Search NASA⌕ Search

SEARCH · Search NASA

Results for “Autonomous measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Tech Briefs, June 2007

Topics covered include: High-Accuracy, High-Dynamic-Range Phase-Measurement System; Simple, Compact, Safe Impact Tester; Multi-Antenna Radar Systems for Doppler Rain Measurements; 600-GHz Electronically Tunable Vector Measurement System; Modular Architecture for the Measurement of Space Radiation; VLSI Design of a Turbo Decoder; Architecture of an Autonomous Radio Receiver; Improved On-Chip Measurement of Delay in an FPGA or ASIC; Resource Selection and Ranking; Accident/Mishap Investigation System; Simplified Identification of mRNA or DNA in Whole Cells; Printed Multi-Turn Loop Antennas for RF Biotelemetry; Making Ternary Quantum Dots From Single-Source Precursors; Improved Single-Source Precursors for Solar-Cell Absorbers; Spray CVD for Making Solar-Cell Absorber Layers; Glass/BNNT Composite for Sealing Solid Oxide Fuel Cells; A Method of Assembling Compact Coherent Fiber-Optic Bundles; Manufacturing Diamond Under Very High Pressure; Ring-Resonator/Sol-Gel Interferometric Immunosensor; Compact Fuel-Cell System Would Consume Neat Methanol; Algorithm Would Enable Robots to Solve Problems Creatively; Hypothetical Scenario Generator for Fault-Tolerant Diagnosis; Smart Data Node in the Sky; Pseudo-Waypoint Guidance for Proximity Spacecraft Maneuvers; Update on Controlling Herds of Cooperative Robots; and Simulation and Testing of Maneuvering of a Planetary Rover.

Source record↗

One- and Two-Band Sensors and Algorithms to Derive aCDOM(440) from Global Above- and In-Water Optical Observations

The colored (or chromophoric, depending on the literature) dissolved organic matter (CDOM) spectral absorption coefficient, aCDOM(λ), is a variable of global interest that has broad application in the study of biogeochemical processes. Within the funding for scientific research, there is an overarching trend towards increasing the scale of observations both temporally and spatially, while simultaneously reducing the cost per sample, driving a systemic shift towards autonomous sensors and observations. Legacy aCDOM(λ) measurement techniques can be cost-prohibitive and do not lend themselves toward autonomous systems. Spectrally rich datasets carefully collected with advanced optical systems in diverse locations that span a global range of water bodies, in conjunction with appropriate quality assurance and processing, allow for the analysis of methods and algorithms to estimate aCDOM(440) from spectrally constrained one- and two-band subsets of the data. The resulting algorithms were evaluated with respect to established fit-for-purpose criteria as well as quality assured archival data. Existing and proposed optical sensors capable of exploiting the algorithms and intended for autonomous platforms are identified and discussed. One-band in-water algorithms and two-band above-water algorithms showed the most promise for practical use (accuracy of 3.0% and 6.5%, respectively), with the latter demonstrated for an airborne dataset.

ocean color↗

Initial Trade Study for In-line Silver Sensor for Spacecraft Potable Water Systems

Ionic silver is currently baselined as the biocide for microbial control in potable water systems for future space exploration missions. In-line monitoring of silver ion concentration is desired for system feedback control to introduce and maintain sufficient and safe levels of biocide in the water. To date, NASA testing of silver biocide system prototypes has made use of an Ion-Selective Electrode (ISE) for in-line silver concentration measurements. However, known issues with ISE technology have continued to motivate a search for alternate sensor systems. Although devices capable of detecting silver are available for terrestrial applications, these systems are generally not well-suited for the unique demands of spaceflight. Desired attributes include: low weight, volume, and power consumption; stable, autonomous, and in-line measurement capability; long calibration lifetime; and limited maintenance requirements. This paper provides the results from a preliminary trade study conducted on three candidate silver sensor technologies: ISEs, Anodic Stripping Voltammetry (ASV), and Fiber Optic Chemical Sensors (FOCS). The review of these technologies includes the rationale for their selection, an overview of the principles of their operation, and a detailed assessment of their strengths and weaknesses relative to the anticipated requirements of future spacecraft applications. The study concluded that none of the currently-available versions of these technologies is suitable for immediate application to spacecraft systems; further technology development should be considered. To that end, recommendations for forward development work have been proposed and provided herein.

Potable Water↗

MISSE 1 and 2 Tray Temperature Measurements

The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.

Harvey, Gale A.↗

The cool-star spectral catalog: A uniform collection of IUE SWP-LOs

Over the past decade and a half of its operations, the International Ultraviolet Explorer has recorded low-dispersion spectrograms in the 1150-2000 A interval of more than 800 stars of late spectral type (F-M). The sub-2000 A region contains a number of emission lines that are key diagnostics of physical conditions in the high-excitation chromospheres and subcoronal 'transition zones' of such stars. Many of the sources have been observed a number of times, and the available collection of SWP-LO exposures in the IUE Archives exceeds 4,000. With support from the Astrophysics Data Program, we have assembled the archival material into a catalog of IUE far-UV fluxes of late-type stars. In order to ensure uniform processing of the spectra, we: (1) photometrically corrected the raw vidicon images with a custom version of the 1985 SWP ITF; (2) identified and eliminated, sharp cosmic-ray 'hits' by means of a spatial filter; (3) extracted the spectral traces with the 'optimal' (weighted-slit) strategy; and (4) calibrated them against a well-characterized reference source, the DA white dwarf G191-B2B. Our approach is similar to that adopted by the IUE Project for its 'Final Archive', but our implementation is specialized to the case of chromospheric emission-line sources. We measured the resulting SWP-LO spectra using a semi-autonomous algorithm that establishes a smooth continuum by numerical filtering, and then fits the significant emissions (or absorptions) by means of a constrained Bevington-type multiple-Gaussian procedure. The algorithm assigns errors to the fitted fluxes - or upper limits in the absence of a significant detection - according to a model based on careful measurements of the noise properties of the IUE's intensified SEC cameras. Here, we describe the 'visualization' strategies we adopted to ensure human-review of the semi-autonomous processing and measuring algorithms; the derivation of the noise model and the assignment of errors; and the structure of the final catalog as delivered to the Astrophysics Data System.

Ayres, T.↗

Doppler Lidar Sensor for Precision Navigation in GPS-Deprived Environment

Landing mission concepts that are being developed for exploration of solar system bodies are increasingly ambitious in their implementations and objectives. Most of these missions require accurate position and velocity data during their descent phase in order to ensure safe, soft landing at the pre-designated sites. Data from the vehicle's Inertial Measurement Unit will not be sufficient due to significant drift error after extended travel time in space. Therefore, an onboard sensor is required to provide the necessary data for landing in the GPS-deprived environment of space. For this reason, NASA Langley Research Center has been developing an advanced Doppler lidar sensor capable of providing accurate and reliable data suitable for operation in the highly constrained environment of space. The Doppler lidar transmits three laser beams in different directions toward the ground. The signal from each beam provides the platform velocity and range to the ground along the laser line-of-sight (LOS). The six LOS measurements are then combined in order to determine the three components of the vehicle velocity vector, and to accurately measure altitude and attitude angles relative to the local ground. These measurements are used by an autonomous Guidance, Navigation, and Control system to accurately navigate the vehicle from a few kilometers above the ground to the designated location and to execute a gentle touchdown. A prototype version of our lidar sensor has been completed for a closed-loop demonstration onboard a rocket-powered terrestrial free-flyer vehicle.

Amzajerdian, F.↗

Applying Motion Constraints Based on Test Data

MSC ADAMS is a simulation software that is used to analyze multibody dynamics. Using user subroutines, it is possible to apply motion constraints to the rigid bodies so that they match the motion profile collected from test data. This presentation describes the process of taking test data and passing it to ADAMS using user subroutines, and uses the Morpheus free-flight 4 test as an example of motion data used for this purpose. Morpheus is the name of a prototype lander vehicle built by NASA that serves as a test bed for various experimental technologies (see backup slides for details) MSC.ADAMS"TM" is used to play back telemetry data (vehicle orientation and position) from each test as the inputs to a 6-DoF general motion constraint (details in backup slides) The MSC.ADAMS"TM" playback simulations allow engineers to examine and analyze flight trajectory as well as observe vehicle motion from any angle and at any playback speed. This facilitates the development of robust and stable control algorithms, increasing reliability and reducing development costs of this developmental engine The simulation also incorporates a 3D model of the artificial hazard field, allowing engineers to visualize and measure performance of the developmental autonomous landing and hazard avoidance technology ADAMS is a multibody dynamics solver. It uses forces, constraints, and mass properties to numerically integrate equations of motion. The ADAMS solver will ask the motion subroutine for position, velocity, and acceleration values at various time steps. Those values must be continuous over the whole time domain. Each degree of freedom in the telemetry data can be examined separately; however, linear interpolation of the telemetry data is invalid, since there will be discontinuities in velocity and acceleration.

Burlone, Michael↗

Maximum Correntropy Kalman Filter for Orientation Estimation with Application to LiDAR Inertial Odometry

Robot navigation is a prerequisite to enable many autonomous robotic operations. Propioceptive inertial measurement units (IMUs) are widely used and commonly accepted sensing devices in robotic navigation. An IMU typically consists of two-triaxis sensors: an accelerometer and a gyroscope (gyro), measuring the accelerations (accelerated motion together with gravity) and angular velocities of the sensor, respectively. In addition, some IMUs incorporate a magnetic angular rate sensor, which is a triaxis magnetometer measuring the magnetic field of the Earth. In this work, we focus on these types of IMUs (comprised of accelerometer, gyro and magnetometer).

Agha-mohammadi, Ali-akbar↗

ChIPPS: Charged Information-storage Polymer Preparation System

Technological advances are required to support principal science objectives of missions to the solar system’s icy worlds to seek biosignatures of past/extant life. Sensitivity and reliability are key concerns due to small sample sizes (µL – mL) and the extraordinary import of the results. The preparation and processing of small samples can constrain limits of detection (LoDs); therefore, the Charged Information-storage Polymer Preparation System (ChIPPS) project is advancing the technologies of autonomous sample preparation and processing to add a new class of reliably detectable biosignatures: charged polymers and particles, which can be the information storage-and-transmission means for life. Specifically, we are developing an integrated microfluidic sample-processing unit to prepare icy-world samples to support complementary solid-state nanopore-based analyses: 1) charged-polymer analysis, to characterize variations in polymer chain size, shape, and charge vs. position along the chain; 2) polymer and nanoparticle sizing-and-counting, to characterize the relative abundance of polymer chains, as well as small (virus-sized) particles, by their dimensions and charge. Although no such autonomous system presently exists, such measurements can reveal the nature and abundance of charged polymers that could be used by biological systems to store and transfer information—as DNA and RNA are used terrestrially—without limitation to terrestrial nucleic acids, given that life elsewhere may utilize different information store-and-transfer moieties. Key system components include (a) a lysis unit for mechanical sample disruption; b) an ion-exchange column for charged macromolecule/nanoparticle purification; c) dialyzer to remove excess salt; d) concentrator to enhance signal; e) supporting pumps, valves, bubble traps, connectors, filters, etc.; f) interface to nanopore detection instruments.

Space Biology↗

Controlled breathing protocols probe human autonomic cardiovascular rhythms

The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

Non-NASA Center↗

INS integrated motion analysis for autonomous vehicle navigation

The use of inertial navigation system (INS) measurements to enhance the quality and robustness of motion analysis techniques used for obstacle detection is discussed with particular reference to autonomous vehicle navigation. The approach to obstacle detection used here employs motion analysis of imagery generated by a passive sensor. Motion analysis of imagery obtained during vehicle travel is used to generate range measurements to points within the field of view of the sensor, which can then be used to provide obstacle detection. Results obtained with an INS integrated motion analysis approach are reviewed.

Roberts, Barry↗

Method for Measuring the Volume-Scattering Function of Water

The volume scattering function (VSF) of seawater affects visibility, remote sensing properties, in-water light propagation, lidar performance, and the like. Currently, it s possible to measure only small forward angles of VSF, or to use cumbersome, large, and non-autonomous systems. This innovation is a method of measuring the full range of VSF using a portable instrument. A single rapid-sensing photosensor is used to scan a green laser beam, which delivers the desired measurement. By using a single sensor, inter-calibration is avoided. A compact design is achieved by using drift-free detector electronics, fiber optics, and a new type of photomultiplier. This provides a high angular resolution of 1 or better, as well as the ability to focus in on a VSF region of particular interest. Currently, the total scattering of light is measured as a difference from the other two parts of the light budget equation. This innovation will allow the direct calculation of the total scattering of light by taking an integral of the VSF over all angles. This directly provides one of the three components of the light budget equation, allowing greater versatility in its calculation.

Agrawal, Yogesh C.↗

Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

Avoidance↗

Autonomous Navigation Using Celestial Objects

In the twenty-first century, National Aeronautics and Space Administration (NASA) Enterprises envision frequent low-cost missions to explore the solar system, observe the universe, and study our planet. Satellite autonomy is a key technology required to reduce satellite operating costs. The Guidance, Navigation, and Control Center (GNCC) at the Goddard Space Flight Center (GSFC) currently sponsors several initiatives associated with the development of advanced spacecraft systems to provide autonomous navigation and control. Autonomous navigation has the potential both to increase spacecraft navigation system performance and to reduce total mission cost. By eliminating the need for routine ground-based orbit determination and special tracking services, autonomous navigation can streamline spacecraft ground systems. Autonomous navigation products can be included in the science telemetry and forwarded directly to the scientific investigators. In addition, autonomous navigation products are available onboard to enable other autonomous capabilities, such as attitude control, maneuver planning and orbit control, and communications signal acquisition. Autonomous navigation is required to support advanced mission concepts such as satellite formation flying. GNCC has successfully developed high-accuracy autonomous navigation systems for near-Earth spacecraft using NASA's space and ground communications systems and the Global Positioning System (GPS). Recently, GNCC has expanded its autonomous navigation initiative to include satellite orbits that are beyond the regime in which use of GPS is possible. Currently, GNCC is assessing the feasibility of using standard spacecraft attitude sensors and communication components to provide autonomous navigation for missions including: libration point, gravity assist, high-Earth, and interplanetary orbits. The concept being evaluated uses a combination of star, Sun, and Earth sensor measurements along with forward-link Doppler measurements from the command link carrier to autonomously estimate the spacecraft's orbit and reference oscillator's frequency. To support autonomous attitude determination and control and maneuver planning and control, the orbit determination accuracy should be on the order of kilometers in position and centimeters per second in velocity. A less accurate solution (one hundred kilometers in position) could be used for acquisition purposes for command and science downloads. This paper provides performance results for both libration point orbiting and high Earth orbiting satellites as a function of sensor measurement accuracy, measurement types, measurement frequency, initial state errors, and dynamic modeling errors.

Folta, David↗

The effects of autogenic-feedback training on motion sickness severity and heart rate variability in astronauts

Space motion sickness (SMS) affects 50 percent of all people during early days of spaceflight. This study describes the results of two Shuttle flight experiments in which autogenic-feedback training (AFT), a physiological conditioning method, was tested as a treatment for this disorder. Of the six who were designated as flight subjects (two women and four men), three were given treatment and three served as controls (i.e., no AFT). Treatment subjects were given 6 hours of preflight AFT. Preflight results showed that AFT produced a significant increase in tolerance to rotating chair motion sickness tests. Further, this increased tolerance was associated with changes in specific physiological responses and reports of reduced malaise. Flight results showed that two of the three control subjects experienced repeated vomiting on the first mission day, while one subject experienced only moderate malaise. Of the three treatment subjects, one experienced mild discomfort, one moderate discomfort, and one severe motion sickness. Only the three control subjects took medication for symptom suppression. Measures of cardiac function reflective of vagal control were shown to be affected especially strongly on the first day of space flight. AFT given for control of heart rate, respiration, and other autonomic activity influenced both the vagal control measures and SMS. These data suggest that AFT may be an effective treatment for space motion sickness; however, this cannot be demonstrated conclusively with the small number of subjects described.

Toscano, William B.↗

Mechanism of blood pressure and R-R variability: insights from ganglion blockade in humans

Spontaneous blood pressure (BP) and R-R variability are used frequently as 'windows' into cardiovascular control mechanisms. However, the origin of these rhythmic fluctuations is not completely understood. In this study, with ganglion blockade, we evaluated the role of autonomic neural activity versus other 'non-neural' factors in the origin of BP and R-R variability in humans. Beat-to-beat BP, R-R interval and respiratory excursions were recorded in ten healthy subjects (aged 30 +/- 6 years) before and after ganglion blockade with trimethaphan. The spectral power of these variables was calculated in the very low (0.0078-0.05 Hz), low (0.05-0.15 Hz) and high (0.15-0.35 Hz) frequency ranges. The relationship between systolic BP and R-R variability was examined by cross-spectral analysis. After blockade, R-R variability was virtually abolished at all frequencies; however, respiration and high frequency BP variability remained unchanged. Very low and low frequency BP variability was reduced substantially by 84 and 69 %, respectively, but still persisted. Transfer function gain between systolic BP and R-R interval variability decreased by 92 and 88 % at low and high frequencies, respectively, while the phase changed from negative to positive values at the high frequencies. These data suggest that under supine resting conditions with spontaneous breathing: (1) R-R variability at all measured frequencies is predominantly controlled by autonomic neural activity; (2) BP variability at high frequencies (> 0.15 Hz) is mediated largely, if not exclusively, by mechanical effects of respiration on intrathoracic pressure and/or cardiac filling; (3) BP variability at very low and low frequencies (< 0.15 Hz) is probably mediated by both sympathetic nerve activity and intrinsic vasomotor rhythmicity; and (4) the dynamic relationship between BP and R-R variability as quantified by transfer function analysis is determined predominantly by autonomic neural activity rather than other, non-neural factors.

Non-NASA Center↗

Sympathetic responses to Valsalva's manoeuvre following bed rest

The purpose of this study was to examine whether 14 days of head-down tilt bed rest (HDBR) alters autonomic regulation during Valsalva's manoeuvre (VM) and if this would predict blood pressure control during a 60 degrees head-up tilt (HUT) test. To examine autonomic control of blood pressure, we measured the changes in systolic (delta SBP) and diastolic (delta DBP) blood pressure between baseline and the early straining (Phase IIE) period of VM (20 sec straining to 40 mmHg; N = 7) in conjunction with changes in muscle sympathetic nerve activity (MSNA; microneurography) burst frequency (B/min) and total activity (% delta) from baseline over the 20-sec straining period. MSNA data were successfully recorded from 6 of the 7 individuals. The averaged responses from three repeated VMs performed in the supine position were compared between the pre- and post-HDBR tests. Compared with the pre-HDBR test, a greater reduction in SBP, DBP, and MAP was observed during Phase IIE following HDBR, p < 0.05. The increase in MSNA burst frequency during straining was augmented in the post- compared with the pre-HDBR test, p < 0.0001, as was the Phase IV blood pressure overshoot, p < 0.05. Although all subjects completed the 20-min pre-HDBR tilt test without evidence of hypotension or orthostatic intolerance, the post-HDBR test was stopped early in 5 of the 7 subjects due to systolic hypotension. The responses during the VM suggest that acute autonomic adjustments to rapid blood pressure changes are preserved after bed rest. Furthermore, MSNA and blood pressure responses during VM did not predict blood pressure control during orthostasis following HDBR.

NASA Discipline Musculoskeletal↗