Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Toward Automated Sampling of Polymorph Nucleation and Free Energies with the SGOOP and Metadynamics

Understanding the driving forces behind the nucleation of different polymorphs is of great importance for material sciences and the pharmaceutical industry. This includes understanding the reaction coordinate that governs the nucleation process and correctly calculating the relative free energies of different polymorphs. Here, we demonstrate, for the prototypical case of urea nucleation from the melt, how one can learn such a one-dimensional reaction coordinate as a function of prespecified order parameters and use it to perform efficient biased all-atom molecular dynamics simulations. The reaction coordinate is learnt as a function of the generic thermodynamic and structural order parameters using the “spectral gap optimization of order parameters (SGOOP)” approach [Tiwary, P. and Berne, B. J. Proc. Natl. Acad. Sci. U.S.A. (2016)] and is biased using well-tempered metadynamics simulations. The reaction coordinate gives insights into the role played by different structural and thermodynamics order parameters, and the biased simulations obtain accurate relative free energies for different polymorphs. This includes an accurate prediction of the approximate pressure at which urea undergoes a phase transition and one of the metastable polymorphs becomes the most stable conformation. Here, we believe the ideas demonstrated in this work will facilitate efficient sampling of nucleation in complex, generic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated defect detection in spent nuclear fuel using combine Cerenkov and Gamma Emission Tomography data

Spent fuel monitoring and characterization has been a pillar of safeguards and nuclear facility monitoring for many years. The Digital Cerenkov Viewing Device (DCVD) has been used since the 1980s as a method of defect detection in spent fuel. In recent years, the accounting of large quantities of spent fuel before storage has renewed interest in this relatively quick and inexpensive method. This has an impact not only in safeguards, but also in for nuclear power facilities, as accounting can be a long and arduous process. Additionally, the DCVD demonstrates limited accuracy in more complex cases such as substitution of a fuel rod with steel, or a partial defect detection. A second method, Gamma Emission Tomography (GET) has been explored as an improved defect detection method, but is much more expensive and invasive than DCVD. This work identifies deficiencies in both methods, and proposes a combination of data gathered from each method to address these deficiencies for improved spent fuel characterization. Initial results are promising, showing 97% detection of a single missing fuel rod when the data types are combined, versus approximately 50% and 70%respectively for DCVD and GET data on their own. Finally, these classification results are obtained with algorithms derived from facial recognition and applied to this problem, yielding unique accuracy in near real-time while also maintaining the information barrier between output and measurement desired in safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIXiE: an algorithm for automated ion mobility arrival time extraction and collision cross section calculation using global data association

Abstract Motivation Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of data that can then be used to create a reference library of experimental CCS values for use in high throughput omics analyses. Results We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. Availability and implementation PIXiE is an open-source tool, freely available on Github. The documentation, source code of the software, and a GUI can be found at https://github.com/PNNL-Comp-Mass-Spec/PIXiE and the source code of the backend workflow library used by PIXiE can be found at https://github.com/PNNL-Comp-Mass-Spec/IMS-Informed-Library. Supplementary information Supplementary data are available at Bioinformatics online.

Ma, Jian↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗