Search NASA⌕ Search

SEARCH · Search NASA

Results for “Audibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Force-Balance Dynamic Display

Balance dynamic display unit (BDDU) is compact system conditioning six dynamic analog signals so they are monitored simultaneously in real time on single-trace oscilloscope. Typical BDDU oscilloscope display in scan mode shows each channel occupying one-sixth of total trace. System features two display modes usable with conventional, single-channel oscilloscope: multiplexed six-channel "bar-graph" format and single-channel display. Two-stage visual and audible limit alarm provided for each channel.

Ferris, Alice T.↗

High-intensity tone generation by aeroacoustic sources

An experimental investigation has been carried out on the production of high-intensity tones by axisymmetric ring cavities. Maximum sound production occurs during an acoustic resonance at Strouhal numbers, which depend only on the local flow velocity independent of cavity location. Values of sound pressure of about 115 dB at 1-m distance can be generated by axisymmetric ring cavities on projectiles moving at a relatively low flight speed equal to 70 m/s. Frequencies in the audible range up to several kilohertz can be generated aeroacoustically. A simple analytical model has been developed to explain the experimental observations.

Shakkottai, P.↗

Visual display and alarm system for wind tunnel static and dynamic loads

A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanism, or tunnel shutdown.

Hanly, Richard D.↗

Vector excitation coding with dynamic bit allocation

Vector excitation coding (VXC) has shown promise for digital transmission of fairly high communications quality speech at low bit rates, but current version of the algorithm still suffer from audible degradations, particularly at 4.8 kb/s. The authors examine the technique of dynamic bit allocation (DBA) to improve the performance of VXC for a given bit rate. The approach is based on the observation that the minimum bit rate needed to code adequately both the long-term and short-term predictors in VXC varies dynamically with time. Therefore, in frames where fewer bits suffice for the predictors, the unneeded bits can be reallocated to other coder parameter sets such as excitation vectors. By dynamically distributing available bits among the different coder parameter sets while keeping the total number of bits in each frame fixed, it is possible to improve overall coder performance without increasing bit rate.

Yong, Mei↗

The helmet-mounted visual system in flight simulation

An account is given of the application of fiber-optic helmet-mounted display systems to flight simulation tasks for complex combat mission scenarios involving numerous external aircraft, audible communications, and various types of threats. Such helmets, which although custom-made for each pilot are far less expensive than image-projection systems, consist of two 3-in. diameter 'optical pancake windows' mounted in front of the pilot's eyes to which images are transferred through fiber-optic cables from four high-brightness light-valve projectors. Head-position information is provided by an optical tracking system. The pancake window displays are semitransparent and allow cockpit controls and displays to be viewed normally.

Cook, Anthony M.↗

Laser Schlieren System Detects Sounds Of Leaks

Hostile environments monitored safely and noninvasively. Modified laser schlieren system acts as microphone to detect sounds of leaks remotely. Sensitive to acoustical frequencies above audible range and especially suited for monitoring leaks of high-pressure steam from boilers or chemical vapors from processing equipment. Does not require placement of delicate equipment in harsh environment monitored, and no contact needed with boiler or other unit being monitored. Detects sound waves via variation of index of refraction of air at acoustical frequencies. Used to monitor sound frequencies beyond range of human hearing.

Shakkottai, Parthasarathy P.↗

Rapidly quantifying the relative distention of a human bladder

A device and method of rapidly quantifying the relative distention of the bladder in a human subject are disclosed. The ultrasonic transducer which is positioned on the subject in proximity to the bladder is excited by a pulser under the command of a microprocessor to launch an acoustic wave into the patient. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer, when it is received, amplified and processed by the receiver. The resulting signal is digitized by an analog-to-digital converter under the command of the microprocessor and is stored in the data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy; and based on programmed scientific measurements and individual, anatomical, and behavioral characterists of the specific subject as contained in the program memory, sends out a signal to turn on any or all of the audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

En route noise of turboprop aircraft and their acceptability: Report of tests

The development of propfan-powered aircraft has been observed with great interest. It is obvious that during cruising flight, the aircraft powerplant (propellers) cause a noise clearly perceivable on the ground. It is the audible frequency spectrum of the propfan powerplants relative to the high tip speeds that presents the problem. A flight test was conducted on 30 April, 1989 at the Frankfurt Airport. Results of the test flight are present.

Held, Wolf↗

Long-range vertical propagation

Development of the advanced turboprop has led to concerns about en route noise. Advanced turboprops generate low-frequency, periodic noise signatures at relatively high levels. As demonstrated in a flight test of NASA Lewis Research Center's Propfan Test Assessment (PTA) airplane in Alabama in October 1987, the noise of an advanced turboprop operating at cruise altitudes can be audible on the ground. The assessment of the en route noise issue is difficult due to the variability in received noise levels caused by atmospheric propagation and the uncertainty in predicting community response to the relatively low-level en route noise, as compared to noise associated with airport operations. The En Route Noise Test was designed to address the atmospheric propagation of advanced turboprop noise from cruise altitudes and consisted of measuring the noise of an advance turboprop at cruise in close proximity to the turboprop and on the ground. Measured and predicted ground noise levels are presented.

Willshire, William L., Jr.↗

Spin bearing retainer design optimization

The dynamics behavior of spin bearings for momentum wheels (control-moment gyroscope, reaction wheel assembly) is critical to satellite stability and life. Repeated bearing retainer instabilities hasten lubricant deterioration and can lead to premature bearing failure and/or unacceptable vibration. These instabilities are typically distinguished by increases in torque, temperature, audible noise, and vibration induced by increases into the bearing cartridge. Ball retainer design can be optimized to minimize these occurrences. A retainer was designed using a previously successful smaller retainer as an example. Analytical methods were then employed to predict its behavior and optimize its configuration.

Boesiger, Edward A.↗

NSI operations center

The NASA Science Internet (NSI) Network Operations Staff is responsible for providing reliable communication connectivity for the NASA science community. As the NSI user community expands, so does the demand for greater interoperability with users and resources on other networks (e.g., NSFnet, ESnet), both nationally and internationally. Coupled with the science community's demand for greater access to other resources is the demand for more reliable communication connectivity. Recognizing this, the NASA Science Internet Project Office (NSIPO) expands its Operations activities. By January 1990, Network Operations was equipped with a telephone hotline, and its staff was expanded to six Network Operations Analysts. These six analysts provide 24-hour-a-day, 7-day-a-week coverage to assist site managers with problem determination and resolution. The NSI Operations staff monitors network circuits and their associated routers. In most instances, NSI Operations diagnoses and reports problems before users realize a problem exists. Monitoring of the NSI TCP/IP Network is currently being done with Proteon's Overview monitoring system. The Overview monitoring system displays a map of the NSI network utilizing various colors to indicate the conditions of the components being monitored. Each node or site is polled via the Simple Network Monitoring Protocol (SNMP). If a circuit goes down, Overview alerts the Network Operations staff with an audible alarm and changes the color of the component. When an alert is received, Network Operations personnel immediately verify and diagnose the problem, coordinate repair with other networking service groups, track problems, and document problem and resolution into a trouble ticket data base. NSI Operations offers the NSI science community reliable connectivity by exercising prompt assessment and resolution of network problems.

Zanley, Nancy L.↗

Rapidly quantifying the relative distention of a human bladder

A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

Two-Band Pyrometers Detect Hydrogen Fires

Two-band infrared pyrometers detect small hydrogen fires at greater distances in full daylight being developed. Detectors utilize part of infrared spectrum in which signals from hydrogen flames 10 to the 3rd power to 10 to the 4th power times as intense as ultraviolet region of current detectors. Utilize low-loss infrared lenses for focusing and for limiting fields of view to screen out spurious signals from nearby sources. Working distances of as much as 100 meters possible. Portable, battery-powered unit gives audible alarm, in form of increase in frequency of tone, when aimed at hydrogen fire.

Collins, J. David↗

Engine Performance and Knock Rating of Fuels for High-output Aircraft Engines

Data are presented to show the effects of inlet-air pressure, inlet-air temperature, and compression ratio on the maximum permissible performance obtained on a single-cylinder test engine with aircraft-engine fuels varying from a fuel of 87 octane number to one 100 octane number plus 1 ml of tetraethyl lead per gallon. The data were obtained on a 5-inch by 5.75-inch liquid-cooled engine operating at 2,500 r.p.m. The compression ratio was varied from 6.50 to 8.75. The inlet-air temperature was varied from 120 to 280 F. and the inlet-air pressure from 30 inches of mercury absolute to the highest permissible. The limiting factors for the increase in compression ratio and in inlet-air pressure was the occurrence of either audible or incipient knock. The data are correlated to show that, for any one fuel,there is a definite relationship between the limiting conditions of inlet-air temperature and density at any compression ratio. This relationship is dependent on the combustion-gas temperature and density relationship that causes knock. The report presents a suggested method of rating aircraft-engine fuels based on this relationship. It is concluded that aircraft-engine fuels cannot be satisfactorily rated by any single factor, such as octane number, highest useful compression ratio, or allowable boost pressure. The fuels should be rated by a curve that expresses the limitations of the fuel over a variety of engine conditions.

Rothbrock, A M↗

Correlation of knocking characteristics of fuels in an engine having a hemispherical combustion chamber

Data are presented to show the effects of inlet-air pressure, inlet-air temperature, and compression ratio on the maximum permissible performance obtained with having a hemispherical-dome combustion chamber. The five aircraft-engine fuels used have octane numbers varying from 90 to 100 plus 2 ml of tetraethyl lead per gallon. The data were obtained on a 5 1/4-inch by 4 3/4-inch liquid-cooled engine operating at 2,500 r.p.m. The compression ratio was varied from 6.0 to 8.9. The inlet-air temperature was varied from 110 to 310 F. For each set of conditions, the inlet-air pressure was increased until audible knock occurred and then reduced 2 inches of mercury before data were recorded. The results for each fuel can be correlated by plotting the calculated end-gas density factor against the calculated end-gas temperature. Measurements of spark-plugs, cutting off the switch to one spark plug lowered the electrode temperature of that plug from a value of 1,365 F to a value of 957 F. The results indicate that the surface temperatures of combustion-chamber areas which become new sources of ignition markedly increase after ignition.

Rothrock, A M↗

The relative performance obtained with several methods of control of an overcompressed engine using gasoline

This report presents some results obtained during an investigation to determine the relative characteristics for several methods of control of an overcompressed engine using gasoline and operating under sea-level conditions. For this work, a special single cylinder test engine, 5-inch bore by 7-inch stroke, and designed for ready adjustment of compression ratio, valve timing and valve lift while running, was used. This engine has been fully described in NACA-TR-250. Tests were made at an engine speed of 1,400 R. P. M. for compression ratios ranging from 4.0 to 7.6. The air-fuel ratios were on the rich side of the chemically correct mixture and were approximately those giving maximum power. When using plain domestic gasoline, detonation was controlled to a constant, predetermined amount (audible), such as would be permissible for continuous operation, by (a) throttling the carburetor, (b) maintaining full throttle but greatly retarding the ignition, and (c) varying the timing of the inlet valve to reduce the effective compression ratio. From the results of the tests, it may be concluded that method (b) gives the best all-round performance and, being easily employed in service, appears to be the most practicable method for controlling an overcompressed engine using gasoline at low altitudes.

Gardiner, Arthur W↗

Low-Noise Spiral Bevel Gears

Modified spiral bevel gears that generate relatively little noise and vibration designed and fabricated for use in U.S. Army OH-58D helicopter. Noise reduced by 12 to 19 dB. Similar low-noise, low-vibration spiral bevel gears used in other helicopters, with consequent benefits in comfort and health of pilots and passengers, enhancement of pilots' performance and safety through reduction of audible distraction, and reduction in cost and weight of helicopters through reduction in amount of sound-proofing material. Low-noise, low-vibration spiral bevel gears also used in drive axles of cars and trucks for smoother, quieter rides.

Lewicki, David G.↗

Evaluation of iconic versus F-map microburst displays

Previous studies have shown graphical presentation methods of hazardous wind shear to be superior to textual or audible warnings alone. Positional information and the strength of the hazard were observed to be and were cited by pilots as the most important factors in a display. In this experiment the use of the three different graphical presentations of hazardous wind shear are examined. Airborne predictive detectors of wind shear enable the dissemination of varying levels of information. The effectiveness of iconic and mapping display modes of different complexities are addressed through simulation and analysis. Different positional and time-varying situations are presented in a 'part-task' Boeing 767 simulator using data from actual microburst events. Experienced airline pilots fly approach profiles using both iconic and F-map wind shear alerting displays. Microburst accompanied each event is also shown to the pilot. Mapping display types are expected to be found exceptionally efficient at conveying location comparison information while iconic displays simplify the threat recognition process. Preliminary results from the simulator study are presented. Recommendations concerning the suitability of multilevel iconic and mapping displays are made. Situational problems with current display prototypes are also addressed.

Salzberger, Mark↗