Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Strain and Temperature Sensing Properties of Multiwalled Carbon Nanotube Yarn Composites

Strain and temperature response of Multiwalled Carbon Nanotube (MWCNT/CNT) yarns on a stainless steel test beam has been studied. The carbon nanotube yarns are spun from a multiwalled carbon nanotube forest grown on a silicon substrate to a 4-ply yarn with a diameter of about 15-20 microns. Four of the 4-ply CNT yarns are arranged in a Wheatstone bridge configuration on the stainless steel test beam using a thin layer of polyurethane resin that insulates and protects the yarns from the test beam. Strain sensitivities of the CNT yarn sensors range from 1.39 to 1.75 mV/V/1000 microstrain at room temperature, and temperature sensitivity of the CNT yarn bridge is 91 microA/degC. Resistance of the yarns range from 215 to 270 ohms for CNT yarn length of approximately 5 mm. Processes used in attaching the CNT yarns on the test beam and experimental procedures used for the measurements are described. Conventional metallic foil strain gages are attached to the test beam to compare with the CNT sensors. The study demonstrates multifunctional capability of the sensor for strain and temperature measurements and shows its applicability where engineering strain is less than 3%.

Kahng, Seun K.↗

Proof-mass actuator placement strategies for regulation of flexure during the SCOLE slew

An analysis was performed in order to find the best placement for proof-mass actuators and to determine the importance of placement, i.e., what is the sensitivity of beam flexure to actuator placement. The analysis was performed by using the NASTRAN finite element model for a flexible beam with 21 grid points on beam, by using the nonlinear DISCOS simulation of 20 deg slew and the use of a closed-loop linear quadratic regulator (lqr). Some conclusions reached are: (1) proof-mass actuators can reduce flexure amplitude and damp oscillations; (2) amplitude of deformations during slew is relatively insensitive to placement of actuators; (3) damping factor of oscillations is sensitive to actuator placement; and (4) the degree of controllability method indicates most effective placement for actuators.

Fisher, Shalom (mike)↗

Computational aspects of sensitivity calculations in transient structural analysis

A key step in the application of formal automated design techniques to structures under transient loading is the calculation of sensitivities of response quantities to the design parameters. This paper considers structures with general forms of damping acted on by general transient loading and addresses issues of computational errors and computational efficiency. The equations of motion are reduced using the traditional basis of vibration modes and then integrated using a highly accurate, explicit integration technique. A critical point constraint formulation is used to place constraints on the magnitude of each response quantity as a function of time. Three different techniques for calculating sensitivities of the critical point constraints are presented. The first two are based on the straightforward application of the forward and central difference operators, respectively. The third is based on explicit differentiation of the equations of motion. Condition errors, finite difference truncation errors, and modal convergence errors for the three techniques are compared by applying them to a simple five-span-beam problem. Sensitivity results are presented for two different transient loading conditions and for both damped and undamped cases.

Greene, William H.↗

Computational aspects of sensitivity calculations in transient structural analysis

A key step in the application of formal automated design techniques to structures under transient loading is the calculation of sensitivities of response quantities to the design parameters. This paper considers response quantities to the design parameters. This paper considers structures with general forms of damping acted on by general transient loading and addresses issues of computational errors and computational efficiency. The equations of motion are reduced using the traditional basis of vibration modes and then integrated using a highly accurate, explicit integration technique. A critical point constraint formulation is used to place constraints on the magnitude of each response quantity as a function of time. Three different techniques for calculating sensitivities of the critical point constraints are presented. The first two are based on the straightforward application of the forward and central difference operators, respectively. The third is based on explicit differentiation of the equations of motion. Condition errors, finite difference truncation errors, and modal convergence errors for the three techniques are compared by applying them to a simple five-span-beam problem. Sensitivity results are presented for two different transient loading conditions and for both damped and undamped cases.

Greene, William H.↗

Sensitivity analysis of the optimal solution obtained from the structural damage indentification process

An identification procedure proposed by Shen and Taylor to determine the crack characteristics (location and size of the crack) from dynamic measurements is tested. This procedure was based on minimization of either the 'mean-square' measure of difference between measurement data (natural frequencies and mode shapes) and the corresponding predictions obtained from the computational model. The procedure is tested for simulated damage in the form of symmetric cracks in a simply-supported Bernoulli-Euler beam. The sensitivity of the solution of damage identification problems to the values of parameters that characterize damage is discussed. A sensitivity formula is derived.

Shen, Mo-How H.↗

Beam Energy Dependence of the Linear and Mode-Coupled Flow Harmonics Using the a Multi-Phase Transport Model

In the framework of the A Multi-Phase Transport (AMPT) model, the multi-particle azimuthal cumulant method is used to calculate the linear and mode-coupled contributions to the quadrangular flow harmonic (v4) and the mode-coupled response coefficient as functions of centrality in Au+Au collisions at sNN = 200, 39, 27 and 19.6 GeV. This study indicates that the linear and mode-coupled contributions to v4 are sensitive to beam energy change. Nevertheless, the correlations between different-order flow symmetry planes and the mode-coupled response coefficients show weak beam energy dependence. In addition, the presented results suggest that the experimental measurements that span a broad range of beam energies can be an additional constraint for the theoretical model calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Atomically resolved edges and defects in lead halide perovskites

Although edges and defects constitute only a small fraction of crystalline materials, they exert an outsized impact on a material′s properties. Organic–inorganic halide perovskites are promising next-generation semiconductor materials with superior cost effectiveness and interesting optoelectronic properties. However, clear images of their edges have remained challenging to obtain owing to their extreme sensitivity. Using truly high-speed ultralow-dose four-dimensional scanning transmission electron microscopy with dose fractionation, we perform ptychography at, to our knowledge, the lowest-dose atomic resolution to date, revealing not only the detailed atomic structure of the edges of a halide perovskite but also their structural dynamics. Here, a majority methylammonium (MA) and iodine (I) edge termination is observed in methylammonium lead iodide (MAPbI 3 ), and the damage rate of its edges and internal defects is found to depend on the concentration and type of vacancies present, with a preponderance of I vacancies in particular correlating with higher rates of damage.

4D-STEM↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Linear and circular polarization of the cosmic background radiation

New data which consist of continued measurements of the linear polarization of the cosmic background radiation as well as the first measurement of the circular polarization are examined. Eleven declinations have been surveyed for linear polarization and one declination for circular polarization, all at 9 mm wavelength. No evidence is found for either a significant linear or circular component with statistical errors on the linear component of 20-60 microK for various models. For linear polarization, a 95 percent confidence level limit of 0.1 mK (0.00003) for an axisymmetric anisotropic model is achieved, while for spherical harmonics through third order, a corresponding limit of 0.2 mK is achieved. For a declination of 37 deg, a limit of 12 mK is placed on the time-varying component and 20 mK on the dc component of the circular polarization at the 95 percent confidence level. At 37 percent declination, the sensitivity per beam patch (7 deg) is 0.2 mK.

Lubin, P.↗

Far Infrared All-Sky Survey

Precise measurements of the angular power spectrum of the Cosmic Microwave Background (CMB) anisotropy will revolutionize cosmology. These measurements will discriminate between competing cosmological models and, if the standard inflationary scenario is correct, will determine each of the fundamental cosmological parameters with high precision. The astrophysics community has recognized this potential: the orbital experiments MAP and PLANCK, have been approved to measure CMB anisotropy. Balloon-borne experiments can realize much of this potential before these missions are launched. Additionally, properly designed balloon-borne experiments can complement MAP in frequency and angular resolution and can give the first realistic test of the instrumentation proposed for the high frequency instrument on PLANCK. The MAXIMA experiment is part of the MAXIMA/BOOMERANG collaboration which is doing balloon observations of the angular power spectrum of the Cosmic Microwave Background from l = 10 to l = 800. These experiments are designed to use the benefits of both North American and Antarctic long-duration ballooning to full advantage. We have developed several new technologies that together allow the power spectrum to be measured with unprecedented combination of angular resolution, beam throw, sensitivity, sky coverage and control of systematic effects. These technologies are the basis for the high frequency instrument for the PLANCK mission. Our measurements will strongly discriminate between models of the origin and evolution of structure in the universe and, for many models, will determine the value of the basic cosmological parameters to high precision.

Richards, Paul L.↗

Ion beam profiling system and related methods

An ion beam profiling system include a beam profiling element, an ion sensitive element electrically isolated from the beam profiling element, an ion source configured to emit an ion beam at the beam profiling element and the ion sensitive element, and a current measuring device coupled to the ion sensitive element. The beam profiling element includes a plate of material having two parallel major surfaces, a first slit aperture extending through the plate of material and having a first longitudinal length extending in a direction parallel to the two parallel major surfaces, and a second slit aperture extending through the plate of material and having a second longitudinal length extending in a direction parallel to the two parallel major surfaces, wherein the first longitudinal length of the first slit aperture is perpendicular to the second longitudinal length of the second slit aperture.

Taylor, Chase N.↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Sensitivity analysis of a deployable three longeron truss beam designed for minimum member loads during deployment

The significant design variables of a deployable three longeron truss beam, designed for minimum member loads during deployment, are identified and the sensitivity of the load level in the members of the truss beam due to variations of the design variables is established. The analysis of the deployment models, developed in this paper, is carried out using a commercially available computer code, called DADS. Based on the results of the analysis, guidelines are formulated for the design of a deployable three longeron truss beam to achieve minimum loads in the members during deployment. The paper concludes with a brief discussion of the applicability of the approach, taken in this paper, to other truss configurations.

Warnaar, Dirk B.↗

Cross-beam energy transfer in direct-drive ICF. I. Nonlinear and kinetic effects

Results are presented from a series of simulations examining the susceptibility of the cross-beam energy transfer (CBET) instability to nonlinear processes in the context of direct-drive inertial confinement fusion experiments on the OMEGA laser facility. These form the basis for the second paper of this series [A. G. Seaton, L. Yin, R. Follett, B. J. Albright, and A. Le, “Cross-beam energy transfer in direct-drive ICF. II. Theory and simulation of mitigation through increased laser bandwidth,” Phys. Plasmas 29, 042707 (2022)], where we examine the efficacy of increases in laser bandwidth at suppressing CBET. We choose laser and plasma conditions for the simulations that are favorable to CBET and promote nonlinearity. Through a comparison of outputs from the particle-in-cell code vector particle in cell (VPIC) and the linearized fluid code laser-plasma simulation environment (LPSE), a series of nonlinear effects have been identified in the kinetic simulations that include particle trapping, the two-ion wave decay, and ion-acoustic wave self-focusing. These effects produce time-dependent energy transfer, in contrast to the linearized fluid simulations in which a steady state is reached after an initial transient. Ion trapping is shown to allow for increased energy transfer relative to fluid simulations, with the remaining nonlinear processes acting to reduce the energy transfer. Nonlinear dynamics is contrasted for low- and high-intensity beams as well as between speckled and planar beams. For the parameters under consideration, beam profile has a significant effect on nonlinear dynamics, though the greatest sensitivity is to beam intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗