Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automated calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

NXREFINE

NXRefine implements a complete workflow for both data acquisition and reduction of single crystal diffuse x-ray scattering collected as a series of area detector frames during continuous sample rotation. The data are stored in HDF5 files, which conform to the NeXus data format standard. These files contain a comprehensive set of metadata, including the incident wavelength, powder calibration scans used to define detector distances, beam centers, and yaw, pitch, and roll corrections. Automated peak searches of the three-dimensional data arrays define a set of Bragg peaks that are used to define an orientation matrix, defined according to Busing and Levy, which is then used to transform the data from angular coordinates to reciprocal space coordinates using the CCTW program. Multiple rotations at different detector translations and offset rotation axes are combined to ensure that there are no gaps in the reconstructed data, and allow the construction of masks to eliminate detector artifacts due to Compton scattering within the sensor layers. Finally, the data can be transformed into 3D-ΔPDF maps using the punch-and-fill method after symmetrization.

OSBORN, RAYMOND↗

The GammaSpec Package for Automated Gamma-ray Analysis (V.1.0)

This report describes the GammaSpec package, a tool developed to automate the analysis and comparison of gamma-ray spectra. The goal of this tool is to drastically reduce, or even eliminate, currently time consuming processes for comparing large sets of gamma-ray measurements. There are a number of potential applications for this work throughout the laboratory, but particularly within Global Security. Current work flows where large numbers of measured spectra must be compared for anomolies and outliers often consist of loading and visually inspecting individual spectra, or utilizing small-batch tools. One such example is the PeakEasy tool also developed at LANL. PeakEasy has a robust and tested feature set for calibrating, identifying, and fitting gamma-ray spectra. However it’s intention was not for batch processing and automated comparison of large numbers of spectra. This tool is not intended to replace PeakEasy in an analyzers arsenal, but to instead augment it. The intention here is to automate the isolation of spectra of particular interest, which can then be studied in further detail. This report is arranged as follows. Section 2 lays out the design goals and desired functionality of the package. Section 3 describes the algorithms developed and chosen to accomplish those goals. Section 4 describes the primary interaction with the tool, as well as it’s resulting output. Following these sections, results are presented from a set of example datasets from High Purity Germanium (HPGe) detectors in Sec. 5. Finally, the current status is summarized in Sec. 6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a hybrid neural network and transfer learning model for optimized ICP-MS/MS operation

Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maxar Initial Satellite Characterization

This documents reports on the initial Assessment Specification and Validation (ASV) of Maxar satellite imagery as a geolocation system. Validation is a prerequisite for using geolocation for applications that require quantified uncertainty. A Variance Component Estimation (VCE) calibration of the provider’s co- variance matrices concluded that they were exaggerated. However, we currently lack enough independent validation data to quantify the improvement from the VCE. The current ASV process is slow and expensive. It will not be able to keep up with growing numbers of satellite systems. We proposed a method to automate ASV using controlled imagery. The proposed method will allow us to keep up with new sensors and generate unbounded amounts of calibration data, leading to unprecedented accuracy.

47 OTHER INSTRUMENTATION↗

SIDDA: SInkhorn Dynamic Domain Adaptation for image classification with equivariant neural networks

Modern neural networks (NNs) often do not generalize well in the presence of a ‘covariate shift’; that is, in situations where the training and test data distributions differ, but the conditional distribution of classification labels given the data remains unchanged. In such cases, NN generalization can be reduced to a problem of learning more robust, domain-invariant features. Domain adaptation (DA) methods include a broad range of techniques aimed at achieving this; however, these methods have struggled with the need for extensive hyperparameter tuning, which then incurs significant computational costs. In this work, we introduce SInkhorn Dynamic Domain Adaptation (SIDDA), an out-of-the-box DA training algorithm built upon the Sinkhorn divergence, that can achieve effective domain alignment with minimal hyperparameter tuning and computational overhead. We demonstrate the efficacy of our method on multiple simulated and real datasets of varying complexity, including simple shapes, handwritten digits, real astronomical observations, and remote sensing data. These datasets exhibit covariate shifts due to noise, blurring, differences between telescopes, and variations in imaging wavelengths. SIDDA is compatible with a variety of NN architectures, and it works particularly well in improving classification accuracy and model calibration when paired with symmetry-aware equivariant NNs (ENNs). We find that SIDDA consistently enhances the generalization capabilities of NNs, achieving up to a ${\approx}40\%$ improvement in classification accuracy on unlabeled target data, while also providing a more modest performance gain of $\lesssim 1\%$ on labeled source data. We also study the efficacy of DA on ENNs with respect to the varying group orders of the dihedral group DN, and find that the model performance improves as the degree of equivariance increases. Finally, if SIDDA achieves proper domain alignment, it also enhances model calibration on both source and target data, with the most significant gains in the unlabeled target domain—achieving over an order of magnitude improvement in the expected calibration error and Brier score. SIDDA’s versatility across various NN models and datasets, combined with its automated approach to domain alignment, has the potential to significantly advance multi-dataset studies by enabling the development of highly generalizable models.

79 ASTRONOMY AND ASTROPHYSICS↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep learning uncertainty quantification for clinical text classification

Machine learning algorithms are expected to work side-by-side with humans in decision-making pipelines. Thus, the ability of classifiers to make reliable decisions is of paramount importance. Deep neural networks (DNNs) represent the state-of-the-art models to address real-world classification. Although the strength of activation in DNNs is often correlated with the network’s confidence, in-depth analyses are needed to establish whether they are well calibrated. In this paper, we demonstrate the use of DNN-based classification tools to benefit cancer registries by automating information extraction of disease at diagnosis and at surgery from electronic text pathology reports from the US National Cancer Institute (NCI) Surveillance, Epidemiology, and End Results (SEER) population-based cancer registries. In particular, we introduce multiple methods for selective classification to achieve a target level of accuracy on multiple classification tasks while minimizing the rejection amount—that is, the number of electronic pathology reports for which the model’s predictions are unreliable. We evaluate the proposed methods by comparing our approach with the current in-house deep learning-based abstaining classifier. Overall, all the proposed selective classification methods effectively allow for achieving the targeted level of accuracy or higher in a trade-off analysis aimed to minimize the rejection rate. On in-distribution validation and holdout test data, with all the proposed methods, we achieve on all tasks the required target level of accuracy with a lower rejection rate than the deep abstaining classifier (DAC). Interpreting the results for the out-of-distribution test data is more complex; nevertheless, in this case as well, the rejection rate from the best among the proposed methods achieving 97% accuracy or higher is lower than the rejection rate based on the DAC. We show that although both approaches can flag those samples that should be manually reviewed and labeled by human annotators, the newly proposed methods retain a larger fraction and do so without retraining—thus offering a reduced computational cost compared with the in-house deep learning-based abstaining classifier.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Image Products Acquired from Mid-Sized Uncrewed Aerial Systems for Land–Atmosphere Studies

We assess the viability of deploying commercially available multispectral and thermal imagers designed for integration on small uncrewed aerial systems (sUASs, <25 kg) on a mid-size Group-3-classification UAS (weight: 25–600 kg, maximum altitude: 5486 m MSL, maximum speed: 128 m/s) for the purpose of collecting a higher spatial resolution dataset that can be used for evaluating the surface energy budget and effects of surface heterogeneity on atmospheric processes than those datasets traditionally collected by instrumentation deployed on satellites and eddy covariance towers. A MicaSense Altum multispectral imager was deployed on two very similar mid-sized UASs operated by the Atmospheric Radiation Measurement (ARM) Aviation Facility. This paper evaluates the effects of flight on imaging systems mounted on UASs flying at higher altitudes and faster speeds for extended durations. We assess optimal calibration methods, acquisition rates, and flight plans for maximizing land surface area measurements. We developed, in-house, an automated workflow to correct the raw image frames and produce final data products, which we assess against known spectral ground targets and independent sources. We intend this manuscript to be used as a reference for collecting similar datasets in the future and for the datasets described within this manuscript to be used as launching points for future research.

47 OTHER INSTRUMENTATION↗

Milone eTape Liquid Level Sensor Laboratory Calibration with a Commercial 12.2 cm HS-Flume and 3D Printed 4 cm Micro-HS-Flumes

The NGEE Arctic Rainfall Simulator (NARS) is a variable intensity rainfall simulator (RFS) with a frame design based on the Humphry et al. (2002) RFS and a water delivery system based on the Walnut Gulch (Paige et al., 2004) RFS. The NARS uses an aluminum frame that is fully deconstructable for transportation to field locations and a water system that enables variable rain intensity. Prior to field deployment, H-flume discharge and the corresponding Milone eTape Liquid Level Sensor (eTape) resistance values were measured in the laboratory so that discharge measurements from the NGEE Arctic Rainfall Simulator could be automated. eTape resistance was measured with increasing fluid heights for the full range of the eTape to calculate sensor detection limits and resolution. The eTape was calibrated to both a commercially available 12.2 cm HS-flume and a 3D printed 4 cm Micro-HS-flume. This data package contains two .csv files, one for the eTape calibration and the other for the flume calibrations, and two .stl files to 3D print the 4 cm Micro-HS-Flume design with a 1 cm x 3.6 cm stilling well opening. The .stl files can be opened in most 3D printing or CAD programs/software. Two .kml files of the laboratory location and broader area where testing was conducted are also included in this data package.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Automated Cloud Based Long Short-Term Memory Neural Network Based SWE Prediction

Snow derived water is a critical component of the US water supply. Measurements of the Snow Water Equivalent (SWE) and associated predictions of peak SWE and snowmelt onset are essential inputs for water management efforts. This paper aims to develop an integrated framework for real-time data ingestion, estimation, prediction and visualization of SWE based on daily snow datasets. In particular, we develop a data-driven approach for estimating and predicting SWE dynamics using the Long Short-Term Memory neural network (LSTM) method. Our approach uses historical datasets (precipitation, air temperature, SWE, and snow thickness) collected at NRCS Snow Telemetry (SNOTEL) stations to train the LSTM network and current year data to predict SWE behavior. The performance of our prediction was compared for different prediction dates and prediction training datasets. Our results suggest that the proposed LSTM network can be an efficient tool for forecasting the SWE timeseries, as well as Peak SWE and snowmelt timing. Results showed that the window size impacts the model performance (where the Nash Sutcliffe efficiency (NSE) ranged from 0.96 to 0.85 and the Rooted Mean Square Error (RMSE) ranged from 0.038 to 0.07) with an optimum number that should be calibrated for different stations and climate conditions. In addition, by implementing the LSTM prediction capability in a cloud based site-monitoring platform, we automate model-data integration. By making the data accessible through a graphical web interface and an underlying API which exposes both training and prediction capabilities. The associated results can be made easily accessible to a broad range of stakeholders.

54 ENVIRONMENTAL SCIENCES↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

DayCent data and results for "Robust paths to net greenhouse gas mitigation and negative emissions via advanced biofuels"

DayCent data and results for:J. L. Field, T. L. Richard, E. A. Smithwick, H. Cai, M. S. Laser, D. S. LeBauer, S. P. Long, K. Paustian, Z. Qin, J. J. Sheehan, P. Smith, M. Q. Wang, L. R. Lynd, Robust paths to net greenhouse gas mitigation and negative emissions via advanced biofuels. Proceedings of the National Academy of Sciences (2020). https://doi.org/10.1073/pnas.1920877117 This zip file contains a UNIX-format DayCent model executable, input files, automation code, and associated directory structure necessary to re-produce the DayCent analysis underlying the manuscript. The main script 'autodaycent.py' (written for Python 2.7) opens an interactive command line routine that facilitates:* Calibrating the DayCent pine growth model.* Initializing DayCent for a set of case studies sites.* Executing an ensemble of model runs representing case study site reforestation, grassland restoration, or conversion to switchgrass cultivation. * Results analysis & generation of manuscript Fig. 3. Note that the interactive analysis code requires that all input files to be contained in the directory structure as uploaded, without modification. Executable versions of the DayCent model (https://www.nrel.colostate.edu/projects/daycent/) compatible with other operating systems are available upon request.Please send questions/comments to John.L.Field@gmail.com

Agro-ecosystem function and prediction↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Mesoscale Science Data Analytics

This is software that will be used to do data analytics in experimental workflows for x-ray mesoscale science. This tool set will provide a mechanism for supporting experiments in many ways, from collecting calibration information and raw data, to managing and viewing data to extracting crystallographic and physical parameters. It will eventually include development of a fully automated workflow that will include statistical information and prediction capabilities to support the scientists in decision-making and replanning their experiments when necessary.

Sweeney, Christine↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

DAKOTA (Design Analysis Kit for Optimization and Terascale) v.6.14

Sandia's Dakota software supports science and engineering transformation through advanced exploration of simulations. Specifically, Dakota manages and analyzes ensembles of simulations to provide broader and deeper perspective for analysts and decision makers. This enables them to: (1) enhance understanding of risk, (2) improve products, and (3) assess simulation credibility. In its simplest mode, Dakota can automate typical parameter variation studies through a generic interface to a computational model. Dakota also delivers advanced parametric analysis techniques enabling design exploration, optimization, model calibration, risk analysis, and quantification of margins and uncertainty with such models. It directly supports verification and validation activities. The algorithms implemented in Dakota aim to address challenges in performing these analyses with complex science and engineering models from desktop to high performance computers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-10468 O

Adams, BrianM.↗

DAKOTA (Design Analysis Kit for Optimization and Terascale) v.6.16

Sandia's Dakota software supports science and engineering transformation through advanced exploration of simulations. Specifically, Dakota manages and analyzes ensembles of simulations to provide broader and deeper perspective for analysts and decision makers. This enables them to: (1) enhance understanding of risk, (2) improve products, and (3) assess simulation credibility. In its simplest mode, Dakota can automate typical parameter variation studies through a generic interface to a computational model. Dakota also delivers advanced parametric analysis techniques enabling design exploration, optimization, model calibration, risk analysis, and quantification of margins and uncertainty with such models. It directly supports verification and validation activities. The algorithms implemented in Dakota aim to address challenges in performing these analyses with complex science and engineering models from desktop to high performance computers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-10468 O

Adams, BrianM.↗