Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Transport”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗

NASA Space Radiation Program Integrative Risk Model Toolkit

NASA Space Radiation Program Element scientists have been actively involved in development of an integrative risk models toolkit that includes models for acute radiation risk and organ dose projection (ARRBOD), NASA space radiation cancer risk projection (NSCR), hemocyte dose estimation (HemoDose), GCR event-based risk model code (GERMcode), and relativistic ion tracks (RITRACKS), NASA radiation track image (NASARTI), and the On-Line Tool for the Assessment of Radiation in Space (OLTARIS). This session will introduce the components of the risk toolkit with opportunity for hands on demonstrations. The brief descriptions of each tools are: ARRBOD for Organ dose projection and acute radiation risk calculation from exposure to solar particle event; NSCR for Projection of cancer risk from exposure to space radiation; HemoDose for retrospective dose estimation by using multi-type blood cell counts; GERMcode for basic physical and biophysical properties for an ion beam, and biophysical and radiobiological properties for a beam transport to the target in the NASA Space Radiation Laboratory beam line; RITRACKS for simulation of heavy ion and delta-ray track structure, radiation chemistry, DNA structure and DNA damage at the molecular scale; NASARTI for modeling of the effects of space radiation on human cells and tissue by incorporating a physical model of tracks, cell nucleus, and DNA damage foci with image segmentation for the automated count; and OLTARIS, an integrated tool set utilizing HZETRN (High Charge and Energy Transport) intended to help scientists and engineers study the effects of space radiation on shielding materials, electronics, and biological systems.

Kim, Myung-Hee Y.↗

Beam Performance of the Positron Transport Line for CEBAF Positron Upgrade

The Low Energy Recirculator Facility (LERF) at Jefferson Lab, formerly operated for the Free-Electron Laser program, has been proposed as the injector complex for the planned 12 GeV CEBAF positron upgrade (Ce+BAF), with an additional pathway to support a potential 22 GeV CEBAF electron upgrade. In this configuration, LERF would generate and pre-accelerate positrons to 123 MeV, matching the present injection energy into the North Linac. Due to the relatively large emittance expected from the positron source, a comprehensive acceptance study has been performed from LERF through the CEBAF recirculating linacs and beam transport lines to the experimental halls. The objective is to establish the positron phase-space acceptance and provide design feedback to the positron production and capture systems. Furthermore, given CEBAF’s capability to deliver highly polarized beams, spin-tracking simulations have been carried out including magnet imperfections, alignment errors, and synchrotron-radiation–induced energy spread. Particular attention is given to the evolution of the spin tune and the corresponding depolarization mechanisms along the beam delivery path, especially for providing longitudinal polarization at the experimental halls. These results inform injector design choices and assess the overall feasibility of delivering high-polarization positron beams in CEBAF.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Steering an intense relativistic electron beam in a linear induction accelerator

The best electron beam transport through a linear induction accelerator (LIA) is achieved when the beam is well centered on the magnetic axis of the focusing solenoids. Since the beam may be injected offset from, or at an angle to, the centerline, dipole magnets are usually provided as a means to steer the beam and center it. Steering may be accomplished by trial and error, but this is very time consuming, especially for accelerators with a low repetition rate for beam position measurements and dipole adjustments. With this in mind, this article presents a steering method requiring a minimal number of measurements and adjustments to position the beam at any desired location, including positioning on the centerline.

47 OTHER INSTRUMENTATION↗

Development of Design for the STS Extraction Magnet System

The Oak Ridge National Laboratory STS Project will enhance the Spallation Neutron Source by adding a new neutron source. The upgrade includes a 30% increase in beam energy and a 50% boost in beam current, doubling the accelerator's power capability to 2.8 MW. The Ring-to-Second-Target Beam Transport (RTST) system is vital in directing high-energy proton beams to the new second target station. New magnets have to fit into a restricted space within the existing beamline to add the new extraction line. New, fast kicker magnets (Pulsed Dipole), a focusing quad with an aperture for both beamlines (Large Quad) and the replacement of existing 21Q40 Quads with 'Narrow Quads' having identical fields as the existing design are Fermilab's responsibility. The design of these magnets poses unique challenges, as in addition to the high requirements on the quality of magnetic fields, they are subject to major restrictions related to their dimensions.

Chernenok, V. [Fermilab] (ORCID:0009000778148215)↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

Degraded beam study of CEBAF

An electron beam degrader has been installed in the CEBAF injector in support of the positron capabilities of the machine, enabling machine acceptance measurements and testing of large emittance beam transport. This update provides the current state of the project, including proposed beam tests and preliminary results from simulations and previous beam studies.

Lizarraga-Rubio, Victor [Universidad de Guanajuato↗

Bayesian Optimization of a Free-Electron Laser

The Linac Coherent Light Source X-ray free-electron laser is a complex scienti c apparatus which changes con gurations multiple times per day, necessitating fast tuning strategies to reduce setup time for successive experiments. To this end, we employ a Bayesian approach to maximizing X- ray laser pulse energy by controlling groups of quadrupole magnets. A Gaussian process model provides probabilistic predictions for the machine response with respect to control parameters, enabling a balance of exploration and exploitation in the search for the global optimum. We show that the model parameters can be learned from archived scans, and correlations between devices can be extracted from the beam transport. Furthermore, the result is a sample-e cient optimization routine, combining both historical data and knowledge of accelerator physics to signi cantly outperform existing optimizers.

47 OTHER INSTRUMENTATION↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonperturbative methods in HZE ion transport

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport. The code is established to operate on the Langley Research Center nuclear fragmentation model used in engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurements. The code is highly efficient and compares well with the perturbation approximations.

Wilson, John W.↗

Approximate Green's function methods for HZE transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multilayered materials. The code is established to operate on the Langley nuclear fragmentation model used in engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurements. The code was found to be highly efficient and compared well with the perturbation approximation.

Wilson, John W.↗

Particle-In-Cell Computer Simulations of Beam Spill in the Scorpius Injector

Computer simulations of beam transport in the Scorpius injector were performed using the particle-in-cell computer code LSP. The simulations were used to predict spot size growth due to electron stimulated emission of ions from beam spill on the anode stalk and the entrance transport region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation study of high-current 7 Li 3+ beam acceleration with laser ion source and RFQ linac using direct plasma injection

Accelerator-based neutron sources (ABNS) utilizing the 7 Li(p,n) 7 Be reaction in inverse kinematics offer strong forward-directed neutron emission, making them attractive for compact and clean neutron source with low background neutrons and unwanted radiation. However, practical use of such systems requires lithium ion beam currents that exceed the capability of conventional ion accelerators by two orders of magnitude. In this study, we numerically designed and evaluated a high-current acceleration system based on a direct plasma injection scheme (DPIS), combining a laser ion source (LIS) and a radio-frequency quadrupole (RFQ) linac. The ion extraction optics and RFQ entrance were optimized using IGUN, OPERA, and GPT, demonstrating that over 1.2 A-class beam current can be injected into the RFQ. The RFQ structure was designed under realistic engineering constraints including surface field strength (Kilpatrick factor) and RF power. GPT simulations showed that a 370 mA 7 Li 3+ beam can be successfully accelerated within a ±10 % energy spread. To validate downstream compatibility, we also designed a simplified medium-energy beam transport (MEBT) section and an interdigital H-type (IH) linac, confirming successful acceleration of a 320 mA beam to the total energy of 14 MeV. These results support the feasibility of the DPIS and RFQ approach as a promising solution for compact neutron sources and other high-intensity ion beam applications.

43 PARTICLE ACCELERATORS↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Beam study on low dispersion CEBAF arcs

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab employs recirculating linac SRF technology to generate a high polarization 12 GeV electron beam for nuclear physics users. New opportunities to study multipass energy recovery have also emerged with the proposal of a 5-pass energy recovery demonstration, ER@CEBAF. New beam optics with minimized beta functions have been developed and tested to avoid collective beam instabilities for multi-pass beams and meet the beam requirements of the nuclear physics community. To enable energy recovery for a common arc beam transport of five passes, achromatic and isochronous arc optics conditions were satisfied by re-designing the transverse optics of CEBAF. This paper focuses on beam studies conducted to study the newly-designed, low-dispersion, lowest energy arcs for CEBAF operations and ER@CEBAF.

Neththikumara, I.↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗