Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Trace Element Abundances of Olivine-Hosted Melt Inclusions in Shergottites Northwest Africa 7397 and Robert Massif 04262

Olivine-hosted melt inclusions (MIs) may retain trapped parent magma compositions as well as record progressive differentiation while magmas crystallize and ascend towards the surface [1,2 and references therein]. Major element compositions of the MIs, especially Fe and Mg, can be affected by post-entrapment re-equilibration with their host olivine [1,2]. Therefore, Fe/Mg ratio correction is required to obtain MI bulk compositions following equilibrium with their host olivine. Partition coefficients of most of the trace elements in olivine are very low (i.e. DOL/melt<0.001). Thus, ratios of trace elements of olivine-hosted MIs are unlikely to be affected by post-entrapment re-equilibration and no correction is necessary [2]. Hence, tracking trace element behavior in MIs may constrain the composition of the parent magma and its evolution yielding insights on magma differentiation of shergottites. However, analyzing MIs for chemical compositions is a challenging task due to their low abundances and small sizes. Using a highly sensitive and precise micro-beam technique is essential to examine olivine-hosted MIs in order to measure trace element abundances. For this purpose, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an excellent tool due to its wide range of laser spot sizes (1-150 μm), ability to obtain raster analysis (several mm2) and lower detection limits (0.1 ppb) [3].

Ferdous, J.↗

Application of High-Temperature Extrinsic Fabry-Perot Interferometer Strain Sensor

In this presentation to the NASA Aeronautics Sensor Working Group the application of a strain sensor is outlined. The high-temperature extrinsic Fabry-Perot interferometer (EFPI) strain sensor was developed due to a need for robust strain sensors that operate accurately and reliably beyond 1800 F. Specifically, the new strain sensor would provide data for validating finite element models and thermal-structural analyses. Sensor attachment techniques were also developed to improve methods of handling and protecting the fragile sensors during the harsh installation process. It was determined that thermal sprayed attachments are preferable even though cements are simpler to apply as cements are more prone to bond failure and are often corrosive. Previous thermal/mechanical cantilever beam testing of EFPI yielded very little change to 1200 F, with excellent correlation with SG to 550 F. Current combined thermal/mechanical loading for sensitivity testing is accomplished by a furnace/cantilever beam loading system. Dilatometer testing has can also be used in sensor characterization to evaluate bond integrity, evaluate sensitivity and accuracy and to evaluate sensor-to-sensor scatter, repeatability, hysteresis and drift. Future fiber optic testing will examine single-mode silica EFPIs in a combined thermal/mechanical load fixture on C-C and C-SiC substrates, develop a multi-mode Sapphire strain-sensor, test and evaluate high-temperature fiber Bragg Gratings for use as strain and temperature sensors and attach and evaluate a high-temperature heat flux gauge.

Piazza, Anthony↗

Development of a mass spectrometer system for the measurement of inert gases in meteorites

The study of the inert gases in meteorites has provided many clues as to the origin and evolution of the solar system. Particularly crucial and complex are the gases krypton and xenon. To accurately measure the isotopic compositions of these gases requires a mass spectrometer of high sensitivity and resolution. A previously unused and largely untested mass spectrometer system was brought to the point where it was ready for routine sample analyses. This involved, among other things, focusing the ion beam for optimal peak shape and sensitivity, documenting the instrument's response to a series of characteristic tests such as multplier gain checks, and interfacing the instrument to a computer to run the sample analyses. Following this testing and setting up, three iron meteorite samples were to be analyzed for argon, krypton, and xenon. The three samples were shown in prior work to possibly contain primordial heavy inert gases. Although these analyses have not yet been carried out, it is anticipated that they will be completed in the near future.

Palma, R. L.↗

Measurement of the polarization effects of an instrument using partially polarized light

Accuracy of a radiometer is adversely affected by scene polarization if the receiving optical system is sensitive to polarization. It is therefore necessary to specify and measure the sensitivity of the system to polarized light. The Mueller-Stokes matrix of an instrument may be determined experimentally and used to predict the effects of the instrument on any beam. The specification of a maximum polarization sensitivity stated in terms of the degree of polarization produced in an unpolarized beam can be experimentally verified even though an unpolarized beam is not available in the laboratory for direct measurement.

Howell, B. J.↗

Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices

Spaceflight system electronic devices must survive a wide range of radiation environments with various particle types including energetic protons, electrons, gamma rays, x-rays, and heavy ions. High-energy charged particles such as heavy ions can pass straight through a semiconductor material and interact with a charge-sensitive region, generating a significant amount of charge (electron-hole pairs) along their tracks. These excess charges can damage the device, and the response can range from temporary perturbations to permanent changes in the state or performance. These phenomena are called single event effects (SEE). Before application in flight systems, electronic parts need to be qualified and tested for performance and radiation sensitivity. Typically, their susceptibility to SEE is tested by exposure to an ion beam from a particle accelerator. At such facilities, the device under test (DUT) is irradiated with large beams so there is no fine resolution to investigate particular regions of sensitivity on the parts. While it is the most reliable approach for radiation qualification, these evaluations are time consuming and costly. There is always a need for new cost-efficient strategies to complement accelerator testing: pulsed lasers provide such a solution. Pulsed laser light can be utilized to simulate heavy ion effects with the advantage of being able to localize the sensitive region of an integrated circuit. Generally, a focused laser beam of approximately picosecond pulse duration is used to generate carrier density in the semiconductor device. During irradiation, the laser pulse is absorbed by the electronic medium with a wavelength selected accordingly by the user, and the laser energy can ionize and simulate SEE as would occur in space. With a tightly focused near infrared (NIR) laser beam, the beam waist of about a micrometer can be achieved, and additional scanning techniques are able to yield submicron resolution. This feature allows mapping of all of the sensitive regions of the studied device with fine resolution, unlike heavy ion experiments. The problematic regions can be precisely identified, and it provides a considerable amount of information about the circuit. In addition, the system allows flexibility for testing the device in different configurations in situ.

Aveline, David C.↗

Diffraction-Based Optical Switch

Method and system for controllably redirecting a light beam, having a central wavelength lambda, from a first light-receiving site to a second light-receiving site. A diffraction grating is attached to or part of a piezoelectric substrate, which is connected to one or two controllable voltage difference sources. When a substrate voltage difference is changed and the diffraction grating length in each of one or two directions is thereby changed, at least one of the diffraction angle, the diffraction order and the central wavelength is controllably changed. A diffracted light beam component, having a given wavelength, diffraction angle and diffraction order, that is initially received at a first light receiving site (e.g., a detector or optical fiber) is thereby controllably shifted or altered and can be received at a second light receiving site. A polynomially stepped, chirped grating is used in one embodiment. In another embodiment, an incident light beam, having at least one of first and second wavelengths, lambda1 and lambda2, is received and diffracted at a first diffraction grating to provide a first diffracted beam. The first diffracted beam is received and diffracted at a second diffraction grating to produce a second diffracted beam. The second diffracted beam is received at a light-sensitive transducer, having at least first and second spaced apart light detector elements that are positioned so that, when the incident light beam has wavelength lambda1 or lambda2 (lambda1 not equal to lambda2), the second diffracted beam is received at the first element or at the second element, respectively; change in a selected physical parameter at the second grating can also be sensed or measured. A sequence of spaced apart light detector elements can be positioned along a linear or curvilinear segment with equal or unequal spacing.

Stevan M Sperno↗

Sensitivity Testing of the NSTAR Ion Thruster

During the Extended Life Test of the DS1 flight spare ion thruster, the engine was subjected to sensitvity testing in order to characterize the macroscopic dependence of discharge chamber sensitivity to a +\-3% vatiation in main flow, cathode flow and beam current, and to +\5% variation in beam and accelerator voltage, was determined for the minimum- (THO), half- (TH8) and full power (TH15) throttle levels. For each power level investigared, 16 high/low operating conditions were chosen to vary the flows, beam current, and grid voltages in in a matrix that mapped out the entire parameter space. The matrix of data generated was used to determine the partial derivative or senitivity of the dependent parameters--discharge voltage, discharge current, discharge loss, double-to-single-ion current ratio, and neutralizer-keeper voltage--to the variation in the independent parameters--main flow, cathode flow, beam current, and beam voltage. The sensititivities of each dependent parameter with respect to each independent parameter were determined using a least-square fit routine. Variation in these sensitivities with thruster runtime was recorded over the duration of the ELT, to detemine if discharge performance changed with thruster wear. Several key findings have been ascertained from the sensitivity testing. Discharge operation is most sensitve to changes in cathode flow and to a lesser degree main flow. The data also confirms that for the NSTAR configuration plasma production is limited by primary electron input due to the fixed neutral population. Key sensitivities along with their change with thruster wear (operating time) will be presented. In addition double ion content measurements with an ExB probe will also be presented to illustrate beam ion production and content sensitivity to the discharge chamber operating parameteres.

electric propulsion↗

Improved Plate and Beam Models for Thermoviscoelastic Constitutive Modeling of Composites

The effective properties of composites are influenced by the time-dependent behavior of polymer matrices very sensitive to changes in temperature. Improved plate and beam models are required to efficiently design, and simulate composite structures when the long-term performance of large anisotropic composite structures is the matter of interest. In this work, mechanics of structure genome (MSG) is used to con-struct linear thermoviscoelastic plate and beam models that can homogenize three-dimensional heterogeneous materials made of constituents with time- and temperature-dependent behavior. The formulation derives the transient strain energy based on integral formulation for thermorheologically simple materials subject to finite temperature changes with the restriction that the strain is small. The reduced time parameter is introduced to relate the time-temperature dependency of the anisotropic material by means of master curves at reference conditions. The new formulation has been implemented in SwiftCompTM, a general-purpose multiscale constitutive modeling code based on MSG. Experimental data and three-dimensional direct numerical simulations of thin-ply high-strain composites (TP-HSC) using a commercial finite element analysis (FEA) package are conducted to verify the accuracy of SwiftCompTM results. The paper also analyzes the relationship between the shift factor of the polymer matrix and the temperature dependencies of the effective beam properties.

Finite element analysis↗

Quantum Limits in Interferometric GW Antennas

We discuss a model for interferometric GW antennas illuminated by a laser beam and a vacuum squeezed field. The sensitivity of the antenna will depend on the properties of the radiation entering the two ports and on the optical characteristics of the interferometer components, e.g. mirrors, beam-splitter, lenses.

Romano, R.↗

Ultrasonic Phased-Array Characterization for NDE Applications

Southwest Research Institute (SwRI) recently fabricated and delivered the 100-channel Ultrasonic Phased-Array Testbed System (UPATS) for NASA's Langley Research Center. NASA prepared the specifications and provided the funding to develop UPATS in order to provide a tool for the improvement of ultrasonic nondestructive evaluation (NDE) and characterization of materials. UPATS incorporates state-of-the-art phased-array concepts such as beam steering, focusing, apodization, and phase-sensitive detection which make it possible to develop more sophisticated testing methodologies. It also can be used to investigate fundamental ultrasonic propagation and detection phenomena such as refraction, diffraction, scattering, and beam broadening.

Hanley, John J.↗

Instrumentation for Sensitive Gas Measurements

An improved instrument for optical absorption spectroscopy utilizes off-axis paths in an optical cavity in order to increase detection sensitivity while suppressing resonance effects. The instrument is well suited for use in either cavity ring-down spectroscopy (CRDS) [in which one pulses an incident light beam and measures the rate of decay of light in the cavity] or integrated cavity output spectroscopy (ICOS) [in which one uses a continuous-wave incident light beam and measures the power of light in the cavity as a function of wavelength]. Typically, in optical absorption spectroscopy, one seeks to measure absorption of a beam of light in a substance (usually a gas or liquid) in a sample cell. In CRDS or ICOS, the sample cell is placed in (or consists of) an optical cavity, so that one can utilize multiple reflections of the beam to increase the effective optical path length through the absorbing substance and thereby increase the sensitivity for measuring absorption. If an absorbing substance is not present in the optical cavity, one can utilize the multiple passes of the light beam to increase the sensitivity for measuring absorption and scattering by components of the optical cavity itself. It is desirable to suppress the effects of resonances in the cavity in order to make the spectral response of the cavity itself as nearly constant as possible over the entire wavelength range of interest. In the present instrument, the desired flattening of the spectral response is accomplished by utilizing an off-axis beam geometry to effectively decrease the frequency interval between longitudinal electromagnetic modes of the cavity, such that the resulting transmission spectrum of the cavity is nearly continuous: in other words, the cavity becomes a broad-band optical device.

OKeefe, Anthony↗

P-polarized reflectance spectroscopy: A high sensitive real-time monitoring technique to study surface kinetics under steady state epitaxial deposition conditions

This paper describes the results of real-time optical monitoring of epitaxial growth processes by p-polarized reflectance spectroscopy (PRS) using a single wavelength application under pulsed chemical beam epitaxy (PCBE) condition. The high surface sensitivity of PRS allows the monitoring of submonolayer precursors coverage on the surface as shown for GaP homoepitaxy and GaP on Si heteroepitaxy as examples. In the case of heteroepitaxy, the growth rate and optical properties are revealed by PRS using interference oscillations as they occur during growth. Super-imposed on these interference oscillations, the PRS signal exhibits a fine structure caused by the periodic alteration of the surface chemistry by the pulsed supply of chemical precursors. This fine structure is modeled under conditions where the surface chemistry cycles between phosphorus supersaturated and phosphorus depleted surfaces. The mathematical model describes the fine structure using a surface layer that increases during the tertiarybutyl phosphine (TBP) supply and decreases during and after the triethylgallium (TEG) pulse, which increases the growing GaP film thickness. The imaginary part of the dielectric function of the surface layer is revealed from the turning points in the fine structure, where the optical response to the first precursor pulse in the cycle sequence changes sign. The amplitude of the fine structure is determined by the surface layer thickness and the complex dielectric functions for the surface layer with the underlying bulk film. Surface kinetic data can be obtained by analyzing the rise and decay transients of the fine structure.

Dietz, Nikolaus↗

On the accuracy of shape sensitivity

The calculation of sensitivity of the response of a structure modeled by finite elements to shape variation is known to be subject to numerical difficulties. The accuracy of a given method is typically measured against the yard stick of finite-difference sensitivity calculation. The present paper demonstrates with a simple example that this approach may be flawed because of discretization errors associated with the finite element mesh. Seven methods for calculating sensitivity derivatives are compared for a two-material beam problem with a moving interface. It is found that as the mesh is refined, displacement sensitivity derivatives converge more slowly than the displacements. Six of the methods agree fairly well, but the adjoint variational surface method provides substantially different results. However, the difference is found to reflect convergence from another direction to the same answer rather than reduced accuracy. Additionally, it is observed that small derivatives are particularly prone to accuracy problems.

Haftka, R. T.↗

Phase modulation for reduced vibration sensitivity in laser-cooled clocks in space

The standard interrogation technique in atomic beam clocks is square-wave frequency modulation (SWFM), which suffers a first order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise.

frequency standard frequency modulation phase modu↗

Study of Nonclassical Fields in Phase-Sensitive Reservoirs

We show that the reservoir influence can be modeled by an infinite array of beam splitters. The superposition of the input fields in the beam splitter is discussed with the convolution laws for their quasiprobabilities. We derive the Fokker-Planck equation for the cavity field coupled with a phase-sensitive reservoir using the convolution law. We also analyze the amplification in the phase-sensitive reservoir with use of the modified beam splitter model. We show the similarities and differences between the dissipation and amplification models. We show that a super-Poissonian input field cannot become sub-Poissonian by the phase-sensitive amplification.

Kim, Myung Shik↗

A Sensitive VLA Search for Small-Scale Glycine Emission Toward OMC-1

We have conducted a deep Q-band (lambda-7 mm) search with the Very Large Array (VLA) toward OMC-1 for the lowest energy conformation (conformer I) of glycine (NH2CH2COOH) in four rotational transitions: the 6(sub 15)- 5(sub 14), 6(sub 24)-5(sub 23), 7(sub 17- 6(sub 16), and 7(sub 07)-6(sub 06). Our VLA observations sample the smallest-scale structures to date in the search for glycine toward OMC-1. No glycine emission features were detected. Thus if glycine exists in OMC-1, either it is below our detection limit, or it is more spatially extended than other large molecules in this source, or it is primarily in its high energy form (conformer II). Our VLA glycine fractional abundance limits in OMC-1 are comparable to those determined from previous IRAM 30m measurements -- somewhat better or worse depending on the specific source model -- and the entire approximately 1 foot primary beam of the VLA was searched while sensitive to an areal spatial scale approximately 150 times smaller than the 24 inch beam of the IRAM single-element telescope. In the course of this work, we detected and imaged the 4(sub 14)-3(sub 13) A and E transitions of methyl formate (HCOOCH3) and also the 2(sub 02) - 1(sub 01) transition of formic acid (HCOOH). Since formic acid is a possible precursor to glycine, our glycine limits and formic acid results provide a constraint on this potential formation chemistry route for glycine in OMC-1.

Hollis, J. M.↗

Grating angle magnification enhanced angular sensor and scanner

An angular magnification effect of diffraction is exploited to provide improved sensing and scanning. This effect is most pronounced for a normal or near-normal incidence angle in combination with a grazing diffraction angle, so such configurations are preferred. Angular sensitivity can be further enhanced because the width of the diffracted beam can be substantially less than the width of the incident beam. Normal incidence configurations with two symmetric diffracted beams are preferred, since rotation and vertical displacement can be readily distinguished. Increased sensitivity to vertical displacement can be provided by incorporating an interferometer into the measurement system. Quad cell detectors can be employed to provide sensitivity to rotation about the grating surface normal. A 2-D grating can be employed to provide sensitivity to angular displacements in two different planes (e.g., pitch and yaw). Combined systems can provide sensitivity to vertical displacement and to all three angular degrees of freedom.

Sun, Ke-Xun↗