Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

Abstract In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Varying stopping and self-focusing of intense proton beams as they heat solid density matter

Transport of intense proton beams in solid-density matter is numerically investigated using an implicit hybrid particle-in-cell code. Both collective effects and stopping for individual beam particles are included through the electromagnetic fields solver and stopping power calculations utilizing the varying local target conditions, allowing self-consistent transport studies. Two target heating mechanisms, the beam energy deposition and Ohmic heating driven by the return current, are compared. The dependences of proton beam transport in solid targets on the beam parameters are systematically analyzed, i.e., simulations with various beam intensities, pulse durations, kinetic energies, and energy distributions are compared. The proton beam deposition profile and ultimate target temperature show strong dependence on intensity and pulse duration. A strong magnetic field is generated from a proton beam with high density and tight beam radius, resulting in focusing of the beam and localized heating of the target up to hundreds of eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Surface Treatments on the Outgassing of 3D-Printed 316L Stainless Steel.

Fermi National Accelerator Laboratory (Fermilab) is a world leader in designing and operating particle accelerators for nuclear and particle physics research. These accelerators rely on electric fields to propel particle beams, which are then directed and focused using magnetic fields. To ensure these beams travel without interference, they must move through an ultra-high vacuum environment, typically around 10⁻⁹ torr. Maintaining such a vacuum requires materials with exceptionally low outgassing rates. 316L stainless steel is a common material choice for vacuum systems due to its low outgassing rates, excellent corrosion resistance, non-magnetic properties, and high mechanical strength. When manufactured using traditional methods like machining, extrusion, and casting, the vacuum properties of 316L stainless steel are well understood. However, the behavior of 316L stainless steel produced through additive manufacturing, such as Direct Metal Laser Sintering (DMLS), is not as well documented. This study aims to determine the outgassing rate of 316L stainless steel fabricated using DMLS. The investigation focuses on measuring the outgassing rates of 1.5 2 vacuum reducers and evaluating the effects of surface preparation techniques, such as mechanical polishing and electropolishing, on the outgassing performance. Understanding the outgassing performance of 3D-printed 316L stainless steel could enable Fermilab engineers to adopt this fabrication method for producing complex parts designed for ultra-high vacuum environments. These advancements have the potential to benefit projects, such as the Long-Baseline Neutrino Facility (LBNF) and the Proton Improvement Plan-II (PIP-II), by improving design flexibility and fostering innovation in accelerator development.

Cloud, Jaiden [Central State University]↗

Focused Electron Beam Induced Deposition Synthesis of 3D Photonic and Magnetic Nanoresonators

While many plasmonic phenomena have been realized by using standard nanoscale synthesis in a single 2-dimensional plane, enhanced functionality should be possible by extending into the third dimension. Several nanoscale synthesis approaches have been explored to achieve 3-dimensional (3d) geometries; however, a robust strategy for synthesizing complex 3d plasmonic architectures is lacking. In this study, we utilize a hybrid of direct-write 3d nanoprinting and thin film deposition to fabricate 3d plasmonic structures. Focused electron beam induced deposition (FEBID) is used to deposit nonplasmonic 3d scaffolds, which are subsequently isolated with a conformal SiO 2 layer and coated with a gold layer to create functional 3d plasmonic nanostructures. A variety of rod antennae, split-ring nanoresonators, and ring resonators are synthesized, and low-loss electron energy loss spectroscopy (EELS) is utilized to characterize their full plasmonic spectra with nanoscale resolution. Complementary EELS simulations are performed to interpret the spectra and elucidate the associated electric and magnetic field distributions of the infrared and near optical modes. This work demonstrates the flexibility that FEBID scaffolds offer for the advancement of 3d plasmonic devices and future advanced optical and magnetic metamaterials.

3d printing↗

Steering an intense relativistic electron beam in a linear induction accelerator

The best electron beam transport through a linear induction accelerator (LIA) is achieved when the beam is well centered on the magnetic axis of the focusing solenoids. Since the beam may be injected offset from, or at an angle to, the centerline, dipole magnets are usually provided as a means to steer the beam and center it. Steering may be accomplished by trial and error, but this is very time consuming, especially for accelerators with a low repetition rate for beam position measurements and dipole adjustments. With this in mind, this article presents a steering method requiring a minimal number of measurements and adjustments to position the beam at any desired location, including positioning on the centerline.

47 OTHER INSTRUMENTATION↗

Superconducting Magnet Performance in LCLS-II Cryomodules

New LCLS-II Linear Superconducting Accelerator Cry-omodules are under construction at Fermilab. Installed in-side each SCRF Cryomodule is a superconducting magnet package to focus and steer an electron beam. The magnet package is an iron dominated configuration with conduc-tively cooled racetrack-type quadrupole and dipole coils. For easier installation the magnet can be split in the vertical plane. Initially the magnet was tested in a liquid helium bath, and high precision magnetic field measurements were performed. The first (prototype) Cryomodule with the magnet inside was built and successfully tested at Fermilab test facility. In this paper the magnet package is discussed, the Cryomodule magnet test results and current leads con-duction cooling performance are presented. So far magnets in nine Cryomodules were successfully tested at Fermilab.

Kashikhin, V.↗

Simulation of periodically focused, adiabatic thermal beams

Self-consistent particle-in-cell simulations are performed to verify earlier theoretical predictions of adiabatic thermal beams in a periodic solenoidal magnetic focusing field [K.R. Samokhvalova, J. Zhou and C. Chen, Phys. Plasma 14, 103102 (2007); J. Zhou, K.R. Samokhvalova and C. Chen, Phys. Plasma 15, 023102 (2008)]. In particular, results are obtained for adiabatic thermal beams that do not rotate in the Larmor frame. For such beams, the theoretical predictions of the rms beam envelope, the conservations of the rms thermal emittances, the adiabatic equation of state, and the Debye length are verified in the simulations. Furthermore, the adiabatic thermal beam is found be stable in the parameter regime where the simulations are performed.

43 PARTICLE ACCELERATORS↗

Belle II Detector: status and proposed US contributions

Conference proceedings for the 2012 American Physical Society, Division of Particles and Fields (DPF2012) conference. Paper is on the US contibutions to the Belle II detector upgrade. High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector and upgraded KEKB accelerator. The status of the Belle II detector and proposed role of the US Belle II collaborators are presented in this article. The B factory experiments, Belle at the KEKB collider at KEK and BaBar at the PEP II collider at SLAC, were built to measure the large mixing-induced CP violation in the B0 system predicted by the theory of Kobayashi and Maskawa. The successful confirmation of the prediction led to the Nobel Prize for both theorists. The B factories were built to answer the question Is the CKM description in the Standard Model correct? Most B factory results are in good agreement with the expectations from the Standard Model (SM) and confirm the CKM structure of quark mixing and CP violation, but some measurements show tensions with the SM prediction. The Super B factories will address the question In what way is the Standard Model wrong? Much larger datasets are needed for high-precision measurements to search for significant deviations from the SM which are expected to exist. The SuperKEKB and Belle II detector are being constructed to perform these high precision studies with a dataset 50ab{sup -1}. The SuperKEKB accelerator will operate at an instantaneous luminosity of 8 x 10{sup 35}cm{sup -2}s{sup -1}, a factor of 40 times higher than the luminosity of the KEKB accelerator at the end of the Belle physics program. The increased luminosity will derive primarily from shrinking the beam size at the interaction point (nano beams) utilizing new final focus quadrapole magnets in combination with a factor of 2 increase in beam currents. To counteract the increase in the beam-beam parameter due to the reduced beta functions, the beam emittance must also be reduced; this will be achieved with a new electron source and a new damping ring.

43 PARTICLE ACCELERATORS↗

Ion source and beam guiding studies for an API neutron generator

Recently developed neutron imaging methods require high neutron yields for fast imaging times and small beam widths for good imaging resolution. For ion sources with low current density to be viable for these types of imaging methods, large extraction apertures and beam focusing must be used. We present recent work on the optimization of a Penning-type ion source for neutron generator applications. Two multi-cusp magnet configurations have been tested and are shown to increase the extracted ion current density over operation without multi-cusp magnetic fields. The use of multi-cusp magnetic confinement and gold electrode surfaces have resulted in increased ion current density, up to 2.2 mA/cm{sup 2}. Passive beam focusing using tapered dielectric capillaries has been explored due to its potential for beam compression without the cost and complexity issues associated with active focusing elements. Initial results from first experiments indicate the possibility of beam compression. Further work is required to evaluate the viability of such focusing methods for associated particle imaging (API) systems.

43 PARTICLE ACCELERATORS↗

Numerical study of a bucked-coil system for muon transport and cooling

A Neutrino Factory, which can deliver an intense flux of {approx}10{sup 21} neutrinos per year from a multi-GeV stored muon-beam is seemingly the ideal tool for studying neutrino oscillations and CP-violations for leptons. The front-end of this facility plays a critical role in determining the number of muons that can be accepted by the downstream accelerators. Delivering peak performance requires transporting the muon beams through long sections of a beam channel containing high-gradient rf cavities and strong focusing solenoids. Here, we propose a novel scheme to improve the performance of the cavities, thereby increasing the number of muons within the acceptance of the accelerator chain. The key element of our new scheme is to apply a set of bucked coils along the lattice, thus forcing the external magnetic field to drop substantially within the cavity. We incorporate this idea into a new lattice design for a Neutrino Factory, and detail its performance numerically.

43 PARTICLE ACCELERATORS↗

Transport characteristics of a Glaser magnet for an axisymmetric and non-axisymmetric space charge dominated beam

This paper describes the dynamics of space charge dominated beam through a Glaser magnet which is often used to focus charged particle beams in the low energy section of accelerators and in many other devices. Various beam optical properties of the magnet and emittance evolution that results from the coupling between the two transverse planes are studied. We have derived ten independent first order differential equations for the beam sigma matrix elements assuming the linear space-charge force consistent with the assumption of the canonically transformed KV like distribution. In addition, the feasibility of using a Glaser magnet doublet in a low energy beam injection line to match an initial non-axisymmetric high intensity beam with net angular momentum to an axisymmetric system to suppress effective emittance growth after transition back to an uncoupled system, has also been studied.

43 PARTICLE ACCELERATORS↗

Shielding of the azimuthal magnetic field by the anode plasma in a relativistic self-magnetic-pinch diode

In relativistic electron beam diodes, the self-generated magnetic field causes electron-beam focusing at the center of the anode. Generally, plasma is formed all over the anode surface during and after the process of the beam focusing. In this work, we use visible-light Zeeman-effect spectroscopy for the determination of the magnetic field in the anode plasma in the Sandia 10 MV, 200 kA (RITS-6) electron beam diode. The magnetic field is determined from the Zeeman-dominated shapes of the Al III 4 s –4 p and C IV 3 s –3 p doublet emissions from various radial positions. Near the anode surface, due to the high plasma density, the spectral line-shapes are Stark-dominated, and only an upper limit of the magnetic field can be determined. The line-shape analysis also yields the plasma density. The data yield quantitatively the magnetic-field shielding in the plasma. In conclusion, the magnetic-field distribution in the plasma is compared to the field-diffusion prediction and found to be consistent with the Spitzer resistivity, estimated using the electron temperature and charge-state distribution determined from line intensity ratios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.↗

Scanning systems for particle cancer therapy

A particle beam to treat malignant tissue is delivered to a patient by a gantry. The gantry includes a plurality of small magnets sequentially arranged along a beam tube to transfer the particle beam with strong focusing and a small dispersion function, whereby a beam size is very small, allowing for the small magnet size. Magnets arranged along the beam tube uses combined function magnets where the magnetic field is a combination of a bending dipole field with a focusing or defocusing quadrupole field. A triplet set of combined function magnets defines the beam size at the patient. A scanning system of magnets arranged along the beam tube after the bending system delivers the particle beam in a direction normal to the patient, to minimize healthy skin and tissue exposure to the particle beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Light focusing using epsilon-near-zero metamaterials

We present a strategy of focusing light using epsilon-near-zero metamaterials with embedded dielectric cylinder. The focusing mechanism is analytically investigated, and its accuracy is substantiated by rigorous full-wave simulations. It is found that the focusing intensity is highly depend on the embedded medium and its size, and the magnetic field amplitude of the focused beam itself can reach as high as 98.2 times the incident field. Owing to its versatility, the proposed light focusing system is sure to find applications in fields such as bio-sensing and in nonlinear optics.

36 MATERIALS SCIENCE↗

Commissioning the Super High Momentum Spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) is a new spectrometer installed in Hall C at Jefferson Lab that can detect particles over a range of central momenta from 2-11 GeV/c and scattering angles from 5.5 to 40 degrees. Jefferson Lab delivers a high intensity electron beam with an energy up to 11 GeV to fixed targets in Hall C. The SHMS is a highly precise and essential upgrade for the 12 GeV Jefferson Lab physics program. Its beam line consists of a dipole magnet with a 3-degree horizontal bend, three quadrupole magnets for horizontal and vertical focusing of the beam, and the spectrometer dipole capable of a 4 T central magnetic field and 18.4-degree bend angle. Measurements in Hall C can be taken with the SHMS independently or in coincidence with the existing High Momentum Spectrometer (HMS). The SHMS was installed in the spring of 2017 and commissioned during the fall 2017/winter 2018 using a range of electron beam energies. This talk summarizes the initial results of the optics tuning of the SHMS and the performance during recent experimental running to include initial elastic hydrogen scattering measurements.

Szumila-Vance, Holly↗

Chirality reversal of magnetic solitons in chiral Cr 1/3 TaS 2

Ferromagnetism in two-dimensional (2D) materials provides an ideal platform to study emergent electromagnetic phenomena in low dimensions for future spintronics. In magnetic-element intercalated transition metal dichalcogenides, topologically nontrivial spin textures, such as chiral helimagnetic spin states and chiral soliton lattices, are realized due to the chiral lattice distortions induced by intercalated magnetic ions. Consequently, the magnetic chirality is predictably determined by the sign of antisymmetric exchange interaction (or Dzyaloshinskii–Moriya interaction, DMI) vector that is coupled to the underlying crystal chirality. Here, using cryogenic Lorentz phase microscopy, we directly observed the chirality reversal behavior of the chiral soliton lattices in Cr 1/3 TaS 2 across the structural defects. We show that a partial 1 T stacking in 2H-TaS 2 locally reduces DMI, leading to magnetic chirality reversal with direct atomic resolution imaging. Furthermore, our experimental results show that manipulation of stacking sequence provides a viable way to control the chirality of topologically nontrivial soliton lattices in 2D magnets.

2D materials↗