Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Single Nanocrystal Spectroscopy of Shortwave Infrared Emitters

Short-wave infrared (SWIR) emitters are at the center of ground-breaking applications in biomedical imaging, next-generation optoelectronic devices, and optical communications. Colloidal nanocrystals based on indium arsenide are some of the most promising SWIR emitters to date. However, the lack of single-particle spectroscopic methods accessible in the SWIR has prevented advances in both nanocrystal synthesis and fundamental characterization of emitters. In this paper, we demonstrate an implementation of a solution photon correlation Fourier spectroscopy (s-PCFS) experiment utilizing the SWIR sensitivity and time resolution of superconducting nanowire single-photon detectors to extract single-particle emission linewidths from colloidal indium arsenide/cadmium selenide (InAs/CdSe) core/shell nanocrystals emissive from 1.2 to 1.6 μm. We show that the average single InAs/CdSe nanocrystal fluorescence linewidth is, remarkably, as narrow as 52 meV, similar to what has been observed in some of the most narrowband nanostructured emitters in the visible region. Additionally, the single nanocrystal fluorescence linewidth increases with increasing shell thickness, suggesting exciton–phonon coupling as the dominant emission line-broadening mechanism in this system. The development of the SWIR s-PCFS technique has enabled measurements of spectral linewidths of colloidal SWIR-emissive NCs in solution and provides a platform to study the single NC spectral characteristics of SWIR emitters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High power THz sources for nonlinear imaging

Many biological and chemical compounds have unique absorption features in the THz (0.1 - 10 THz) region, making the use of THz waves attractive for imaging in defense, security, biomedical imaging, and monitoring of industrial processes. Unlike optical radiation, THz frequencies can pass through many substances such as paper, clothing, ceramic, etc. with little attenuation. The use of currently available THz systems is limited by lack of highpower, sources as well as sensitive detectors and detector arrays operating at room temperature. Here we present a novel, high power THz source based on intracavity downconverison of optical pulses. The source delivers 6 ps pulses at 1.5 THz, with an average power of >300 μW and peak powers >450 mW. We propose an imaging method based on frequency upconverison that is ideally suited to use the narrow bandwidth and high peak powers produced by the source. By upconverting the THz image to the infrared, commercially available detectors can be used for real time imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multipurpose Photonic Transducers

Features include smallness and noise immunity. Photonic transducer is interferometer with two arms. Small relative axial motions of mirrors detected as shifts in interference pattern. Version measures temperature changes via differential expansion or contraction of stalks. New transducers smaller (typical size less than 1 cm) and coupled to monitoring equipment with optical fibers instead of wires. Well suited to biomedical instrumentation.

Du Fresne, E. R.↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Insights on proximity effect and multiphoton induced luminescence from gold nanospheres in far field optical microscopy

Gold nanoparticles can be visualized in far-field multiphoton laser-scanning microscopy (MPM) based on the phenomena of multiphoton induced luminescence (MIL). This is of interest for biomedical applications, e.g., for cancer diagnostics, as MPM allows for working in the near-infrared (NIR) optical window of tissue. It is well known that the aggregation of particles causes a redshift of the plasmon resonance, but its implications for MIL applying far-field MPM should be further exploited. Here, we explore MIL from 10 nm gold nanospheres that are chemically deposited on glass substrates in controlled coverage gradients using MPM operating in NIR range. The substrates enable studies of MIL as a function of inter-particle distance and clustering. It was shown that MIL was only detected from areas on the substrates where the particle spacing was less than one particle diameter, or where the particles have aggregated. The results are interpreted in the context that the underlying physical phenomenon of MIL is a sequential two-photon absorption process, where the first event is driven by the plasmon resonance. It is evident that gold nanospheres in this size range have to be closely spaced or clustered to exhibit detectable MIL using far-field MPM operating in the NIR region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold atmospheric pressure plasma jets as sources of singlet delta oxygen for biomedical applications

Absolute densities of singlet delta oxygen (SDO) molecules were measured using infrared optical emission spectroscopy in the flowing effluents of two different atmospheric-pressure plasma jets (APPJs): a capacitively coupled radio-frequency-driven jet (rf-APPJ) and a lower frequency kilohertz-driven dielectric barrier discharge jet. The plasma jets were operated in helium, with small admixtures of molecular oxygen (O{sub 2} < 2%). High absolute SDO densities of up to 6.2 x 10{sup 15} cm{sup -3} were measured at approximately 10 cm downstream. The rf-APPJ seems to be much more efficient in producing SDO. The influence of different parameters, such as gas flows and mixtures and power coupled to the plasmas, on the production of SDO by the two APPJs has been investigated. Despite the considerable differences between the two plasma jets (excitation frequency, electric field direction, inter-electrode distance, plasma propagation), similar dependencies on the oxygen admixture and on the dissipated power were found in both APPJs. However, opposite trends were observed for the gas flow dependence. The results presented in this paper show that the control of the external operating conditions of each APPJ enables the tailoring of the SDO composition of both plasma effluents. This provides scope to tune the plasma jets for desired applications, e.g., in biomedicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.

60 APPLIED LIFE SCIENCES↗

Consortium for materials development in space

During fiscal 1993, the Consortium for Materials Development in Space (CMDS) maintained the organizational structure and project orientation established in prior years. The commercial objectives are improved materials, biomedical applications, and infrastructure and support hardware. Projects include nonlinear optical materials; space materials (specifically polymer foam/films, atomic oxygen and high temperature superconductors); alloyed and blended materials: sintered and alloyed materials; polymer and carbonate blends; electrodeposition; organic separation; materials dispersion and biodynamics; space carriers: Consort, COMET support, Spacehab utilization; and flight services: accelerometers, CMIX, USEC, ORSEP, and Space Experiment Facility (SEF).

Source record↗

Tunable, Ultrafast Fiber-Laser between 1.15 μm and 1.35 μm for Harmonic Generation Microscopy in Human Skin

We demonstrate a fiber-optic ultrafast tunable source for harmonic generation microscopy (HGM) in human skin. The source is based on a 31-MHz Er-fiber laser followed by self-phase modulation enabled spectral selection (SESS). The resulting pulses are tunable between 1.15 and 1.35 μm with up to >10-nJ pulse energy and ~100-fs pulse duration. Here we employ this source to drive a scanning microscope for HGM imaging of ex vivo human skin. A systematic investigation on imaging depth versus excitation wavelength reveals that excitation wavelengths in the 1.15-1.25 μm range exhibit low optical attenuation within the tissue and allows larger imaging depth for HGM in human skin. HGM driven by fiber-based SESS sources constitutes an enabling tool for noninvasive virtual skin biopsy in clinical applications.

60 APPLIED LIFE SCIENCES↗

Photophysical Properties and Electronic Structure of Hydroporphyrin Dyads Exhibiting Strong Through-Space and Through-Bond Electronic Interactions

Electronic interactions between tetrapyrroles are utilized in natural photosynthetic systems to tune the light-harvesting and energy/charge-transfer processes in these assemblies. Such interactions also can be employed to tailor the electronic properties of tetrapyrrolic dyads and larger arrays for use in materials science and biomedical research. Here we have utilized static and time-resolved optical spectroscopy to characterize the optical absorption and emission properties of a set of chlorin and bacteriochlorin dyads with varied degrees of through-bond (TB) and through-space (TS) interactions between the constituent macrocycles. The dyads consist of two chlorins or two bacteriochlorins joined by a linker that utilizes a triple-double-triple bond (enediyne) motif in which the double bond portion is a ester-substituted ethylene or o-phenylene unit. The photophysical studies are coupled with density functional theory (DFT) calculations to probe the ground-state molecular orbital (MO) characteristics of the dyads and time-dependent calculations (TDDFT) to elucidate excited-state properties. The latter include electronic characteristics of the singlet excited state manifold and the absorption transitions to these states from the electronic ground state. Comparison of the MO and calculated spectral properties of each dyad with the linker present versus disrupted (by eliminating the double-bond portion) gives insight into the relative contributions of TB versus TS interactions to the electronic properties of the dyads. The results show that the TB and TS contributions are additive (constructively interfere), which is not always the case for molecular dyads. Most of the dyads have shorter lifetimes of the lowest singlet excited state compared to the parent monomer, which derives from increased S 1 → S 0 internal conversion. The enhancement is greater for the dyads in benzonitrile than in toluene. Furthermore, the studies provide insights into the nature of the electronic interactions between the constituents in the tetrapyrrole arrays and how these interactions dictate the spectral properties and excited-state decay characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold microplasma plume produced by a compact and flexible generator at atmospheric pressure

In this letter, we report a cold microplasma generator at atmospheric pressure excited at 1 kHz in a pin to hole-electrode configuration by using soft materials partly. A nitrogen plasma plume with a length of more than 5 cm can be produced at low electrical power of 0.7 W without high feed gas pressure. The generator exhibits a compact structure with flexible property, which is suitable for treating thermally sensitive materials and biomedical materials, especially for delicate objects in an irregular confined space. Optical emission spectroscopy is used to spatially identify excited species in plasma plume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dissection of the angle of single fluorophore attached to the nucleotide in corkscrewing microtubules

Direct dissection of the angles of single fluorophores under an optical microscope has been a challenging approach to study the dynamics of proteins in an aqueous solution. For angle quantifications of single substrates, however, there was only one report (Nishizaka et al., 2014) because of difficulties of construction of experimental systems with active proteins working at the single-molecule level. We here show precise estimation of orientation of single fluorescent nucleotides bound to single tubulins that comprise microtubule. When single-headed kinesins immobilized on a glass surface drive the sliding of microtubules, microtubules show corkscrewing with regular pitches (Yajima et al., 2005 & 2008). We found, by using a three-dimensional tracking microscope, that S8A mutant kinesin also showed precise corkscrewing with a 330-nm pitch, which is 13% longer than that of the wild type. The assay with the mutant was combined with a defocused imaging technique to visualize the rotational behavior of fluorescent nucleotide bound to corkscrewing microtubule. Notably, the defocused pattern of single TAMRA-GTP periodically changed, precisely correlating to its precession movement. The time course of the change in the fluorophore angle projected to the xy-plane enabled to estimate both the fluorophore orientation against microtubule axis and the precision of angle-determination of analyses system. The orientation showed main distribution with peaks at∼40°, 50° and 60°. To identify their molecular conformations, the rigorous docking simulations were performed using an atomic-level structure modeled by fitting x-ray crystal structures to the cryo-electron microscopy map. Among isomers, 2′-O-EDA-GDP labeled with 5- or 6-TAMRA were mainly specified as possible candidates as a substrate, which suggested the hydrolysis of TAMRA-GTP by tubulins. - Highlights: • The mutant of single-headed kinesin drives the corkscrewing of microtubules with a longer pitch. • Orientation of single fluorescent GTP on rotating microtubule was measured by defocused imaging. • The orientation showed the distribution with peaks at∼40°, 50° and 60° against microtubule axis. • Docking simulation reveals possible molecular conformations and state of nucleotide on tubulin.

60 APPLIED LIFE SCIENCES↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A database of thermally activated delayed fluorescent molecules auto-generated from scientific literature with ChemDataExtractor

A database of thermally activated delayed fluorescent (TADF) molecules was automatically generated from the scientific literature. It consists of 25,482 data records with an overall precision of 82%. Among these, 5,349 records have chemical names in the form of SMILES strings which are represented with 91% accuracy; these are grouped in a subsidiary database. Each data record contains one of the following four properties: maximum emission wavelength (λ EM ), photoluminescence quantum yield (PLQY), singlet-triplet energy splitting (ΔE ST ), and delayed lifetime (τ D ). The databases were created through text mining using ChemDataExtractor, a chemistry-aware natural-language-processing toolkit, which has been adapted for TADF research. The text-mined corpus consisted of 2,733 papers from the Royal Society of Chemistry and Elsevier. To the best of our knowledge, these databases are the first databases that have been auto-generated for TADF molecules from existing publications. The databases have been publicly released for experimental and computational applications in the TADF research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale, printed LEDs for unusual lighting and display systems

Current technology development in light emitting diodes has enabled high efficiency operation, low energy consumption and lifetimes, thereby creating new possibilities in conventional display and lighting industry. Recent work is also creating more unusual uses in biomedicine and in sensing applications, where conformal contact over curvilinear surfaces is required. Here, ultrathin device geometries and optimized mechanical designs, including neutral mechanical plane layouts and serpentine interconnects, provide indicators and lighting modules with arbitrary shapes capable of integrated on nearly any type of substrates. Furthermore, biomedical devices such as light emitting suture threads, and glove-mounted optical proximity sensors demonstrate the versatility of this strategy and create great new opportunities.

42 ENGINEERING↗