacy of the two configurations of the plasma jets were tested against Escherichia coli , a well studied Gram-negative bacterium that can be commensal and pathogenic in human body. Our results demonstrate that although single DBD plasma jet result in stronger antibacterial effects, the double DBD configuration could be safer.

Physics↗

Continuous manufacturing of carbon foam structures at atmospheric pressure

A method of manufacturing essentially crack-free carbon foam structures and carbon foam structures made in single-piece flow through a continuous kiln under inert atmosphere at atmospheric pressure. This process greatly reduces the cost to manufacture by reducing manufacturing time and increasing the ability to integrate automation equipment.

Olson, III, Rudolph Andrew↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manufacture of Carbon Foam in Continuous Process at Atmospheric Pressure

CFOAM LLC has been manufacturing CFOAM® vitreous carbon foam from coal in panel form for several years. The process is currently set up in batch mode as two steps, where the first step is conducted at very high pressure. In order to reduce cost and increase capacity, a new process for making carbon foam is being developed that can be performed at atmospheric pressure. This advance in turn would enable the development of a continuous manufacturing process, which is also being pursued. Both carbon foam panels and light weight aggregates are being investigate. Progress on the evolution of the pilot scale manufacturing plant and initial results of processing, microstructure, properties and performance of carbon foam products made using this new process will be discussed. This project is being supported by a cooperative agreement with the Department of Energy – National Energy Technology Laboratory (DE-FOA-0002185, Area of Interest 4: Coal-Derived Carbon Foam Produced via a Continuous Process, award number DE-FE-0031992).

01 COAL, LIGNITE, AND PEAT↗

Manufacture of Carbon Foam in Continuous Process at Atmospheric Pressure

CFOAM LLC has been manufacturing vitreous carbon foam from coal in panel form for several years. The process is currently set up in batch mode as two steps, where the first step is conducted at very high pressure. In order to reduce cost and increase capacity, a new process for making carbon foam is being developed that can be performed at atmospheric pressure. This advance in turn would enable the development of a continuous manufacturing process, which is also being pursued. Both carbon foam panels and light weight aggregates are being investigate. Progress on the evolution of the pilot scale manufacturing plant and initial results of processing, microstructure, properties and performance of carbon foam products made using this new process will be discussed. This project is being supported by a cooperative agreement with the Department of Energy – National Energy Technology Laboratory (DE-FOA-0002185, Area of Interest 4: Coal-Derived Carbon Foam Produced via a Continuous Process, award number DE-FE-0031992).

01 COAL, LIGNITE, AND PEAT↗

Manufacture of Carbon Foam in Continuous Process at Atmospheric Pressure

CFOAM LLC has been manufacturing vitreous carbon foam from coal in panel form for several years. The process is currently set up in batch mode as two steps, where the first step is conducted at very high pressure. In order to reduce cost and increase capacity, a new process for making carbon foam is being developed that can be performed at atmospheric pressure. This advance in turn would enable the development of a continuous manufacturing process, which is also being pursued. Both carbon foam panels and light weight aggregates are being investigate. Construction of the pilot scale manufacturing plant has been completed and results of processing, microstructure, properties and performance of carbon foam products made using this new process will be discussed. This project is being supported by a cooperative agreement with the Department of Energy – National Energy Technology Laboratory (DE-FOA-0002185, Area of Interest 4: Coal-Derived Carbon Foam Produced via a Continuous Process, award number DE-FE-0031992).

01 COAL, LIGNITE, AND PEAT↗

Non-thermal atmospheric pressure plasma–liquid synthesis of organic acids in aqueous solution from carbon monoxide

This work aims at understanding the conversion of CO to organic acids, namely oxalic acid and formic acid, using non-thermal atmospheric pressure plasma over aqueous solutions. CO exhibited significantly higher conversion to organic acids (more than 15×) compared to CO 2 under the same reaction conditions. The result bolsters a proposed two-step process for CO 2 fixation, whereby CO 2 is first converted to CO, and then CO is converted to organic acids. The organic acids produced from CO are intermediates in the water–gas shift (WGS) reaction of CO in the presence of an aqueous solution to dissolved CO 2 and hydrogen gas. Based on a simple thermodynamic analysis, the organic acid yield was increased by lowering the plasma–liquid reaction temperature using an ice bath to cool the reaction flask. The composition of the organic acids could be varied by changing the pH of the solution. Oxalate was formed in higher concentrations with increasing solution pH above the pK a of the radical species (CO 2 )˙ − . Below the pK a value, formate was the exclusive organic acid formed. The production of formate has a rather weak pH dependence but is enhanced slightly at a basic pH above 10. Furthermore, at basic pH, the effect of electrolyte concentration comes into play. Higher electrolyte concentrations, leading to shorter electrolyte Debye lengths, resulted in lowered organic acid yields. The highest yields of organic acids obtained in our system were 122 mg L −1 for oxalate and 77 mg L −1 for formate at an optimum 1 mM NaOH concentration in the starting solution. This work is a successful pioneering example of CO to organic acids conversion using non-thermal plasmas, which opens the pathway for a promising two-step conversion process of CO 2 to organic acids.

Sudagar, Alcina Johnson [Washington University in ↗

Characterization of Carbon Foam Products Made from Coal at Atmospheric Pressure

Carbon foam products are currently manufactured on a commercial scale utilizing a high-pressure autoclave in batch mode. In an effort to increase manufacturing speed and reduce cost, carbon foam products (both panels and aggregates) were produced at atmospheric pressure in a continuous belt kiln. Here, the microstructure, properties, and performance of these materials were characterized and assessed in various applications. Lightweight aggregate was explored for use as a proppant, as well as it use in concrete and asphalt. The thermal conductivity, water permeability, and fire resistance of panels were evaluated, and its performance with respect to screw pullout was compared against conventional building materials. Some interesting performance aspects and potential for future work was revealed. This work was supported by a cooperative agreement with the Department of Energy – National Energy Technology Laboratory (DE-FOA-0002185, Area of Interest 4: Coal-Derived Carbon Foam Produced via a Continuous Process, award number DE-FE-0031992).

01 COAL, LIGNITE, AND PEAT↗

Chemical Looping of Manganese to Synthesize Ammonia at Atmospheric Pressure: Sodium as Promoter

Abstract Affordable synthetic ammonia (NH 3 ) enables the production of nearly half of the food we eat and is emerging as a renewable energy carrier. Sodium‐promoted chemical looping NH 3 synthesis at atmospheric pressure using manganese (Mn) is here demonstrated. The looping process may be advantageous when inexpensive renewable hydrogen from electrolysis is available. Avoiding the high pressure of the Haber‐Bosch process by chemical looping using earth‐abundant materials may reduce capital cost, facilitate intermittent operation, and allow operation in geographic areas where infrastructure is less sophisticated. At this early stage, the data suggest that 0.28 m 3 of a 50 % porosity solid Mn bed may suffice to produce 100 kg NH 3 per day by chemical looping, with abundant opportunities for improvement.

Aframehr, Wrya Mohammadi↗

Method for forming perovskite layers using atmospheric pressure plasma

Improved deposition of optoelectronically active perovskite materials is provided with a two step process. In the first step, precursors are deposited on a substrate. In the second step, the deposited precursors are exposed to an atmospheric pressure plasma which efficiently cures the precursors to provide the desired perovskite thin film. The resulting films can have excellent optical properties combined with superior mechanical properties.

36 MATERIALS SCIENCE↗

Spatially resolved density measurements of singlet delta oxygen in a non-equilibrium atmospheric pressure plasma jet by molecular beam mass spectrometry

Singlet delta oxygen (O 2 (a 1 Δ g )), the first electronically excited state of O 2 , plays an important role in many applications. We report the first measurements of absolute densities of O 2 (a 1 Δ g ) in an atmospheric pressure plasma jet (APPJ) by molecular beam mass spectrometry (MBMS). The ability to measure axial and radial profiles of O 2 (a 1 Δ g ) impinging on a substrate in the effluent of the APPJ is a key advantage of the MBMS diagnostic method over previously reported optical methods. Here, the measured large O 2 (a 1 Δ g ) densities in the APPJ effluent, up to one order of magnitude higher than the O density, underline the potential importance of O 2 (a 1 Δ g ) in many applications using APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge (SCGD) spectrometry apparatus may comprise an SCGD source and a mass or ion mobility spectrometer. A method for ionizing a molecular analyte may comprise contacting the molecular analyte with a plasma discharge to form ions and separating the ions in a mass spectrometer or ion mobility spectrometer. The contacting step may occur under atmospheric pressure and/or ambient conditions. The molecular analyte may be fragmented by the plasma discharge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Plasma dynamics, instabilities and OH generation in a pulsed atmospheric pressure plasma with liquid cathode: a diagnostic study

Abstract While plasma–liquid interactions have been an important focus in the plasma research community, the impact of the strong coupling between plasma and liquid on plasma properties and processes remains not fully understood. In this work, we report on the impact of the applied voltage, pulse width and liquid conductivity on the plasma morphology and the OH generation for a positive pulsed DC atmospheric pressure plasma jet with He–0.1% H 2 O mixture interacting with a liquid cathode. We adopted diagnostic techniques of fast imaging, 2D laser induced fluorescence of OH and Thomson scattering spectroscopy. We show that plasma instabilities and enhanced evaporation occur and have a significant impact on the OH generation. At elevated plasma energies, it is found that the plasma contracts due to a thermal instability through Ohmic heating and the contraction coincides with a depletion in the OH density in the core due to electron impact dissociation. For lower plasma energies, the instability is suppressed/delayed by the equivalent series resistor of the liquid electrode. An estimation of the energy flux from the plasma to the liquid shows that the energy flux of the ions released into the liquid by positive ion hydration is dominant, and significantly larger than the energy needed to evaporate sufficient amount of water to account for the measured H 2 O concentration increase near the plasma–liquid interface.

Physics↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Coupling of the Liquid Sampling–Atmospheric Pressure Glow Discharge to Orbitrap Mass Analyzers for Uranium Isotope Ratio Analysis: Evolution of the Methodology and Implications to the Field

Just over a decade ago, a truly outside-of-the-box approach to isotope ratio mass spectrometry (IRMS) was undertaken between research groups at Clemson University and the Pacific Northwest National Laboratory. The original motivation dealt with projections as to whether or not microplasmas could be developed into practical elemental ionization sources, perhaps for transportable analysis applications. In particular, the use of the liquid sampling–atmospheric pressure glow discharge (LS-APGD) was pursued. Its interfacing to an ultra-high resolution Orbitrap platform, proved not only facile, but opened up a wealth of potential applications. Here, we lay out a historical, tutorial description of the interfacing and the evolution of the methodology regarding IRMS of uranium. Practical challenges and opportunities are described, which hopefully provide guidance to further applications in high resolution IRMS. It is hoped that, while detailed and lengthy, the didactic nature of the presentation provides experimental insights and tips, and also serves as an homage to our very good friend, Professor Gary M. Hieftje, whose scientific inspiration and comradery have been immeasurably important in our own careers.

Koppenaal, David W.↗