Evaluation of thermal treatments for nickel- base Inconel 718 alloy in bellows and gimbal applications Final report, Aug. 1965 - May 1967
Effect of heat treatment on Inconel 718 nickel base alloys and on subsequent fabrication processes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effect of heat treatment on Inconel 718 nickel base alloys and on subsequent fabrication processes
Lithium fluoride for earth orbiting, solar dynamic power conversion system
Monograph organizes and presents significant experience and knowledge accumulated by NASA in development and operational programs. It reviews and assesses current design practices and establishes guidance for achieving greater consistency in design, increased reliability in end product, and greater efficiency in design effort.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Tritium operations require specialized equipment for material compatibility, safety, and waste considerations. Non-metallic pump materials (polymer, oil, or grease) on a tritium-wetted surface can absorb tritium and/or undergo isotope exchange between tritium and more common protium, creating tritiated compounds that can result in material property modification via beta-radiolysis, inventory loss, reduced performance and special waste considerations, all of which increase the operating cost for a facility. Vacuum pumps move gas via a pressure differential between volumes of an operation. Several types of all-metal vacuum pumps exist for this application including metal bellows, diaphragm and scroll pumps. A metal bellows pump incorporates only metal components at the wetted surfaces. The common metal bellows pump employed in tritium facilities, the MB601 (Senior Metal Bellows, Sharon, PA, USA) creates a gas-motive force with a vacuum pressure between 30-40 torr. These pumps can efficiently move gas from one process step to another, as long as sub-30 torr pressures are not required. However, for higher vacuum demand, an all-metal scroll pump can be used with the bellows pump serving as a “backing” pump. This configuration typically provides an achievable vacuum of less than 20 mTorr. All-metal scroll pumps are a technology uniquely applicable to tritium gas handling. The industry standard all-metal scroll pump for glovebox-scale tritium operations is the Normetex 15 m 3 /hr, typically referred to as the Normetex 15 (Normetex Pompes, Pont Audemer, France). However, the final Normetex pumps were manufactured in 2012, rendering them no longer available. Eumeca SaRL (formerly Normetex) has developed and is marketing a scroll pump based on the design of the Normetex 15. A US company, AirSquared (Broomfield, Colorado), has developed and is marketing a potential alternative to the Normetex 15. The Gas Transfer Systems group (Q-7) of the Los Alamos National Laboratory (LANL) procured serial number 0001 of the AirSquared All Metal Vacuum Scroll pump model number V16H034A-C01 in 2019. The LANL Hydrogen Processing Laboratory (HPL) has been evaluating the performance of the pump compared to a Normetex pump as a potential replacement in tritium and fusion facilities requiring this type of pump.
A proposed system for storing oxygen in liquid form and dispensing it in gaseous form is based on (1) initial subcooling of the liquid oxygen; (2) containing the liquid oxygen in a flexible vessel; (3) applying a gas spring to the flexible vessel to keep the oxygen compressed above the saturation pressure and, thus, in the liquid state; and (4) using heat leakage into the system for vaporizing the oxygen to be dispensed. In a typical prior system based on these principles, the flexible vessel is a metal bellows housed in a rigid tank, and the gas spring consists of pressurized helium in the tank volume surrounding the bellows. Unfortunately, the welds in the bellows corrugations are subject to fatigue, and, because bellows have large ullage, a correspondingly large fraction of the oxygen content cannot be expelled. In the proposed system, the flexible vessel would be a bladder made of a liquid- crystal polymer (LCP). (LCPs are strong and compatible with liquid oxygen.) In comparison with a metal bellows, a polymeric bladder would have less ullage and would weigh less. In experiments involving fatigue cycling at liquid-nitrogen temperatures, two LCPs were found to be suitable for this application.
Recent wind-tunnel tests at the NASA Langley Research Center National Transonic Facility utilized high-pressure bellows to route air to the model for evaluating aircraft circulation control. The introduction of these bellows within the Sidewall Model Support System significantly impacted the performance of the external sidewall mounted semi-span balance. As a result of this impact on the semi-span balance measurement performance, it became apparent that a new capability needed to be built into the National Transonic Facility s infrastructure to allow for performing pressure tare calibrations on the balance in order to properly characterize its performance under the influence of static bellows pressure tare loads and bellows thermal effects. The objective of this study was to design both mechanical calibration hardware and an experimental calibration design that can be employed at the facility in order to efficiently and precisely perform the necessary loadings in order to characterize the semi-span balance under the influence of multiple calibration factors (balance forces/moments and bellows pressure/temperature). Using statistical design of experiments, an experimental design was developed allowing for strategically characterizing the behavior of the semi-span balance for use in circulation control and propulsion-type flow control testing at the National Transonic Facility.
Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.
Currently the United States relies on a single source, foreign company, Eumeca (formerly Normetex) for the supply of an all metal vacuum scroll pump to process tritium. This “one of a kind”, all metal, vacuum scroll pump utilizes no “wetted”, polymeric materials that degrade prematurely when exposed to tritium. U.S. based vacuum scroll pump suppliers typically utilize a polymer, Teflon®, as a tip seal material at the edge of the scroll impellers for proper pump function. Teflon® is known to degrade within a relatively short time frame (approximately 1 year) when continually exposed to tritium gas. This degradation results in “flaking” of the Teflon® material which results in particulate contamination of the process gas stream. While filtration of the particulate is possible, doing so requires additional maintenance which is costly in a glovebox environment. In addition, filtration can degrade pumping system performance as particulate collects in the filter media over time. To date, all of the well established U.S and European based vacuum scroll pump manufacturers have been uninterested in developing an all metal vacuum scroll pump that does not use a polymeric scroll tip seal. This position is taken as the vacuum scroll pump manufacturers do not see a large enough market to make it profitable for them to develop and market an all metal vacuum scroll pump. In the mid 2000s, one company, Air Squared, Inc., a small Original Equipment Manufacturer (OEM) specializing in design and fabrication of custom scroll vacuum pumps and compressors, was willing to pursue the effort. The first design effort incorporated Vespel® as a polymeric tip seal material. Results of this effort led to realizing the affect that the Met-Bel MB-601 metal bellows pump has on performance when used as a backing pump for an all metal vacuum scroll pump without a scroll tip seal. As a result, Air Squared subsequently designed an all metal vacuum scroll pump without a tip seal material for evaluation. Although the initial, all metal version of the Air Squared pump was found deficient in regard to scroll impeller stiffness, which resulted in scroll contact, general design and pump performance was verified to be adequate. SRS PDRD Project 19039 was launched in 2019 as a 3rd attempt with Air Squared, Inc. in regard to development of an all metal vacuum scroll pump for consideration as an equivalent to the Eumeca/ Normetex pump. The effort specified 300 series stainless steel for the scroll impellers, all metal sealing, and design to meet tritium throughput and ultimate vacuum requirements. In addition, a 60 psig design pressure rating requirement was specified for the pump containment boundary. The 3rd generation Air Squared pump has been designed, fabricated, and has received preliminary testing. Preliminary testing has indicated proper leak tightness and pump performance. However, work continues regarding development of a pumping chamber containment bellows that can be subjected to 66 psig without damage to the bellows. Work will continue in 2020 and 2021 to pursue a pumping chamber containment bellows that meets the pressure rating requirement.
A methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.
An internally supported, flexible duct joint for use in conducting fluids under relatively high pressures in systems where relatively large deflection angles must be accommodated is presented. The joint includes a flexible tubular bellows and an elongated base disposed within the bellows. The base is connected through radiating struts to the bellows near mid-portion and to each of the opposite end portions of the bellows through a pivotal connecting body. A motion-controlling linkage is provided for linking the connecting bodies, whereby angular displacement of the joint is controlled and uniformity in the instantaneous bend radius of the duct is achieved as deflection is imposed.
Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.
A pneumatically actuated solar panel array system that includes a plurality of separate actuator assemblies that each have a top plate and bottom plate and a first and second bellows that each extend between and are coupled to the top and bottom plates at a respective top head and bottom head, the first and second bellows being configured to be separately pneumatically inflated, where the pneumatic inflation expands the bellows along a length. The pneumatically actuated solar panel array system can also include a plurality of solar panels coupled to the actuator assemblies with the solar panels being configured to be actuated based on inflation of one or more bellows associated with the plurality of actuator assembles.
An actuator that includes a bottom plate, a top-plate, and a first and second hub assembly extending between the bottom and top plates. The actuator can further include a first and second bellows disposed on opposing sides of the hub assemblies, the first and second bellows each extending between and coupled to the top plate and bottom plate. The actuator can also include a plurality of washers disposed between the top and bottom plates, with each of the washers coupled to the first and second hub assembly, a first set of the plurality of washers surrounding the first bellows and a second set of the plurality of washers surrounding the second bellows.
A system for controlling a rotation of one or more solar panels about an axis of rotation, comprising one or more solar panels defining a longitudinal axis, one or more bellows actuators coupled to the one or more solar panels and defining an axis of rotation parallel to the longitudinal axis of the panels, a fluid source, a first valve circuit coupled to the bellows actuators and the fluid source, a second valve circuit coupled to the bellows actuators and the fluid source, and a controller, wherein introduction or release of fluid from one or more of the bellows actuators is configured to cause rotation of the one or more actuators about the axis of rotation.
Filter senses increasing pressure drop and uses this to compress bellows. Compression of bellows stores energy in spring until predetermined pressure-drop level is reached. At this point, bellows and spring are released. Relaxation of spring is used to move a clean area of screen into position across fluid stream.